FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Jianida Electronics Co. Ltd./
  3. 2ASORQ6

2ASORQ6Surveillance camera

Shenzhen Jianida Electronics Co. Ltd.
Surveillance camera - FCC ID 2ASORQ6 - Shenzhen Jianida Electronics Co. Ltd.
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Dec 17, 2025
Application Purpose
Original Equipment
Equipment Note
Surveillance camera
Frequency Range
2402.00000000 - 2480.00000000
Company
Shenzhen Jianida Electronics Co. Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

FCC Warnning: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection againstharmful interference in a residential installation. This equipment generates, uses and can radiateradio frequency energy and, if not installed and used in accordance with the instructions, maycause harmful interference to radio communications. However, there is no guarantee thatinterference will not occur in a particular installation. If this equipment does cause harmfulinterference to radio or television reception, which can be determined by turning the equipmentoff and on, the user is encouraged to try to correct the interference by one or more of thefollowing measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.

Attestation Statements

Shenzhen Jianida Electronics Co. Ltd. 4/F, 2 Building, YueTong Shitouling Industrial No.11 Huada Road Longhua New District, Shenzhen, Guangdong China Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2025/12/15 U.S. Agent Designation Shenzhen Jianida Electronics Co. Ltd. acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: 2ASORQ6): Name and company of U.S. agent: GLOCERTS TECHNOLOGY INC Physical U.S. address of agent: 19784 SUNKISSED RIDGE DR RIVERSIDE, CA 92507 United States FRN of U.S. agent: 0036339737 Email address of U.S. agent: [email protected] GLOCERTS TECHNOLOGY INC acknowledges their obligation to accept service of process on behalf of Shenzhen Jianida Electronics Co. Ltd. Shenzhen Jianida Electronics Co. Ltd. with the FRN [0028308237] accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. Sincerely, Signature Yusen Zhang Manager Shenzhen Jianida Electronics Co. Ltd. Signature Huiying Fan Director GLOCERTS TECHNOLOGY INC 48_[mo del] US_Agent_2.911(d)(7) - U, V0 5

External Photos

FCC ID:2ASORQ6 External Photos of the EUT FCC ID:2ASORQ6 FCC ID:2ASORQ6

ID Label/Location Info

Label and Location Size: L: 4.0cm*W: 3.0cm Label and Location FCC ID : 2ASORQ6

Internal Photos

FCC ID:2ASORQ6 Internal Photos of the EUT FCC ID:2ASORQ6 FCC ID:2ASORQ6 FCC ID:2ASORQ6 FCC ID:2ASORQ6 FCC ID:2ASORQ6 FCC ID:2ASORQ6 ANT FCC ID:2ASORQ6 FCC ID:2ASORQ6

RF Exposure Info

Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn RF Exposure MPE Report Reference No. ..................... : FCC ID............................................. : CTA25112001903 2ASORQ6 Compiled by ( position+printed name+signature) . : File administrators Zoey Cao Supervised by ( position+printed name+signature) . : Project Engineer Ace Chai Approved by ( position+printed name+signature) . : RF Manager Eric Wang Date of issue .................................... : Nov. 28, 2025 Testing Laboratory Name .............. : Shenzhen CTA Testing Technology Co., Ltd. Address............................................ : Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Applicant’s name ............................ : Shenzhen Jianida Electronics Co. Ltd. Address............................................ : 4/F, 2 Building, YueTong Shitouling Industrial No.11 Huada Road Longhua New District, Shenzhen, Guangdong, 518000 China Standard ........................................... : 47CFR §1.1310 47CFR §2.1091 KDB447498 D01 General RF Exposure Guidance v06 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purpses as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description ..................... : Surveillance camera Trade Mark ....................................... : N/A Manufacturer .................................... : Shenzhen Jianida Electronics Co. Ltd. Model/Type reference ...................... : Q6 Listed Models ................................... : Q1, Q2, Q3, Q5 Rating ............................................... : DC 5.0V From external circuit Result ............................................... : PASS Report No.: CTA25112001903 Page 2 of 10 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn T E S T R E P O R T Equipment under Test : Surveillance camera Model /Type : Q6 Listed Models : Q1, Q2, Q3, Q5 Model difference : The PCB board, circuit, structure and internal of these models are the same, Only model number and colour is different for these model. Applicant : Shenzhen Jianida Electronics Co. Ltd. Address : 4/F, 2 Building, YueTong Shitouling Industrial No.11 Huada Road Longhua New District, Shenzhen, Guangdong, 518000 China Manufacturer : Shenzhen Jianida Electronics Co. Ltd. Address : 4/F, 2 Building, YueTong Shitouling Industrial No.11 Huada Road Longhua New District, Shenzhen, Guangdong, 518000 China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA25112001903 Page 3 of 10 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Contents 1 TEST STANDARDS ............................................................................................................ 4 2 SUMMARY .......................................................................................................................... 5 2.1 General Remarks ..................................................................................................... 5 2.2 Product Description ................................................................................................. 5 2.3 Special Accessories ................................................................................................. 6 2.4 Modifications ............................................................................................................ 6 3 TEST ENVIRONMENT ....................................................................................................... 7 3.1 Address of the test laboratory .................................................................................. 7 3.2 Test Facility .............................................................................................................. 7 3.3 Statement of the measurement uncertainty ............................................................. 7 4 Test limit .............................................................................................................................. 8 4.1 Requirement ............................................................................................................ 8 4.2 MPE Calculation Method ......................................................................................... 8 4.3 Conducted Power Results ....................................................................................... 9 4.4 Manufacturing tolerance .......................................................................................... 9 4.5 Standalone MPE Result ......................................................................................... 10 4.6 Simultaneous Transmission for MPE Result ......................................................... 10 5 Conclusion ..........................................................................................................…

Text truncated - open the document above for the full version.

Test Report

1. Antenna Description: Antenna type External antenna Model Q6 Frequency range 2400-2500MHz, 5180-5240MHz Manufacturer Shenzhen Jianida Electronics Co. Ltd. Address 4/F, 2 Building, YueTong Shitouling Industrial No.11 Huada Road Longhua New District, Shenzhen, Guangdong China ANT Peak Gain 2400-2500MHz: 2.0 dBi 5180-5240MHz: 2.05 dBi 2. Antenna Photo: 3. Test Equipment & Conditions 3.1 Test instrument VSWR is tested using Agilent E5071B connected to a hand mechanism, and the status is free space. 3.2 Test environment and methods 4.Antenna Radiation Pattern 2400MHz 2450MHz 2500MHz 5180MHz 5220MHz 5240MHz

Test Report

Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn FCC PART 15 SUBPART C TEST REPORT FCC PART 15.247 Report Reference No. .................... : FCC ID. ........................................... : CTA25112001901 2ASORQ6 Compiled by ( position+printed name+signature) . : File administrators Zoey Cao Supervised by ( position+printed name+signature) . : Project Engineer Ace Chai Approved by ( position+printed name+signature) . : RF Manager Eric Wang Date of issue .................................... : Nov. 28, 2025 Testing Laboratory Name .............. : Shenzhen CTA Testing Technology Co., Ltd. Address ............................................ : Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Applicant’s name ........................... : Shenzhen Jianida Electronics Co. Ltd. Address ............................................ : 4/F, 2 Building, YueTong Shitouling Industrial No.11 Huada Road Longhua New District, Shenzhen, Guangdong, 518000 China Test specification ........................... : Standard ........................................... : FCC Part 15.247 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description ..................... : Surveillance camera Trade Mark ....................................... : N/A Manufacturer .................................... : Shenzhen Jianida Electronics Co. Ltd. Model/Type reference ...................... : Q6 Listed Models ................................... : Q1, Q2, Q3, Q5 Modulation ....................................... : GFSK, Π/4DQPSK, 8DPSK Frequency ........................................ : From 2402MHz to 2480MHz Ratings ............................................. : DC 5.0V From external circuit Result ............................................... : PASS Report No.: CTA25112001901 Page 2 of 43 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn T E S T R E P O R T Equipment under Test : Surveillance camera Model /Type : Q6 Listed Models : Q1, Q2, Q3, Q5 Model difference : The PCB board, circuit, structure and internal of these models are the same, Only model number and colour is different for these model. Applicant : Shenzhen Jianida Electronics Co. Ltd. Address : 4/F, 2 Building, YueTong Shitouling Industrial No.11 Huada Road Longhua New District, Shenzhen, Guangdong, 518000 China Manufacturer : Shenzhen Jianida Electronics Co. Ltd. Address : 4/F, 2 Building, YueTong Shitouling Industrial No.11 Huada Road Longhua New District, Shenzhen, Guangdong, 518000 China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA25112001901 Page 3 of 43 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Contents 1 TEST STANDARDS ...................................................................................................................................... 4 2 SUMMARY .................................................................................................................................................... 5 2.1 General Remarks .............................................................................................................................. 5 2.2 Product Description ........................................................................................................................... 5 2.3 Equipment Under Test ....................................................................................................................... 5 2.4 Short description of the Equipment under Test (EUT) ...................................................................... 5 2.5 EUT configuration .............................................................................................................................. 6 2.6 EUT operation mode ......................................................................................................................... 6 2.7 Block Diagram of Test Setup ............................................................................................................. 6 2.8 Related Submittal(s) / Grant (s) ......................................................................................................... 6 2.9 Modifications ...................................................................................................................................... 6 3 TEST ENVIRONMENT ................................................................................................................................. 7 3.1 Address of the test laboratory............................................................................................................ 7 3.2 Test Facility ..................................................................................................…

Text truncated - open the document above for the full version.

Test Report

1 FCC Appendix RF Test Data for BT FCC ID : 2ASORQ6 Company : Shenzhen Jianida Electronics Co. Ltd. EUT : Surveillance camera Model Number : Q6 Report No. : CTA25112001901 Reviewed By : Eric Wang 2 Appendix A: 20dB Emission Bandwidth Test Result TestMode Antenna Freq(MHz) 20dB EBW[MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict DH5 Ant1 2402 0.945 2401.553 2402.498 --- --- 2441 0.948 2440.550 2441.498 --- --- 2480 0.954 2479.550 2480.504 --- --- 2DH5 Ant1 2402 1.332 2401.343 2402.675 --- --- 2441 1.320 2440.346 2441.666 --- --- 2480 1.311 2479.355 2480.666 --- --- 3DH5 Ant1 2402 1.281 2401.382 2402.663 --- --- 2441 1.317 2440.352 2441.669 --- --- 2480 1.326 2479.346 2480.672 --- --- 3 Test Graphs DH5_Ant1_2402 DH5_Ant1_2441 DH5_Ant1_2480 4 2DH5_Ant1_2402 2DH5_Ant1_2441 5 2DH5_Ant1_2480 3DH5_Ant1_2402 3DH5_Ant1_2441 6 3DH5_Ant1_2480 7 Appendix B: Occupied Channel Bandwidth Test Result TestMode Antenna Freq(MHz) OCB [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict DH5 Ant1 2402 0.87481 2401.5744 2402.4492 --- --- 2441 0.87575 2440.5730 2441.4488 --- --- 2480 0.87159 2479.5730 2480.4446 --- --- 2DH5 Ant1 2402 1.1940 2401.4135 2402.6075 --- --- 2441 1.1923 2440.4146 2441.6069 --- --- 2480 1.1875 2479.4173 2480.6048 --- --- 3DH5 Ant1 2402 1.1925 2401.4146 2402.6071 --- --- 2441 1.1845 2440.4188 2441.6033 --- --- 2480 1.1919 2479.4177 2480.6096 --- --- 8 Test Graphs DH5_Ant1_2402 DH5_Ant1_2441 DH5_Ant1_2480 9 2DH5_Ant1_2402 2DH5_Ant1_2441 10 2DH5_Ant1_2480 3DH5_Ant1_2402 3DH5_Ant1_2441 11 3DH5_Ant1_2480 12 Appendix C: Maximum conducted output power Test Result Peak Test Mode Antenna Freq(MHz) Conducted Peak Powert[dBm] Conducted Limit[dBm] Verdict DH5 Ant1 2402 3.71 ≤20.97 PASS 2441 3.42 ≤20.97 PASS 2480 3.34 ≤20.97 PASS 2DH5 Ant1 2402 3.02 ≤20.97 PASS 2441 2.71 ≤20.97 PASS 2480 2.62 ≤20.97 PASS 3DH5 Ant1 2402 3.01 ≤20.97 PASS 2441 2.71 ≤20.97 PASS 2480 2.64 ≤20.97 PASS 13 Appendix D: Carrier frequency separation Test Result TestMode Antenna Freq(MHz) Result[MHz] Limit[MHz] Verdict DH5 Ant1 Hop 0.992 ≥0.954 PASS 2DH5 Ant1 Hop 1.196 ≥0.888 PASS 3DH5 Ant1 Hop 1.056 ≥0.884 PASS 14 Test Graphs DH5_Ant1_Hop 2DH5_Ant1_Hop 3DH5_Ant1_Hop 15 16 Appendix E: Time of occupancy Test Result TestMode Antenna Freq(MHz) BurstWidth [ms] TotalHops [Num] Result[s] Limit[s] Verdict DH1 Ant1 Hop 0.390 317 0.124 ≤0.4 PASS DH3 Ant1 Hop 1.650 166 0.274 ≤0.4 PASS DH5 Ant1 Hop 2.890 106 0.306 ≤0.4 PASS 2DH1 Ant1 Hop 0.390 316 0.123 ≤0.4 PASS 2DH3 Ant1 Hop 1.640 159 0.261 ≤0.4 PASS 2DH5 Ant1 Hop 2.900 101 0.293 ≤0.4 PASS 3DH1 Ant1 Hop 0.390 318 0.124 ≤0.4 PASS 3DH3 Ant1 Hop 1.640 161 0.264 ≤0.4 PASS 3DH5 Ant1 Hop 2.900 110 0.319 ≤0.4 PASS 17 Test Graphs DH1_Ant1_Hop DH3_Ant1_Hop 18 DH5_Ant1_Hop 19 2DH1_Ant1_Hop 2DH3_Ant1_Hop 20 2DH5_Ant1_Hop 21 3DH1_Ant1_Hop 3DH3_Ant1_Hop 22 3DH5_Ant1_Hop 23 24 Appendix F: Number of hopping channels Test Result TestMode Antenna Freq(MHz) Result[Num] Limit[Num] Verdict DH5 Ant1 Hop 79 ≥15 PASS 2DH5 Ant1 Hop 79 ≥15 PASS 3DH5 Ant1 Hop 79 ≥15 PASS 25 Test Graphs DH5_Ant1_Hop 2DH5_Ant1_Hop 3DH5_Ant1_Hop 26 27 Appendix G: Band edge measurements Test Result TestMode Antenna ChName Freq(MHz) RefLevel [dBm] Result [dBm] Limit [dBm] Verdict DH5 Ant1 Low 2402 3.54 -48.64 ≤-16.46 PASS High 2480 2.85 -60.5 ≤-17.15 PASS Low Hop_2402 -0.22 -56.87 ≤-20.22 PASS High Hop_2480 -0.51 -63.31 ≤-20.51 PASS 2DH5 Ant1 Low 2402 -0.64 -50.33 ≤-20.64 PASS High 2480 -0.53 -54.2 ≤-20.53 PASS Low Hop_2402 0.37 -54.07 ≤-19.63 PASS High Hop_2480 -0.12 -63.43 ≤-20.12 PASS 3DH5 Ant1 Low 2402 -0.92 -49.76 ≤-20.92 PASS High 2480 -1.38 -52.86 ≤-21.38 PASS Low Hop_2402 -2.92 -54.55 ≤-22.92 PASS High Hop_2480 -1.64 -63.42 ≤-21.64 PASS 28 Test Graphs DH5_Ant1_Low_2402 DH5_Ant1_High_2480 DH5_Ant1_Low_Hop_2402 29 DH5_Ant1_High_Hop_2480 2DH5_Ant1_Low_2402 30 2DH5_Ant1_High_2480 2DH5_Ant1_Low_Hop_2402 2DH5_Ant1_High_Hop_2480 31 3DH5_Ant1_Low_2402 3DH5_Ant1_High_2480 32 3DH5_Ant1_Low_Hop_2402 3DH5_Ant1_High_Hop_2480 33 Appendix H: Conducted Spurious Emission Test Result TestMode Antenna Freq(MHz) FreqRange [MHz] RefLevel [dBm] Result [dBm] Limit [dBm] Verdict DH5 Ant1 2402 Reference 2.84 2.84 --- PASS 30~1000 2.84 -68.38 ≤-17.16 PASS 1000~26500 2.84 -38.57 ≤-17.16 PASS 2441 Reference 2.34 2.34 --- PASS 30~1000 2.34 -59.57 ≤-17.66 PASS 1000~26500 2.34 -38.2 ≤-17.66 PASS 2480 Reference 2.86 2.86 --- PASS 30~1000 2.86 -25.38 ≤-17.14 PASS 1000~26500 2.86 -38.64 ≤-17.14 PASS 2DH5 Ant1 2402 Reference -1.72 -1.72 --- PASS 30~1000 -1.72 -60.98 ≤-21.72 PASS 1000~26500 -1.72 -43.29 ≤-21.72 PASS 2441 Reference -2.64 -2.64 --- PASS 30~1000 -2.64 -39.28 ≤-22.64 PASS 1000~26500 -2.64 -45.02 ≤-22.64 PASS 2480 Reference -2.23 -2.23 --- PASS 30~1000 -2.23 -62.58 ≤-22.23 PASS 1000~26500 -2.23 -43.68 ≤-22.23 PASS 3DH5 Ant1 2402 Reference -1.47 -1.47 --- PASS 30~1000 -1.47 -58.07 ≤-21.47 PASS 1000~26500 -1.47 -43.64 ≤-21.47 PASS 2441 Reference -0.56 -0.56 --- PASS 30~1000 -0.56 -64.14 ≤-20.56 PASS 1000~26500 -0.56 -42.24 ≤-20.56 PASS 2480 Reference -1.51 -1.51 --- PASS 30~1000 -1.51 -58.81 ≤-21.51 PASS 1000~26500 -1.51 -43.45 ≤-21.51 PASS 34 Test Graphs DH5_Ant1_2402_0~Reference DH5_Ant1_2402_30~1000 DH5_Ant1_2402_1000~26500 35 DH5_Ant1_2441_0~Reference DH5_Ant1_2441_30~1000

Test Report

36 DH5_Ant1_2441_1000~26500 DH5_Ant1_2480_0~Reference DH5_Ant1_2480_30~1000 37 DH5_Ant1_2480_1000~26500 2DH5_Ant1_2402_0~Reference 38 2DH5_Ant1_2402_30~1000 2DH5_Ant1_2402_1000~26500 2DH5_Ant1_2441_0~Reference 39 2DH5_Ant1_2441_30~1000 2DH5_Ant1_2441_1000~26500 40 2DH5_Ant1_2480_0~Reference 2DH5_Ant1_2480_30~1000 2DH5_Ant1_2480_1000~26500 41 3DH5_Ant1_2402_0~Reference 3DH5_Ant1_2402_30~1000 42 3DH5_Ant1_2402_1000~26500 3DH5_Ant1_2441_0~Reference 3DH5_Ant1_2441_30~1000 43 3DH5_Ant1_2441_1000~26500 3DH5_Ant1_2480_0~Reference 44 3DH5_Ant1_2480_30~1000 3DH5_Ant1_2480_1000~26500 45 Appendix I: Duty Cycle Test Result TestMode Antenna Freq(MHz) ON Time [ms] Period [ms] DC [%] xFactor Limit Verdict DH5 Ant1 2402 2.91 3.75 77.60 1.10 --- --- 2441 2.91 3.75 77.60 1.10 --- --- 2480 2.91 3.75 77.60 1.10 --- --- 2DH5 Ant1 2402 2.91 3.75 77.60 1.10 --- --- 2441 2.92 3.75 77.87 1.09 --- --- 2480 2.91 3.75 77.60 1.10 --- --- 3DH5 Ant1 2402 2.92 3.75 77.87 1.09 --- --- 2441 2.92 3.75 77.87 1.09 --- --- 2480 2.91 3.75 77.60 1.10 --- --- 46 Test Graphs DH5_Ant1_2402 DH5_Ant1_2441 DH5_Ant1_2480 47 2DH5_Ant1_2402 2DH5_Ant1_2441 48 2DH5_Ant1_2480 3DH5_Ant1_2402 3DH5_Ant1_2441 49 3DH5_Ant1_2480

Test Setup Photos

FCC ID:2ASORQ6 Test Setup Photos of the EUT FCC ID:2ASORQ6

Contact Information

Applicant

Yusen Zhang
[email protected]Fax: N.A.

Test Firm

SHENZHEN CTA TESTING TECHNOLOGY CO., LTD.Eric Wang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.30 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is peak conducted. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.