FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Retevis Technology Co., Ltd./
  3. 2ASNSR12

2ASNSR12Receiver

Shenzhen Retevis Technology Co., Ltd.

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Sep 10, 2026
Application Purpose
Original Equipment
Equipment Note
Receiver
Frequency Range
2402.00000000 - 2480.00000000
Company
Shenzhen Retevis Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗
↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

ShenzhenRetevisTechnologyCo.,Ltd. FederalCommunicationsCommission AuthorizationandEvaluationDivision EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MD21046 U.S.AgentDesignatio 8/26/26 n NameandcompanyofU.S.agent:RETEVISINC PhysicalU.S.addressofagent:1733EBROOKPORTSTCOVINA,CA91724UnitedStates FRNofU.S.agent:0033657701 EmailaddressofU.S.agent:[email protected] TelephoneNo:+1(626)362259 Shenzhen Retevis Technology Co., Ltd.acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID:2ASNSR12): 4 RETEVISINCacknowledgestheirobligationtoacceptserviceofprocessonbehalfofShenzhenRetevis TechnologyCo.,Ltd. ShenzhenRetevisTechnologyCo.,Ltd.withtheFRN0028298024acceptsitsobligationtomaintainanagent forserviceofprocessintheUnitedStatesfornolessthanoneyearaftereitherthegranteehaspermanently terminatedallmarketingandimportationoftheapplicableequipmentwithintheU.S.,ortheconclusionofany Commission-relatedadministrativeorjudicialproceedinginvolvingtheequipment,whicheverislater. Bysigningthisform,weconfirmtheaboveandthatweareawareoftheapplicationrequirementslistedunder§ 2.911(d)(7). TheinformationprovidedinthisletterisbasedonthereferencedrulepartsofTitle47oftheCFRaswellasKDB 986446D01. Anexpirationdateforthisletterdoesnotexist.IncasetheU.S.agentchanges,thegranteeisobligatedtonotify theFCCwithin30daysviathegrantingTCB. Sincerely, Signature [Name]DongfangShen [Title]GeneralManager [Company]ShenzhenRetevisTechnologyCo.,Ltd. 4 8 _ [ m o d e l ] U S _ A g e n t _ 2 . 9 1 1 ( d ) ( 7 ) - U , V 0 5 ShenzhenRetevisTechnologyCo.,Ltd. Signature [NameofU.S.agent]LIUYELI [TitleofU.S.agent]Director [CompanyofU.S.agent]RETEVISINC

Attestation Statements

Attestation Statement. Old Code: C5266091 24 New Code: 00015544 Ed.3 Change reason: FRN is added to the Applicant information section. 1/1 Shenzhen Retevis Technology Co., Ltd. TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 The Commission adopted rules that prohibit equipment authorization for “covered” telecommunications equipment and video surveillance equipment produced by entities identified on the Commission’s Covered List 1 , which is periodically updated. See the Covered List for more details. This Attestation Statement is to confirm that we follow the Section 2.911(d)(5)(i)-(ii) Applicant Company name: Shenzhen Retevis Technology Co., Ltd. Grantee code: 2ASNS FCC ID: 2ASNSR12 FRN: 0028298024 Contact Name: Dongfang Shen Address: 7/F, 13-C, Zhonghaixin Science&Technology Park, No.12 Ganli 6th Road,Jihua Street, Longgang District, Shenzhen, China Telephone No: +86-755-23481953 Fax No: +86-755-23481953 Email: [email protected] i. [Shenzhen Retevis Technology Co., Ltd.] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. The applicant must sign this certification. ii. [Shenzhen Retevis Technology Co., Ltd.] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [is not] (as a specifically named entity or any of its subsidiaries or affiliates) identified on the Covered List as an entity producing “covered” equipment. The applicant must sign this certification. [Shenzhen Retevis Technology Co., Ltd.] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [is not] identified on the Covered List as an entity producing “covered” equipment . Date: 2026/09/02 Applicant’s Name: Dongfang Shen Title: Manager Signature 1 The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist

Attestation Statements

Shenzhen Retevis Technology Co., Ltd. Code 00018768 Ed. 1 Item 1. The device is able to install software/program installation? ☐ Yes, go to Item 2. ☒ No. In this case, the rest of the items do not apply. The device cannot support installation of Kaspersky cybersecurity or anti-virus software. Item 2. Technical Requirements for Kaspersky Cybersecurity Software: # General Requirements (For all Devices) Yes / No or N/A Comments 1 Internet connection for activation and updates (For all Operating Systems) N/A Device Receiver Company name Shenzhen Retevis Technology Co., Ltd. Grantee code 2ASNS FCC ID 2ASNSR12 FRN 0028298024 Contact name Dongfang Shen Address 7/F, 13-C, Zhonghaixin Science&Technology Park, No.12 Ganli 6th Road,Jihua Street, Longgang District, Shenzhen, China Telephone number +86-755-23481953 E-mail [email protected] Chipset/module information AB5632B Operating System (if applicable) N/A Storage Capacity (hard drive or other permanent memory storage, if applicable) N/A 2 # General Requirements (For Windows Devices) Yes / No or N/A Comments 1 Storage: 1500 MB free space on the hard drive N/A 2 Operating System: Microsoft Windows 8, 8.1, 10 & 11 Home / Pro / Enterprise Microsoft Windows 7 Starter / Home Basic & Premium / Professional / Ultimate SP1 or higher N/A 3 Processor: 1 GHz or higher (x86 or x64) N/A 4 Memory (RAM)1 GB (32-bit) or 2 GB (64-bit) N/A 5 Screen Resolution: Minimum resolution of 1024 x 768 N/A # General Requirements (For macOS devices) Yes / No or N/A Comments 1 Operating System macOS® 13 – 14 N/A 2 Memory (RAM)4 GB N/A 3 Storage: 3455 MB free space on the hard drive N/A # General Requirements (For Android Devices) Yes / No or N/A Comments 1 Storage: 150 MB free space N/A 2 Operating System: Android™ 10 – 14 N/A 3 Screen Resolution: Minimum resolution of 320 x 480 N/A # General Requirements (for iOS devices) Yes / No or N/A Comments 1 Storage: 150 MB free space N/A 2 Operating System: iOS® 17 N/A 3 # General Requirements (For Linux system) Yes / No or N/A Comments 1 Hard drive: 1 GB of free space N/A 2 CPU: Intel Pentium 1 GHz or higher N/A 3 RAM: 1 GB N/A 4 Minimum software requirements: AlmaLinux OS 8 or later; AlterOS 7.5 or later; Astra Linux Common Edition 2.12 or later; CentOS 6.7 or later; Debian GNU/Linux 10.0 or later; EulerOS 2.0 or later; Oracle Linux 7.3 or later ; Red Hat Enterprise Linux 6.7 or later ; Rocky Linux 8.5 or later ; SUSE Linux Enterprise Server 12.5 or later; Ubuntu 12.04 or later ; Uncom OS Home / Business / Education / Enterprise 2.2 or later; ALT Linux Workstaton / Workstation K / Server / Education 8 or later; ROSA Linux Workstation / Server 12 or later ; RED OS 7.3 and later ; N/A After reviewed the technical requirements, is the device capable of supporting the installation of Kaspersky software? ☐ Yes, go to Item 3. ☒ No. In this case, the rest of the items do not apply. The device cannot support installation of Kaspersky software 4 Item 3. Connectivity Capabilities: # Physical Interface Purpose Justification 1 1 # Wireless Interface Purpose Justification 1 1 After the review of this items, the device: ☒ Cannot support installation of any cybersecurity or anti-virus software on the covered list. ☐ Potentially can operate with any cybersecurity or anti-virus software on the covered list – additional third- party proof is provided to demonstrate compliance with requirements as of 2.911(d)5(i),(ii) – “Proof of Compliance with Covered List Software Requirements” of this document applies Signature: Name: Dongfang Shen Date:2026-09-02 1 The justification field is used to justify why the software cannot be received through that interface. Check the annex for more indications.

Attestation Statements

ShenzhenRetevisTechnologyCo.,Ltd. ProductSimilarityDeclaration Productname:Receiver Modelname:TT120S,TT120,TT120P,TT120U FCCID:2ASNSR12 We(ShenzhenRetevisTechnologyCo.,Ltd.)herebystatethatallthe modelsareelectricalidenticalincludingthesamesoftwareparameter andhardwaredesign(i.e.,circuitdesign,PCBLayout,RF module/circuit,antennatype(s)andantennalocation,componentson PCB,etc.,),samemechanicalstructureanddesign(includingproduct enclosure,materials,etc.,),theonlydifferenceisthemodelname. Signature: Name:DongfangShen Title:Manager 2026/9/2

Attestation Statements

TCB CALL página 1 File FCC ID: 2ASNSR12 Please upload an exhibit that explains how does the TCB verify the new agent information: 1- Is the address of the agent a valid physical US mailing address (not a US post office box, not a virtual mailbox, not P.O. Boxes, not a vacant lot, not a public building, etc.) ○ We have checked if the address exists in a real and potential building (Google maps) + official US register, after this verification and the evidence below we can guarantee the following: not a US post office box not a virtual mailbox not P.O. Boxes not a vacant lot not a public building(note) ► We checked the FCC FRN Search based on the information provided by the grantee. On the official register from : https://bizfileonline.sos.ca.gov/search/business TCB CALL página 2 TCB CALL página 3 TCB CALL página 4 In Google maps: TCB CALL página 5 ► CONCLUSION by TCB: The ASOP defined and provided by grantee is VALID and confirmed. Therefore the exhibit "C5266091_X23_Ed1_US_Agent_Letter" included in the file is ok. 2- Is the agent physically located at that valid US address such that the agent can be legally served at that address? Yes , check above 3- Has the listed agent clearly agreed in writing to serve as the agent for the grantee at that address? Yes, it is included in the exhibit "C5266091_X23_Ed1_US_Agent_Letter" >

Cover Letter(s)

C5266091_X10_Ed.2 1/1 ShenzhenRetevisTechnologyCo., Ltd. Officeof EngineeringTechnology FederalCommunicationsCommission 7435 OaklandMills Road Columbia,MD 21046 Date:2026-09-02 Subject:Requestfor Confidentiality FCC ID:2ASNSR12 To WhomIt May Concern, Pursuantto the provisionsof Sections0.457and 0.459of Commission'srules (47CFR0.457,0.459),we are requestingthe Commissionto withholdthe following attachment(s)as confidentialdocumentfrom publicdisclosure. ExhibitsLong-Term Confidentiality Short-TermConfidentiality NOTE2 ID Label/LocationNoNo AttestationStatementNoNo ExternalPhotosNo ☒ Block Diagram ☒☐ Schematics ☒☐ Test ReportNoNo Test SetupPhotosNo ☒ User’ s Manual ☐ NOTE 1 ☒ InternalPhotos ☐ NOTE 1 ☒ Parts List / Tune Up ☐ RF ExposureInfoNoNo OperationalDescription ☒☐ CoverLetter(s)NoNo SDR Software/ SecurityInfo ☐ No NOTE1: Long-TermConfidentialitymay be permittedunderspecialconditions(SeeII. LONG-TERMCONFIDENTIALITY,Section3 of KDB 726920,use last in force) NOTE2: Short-TermConfidentialitycan be requestedfor a maximumof 180 daysfromthe dateof the grant. Abovementioneddocumentcontainsdetailedsystemand equipmentdescriptionare consideredas proprietaryinformationin operationof the equipment.The public disclosureof abovedocumentsmightbe harmfulto our companyand wouldgive competitoran unfairadvantagein the market. In case of short-termConfidentiality,the applicantrequeststhe exhibitsselectedabove are withheldfrom publicview for a periodof ___ 180___ days from the date of the Grantof EquipmentAuthorizationand prior to marketing. It is our understandingthat all measurementtest reports,FCC ID label formatand correspondentduringcertificationreviewprocesscannotbe grantedas confidential documentsand thoseinformationwill be availablefor publicreviewonce the grantof equipmentauthorizationis issued. ☒ C5266091_X10_Ed.2 1/1 Sincerely, Name:DongfangShen Title:Manager 2026/9/2

Cover Letter(s)

C5266091_X8_Ed.1 1/1 Letter of Authorization Shenzhen Retevis Technology Co., Ltd. Company: Shenzhen Retevis Technology Co., Ltd. Address: 7/F, 13-C, Zhonghaixin Science&Technology Park, No.12 Ganli 6th Road,Jihua Street, Longgang District, Shenzhen, China Product Name: Receiver Model Number: TT120S, TT120, TT120P, TT120U FCC Identifier: 2ASNSR12 We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: Dongfang Shen Date: 2026.09.02 Title: Manager Signature of applicant:

ID Label/Location Info

LabelLocation Confirmtheuseofrealappearancephotosasreferences Labelsize: ( L:2cm*W:1cm ) ProductName:Receiver ModelNo.:TT120S FCCID:2ASNSR12

RF Exposure Info

RFEXPOSUREEVALUATION FCCID:2ASNSR12 AccordingtoKDB447498D01MobileandPortableDevicesRFExposureProcedures andEquipmentAuthorizationPoliciesv06. AccordingtoFCC1.1310:Thecriterialistedinthefollowingtableshallbeusedto evaluatetheenvironmentimpactofhumanexposuretoradiofrequency(RF)Radiationas specifiedin§1.1307(b): RoutineSARevaluationreferstothatspecificallyrequiredby§2.1093,using measurementsorcomputersimulation.WhenroutineSARevaluationisnotrequired, portabletransmitterswithoutputpowergreaterthantheapplicablelowthresholdrequire SARevaluationtoqualifyforTCBapproval. Channel (MHz) Maximum output power (dBm) Tuneup tolerance (dBm) MaxTuneUp Power(dBm) Distance (mm) Calculation results Limit Operating Mode 24025.505.50±16.50051.3853 GFSK24416.006.00 ±1 7.00051.5663 24806.276.27±17.27051.6803 24024.514.51±15.51051.1023 π/4-DQPSK24415.115.11 ±1 6.11051.2763 24805.315.31±16.31051.3473 24025.055.05±16.05051.2483 8DPSK24415.635.63 ±1 6.63051.4383 24805.905.90±16.90051.5433 Result:NoStandaloneSARtestisrequired.

Test Report

Page 1 of 39 FCC Test Report Report No.:1812C60360712501 Applicant:Shenzhen Retevis Technology Co., Ltd. Address: 7/F, 13-C, Zhonghaixin Science&Technology Park, No.12 Ganli 6th Road,Jihua Street, Longgang District, Shenzhen, China Product Name:Receiver Report Date:2026-09-08 Shenzhen Anbotek Compliance Laboratory Limited Note: This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, or any agency of the U.S. Government. This report contains data that are not covered by the NVLAP accreditation.The * items are not within the approved scope. #检测章# #资质章# #报告二维码# Report No.:1812C60360712501Page 2 of 39 FCC ID: 2ASNSR12 Contents 1. General Information ...............................................................................................................................6 1.1. Client Information ........................................................................................................................6 1.2. Description of Device (EUT) ........................................................................................................6 1.3. Auxiliary Equipment Used During Test........................................................................................7 1.4. Operation channel list..................................................................................................................7 1.5. Description of Test Mode(s) ........................................................................................................8 1.6. Measurement Uncertainty ...........................................................................................................8 1.7. Additional Instructions .................................................................................................................9 1.8. Test Summary .............................................................................................................................9 1.9. Description of Test Facility ........................................................................................................10 1.10. Disclaimer................................................................................................................................10 1.11. Test Equipment List.................................................................................................................11 2. Antenna requirement ...........................................................................................................................13 2.1. Conclusion.................................................................................................................................13 3. Conducted Emission at AC power line ................................................................................................14 3.1. EUT Operation ..........................................................................................................................14 3.2. Test Setup .................................................................................................................................14 3.3. Test Data ...................................................................................................................................15 4. 20dB Bandwidth ..................................................................................................................................17 4.1. EUT Operation ..........................................................................................................................18 4.2. Test Setup .................................................................................................................................18 4.3. Test Data ...................................................................................................................................18 5. Maximum Conducted Output Power....................................................................................................19 5.1. EUT Operation ..........................................................................................................................19 5.2. Test Setup .................................................................................................................................19 5.3. Test Data ...................................................................................................................................19 6. Channel Separation .............................................................................................................................20 6.1. EUT Operation ..........................................................................................................................20 6.2. Test Setup .................................................................................................................................21 6.3. Test Data ...................................................................................................................................21 7. Number of Hopping Frequencies.........................................................................................................22 7.1. EUT Operation ..........................................................................................................................22 7.2. Test Setup .................................................................................................................................23 7.3. Test Data ...................................................................................................................................23 8. Dwell Time ...........................................................................................................................................24 8.1. EUT Operation ..........................................................................................................................25 8.2. Test Setup .............................................................................…

Text truncated - open the document above for the full version.

Test Report

Manufacturer:HONGKONGRETEKESSCO.,LIMITED Address:FLAT/RM1019B10/FLIVENHOUSENO.61-63KINGYIPSTREETKWUN TONGKL Freq:2440MH Antenna Type:integrated antenna Frequency Range:2400-2500MHz z Freq(MHz)Gain(dBi)Efficiency(%) 2400-1.2528 2410-1.1528 2420-1.1728 2430-1.1528 2440-1.0629 2450-1.1829 2460-1.5127 2470-1.6226 2480-1.8625 2490-2.2623 2500-2.7921 BTANT

Test Report

ReportNo.:1812C60360712501-01 Page 1 of 56 AppendixTestData ReportNo.:1812C60360712501-01TestSampleNo.:1-2-2 StartTestDate:2026-6-29FinishTestDate:2026-7-3 TestEngineer:Auditor: Temperature:26.9 °C RelativeHumidity:55% Pressure:101kPa AppendixA:20dBBandwidth TestResult TestModeAntenna Frequency [MHz] 20db EBW[MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict DH5Ant124020.9392401.5352402.474------ DH5Ant124410.9602440.5262441.486------ DH5Ant124800.9572479.5262480.483------ 2DH5Ant124021.3322401.3282402.660------ 2DH5Ant124411.3622440.3162441.678------ 2DH5Ant124801.3262479.3252480.651------ 3DH5Ant124021.3112401.3432402.654------ 3DH5Ant124411.3172440.3402441.657------ 3DH5Ant124801.3142479.3402480.654------ ReportNo.:1812C60360712501-01 Page 2 of 56 TestGraphs DH5-Ant1-2402 DH5-Ant1-2441 ReportNo.:1812C60360712501-01 Page 3 of 56 DH5-Ant1-2480 2DH5-Ant1-2402 ReportNo.:1812C60360712501-01 Page 4 of 56 2DH5-Ant1-2441 2DH5-Ant1-2480 ReportNo.:1812C60360712501-01 Page 5 of 56 3DH5-Ant1-2402 3DH5-Ant1-2441 ReportNo.:1812C60360712501-01 Page 6 of 56 3DH5-Ant1-2480 ReportNo.:1812C60360712501-01 Page 7 of 56 AppendixB:99%OccupiedBandwidth TestResult TestModeAntenna Frequency [MHz] OCB[MHz]FL[MHz]FH[MHz]Limit[MHz]Verdict DH5Ant124020.850282401.56622402.4165------ DH5Ant124410.851372440.56742441.4188------ DH5Ant124800.856502479.56502480.4215------ 2DH5Ant124021.18192401.40172402.5836------ 2DH5Ant124411.17872440.40292441.5816------ 2DH5Ant124801.17392479.40462480.5785------ 3DH5Ant124021.18592401.40112402.5870------ 3DH5Ant124411.17982440.40292441.5827------ 3DH5Ant124801.18752479.40202480.5895------ ReportNo.:1812C60360712501-01 Page 8 of 56 TestGraphs DH5-Ant1-2402 DH5-Ant1-2441 ReportNo.:1812C60360712501-01 Page 9 of 56 DH5-Ant1-2480 2DH5-Ant1-2402 ReportNo.:1812C60360712501-01 Page 10 of 56 2DH5-Ant1-2441 2DH5-Ant1-2480 ReportNo.:1812C60360712501-01 Page 11 of 56 3DH5-Ant1-2402 3DH5-Ant1-2441 ReportNo.:1812C60360712501-01 Page 12 of 56 3DH5-Ant1-2480 ReportNo.:1812C60360712501-01 Page 13 of 56 AppendixC:MaximumConductedOutputPower TestResultPeak Test Mode AntennaFrequency[MHz] ConductedPeak Power[dBm] Conducted Limit[dBm] Verdict DH5Ant124025.50≤20.97PASS DH5Ant124416.00≤20.97PASS DH5Ant124806.27≤20.97PASS 2DH5Ant124024.51≤20.97PASS 2DH5Ant124415.11≤20.97PASS 2DH5Ant124805.31≤20.97PASS 3DH5Ant124025.05≤20.97PASS 3DH5Ant124415.63≤20.97PASS 3DH5Ant124805.90≤20.97PASS ReportNo.:1812C60360712501-01 Page 14 of 56 TestGraphs DH5-Ant1-2402-PASS DH5-Ant1-2441-PASS ReportNo.:1812C60360712501-01 Page 15 of 56 DH5-Ant1-2480-PASS 2DH5-Ant1-2402-PASS ReportNo.:1812C60360712501-01 Page 16 of 56 2DH5-Ant1-2441-PASS 2DH5-Ant1-2480-PASS ReportNo.:1812C60360712501-01 Page 17 of 56 3DH5-Ant1-2402-PASS 3DH5-Ant1-2441-PASS ReportNo.:1812C60360712501-01 Page 18 of 56 3DH5-Ant1-2480-PASS ReportNo.:1812C60360712501-01 Page 19 of 56 AppendixD:Carrierfrequencyseparation TestResult TestModeAntenna Frequency [MHz] Result [MHz] Limit[MHz]Verdict DH5Ant1Hop1.016≥0.640PASS 2DH5Ant1Hop1.008≥0.908PASS 3DH5Ant1Hop0.942≥0.878PASS Note:Forconductedpowerlessthan0.125W(20.97dBm),thelimitcanbesetusinghoppingchannelcarrier frequenciesthatareseparatedby25kHzortwothirdsofthe20dBbandwidthofthehoppingchannel,whichever isgreater. ReportNo.:1812C60360712501-01 Page 20 of 56 TestGraphs DH5-Ant1-Hop-PASS 2DH5-Ant1-Hop-PASS ReportNo.:1812C60360712501-01 Page 21 of 56 3DH5-Ant1-Hop-PASS ReportNo.:1812C60360712501-01 Page 22 of 56 AppendixE:DwellTime TestResult TestModeAntenna Frequency [MHz] BurstWidth [ms] TotalHops [Num] Result [s] Limit [s] Verdict DH5Ant1Hop2.9041010.293≤0.4PASS 2DH5Ant1Hop2.9111130.329≤0.4PASS 3DH5Ant1Hop2.9121120.326≤0.4PASS ReportNo.:1812C60360712501-01 Page 23 of 56 TestGraphs DH5-Ant1-Hop-PASS ReportNo.:1812C60360712501-01 Page 24 of 56 2DH5-Ant1-Hop-PASS ReportNo.:1812C60360712501-01 Page 25 of 56 3DH5-Ant1-Hop-PASS ReportNo.:1812C60360712501-01 Page 26 of 56 AppendixF:NumberofHoppingChannel TestResult TestModeAntenna Frequency [MHz] Result [Num] Limit [Num] Verdict DH5Ant1Hop79≥15PASS 2DH5Ant1Hop79≥15PASS 3DH5Ant1Hop79≥15PASS ReportNo.:1812C60360712501-01 Page 27 of 56 TestGraphs DH5-Ant1-Hop-PASS 2DH5-Ant1-Hop-PASS ReportNo.:1812C60360712501-01 Page 28 of 56 3DH5-Ant1-Hop-PASS ReportNo.:1812C60360712501-01 Page 29 of 56 AppendixG:ConductedBandedge TestResult TestModeAntenna Ch. Name Frequency [MHz] Ref.Level [dBm] Result [dBm] Limit [dBm] Verdict DH5Ant1Low24025.39-47.9≤-14.61PASS DH5Ant1High24805.76-53.21≤-14.25PASS DH5Ant1LowHop_24021.91-54.55≤-18.09PASS DH5Ant1HighHop_24802.81-47.92≤-17.19PASS 2DH5Ant1Low24021.87-49.6≤-18.13PASS 2DH5Ant1High24802.95-54.65≤-17.05PASS 2DH5Ant1LowHop_2402-0.47-55.8≤-20.47PASS 2DH5Ant1HighHop_24801.63-50.93≤-18.38PASS 3DH5Ant1Low24022.09-47.74≤-17.91PASS 3DH5Ant1High24803.16-54.3≤-16.84PASS 3DH5Ant1LowHop_2402-0.16-54.38≤-20.16PASS 3DH5Ant1HighHop_24802.97-48.31≤-17.03PASS Remark:Regardingthespuriousemissionsfrom30MHzto26.5GHz,thecablelosshavebeensetinthe'offset'of theSpectrumAnalyzerduringthetest. ReportNo.:1812C60360712501-01 Page 30 of 56 TestGraphs DH5-Ant1-2402-PASS DH5-Ant1-2480-PASS ReportNo.:1812C60360712501-01 Page 31 of 56 DH5-Ant1-Hop_2402-PASS DH5-Ant1-Hop_2480-PASS ReportNo.:1812C60360712501-01 Page 32 of 56 2DH5-Ant1-2402-PASS 2DH5-Ant1-2480-PASS ReportNo.:1812C60360712501-01 Page 33 of 56 2DH5-Ant1-Hop_2402-PASS 2DH5-Ant1-Hop_2480-PASS ReportNo.:1812C60360712501-01 Page 34 of 56 3DH5-Ant1-2402-PASS 3DH5-Ant1-2480-PASS ReportNo.:1812C60360712501-01 Page 35 of 56 3DH5-Ant1-Hop_2402-PASS 3DH5-Ant1-Hop_2480-PASS ReportNo.:1812C60360712501-01 Page 36 of 56 AppendixH:ConductedSpuriousEmission TestResult TestModeAntennaFrequency[MHz] Freq.Range [MHz] Ref.Level [dBm] Result [dBm] Limit [dBm] Verdict DH5Ant124020~Reference4.474.47---PASS DH5Ant1240230~10004.47-68.98≤-15.53PASS DH5Ant124021000~265004.47-35.1≤-15.53PASS DH5Ant124410~Reference5.785.78---PASS DH5Ant1244130~10005.78-69.15≤-14.22PASS DH5Ant124411000~265005.78-35.47≤-14.22PASS DH5Ant124800~Reference5.875.87---PASS DH5Ant124803…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Dongfang Shen(Manager)
[email protected]Fax: +86-755-23481953

Technical Contact

RETEVIS INCLIUYE LI
[email protected]

1733 E BROOKPORT ST COVINA, CA 91724 United States · COVINA, California, 91724 · United States

Test Firm

Shenzhen Anbotek Compliance Laboratory LimitedJeff Zhu
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz4.20 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted.