Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
RB48A User Manual Contents Notice to Users ............................................................................. Battery Information ..................................................................... Feature Overview ........................................................................ Getting to Know Your Radio ....................................................... Key Functions ................................................................................ Basic Operation and Feature Description ................................ CTCSS/DCS Lists ........................................................................... Frequency Char ............................................................................. Specifications ................................................................................ CAUTION ....................................................................................... Guarantee ...................................................................................... 01 02 03 04 05 05 08 09 09 10 14 Brochures, Software/Firmware, Manual etc, Please contact Notice to Users Before operating this unit, please read this manual carefully. The use of this two-way radio must comply with local government laws and regulations. Improper use may violate the law and result in sanctions, penal- ties, or even imprisonment. Repair and adjustment of this radio are to be performed only by authorized service personnel. To avoid problems caused by electromagnetic field interference or electro- magnetic compatibility, turn off the radio in locations marked with a "Turn Off Radio" sign, such as hospitals and other healthcare facilities. When aboard an aircraft, turn off the radio when instructed to do so by the crew. Do not place the radio within the deployment area of an airbag in vehicles equipped with airbags. Turn off the radio before entering flammable or explosive environments. Do not transmit continuously for extended periods. The radio may become hot and cause burns or damage to the radio. Do not use a radio with a damaged antenna. Contact with a damaged antenna may cause minor burns. Do not expose the radio to prolonged direct sunlight or place it near heating devices. If abnormal odor or smoke is detected coming from the radio, immediately remove the battery from the radio and promptly contact our company or your local dealer. Unpacking and Inspection Before use, open the packaging box and carefully inspect the main unit and the listed standard accessories inside. If any items are missing or damaged during transportation, please contact the carrier or dealer immediately. 1 Battery Information Charging Precautions Charge new batteries or batteries that have not been used for an extended period before initial use. Performing two or three charge/discharge cycles will help the battery reach its optimal capacity. When low battery power is indicated, charge or replace the battery. Compatible Battery Types Use only batteries specified by our company. Using other batteries may cause explosion and personal injury. Note: 1.Do not short-circuit the battery terminals or discard the battery in fire. Do not disassemble the battery pack casing. 2.The ambient temperature during charging should be between 0°C and 40°C. Charging outside this range may prevent proper battery charging. 3.Turn off the radio power when charging. Using the radio while charging may interfere with proper battery charging. 4.Avoid disconnecting the power source or battery during the charging process, as this may disrupt the charging procedure. 5.If the usable time is significantly reduced even after a full charge, the battery has reached the end of its life and should be replaced. 6.Do not disconnect and reconnect a fully charged battery for recharging, as this may shorten battery life or cause damage. 7.Do not charge the battery or radio when they are wet. Before charging, dry them with a cloth to avoid hazards. 8.Eliminating the Risk, keep away from the flammable materials,heat sources and ignition sources while a battery is charged. Charging should only take place in a well ventilated area and when someone is about to be aware and react to a potential issue. 9.To reduce risk of fire, a battery should not be charged for more than 8 hours and disconnect charger from line voltage (AC outlet) by removing main plug even if the batter is not completely charged.Don't leave a device unattended while charging. Disconnect the charger when the device is fully charged: do not overcharge the device. Charging Procedure Note: Turn off the radio while charging. 1.Desktop Charger: Insert the radio with the battery attached into the desk- top charger, ensuring good contact between the battery contacts and the charger contacts. The charger's red indicator light will illuminate steadily, indicating charging is in progress. When the red light turns off and the green light illuminates, the battery is fully charged. Unplug the charger from the outlet and remove the battery. 2 2.Type-C Charging: Use a standard output DC 5V charger. Insert the Type-C cable into the Type-C port. The radio's indicator light will show a steady red light, indicating charging is in progress. When it changes to a steady blue light, the battery is fully charged. Disconnect the charging cable and charger. Accessory Installation Attaching/Detaching the Belt Clip If necessary, attach the provided belt clip by screwing it into the screw holes on the back of the battery pack for easy carrying. To detach the belt clip, simply unscrew the two screws. Attaching the Wrist Strap Thread the wrist strap through the loop on the radio. Feature Overview: ● Channel Adjustment ● Low Battery Alert ● Time-Out Timer (TOT) ● Busy Channel Lockout ● Monitor Function ● Scan Function ● Alarm Function ● Power Level Switching ● VOX Function ● Channel Lock ● Weather Alert ● Dual PTT ● Two-Way Noise Reduction ● Keypad Tone/Voice Announcement 3 Getting to Know Your Radio 4…
Text truncated - open the document above for the full version.
Covered Equipment Attestation Letter For Certification Service in the USA Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name 2ASNS250505 RB48A We, Applicant Company Name: Shenzhen Retevis Technology Co., Ltd. Address: 7/F, 13-C, Zhonghaixin Science&Technology Park, No.12 Ganli 6th Road, Jihua Street, Longgang District, Shenzhen, China Phone: +86-755-23481953 certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. This includes the cybersecurity and anti-virus software produced or provided by Kaspersky Lab, Inc. or any of ist successors and assignees. We certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2026-04-02 Signature Date Name / Title: Dongfang Shen / Manager Company: Shenzhen Retevis Technology Co., Ltd. Address: 7/F, 13-C, Zhonghaixin Science&Technology Park, No.12 Ganli 6th Road, Jihua Street, Longgang District, Shenzhen, China Phone: +86-755-23481953 Fax: N/A E-Mail: [email protected]
Due Diligence Letter For Certification Service in the USA Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern FCC ID Model name 2ASNS250505 RB48A Pursuant to KDB 986446 D01 Covered Equipment Guidance the evaluation of the product above shows compliance for the following reasons: Compliance Evaluation process Results Inherent compliance The chipset(s) used is not capable of running the cybersecurity and/or anti-virus software Compliance The memory used does not allow the running the cybersecurity and/or anti-virus software Compliance The storage capacity does not allow the running the cybersecurity and/or anti-virus software Compliance The operating system used is not capable of running the cybersecurity and/or anti-virus software Compliance No inherent compliance Based on software bill of material Based on scan for running software on the device Based on filesystem scan for cybersecurity and/or anti-virus software The equipment for which authorization is sought complies with the rules and fulfils the requirements as detailed in the above mentioned KDB. Evaluation performed by Company Name: Shenzhen LCS Compliance Testing Laboratory Ltd. Contact Name: Martion Lee Address: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Phone: +86-755-82591330 Email: [email protected] Signature: Date: 2026-03-29
Confidentiality Request Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the documentation of the following products: FCC ID Model name 2ASNS250505 RB48A For the products listed above, we request permanent confidentiality for all applicable exhibits as there are: • the Operational Description • the Block Diagram • the Schematics • the Part List • the Tune up Information The above listed exhibits contain trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2026-04-02 Signature Date Name / Title: Dongfang Shen / Manager Company: Shenzhen Retevis Technology Co., Ltd. Address: 7/F, 13-C, Zhonghaixin Science&Technology Park, No.12 Ganli 6th Road, Jihua Street, Longgang District, Shenzhen, China Phone: +86-755-23481953 Fax: N/A E-Mail: [email protected]
Report No.: CHTW26035223 Page 26 of 27 15. External Photos of the EUT Report No.: CHTW26035223 Page 27 of 27 --- End of Report ---
ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BuildingAand301BuildingC,JujiIndustrialPark,YabianxueziweiShajingStreet,BaoanDistrict, Shenzhen,518000,P.R.C. Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity LABELANDLOCATION Material:tagboard Glue:adhesivesticker Frontcolor:black Labelcolor:White (Size:L3.0cmxW2.0cm) TWOWAYRADIO ModelName:RB48A FCCID:2ASNS250505 LabelLocation W L
InternalPhotosoftheEUT Fig.1 Fig.2 FCC ID: 2ASNS250505 Fig.3 Fig.4 Fig.5 Fig.6 Fig.7 Antenna
TEST REPORT For SAR Report No......................................... : CHTW26035223 Project No ........................................ : SHT2601051002W FCC ID ............................................. : 2ASNS250505 Applicant’s name ............................. : Shenzhen Retevis Technology Co., Ltd Address ............................................ : 7/F, 13-C, Zhonghaixin Science&Technology Park, No.12 Ganli 6th Road, Jihua Street, Longgang District, Shenzhen, China Product Name .................................. : TWO WAY RADIO Trade Mark....................................... : RETEVIS Model No.......................................... : RB48A Listed Model(s) ................................ : - Standard .......................................... : FCC 47 CFR Part2.1093 ANSI/IEEE Std C95.1-1992 IEEE Std 1528-2013 Date of receipt of test sample..........: 2026/1/20 Date of testing.............................: 2026/3/10 Date of issue...............................: 2026/4/1 Result ................... ........................: PASS Compiled by (Position+Printed name+Signature) : File administrator Caspar Chen Supervised by (Position+Printed name+Signature) : Project Engineer Xiaodong Zhao Approved by (Position+Printed name+Signature) : RF Manager Xu Yang Testing Laboratory Name ............. : Shenzhen Huatongwei International Inspection Co., Ltd. Address ............................................ : Building 7, Baiwang Idea Factory, No.1051, Songbai Road, Yangguang Community, Xili Subdistrict, Nanshan District, Shenzhen, Guangdong, China Test Report Form No. ........................ : R0066 Test Report Form(s) Originator ......... : Shenzhen Huatongwei International Inspection Co., Ltd. Master TRF ........................................ : Dated 2025-07 Shenzhen Huatongwei International Inspection Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen Huatongwei International Inspection Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen Huatongwei International Inspection Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context.The test report merely correspond to the test sample.The authenticity of this Test Report and its contents can be verified by contacting the Laboratory, responsible for this Test Report. Report No.: CHTW26035223 Page 2 of 27 Contents 1. Statement of Compliance 3 2. Test Standards and Report version 4 2.1. Test Standards 4 2.2. Report version 4 3. Summary 5 3.1. Client Information 5 3.2. Product Description 5 3.3. Radio Specification Description 5 3.4. Test frequency list 6 3.5. Testing Laboratory Information 6 3.6. Environmental conditions 6 4. Equipments Used during the Test 7 5. Measurement Uncertainty 8 6. SAR Measurements System Configuration 9 6.1. SAR Measurement Set-up 9 6.2. DASY5 E-field Probe System 10 6.3. Phantoms 11 6.4. Device Holder 11 7. SAR Test Procedure 12 7.1. Scanning Procedure 12 7.2. Data Storage and Evaluation 14 8. Position of the wireless device in relation to the phantom 16 8.1. Front-of-face 16 8.2. Body Position 16 9. Dielectric Property Measurements & System Check 17 9.1. Tissue Dielectric Parameters 17 9.2. SAR System Validation 18 9.3. System Check 18 10. SAR Exposure Limits 21 11. Antenna Location 22 12. Radiated Power Measurement Results and Tune-up 23 13. SAR Measurement Results 24 14. Test Setup Photos 25 15. External Photos of the EUT 26 Report No.: CHTW26035223 Page 3 of 27 1. Statement of Compliance Maximum Reported SAR (W/kg @1g) RF Exposure Conditions FRS Front-of-face(Dist.= 25mm) 0.832 Body-worn(Dist.= 0mm) 1.451 Note: 1. This device is in compliance with Specific Absorption Rate (SAR) for general population/uncontrolled exposure limits (1.6 W/kg@1g) specified in FCC 47 CFR part 2 (2.1093) and IEEE Std C95.1, 2. This device had been tested in accordance with the measurement methods and procedures specified in IEEE 1528 and FCC KDB publications. Report No.: CHTW26035223 Page 4 of 27 2. Test Standards and Report version 2.1. Test Standards The tests were performed according to following standards: FCC 47 Part 2.1093: Radiofrequency Radiation Exposure Evaluation:Portable Devices ANSI/IEEE C95.1-1992: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz IEEE Std 1528-2013: IEEE Recommended Practice for Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement Techniques. FCC published RF exposure KDB procedures: KDB 865664 D01 SAR Measurement 100 MHz to 6 GHz v01r04: SAR Measurement Requirements for 100 MHz to 6 GHz KDB 865664 D02 RF Exposure Reporting v01r02: RF Exposure Compliance Reporting and Documentation Considerations KDB 447498 D04 Interim General RF Exposure Guidance v01: Mobile and Portable Device RF Exposure Procedures and Equipment Authorization Policies TCB workshop: April, 2019; Page 19, Tissue Simulating Liquids (TSL) 2.2. Report version Revision No. Date of issue Description N/A 2026-04-01 Original Report No.: CHTW26035223 Page 5 of 27 3. Summary 3.1. Client Information Applicant: Shenzhen Retevis Technology Co., Ltd Address: 7/F, 13-C, Zhonghaixin Science&Technology Park, No.12 Ganli 6th Road, Jihua Street, Longgang District, Shenzhen, China Manufacturer: Shenzhen Retevis Technology Co., Ltd. Address: 7/F, 13-C, Zhonghaixin Science&Technology Park, No.12 Ganli 6th Road, Jihua Street, Longgang District, Shenzhen, China 3.2. Product Description Main unit Name of EUT: TWO WAY RADIO Trade Mark: RETEVIS Model No.: RB48A Listed Model(s): - Power supply: Input: DC 5V, 1000mA DC 3.7V by Rechargeable Li-ion Battery, 2000mAh Hardware version: N/A Software version: N/A Device Dimension: Length x Width x Thickness (mm): 177 x 5…
Text truncated - open the document above for the full version.
Appendix E: DAE and Probe Calibration Certificate 8 of 12 Appendix E: DAE and Probe Calibration Certificate 9 of 12 Appendix E: DAE and Probe Calibration Certificate 10 of 12 Appendix E: DAE and Probe Calibration Certificate 11 of 12 Appendix E: DAE and Probe Calibration Certificate 12 of 12 Appendix F: Dipole Calibration Certificate 1 of 8 1.1. D450V3 Dipole Calibration Certificate Appendix F: Dipole Calibration Certificate 2 of 8 Appendix F: Dipole Calibration Certificate 3 of 8 Appendix F: Dipole Calibration Certificate 4 of 8 Appendix F: Dipole Calibration Certificate 5 of 8 Appendix F: Dipole Calibration Certificate 6 of 8 Appendix F: Dipole Calibration Certificate 7 of 8 Extended Dipole Calibrations Referring to KDB865664 D01, if dipoles are verified in return loss (<-20dB, within 20% of prior calibration), and in impedance (within 5 ohm of prior calibration), the annual calibration is not necessary and the calibration interval can be extended. Head-450 Date of measurement Return-loss (dB) Delta (%) Real Impedance (ohm) Delta (ohm) Imaginary impedance (ohm) Delta (ohm) 2024-01-24 -21.5 58.4 -3.50 2025-01-17 -22.3 3.72 56.3 2.1 -5.19 1.69 2026-01-13 -22.5 4.65 56.2 2.2 -4.96 1.46 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5ohm of prior calibration. Therefore the verification result should support extended calibration. Impedance Measurement Plot-2025/1/17 Appendix F: Dipole Calibration Certificate 8 of 8 Impedance Measurement Plot-2026/1/13
The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Shenzhen STS Test Services Co., Ltd. Radio Test Report Report No.:STS2601256W01 Issued for Shenzhen Retevis Technology Co., Ltd 7/F, 13-C, Zhonghaixin Science&Technology Park, No.12 Ganli 6th Road, Jihua Street, Longgang District, Shenzhen, China Product Name: TWO WAY RADIO Brand Name: RETEVIS Model Name: RB48A Series Model(s): N/A FCC ID: 2ASNS250505 Test Standard: FCC Part 95 Page 2 of 42 Report No.: STS2601256W01 TEST REPORT Applicant’s Name ..................... : Shenzhen Retevis Technology Co., Ltd Address ...................................... : 7/F, 13-C, Zhonghaixin Science&Technology Park, No.12 Ganli 6th Road, Jihua Street, Longgang District, Shenzhen, China Manufacturer's Name ............... : Shenzhen Retevis Technology Co., Ltd Address ...................................... : 7/F, 13-C, Zhonghaixin Science&Technology Park, No.12 Ganli 6th Road, Jihua Street, Longgang District, Shenzhen, China Product Description Product Name ............................ : TWO WAY RADIO Brand Name ............................. : RETEVIS Model Name ............................... : RB48A Series Model(s) .......................... : N/A Test Standards .......................... : FCC Part 95 Test Procedure ........................... : TIA 603-E This device described above has been tested by STS, the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the ShenZhen STS Test Services Co., Ltd. Date of Test ........................................... : Date of receipt of test item .................... : 25 Jan. 2026 Date of performance of tests ................. : 25 Jan. 2026~29 Mar. 2026 Date of Issue ......................................... : 29 Mar. 2026 Test Result ............................................. : Pass Testing Engineer : (Lenon Hou) Technical Manager : (Skylar Li) Authorized Signatory : (Bovey Yang) Page 3 of 42 Report No.: STS2601256W01 Table of Contents 1. SUMMARY OF TEST RESULTS 6 1.1 TEST FACTORY 7 1.2 MEASUREMENT UNCERTAINTY 7 2. GENERAL INFORMATION 8 2.1 GENERAL DESCRIPTION OF THE EUT 8 2.2 DESCRIPTION OF THE TEST MODES 9 2.3 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 9 2.4 DESCRIPTION OF NECESSARY ACCESSORIES AND SUPPORT UNITS 10 2.5 EQUIPMENTS LIST 11 3. FIELD STRENGTHS AND RADIATED SPURIOUS EMISSION 12 3.1 RADIATED EMISSION LIMITS 12 3.2 TEST PROCEDURE 13 3.3 TEST SETUP 14 3.4 EUT OPERATING CONDITIONS 14 3.5 TEST RESULT 15 4. SPURIOUS EMISSION ON ANTENNA PORT 16 4.1 LIMIT 16 4.2 TEST PROCEDURE 16 4.3 TEST SETUP 16 4.4 EUT OPERATION CONDITIONS 16 4.5 TEST RESULT 17 5. BANDWIDTH TEST 20 5.1 LIMIT 20 5.2 TEST PROCEDURE 20 5.3 TEST SETUP 20 5.4 EUT OPERATION CONDITIONS 20 5.5 TEST RESULTS 21 6. TRANSMITTER OUTPUT POWER AND EFFECTIVE RADIATED POWER (E.R.P) 23 6.1 LIMIT 23 6.2 TEST PROCEDURE 23 6.3 TEST SETUP 24 6.4 TEST RESULTS 24 7. EMISSION MASK 25 7.1 LIMIT 25 Page 4 of 42 Report No.: STS2601256W01 Table of Contents 7.2 TEST PROCEDURE 25 7.3 TEST SETUP 25 7.4 EUT OPERATION CONDITIONS 25 7.5 TEST RESULT 26 8. FREQUENCY STABILITY 28 8.1 LIMIT 28 8.2 TEST PROCEDURE 28 8.3 TEST SETUP 28 8.4 EUT OPERATION CONDITIONS 28 8.5 TEST RESULT 29 9. MODULATION LIMIT 30 9.1 LIMIT 30 9.2 TEST PROCEDURE 30 9.3 TEST SETUP 30 9.4 TEST RESULT 31 10. AUDIO LOW PASS FILTER RESPONSE 34 10.1 LIMIT 34 10.2 TEST PROCEDURE 34 10.3 TEST SETUP 34 10.4 TEST RESULT 35 11. AUDIO FREQUENCY RESPONSE 38 11.1 LIMIT 38 11.2 TEST PROCEDURE 38 11.3 TEST SETUP 38 11.4 TEST RESULT 39 APPENDIX 1- PHOTOS OF TEST SETUP 42 Page 5 of 42 Report No.: STS2601256W01 Revision History Rev. Issue Date Report No. Effect Page Contents 00 29 Mar. 2026 STS2601256W01 ALL Initial Issue Page 6 of 42 Report No.: STS2601256W01 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: FCC Part 95 Standard Section Test Item Judgment Remark FCC Part 95.567 Transmitter Output Power and Effective Radiated Power (e.r.p) PASS -- FCC Part 95.573 Authorized Bandwidth PASS -- FCC Part 95.579 Emission Mask PASS -- FCC Part 95.579 Transmitter Radiated Spurious Emission PASS -- FCC Part 95.579 Spurious Emission On Antenna Port PASS -- FCC Part 95.565 Frequency Stability PASS -- FCC Part 95.575 Audio Low Pass Filter Response PASS -- FCC Part 95.575 Audio Frequency Response PASS -- FCC Part 95.575 Modulation Requirements PASS -- NOTE: (1) “N/A” denotes test is not applicable in this Test Report. (2) All tests are according to TIA 603-E. Page 7 of 42 Report No.: STS2601256W01 1.1 TEST FACTORY SHENZHEN STS TEST SERVICES CO., LTD Add. :101, Building B, Zhuoke Science Park, No.190 Chongqing Road, ZhanChengShequ, Fuhai Sub-District, Bao’an District, Shenzhen, Guang Dong, China FCC test Firm Registration Number: 625569 IC test Firm Registration Number: 12108A A2LA Certificate No.: 4338.01 1.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95 %. No. Item Uncertainty 1 RF output power, conducted ±0.87dB 2 Unwanted Emissions, conducted ±2.895dB 3 All emissions, radiated 9K-30MHz ±3.80dB 4 All emissions, radiated 30M-1GHz ±4.09dB 5 All emissions, radiated 1G-6GHz ±4.92dB 6 All emissions, radiated>6G ±5.49dB Page 8 of 42 Report No.: STS2601256W01 2. GENERAL INFORMATION 2.1 GENERAL DESCRIPTION OF THE EUT Product Name TWO WAY RADIO Brand Name RETEVIS Model Name RB48A Series Model(s) N/A Model Difference N/A Operation Frequency Range: 462.5000-467.7125MHz Channel Separation 12.5KHz Modulation Type FM Emission t…
Text truncated - open the document above for the full version.
Report No.: CHTW26035223 Page 25 of 27 14. Test Setup Photos Liquid depth in the flat Phantom Front-of-face(25mm) Body-worn (0mm)
Page 1 of 2 FCC ID: 2ASNS250505 Setup photo RE (Below 1GHz) RE (Above 1GHz) Page 2 of 2 FCC ID: 2ASNS250505 RF Conduction
1408 Pinon Place Fullerton, · California, 92835 · United States
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 1 | 95B | 462.5625 MHz - 462.7125 MHz | 1.256 W | 11K0F3E | 2.5ppm |
| 2 | 95B | 467.5625 MHz - 467.7125 MHz | 374.10 mW | 11K0F3E | 2.5ppm |
| 3 | 95B | 462.55 MHz - 462.725 MHz | 1.2853 W | 11K0F3E | 2.5ppm |