Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Date of Grant
Mar 23, 2020
Application Purpose
Original Equipment
Date of Application
Mar 23, 2020
Equipment Note
ARIsense Smart Air Valve System Master Unit
Frequency Range
456.00000000 - 460.00000000
Company
Aquestia
Country
Israel

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Parts List/Tune Up Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

1 IOM ARISENSE - User Manual 2 IOM 2 IOM Disclaimer This document is an Installation, Operation and Maintenance (IOM) manual for A.R.I. Flow Control Accessories Ltd. (A.R.I.) products. The information enclosed herein contains restricted, privileged, proprietary and confidential information, intended only for usage by authorized A.R.I. technicians. If you are not a qualified technician, you must not take any action in reliance upon this document, unless otherwise permitted in writing by A.R.I. A.R.I. has made every effort to ensure that this document is accurate; A.R.I. disclaims liability for any inaccuracies or omissions that may have occurred. All the procedures, drawings, pictures and/or any other information provided in this document are presented as general information only; they can be altered, removed or changed without A.R.I.'s prior written approval. A.R.I. makes no commitment to update or keep the information in this document current and/or up-to- date, and reserves the right to make improvements, alterations and/or modifications to this document and/or to the products described in this document, at any time without providing any notice with respect thereto. Nothing in this Disclaimer derogates in any way whatsoever from the confidential nature of any document enclosed hereto, including for avoidance of doubt, any mistake or clerical error or other error. None of the procedures provided in this Disclaimer and/or in any document enclosed hereto may be used in any form or by any means without the prior written consent from A.R.I. If you received this Disclaimer and/or in any document enclosed hereto in error or by mistake or if this Disclaimer and/or in any document enclosed hereto is not intended for you, please notify A.R.I. in writing immediately. A.R.I. assumes that all users understand the risks involved within this Disclaimer and/or in any document enclosed hereto. A.R.I. accepts/assumes no liability whatsoever, whether caused by: accessing and/or relying upon this Disclaimer and/or in any document enclosed hereto including without limitation any links, procedures or materials. A.R.I. shall NOT assume any liability for any costs, direct or indirect, including loss of income, loss of profits and/or goodwill, legal actions and/or damages of any kind whatsoever including any, damages accidents, equipment damage or bodily injury resulting from and/or related to any of the following: • product has not been duly installed and thereafter maintained in strict compliance with its designated Maintenance Instructions and/or any other installation and operation manuals provided by A.R.I. for the product and/or applicable ordinances and/or codes; • Repairs made in and to the products by personnel not authorized by A.R.I. • Maintenance or repairs using parts or components other than those specified by A.R.I. and in their original condition. • Operating the products in ways other than the operating procedures described in the manuals provided by A.R.I., or resulting from not following the cautionary remarks and warnings in the product manual. • Improper storage, workplace conditions and environmental conditions which do not conform to those stated in the Product manual. • Fires, earthquakes, floods, lightning, natural disasters, or acts of God. A.R.I. does not warrant and hereby disclaims any express or implied warranties that the product will work properly in environments and applications other than its original design purpose, and makes no warranty and representation, either implied or expressed, with respect to the quality, performance, merchantability, or fitness for any other particular purpose. Except as provided herein and to the full extent permitted by law, A.R.I. shall not be responsible and/or liable for direct, special, incidental or consequential damages or loss resulting from any breach of the above or under any other legal theory. This document does not replace any certified drawing, procedure or information provided by A.R.I. in reference to a specific customer, site or project. All rights reserved. 3 IOM 3 IOM 1. SAFETY INSTRUCTIONS General 1. A.R.I. products always operate as components in a larger system. It is essential for the system designers, installers, operators and maintenance personnel to comply with all the relevant safety standards. 2. Installation, operation or maintenance of the product should be done only by qualified workers, technicians and/or contractors using only good engineering practices, complying with and observing all conventional safety instructions in order to minimize risk and/or danger and/or hazard to workers, the public or to property in the vicinity in accordance with all relevant local standards. 3. Extra safety considerations should be taken with hot and hazardous liquids or in hazardous environments' applications to avoid bodily/physical harm and damage to public or private property. 4. All individuals installing operating and/or handling the products including all workers should at all times adhere to the occupational safety and health (OSH) instructions and wear safety helmets, goggles, gloves, and any other personal safety equipment required by the local standards and regulations. 5. Use only appropriate standard tools and equipment operated by qualified operators when installing, operating and maintaining the product. 6. Prior to installation, operation, maintenance or any other type of action carried out on the product, read carefully the safety, installation and operation instructions of the product. 7. Please note: - Pressurized fluid and/or gas may be discharged from the product without prior warning. Make sure that the product's outlet port is not directed toward electrical elements (pumps) or people. - The pressurized fluid and/or gas that can be discharged from the product may create high noise levels. Take this into consideration when installing the product in areas sensitive to noise. 8. Always open and close valves slowly a…

Text truncated - open the document above for the full version.

Cover Letter(s)

November 10, 2019 Federal Communications Commission Authorization and Evaluation Division To: Federal Communications Commission Confidentiality Request regarding application for the FCC certification of FCC ID: 2ASHC-ARISENSE-M19 Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Long Term Confidentiality: a. CONF APPENDIX MASTER Partlst.pdf b. CONF APPENDIX MASTER Schem.pdf c. CONF APPENDIX MASTER BlkDia.pdf d. CONF APPENDIX MASTER OpDes.pdf Short Term Confidentiality: 180 days e. CONF APPENDIX MASTER IntPho.pdf The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. Sincerely, Amir Chapnik R&D Eng.

Cover Letter(s)

November 10, 2019 To: Timco Engineering Inc. To Whom It May Concern We hereby authorize Mr. Ilan Cohen of I.T.L. (Product Testing) Ltd (ITL) to sign FORM 731 on our behalf for the following FCC application: FCC ID: 2ASHC-ARISENSE-M19 Sincerely, Amir Chapnik R&D Eng.

Cover Letter(s)

November 10, 2019 To Whom It May Concern We hereby authorize Mr. Ilan Cohen of I.T.L. (Product Testing) Ltd (ITL) to act on our behalf regarding the following FCC application: FCC ID: 2ASHC-ARISENSE-M19 Thank you, Amir Chapnik R&D Eng.

Parts List/Tune Up Info

November 10, 2019 Declaration Subject: Tune up procedure FCC ID: 2ASHC-ARISENSE-M19 No manual tune-up procedure required. Sincerely, Amir Chapnik R&D Eng.

Test Report

Test Report E194110.01 A.R.I. Flow Control Accessories LTD Page 1 of 38 FCC ACC M Ver 1.1 05Mayl 2000 DATE: 16 March 2020 I.T.L. (PRODUCT TESTING) LTD. FCC Radio Test Report For A.R.I. Flow Control Accessories LTD Equipment under test: ARISense Smart Air Valve System Master Unit; External Box Unit* *See customer declaration on page 6 Tested by: _____________________________ M. Zohar Approved by: _____________________________ D. Shidlowsky This report must not be reproduced, except in full, without the written permission of I.T.L. (Product Testing) Ltd. This report relates only to items tested. Test Report E194110.01 A.R.I. Flow Control Accessories LTD Page 2 of 38 FCC ACC M Ver 1.1 05Mayl 2000 Measurement/Technical Report for A.R.I. Flow Control Accessories LTD ARISense Smart Air Valve System Master Unit FCC ID: 2ASHC-ARISENSE-M19 This report concerns: Original Grant: X Class II change: Class I change: Equipment Class: TNB – Licensed Non-Broadcast Station Transmitter Limits used: 47CFR Parts 2; 90 Measurement procedure used is ANSI C63.26-2015. Substitution Method used as in ANSI TIA-603-E (2016) Application for Certification Applicant for this device: prepared by: (different from "prepared by") R. Pinchuck Amir Chapnick, R&D Engineer ITL (Product Testing) Ltd. A.R.I. Flow Control Accessories LTD 1 Bat Sheva St. Kfar Haruv Lod 7120101 Golan Heights, 1293200, Israel Israel Tel: +972 4-676-1786 E-mail: [email protected] Email: [email protected] Test Report E194110.01 A.R.I. Flow Control Accessories LTD Page 3 of 38 FCC ACC M Ver 1.1 05Mayl 2000 TABLE OF CONTENTS 1. GENERAL INFORMATION ------------------------------------------------------------------------------- 5 1.1 Administrative Information ................................................................................. 5 1.2 List of Accreditations ......................................................................................... 7 1.3 Test Methodology .............................................................................................. 8 1.4 Product Description ........................................................................................... 8 2. SYSTEM TEST CONFIGURATION --------------------------------------------------------------------- 9 2.1 Justification ........................................................................................................ 9 2.2 EUT Exercise Software ..................................................................................... 9 2.3 Special Accessories .......................................................................................... 9 2.4 Equipment Modifications ................................................................................... 9 2.5 Configuration of Tested System ...................................................................... 10 3. TEST SET-UP PHOTOS ----------------------------------------------------------------------------------11 4. RF POWER OUTPUT -------------------------------------------------------------------------------------15 4.1 Test Specification ............................................................................................ 15 4.2 Test Procedure ................................................................................................ 15 4.3 Test Limit ......................................................................................................... 15 4.4 Test Results..................................................................................................... 15 4.5 Test Equipment Used; RF Power Output ........................................................ 17 5. OCCUPIED BANDWIDTH -------------------------------------------------------------------------------18 5.1 Test Specification ............................................................................................ 18 5.2 Test Procedure ................................................................................................ 18 5.3 Test Limit ......................................................................................................... 18 5.4 Test Results..................................................................................................... 18 5.5 Test Equipment Used; Occupied Bandwidth ................................................... 19 6. EMISSION MASK ------------------------------------------------------------------------------------------20 6.1 Test Specification ............................................................................................ 20 6.2 Test Procedure ................................................................................................ 20 6.3 Test Limit ......................................................................................................... 20 6.4 Test Results..................................................................................................... 20 6.5 Test Equipment Used; Emission Mask ........................................................... 22 7. SPURIOUS RADIATED EMISSION -------------------------------------------------------------------23 7.1 Test Specification ............................................................................................ 23 7.2 Test Procedure ................................................................................................ 23 7.3 Test Limit ......................................................................................................... 24 7.4 Test Results..................................................................................................... 24 7.5 Test Instrumentation Used; Radiated Measurements ..................................... 25 8. TRANSMITTER FREQUENCY STABILITY ---------------------------------------------------------26 8.1 Test Specification ............................................................................................ 26 8.2 Test Procedure ...................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Test Set-U p Photos Mask Emission Test Radiated Emission Test, 0.009-30MHz Radiated Emission Test, 30-200MHz Radiated Emission Test, 200-1000MHz Radiated Emission Test, 1000-5000MHz Frequency Stability Test Frequency Behavior Test

Contact Information

Applicant

Amir Chapnik
[email protected]+972-4-6761786Fax: +972-4-6761766

Test Firm

ITL PRODUCT TESTING LTDIlan Cohen
[email protected]972-8-918-6107Fax: +972 8 915 3101

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
29456 MHz - 460 MHz417.00 mW12K5G1D225 Hz
Confidentiality
Long Term
Grant Notes
Power listed is dBm ERP. This device may contain functions that are not operational in U.S. Territories. Operation is only permitted from 450.006 to 454 MHz and 456 to 460 MHz. The antenna(s) used for this transmitter must be installed to provide separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.