FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. MAXWEST COMMUNICATION LIMITED/
  3. 2ASP8NITRO55Q

2ASP8NITRO55QMobile Phone

MAXWEST COMMUNICATION LIMITED
Mobile Phone - FCC ID 2ASP8NITRO55Q - MAXWEST COMMUNICATION LIMITED
Click to zoom

Application Details

Equipment Class
PCE - PCS Licensed Transmitter held to ear
Date of Grant
Nov 10, 2020
Application Purpose
Original Equipment
Date of Application
Nov 10, 2020
Equipment Note
Mobile Phone
Frequency Range
1720.00000000 - 1770.00000000
Company
MAXWEST COMMUNICATION LIMITED
Country
Hong Kong

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗
↗
↗
↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

dual Nitro 55Q 8 10.0 Switch to fornt/rear cameara Video Mode 1 Nitro 55Q . 2020 ,Gmail Take Picture Picture Review LTE LTE 3:54 PM 3:54 PM 3:54 PM 3:54 PM 3:54 PM 3:54 PM 3:54 PM 3:54 PM 3:54 PM 3:54 PM 10 10mm

Attestation Statements

MAXWEST COMMUNICATION LIMITED ADD: ROOM 1802B FORTRESS TOWER 250 KING'S ROAD NORTH POINT Hong Kong TEL: 00852-3464 9345 FAX: 00852-3007 9834 E-mail: [email protected] Date: 2020-10-17 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Dear Sir/Madam, We, MAXWEST COMMUNICATION LIMITED, hereby authorize Bay Area Compliance Laboratories Corp. to act as a laboratory for testing and test report generation for the following project(s): (Product name: Mobile Phone, Model name: Nitro 55Q,FCC ID: 2ASP8NITRO55Q) The chipset SC9832E supports LTE, but fo r this device, only band 2/4/5/12/13/17/66 were active,the other were disable by software. Sincerely, Signature: Celina He Manager

Cover Letter(s)

QA-FR-170-B MAXWEST COMMUNICATION LIMITED ADD: ROOM 1802B FORTRESS TOWER 250 KING'S ROAD NORTH POINT Hong Kong TEL: 00852-3464 9345 FAX: 00852-3007 9834 E-mail: [email protected] FCC Authorization Date: 2020-10-07 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization To whom it may concern: We , MAXWEST COMMUNICATION LIMITED, Hereby authorizes Bay Area Compliance Laboratories Corporation to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by Bay Area Compliance Laboratory Corporation on our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. This authorization is valid until further written notice from the applicant. Sincerely Yours, Client’s signature Celina He Manager

Cover Letter(s)

FCC ID:2ASP8NITRO55Q QA-FR-171-A MAXWEST COMMUNICATION LIMITED Add: ROOM 1802B FORTRESS TOWER 250 KING'S ROAD NORTH POINT Hong Kong Tel: 00852-3464 9345 FAX: 00852-3007 9834 Email: [email protected] FCC Confidential Authorization Date: 2020-10-07 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of In accordance with Sections 0.457 and 0.459 of the Commission’s Rules, (MAXWEST COMMUNICATION LIMITED) hereby requests long-term confidential treatment of information accompanying this application as outlined below: Block Diagram Schematics Operation Description Parts List/Tune up procedure (for licensed devices) The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely, Signature: Celina He Manager

External Photos

EXHIBIT B - EUT EXTERNAL PHOTOGRAPHS Adapter 1 Adapter 2

ID Label/Location Info

Diseñado en EEUU SN: NTO55Q201100001 FCC ID: 2ASP8NITRO55Q IC: 24313-NITRO55Q LTE: B2/B4/B5/B12/B17/B66 WCDMA: 850/1700/1900 GSM: 850/900/1800/1900 MODEL:

Internal Photos

EXHIBIT C - EUT INTERNAL PHOTOGRAPHS 2G/3G/4G Main Antenna LTE Aux Antenna Wifi/BT Antenna

RF Exposure Info

Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Dongguan). This report must not be used by the customer to claim product certification, approval, or endorsement by A2LA* or any agency of the Federal Government. * This report may contain data that are not covered by the A2LA accreditation and are marked with an asterisk “*”. SAR EVALUATION REPORT For MAXWEST COMMUNICATION LIMITED ROOM 1802B FORTRESS TOWER, 250 KING'S ROAD, NORTH POINT, HONG KONG FCC ID: 2ASP8NITRO55Q Report Type: Original Report Product Type: Mobile Phone Report Number: RDG200918006-20A Report Date: 2020-10-30 Reviewed By: Rocky Xiao RF Engineer Prepared By: Bay Area Compliance Laboratories Corp. (Dongguan) No.69 Pulongcun, Puxinhu Industry Area, Tangxia, Dongguan, Guangdong, China Tel: +86-769-86858888 Fax: +86-769-86858891 www.baclcorp.com.cn Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG200918006-20A SAR Evaluation Report 2 of 80 Attestation of Test Results EUT Information EUT Description Mobile Phone Tested Model Nitro 55Q FCC ID 2ASP8NITRO55Q Serial Number RDG200918006-SA-S1 Test Date 2020-09-18~2020-09-23 MODE Max. SAR Level(s) Reported(W/kg) Limit (W/kg) GSM 850 1g Head SAR 0.05 1.6 1g Body SAR 0.12 PCS 1900 1g Head SAR 0.09 1g Body SAR 0.40 WCDMA Band 2 1g Head SAR 0.18 1g Body SAR 0.73 WCDMA Band 4 1g Head SAR 0.37 1g Body SAR 0.67 WCDMA Band 5 1g Head SAR 0.04 1g Body SAR 0.08 LTE Band 2 1g Head SAR 0.33 1g Body SAR 0.74 LTE Band 5 1g Head SAR 0.12 1g Body SAR 0.08 LTE Band 12&17 1g Head SAR 0.07 1g Body SAR 0.20 LTE Band 66&4 1g Head SAR 0.27 1g Body SAR 0.68 WLAN 2.4G 1g Head SAR 0.10 1g Body SAR 0.03 Simultaneous 1g Head SAR 0.54 1g Body SAR 0.83 1g Body SAR 0.77 (Hotspot) Applicable Standards FCC 47 CFR part 2.1093 Radiofrequency radiation exposure evaluation: portable devices RF Exposure Procedures: TCB Workshop April 2019 IEEE1528:2013 IEEE Recommended Practice for Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement Techniques IEC 62209-1:2016 Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices – Part 1: Devices used next to the ear (Frequenc y range of 300 MHz to 6 GHz) KDB procedures KDB 447498 D01 General RF Exposure Guidance v06 KDB 648474 D04 Handset SAR v01r03 KDB 865664 D01 SAR Measurement 100 MHz to 6 GHz v01r04 KDB 865664 D02 RF Exposure Reporting v01r02 KDB 941225 D01 3G SAR Procedures v03r01 KDB 941225 D05 SAR for LTE Devices v02r05 KDB 941225 D06 Hotspot Mode v02r01 KDB 248227 D01 802 11 Wi-Fi SAR v02r02 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG200918006-20A SAR Evaluation Report 3 of 80 Note: This wireless device has been shown to be capable of compliance for localized specific absorption rate (SAR) for General Population/Uncontrolled Exposure limits specified in FCC 47 CFR part 2.1093 and has been tested in accordance with the measurement procedures specified in IEEE 1528-2013 and RF exposure KDB procedures. The results and statements contained in this report pertain only to the device(s) evaluated. Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG200918006-20A SAR Evaluation Report 4 of 80 TABLE OF CONTENTS DOCUMENT REVISION HISTORY ......................................................................................................................... 5 EUT DESCRIPTION .................................................................................................................................................... 6 TECHNICAL SPECIFICATION ......................................................................................................................................... 6 REFERENCE, STANDARDS, AND GUIDELINES .................................................................................................. 7 SAR LIMITS ................................................................................................................................................................. 8 FACILITIES .................................................................................................................................................................. 9 DESCRIPTION OF TEST SYSTEM ........................................................................................................................ 10 EQUIPMENT LIST AND CALIBRATION ............................................................................................................. 16 EQUIPMENTS LIST & CALIBRATION INFORMATION .................................................................................................... 16 SAR MEASUREMENT SYSTEM VERIFICATION .............................................................................................. 17 LIQUID VERIFICATION ............................................................................................................................................... 17 SYSTEM ACCURACY VERIFICATION ........................................................................................................................... 19 SAR SYSTEM VALIDATION DATA ..................................................................................................................... 20 EUT TEST STRATEGY AND METHODOLOGY ................................................................................................. 26 TEST POSITIONS FOR DEVICE OPERATING NEXT TO A PERSON’S EAR........................................................................ 26 CHEEK/TOUCH POSITION ........................................................................................................................................... 27 EAR/TILT POSITION ......................................…

Text truncated - open the document above for the full version.

RF Exposure Info

APPENDIX C PROBE CALIBRATION CERTIFICATES DIPOLE CALIBRATION CERTIFICATES

RF Exposure Info

Report No.: RDG200918006-20A Page 1 of 149 Test Plot1#: GSM 850_Head Left Cheek_Mid DUT: Mobile Phone; Type: Nitro 55Q; Serial: RDG200918006-SA-S1 Communication System: Generic GSM; Frequency: 836.6 MHz;Duty Cycle: 1:8 Medium parameters used: f = 836.6 MHz; σ = 0.918 S/m; ε r = 41.502; ρ = 1000 kg/m 3 Phantom section: Left Section DASY5 Configuration:  Probe: EX3DV4 - SN7329; ConvF(9.97, 9.97, 9.97) @ 836.6 MHz; Calibrated: 2019/10/22  Sensor-Surface: 1.4mm (Mechanical Surface Detection)  Electronics: DAE4 Sn772; Calibrated: 2019/10/6  Phantom: SAM (30deg probe tilt) with CRP v5.0_20150321; Type: QD000P40CD; Serial: TP:1874  Measurement SW: DASY52, Version 52.10 (2); SEMCAD X Version 14.6.12 (7470) Area Scan (71x111x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 0.0388 W/kg Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 2.712 V/m; Power Drift = -0.03 dB Peak SAR (extrapolated) = 0.0440 W/kg SAR(1 g) = 0.034 W/kg; SAR(10 g) = 0.027 W/kg Maximum value of SAR (measured) = 0.0394 W/kg 0 dB = 0.0394 W/kg = -14.05 dBW/kg Report No.: RDG200918006-20A Page 2 of 149 Test Plot2#: GSM 850_Head Left Tilt_Mid DUT: Mobile Phone; Type: Nitro 55Q; Serial: RDG200918006-SA-S1 Communication System: Generic GSM; Frequency: 836.6 MHz;Duty Cycle: 1:8 Medium parameters used: f = 836.6 MHz; σ = 0.918 S/m; ε r = 41.502; ρ = 1000 kg/m 3 Phantom section: Left Section DASY5 Configuration:  Probe: EX3DV4 - SN7329; ConvF(9.97, 9.97, 9.97) @ 836.6 MHz; Calibrated: 2019/10/22  Sensor-Surface: 1.4mm (Mechanical Surface Detection)  Electronics: DAE4 Sn772; Calibrated: 2019/10/6  Phantom: SAM (30deg probe tilt) with CRP v5.0_20150321; Type: QD000P40CD; Serial: TP:1874  Measurement SW: DASY52, Version 52.10 (2); SEMCAD X Version 14.6.12 (7470) Area Scan (71x111x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 0.0255 W/kg Zoom Scan (6x7x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 3.403 V/m; Power Drift = 0.01 dB Peak SAR (extrapolated) = 0.0270 W/kg SAR(1 g) = 0.022 W/kg; SAR(10 g) = 0.018 W/kg Maximum value of SAR (measured) = 0.0256 W/kg 0 dB = 0.0256 W/kg = -15.92 dBW/kg Report No.: RDG200918006-20A Page 3 of 149 Test Plot3#: GSM 850_Head Right Cheek_Mid DUT: Mobile Phone; Type: Nitro 55Q; Serial: RDG200918006-SA-S1 Communication System: Generic GSM; Frequency: 836.6 MHz;Duty Cycle: 1:8 Medium parameters used: f = 836.6 MHz; σ = 0.918 S/m; ε r = 41.502; ρ = 1000 kg/m 3 Phantom section: Right Section DASY5 Configuration:  Probe: EX3DV4 - SN7329; ConvF(9.97, 9.97, 9.97) @ 836.6 MHz; Calibrated: 2019/10/22  Sensor-Surface: 1.4mm (Mechanical Surface Detection)  Electronics: DAE4 Sn772; Calibrated: 2019/10/6  Phantom: SAM (30deg probe tilt) with CRP v5.0_20150321; Type: QD000P40CD; Serial: TP:1874  Measurement SW: DASY52, Version 52.10 (2); SEMCAD X Version 14.6.12 (7470) Area Scan (61x121x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 0.0535 W/kg Zoom Scan (6x6x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 3.070 V/m; Power Drift = -0.15 dB Peak SAR (extrapolated) = 0.0560 W/kg SAR(1 g) = 0.042 W/kg; SAR(10 g) = 0.033 W/kg Maximum value of SAR (measured) = 0.0504 W/kg 0 dB = 0.0504 W/kg = -12.98 dBW/kg Report No.: RDG200918006-20A Page 4 of 149 Test Plot4#: GSM 850_Head Right Tilt_Mid DUT: Mobile Phone; Type: Nitro 55Q; Serial: RDG200918006-SA-S1 Communication System: Generic GSM; Frequency: 836.6 MHz;Duty Cycle: 1:8 Medium parameters used: f = 836.6 MHz; σ = 0.918 S/m; ε r = 41.502; ρ = 1000 kg/m 3 Phantom section: Right Section DASY5 Configuration:  Probe: EX3DV4 - SN7329; ConvF(9.97, 9.97, 9.97) @ 836.6 MHz; Calibrated: 2019/10/22  Sensor-Surface: 1.4mm (Mechanical Surface Detection)  Electronics: DAE4 Sn772; Calibrated: 2019/10/6  Phantom: SAM (30deg probe tilt) with CRP v5.0_20150321; Type: QD000P40CD; Serial: TP:1874  Measurement SW: DASY52, Version 52.10 (2); SEMCAD X Version 14.6.12 (7470) Area Scan (61x121x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 0.0275 W/kg Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 4.136 V/m; Power Drift = 0.08 dB Peak SAR (extrapolated) = 0.0290 W/kg SAR(1 g) = 0.023 W/kg; SAR(10 g) = 0.019 W/kg Maximum value of SAR (measured) = 0.0265 W/kg 0 dB = 0.0265 W/kg = -15.77 dBW/kg Report No.: RDG200918006-20A Page 5 of 149 Test Plot5#: GSM 850_Body Worn Back_Low DUT: Mobile Phone; Type: Nitro 55Q; Serial: RDG200918006-SA-S1 Communication System: Generic GSM; Frequency: 824.2 MHz;Duty Cycle: 1:8 Medium parameters used: f = 824.2 MHz; σ = 0.904 S/m; ε r = 41.584; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY5 Configuration:  Probe: EX3DV4 - SN7329; ConvF(9.97, 9.97, 9.97) @ 824.2 MHz; Calibrated: 2019/10/22  Sensor-Surface: 1.4mm (Mechanical Surface Detection)  Electronics: DAE4 Sn772; Calibrated: 2019/10/6  Phantom: SAM (30deg probe tilt) with CRP v5.0_20150321; Type: QD000P40CD; Serial: TP:1874  Measurement SW: DASY52, Version 52.10 (2); SEMCAD X Version 14.6.12 (7470) Area Scan (61x121x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 0.113 W/kg Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 10.18 V/m; Power Drift = -0.06 dB Peak SAR (extrapolated) = 0.161 W/kg SAR(1 g) = 0.082 W/kg; SAR(10 g) = 0.047 W/kg Maximum value of SAR (measured) = 0.127 W/kg 0 dB = 0.127 W/kg = -8.96 dBW/kg Report No.: RDG200918006-20A Page 6 of 149 Test Plot6#: GSM 850_Body Worn Back_Mid DUT: Mobile Phone; Type: Nitro 55Q; Serial: RDG200918006-SA-S1 Communication System: Generic GSM; Frequency: 836.6 MHz;Duty Cycle: 1:8 Medium parameters used: f = 836.6 MHz; σ = 0.918 S/m; ε r = 41.502; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY5 Configuration:  Probe: EX3DV4 - SN7329; ConvF(9.97, 9.97, 9.97) @ 836.6 MHz; Calibrated: 2019/10/22  …

Text truncated - open the document above for the full version.

RF Exposure Info

Report No.: RDG200918006-20A Page 81 of 149 Test Plot81#: LTE Band 5_1RB_Head Left Cheek_Mid DUT: Mobile Phone; Type: Nitro 55Q; Serial: RDG200918006-SA-S1 Communication System: Generic FDD-LTE; Frequency: 836.5 MHz;Duty Cycle: 1:1 Medium parameters used: f = 836.5 MHz; σ = 0.915 S/m; ε r = 41.521; ρ = 1000 kg/m 3 Phantom section: Left Section DASY5 Configuration:  Probe: EX3DV4 - SN7329; ConvF(9.97, 9.97, 9.97) @ 836.5 MHz; Calibrated: 2019/10/22  Sensor-Surface: 1.4mm (Mechanical Surface Detection)  Electronics: DAE4 Sn772; Calibrated: 2019/10/6  Phantom: SAM (30deg probe tilt) with CRP v5.0_20150321; Type: QD000P40CD; Serial: TP:1874  Measurement SW: DASY52, Version 52.10 (2); SEMCAD X Version 14.6.12 (7470) Area Scan (71x111x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 0.110 W/kg Zoom Scan (5x6x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 2.876 V/m; Power Drift = 0.07 dB Peak SAR (extrapolated) = 0.114 W/kg SAR(1 g) = 0.109 W/kg; SAR(10 g) = 0.101 W/kg Maximum value of SAR (measured) = 0.112 W/kg 0 dB = 0.112 W/kg = -9.51 dBW/kg Report No.: RDG200918006-20A Page 82 of 149 Test Plot82#: LTE Band 5_1RB_Head Left Cheek_High DUT: Mobile Phone; Type: Nitro 55Q; Serial: RDG200918006-SA-S1 Communication System: Generic FDD-LTE; Frequency: 844 MHz;Duty Cycle: 1:1 Medium parameters used: f = 844 MHz; σ = 0.921 S/m; ε r = 41.487; ρ = 1000 kg/m 3 Phantom section: Left Section DASY5 Configuration:  Probe: EX3DV4 - SN7329; ConvF(9.97, 9.97, 9.97) @ 844 MHz; Calibrated: 2019/10/22  Sensor-Surface: 1.4mm (Mechanical Surface Detection)  Electronics: DAE4 Sn772; Calibrated: 2019/10/6  Phantom: SAM (30deg probe tilt) with CRP v5.0_20150321; Type: QD000P40CD; Serial: TP:1874  Measurement SW: DASY52, Version 52.10 (2); SEMCAD X Version 14.6.12 (7470) Area Scan (71x111x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 0.0552 W/kg Zoom Scan (5x6x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 1.817 V/m; Power Drift = 0.06 dB Peak SAR (extrapolated) = 0.0580 W/kg SAR(1 g) = 0.055 W/kg; SAR(10 g) = 0.051 W/kg Maximum value of SAR (measured) = 0.0566 W/kg 0 dB = 0.0566 W/kg = -12.47 dBW/kg Report No.: RDG200918006-20A Page 83 of 149 Test Plot 83#: LTE Band 5_50%RB_Head Left Cheek_Mid DUT: Mobile Phone; Type: Nitro 55Q; Serial: RDG200918006-SA-S1 Communication System: Generic FDD-LTE; Frequency: 836.5 MHz;Duty Cycle: 1:1 Medium parameters used: f = 836.5 MHz; σ = 0.915 S/m; ε r = 41.521; ρ = 1000 kg/m 3 Phantom section: Left Section DASY5 Configuration:  Probe: EX3DV4 - SN7329; ConvF(9.97, 9.97, 9.97) @ 836.5 MHz; Calibrated: 2019/10/22  Sensor-Surface: 1.4mm (Mechanical Surface Detection)  Electronics: DAE4 Sn772; Calibrated: 2019/10/6  Phantom: SAM (30deg probe tilt) with CRP v5.0_20150321; Type: QD000P40CD; Serial: TP:1874  Measurement SW: DASY52, Version 52.10 (2); SEMCAD X Version 14.6.12 (7470) Area Scan (71x111x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 0.0794 W/kg Zoom Scan (6x6x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 2.572 V/m; Power Drift = -0.06 dB Peak SAR (extrapolated) = 0.0798 W/kg SAR(1 g) = 0.077 W/kg; SAR(10 g) = 0.072 W/kg Maximum value of SAR (measured) = 0.0781 W/kg 0 dB = 0.0781 W/kg = -11.07 dBW/kg Report No.: RDG200918006-20A Page 84 of 149 Test Plot84#: LTE Band 5_1RB_Head Left Tilt_Mid DUT: Mobile Phone; Type: Nitro 55Q; Serial: RDG200918006-SA-S1 Communication System: Generic FDD-LTE; Frequency: 836.5 MHz;Duty Cycle: 1:1 Medium parameters used: f = 836.5 MHz; σ = 0.915 S/m; ε r = 41.521; ρ = 1000 kg/m 3 Phantom section: Left Section DASY5 Configuration:  Probe: EX3DV4 - SN7329; ConvF(9.97, 9.97, 9.97) @ 836.5 MHz; Calibrated: 2019/10/22  Sensor-Surface: 1.4mm (Mechanical Surface Detection)  Electronics: DAE4 Sn772; Calibrated: 2019/10/6  Phantom: SAM (30deg probe tilt) with CRP v5.0_20150321; Type: QD000P40CD; Serial: TP:1874  Measurement SW: DASY52, Version 52.10 (2); SEMCAD X Version 14.6.12 (7470) Area Scan (71x111x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 0.0890 W/kg Zoom Scan (5x6x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 7.945 V/m; Power Drift = -0.13 dB Peak SAR (extrapolated) = 0.0950 W/kg SAR(1 g) = 0.081 W/kg; SAR(10 g) = 0.076 W/kg Maximum value of SAR (measured) = 0.0836 W/kg 0 dB = 0.0836 W/kg = -10.78 dBW/kg Report No.: RDG200918006-20A Page 85 of 149 Test Plot85#: LTE Band 5_50%RB_Head Left Tilt_Mid DUT: Mobile Phone; Type: Nitro 55Q; Serial: RDG200918006-SA-S1 Communication System: Generic FDD-LTE; Frequency: 836.5 MHz;Duty Cycle: 1:1 Medium parameters used: f = 836.5 MHz; σ = 0.915 S/m; ε r = 41.521; ρ = 1000 kg/m 3 Phantom section: Left Section DASY5 Configuration:  Probe: EX3DV4 - SN7329; ConvF(9.97, 9.97, 9.97) @ 836.5 MHz; Calibrated: 2019/10/22  Sensor-Surface: 1.4mm (Mechanical Surface Detection)  Electronics: DAE4 Sn772; Calibrated: 2019/10/6  Phantom: SAM (30deg probe tilt) with CRP v5.0_20150321; Type: QD000P40CD; Serial: TP:1874  Measurement SW: DASY52, Version 52.10 (2); SEMCAD X Version 14.6.12 (7470) Area Scan (71x111x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 0.0550 W/kg Zoom Scan (6x6x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 4.067 V/m; Power Drift = 0.12 dB Peak SAR (extrapolated) = 0.0570 W/kg SAR(1 g) = 0.053 W/kg; SAR(10 g) = 0.048 W/kg Maximum value of SAR (measured) = 0.0556 W/kg 0 dB = 0.0556 W/kg = -12.55 dBW/kg Report No.: RDG200918006-20A Page 86 of 149 Test Plot86#: LTE Band 5_1RB_Head Right Cheek_Mid DUT: Mobile Phone; Type: Nitro 55Q; Serial: RDG200918006-SA-S1 Communication System: Generic FDD-LTE; Frequency: 836.5 MHz;Duty Cycle: 1:1 Medium parameters used: f = 836.5 MHz; σ = 0.915 S/m; ε r = 41.521; ρ = 1000 kg/m 3 Phantom section: Right Section DASY5 Configuration:  Probe: EX…

Text truncated - open the document above for the full version.

RF Exposure Info

Report No.: RDG200918006-20A Page 1 of 6 APPENDIX B EUT TEST POSITION PHOTOS Liquid depth ≥ 15cm Phantom: SAM (30deg probe tilt) with CRP v5.0_20150321; Type: QD000P40CD; Serial: TP:1874 Report No.: RDG200918006-20A Page 2 of 6 Head Left Cheek Setup Photo Head Left Tilt Setup Photo Report No.: RDG200918006-20A Page 3 of 6 Head Right Cheek Setup Photo Head Right Tilt Setup Photo Report No.: RDG200918006-20A Page 4 of 6 Body (Worn) Back Setup Photo (10mm) Body (Worn) Front Setup Photo (10mm) 10 mm 10 mm Report No.: RDG200918006-20A Page 5 of 6 Body Left Setup Photo (10mm) Body Right Setup Photo (10mm) 10mm 10mm Report No.: RDG200918006-20A Page 6 of 6 Body Bottom Setup Photo (10mm) Body Top Setup Photo (10mm) 10mm 10mm

Test Report

FCC PART 22H, PART 24E,PART 27 MEASUREMENT AND TEST REPORT For MAXWEST COMMUNICATION LIMITED ROOM 1802B FORTRESS TOWER, 250 KING'S ROAD, NORTH POINT, HONG KONG Report Type: Original Report Product Type: Mobile Phone Re port Number: RDG200918006-00D Re port Date: 2020-10-23 Reviewed B y: Ivan Cao Assistant Manager Test Laboratory: Bay Area Compliance Laboratories Corp. (Dongguan) No.69 Pulongcun, Puxinhu Industry Area, Tangxia, Dongguan, Guangdong, China Tel: +86-769-86858888 Fax: +86-769-86858891 www.baclcorp.com.cn FCC ID: 2ASP8NITRO55Q Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG200918006-00D Page 2 of 158 TABLE OF CONTENTS GENERAL INFORMATION ....................................................................................................................................... 4 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ..................................................................................... 4 OBJECTIVE ................................................................................................................................................................... 4 RELATED SUBMITTAL(S)/GRANT(S) ............................................................................................................................. 4 TEST METHODOLOGY .................................................................................................................................................. 5 MEASUREMENT UNCERTAINTY .................................................................................................................................... 5 TEST FACILITY ............................................................................................................................................................. 5 DECLARATIONS ............................................................................................................................................................ 6 SYSTEM TEST CONFIGURATION .......................................................................................................................... 7 JUSTIFICATION ............................................................................................................................................................. 7 EQUIPMENT MODIFICATIONS ....................................................................................................................................... 8 SUPPORT EQUIPMENT LIST AND DETAILS .................................................................................................................... 8 CONFIGURATION OF TEST SETUP ................................................................................................................................. 8 BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................ 8 SUMMARY OF TEST RESULTS ............................................................................................................................... 9 FCC §1.1310 & §2.1093- RF EXPOSURE .................................................................................................................. 10 APPLICABLE STANDARD ............................................................................................................................................ 10 TEST RESULT ............................................................................................................................................................. 10 FCC §2.1047 - MODULATION CHARACTERISTIC ............................................................................................ 11 FCC § 2.1046, § 22.913 (A) & § 24.232 (C) & § 27.50- RF OUTPUT POWER ...................................................... 12 APPLICABLE STANDARD ............................................................................................................................................ 12 TEST PROCEDURE ...................................................................................................................................................... 13 TEST EQUIPMENT LIST AND DETAILS ......................................................................................................................... 18 TEST DATA ................................................................................................................................................................ 18 FCC §2.1049, §22.917, §22.905 & §24.238 & §27.53- OCCUPIED BANDWIDTH ............................................... 37 APPLICABLE STANDARD ............................................................................................................................................ 37 TEST PROCEDURE ...................................................................................................................................................... 37 TEST EQUIPMENT LIST AND DETAILS ......................................................................................................................... 37 TEST DATA ................................................................................................................................................................ 37 FCC §2.1051, §22.917(A) & §24.238(A) & §27.53- SPURIOUS EMISSIONS AT ANTENNA TERMINALS ... 76 APPLICABLE STANDARD ............................................................................................................................................ 76 TEST PROCEDURE ...................................................................................................................................................... 76 TEST EQUIPMENT LIST AND DETAILS ......................................................................................................................... 76 TEST DATA ......................................................................................................................................…

Text truncated - open the document above for the full version.

Test Report

Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG200918006-00D Page 101 of 158 10M, QPSK, Low Channel Att 25 dB 829.28 MHz * 829.28 MHz A 829.28 MHz * 829.28 MHz 3DB 829.28 MHz RBW 100 kHz 829.28 MHz SWT 100 ms 829.28 MHz * 829.28 MHz VBW 300 kHz 829.28 MHz Ref 20 dBm 829.28 MHz Offset 4.5 dB 829.28 MHz LVL 829.28 MHz Start 30 MHz 829.28 MHz Stop 1 GHz 829.28 MHz 97 MHz/ 829.28 MHz 829.28 MHz 829.28 MHz 829.28 MHz 829.28 MHz 829.28 MHz 829.28 MHz 829.28 MHz 829.28 MHz 829.28 MHz 829.28 MHz 829.28 MHz 1 PK 829.28 MHz MAXH 829.28 MHz -80 -70 -60 -50 -40 -30 -20 -10 0 10 20 829.28 MHz 1 Marker 1 [T1 ] -39.18 dB m 829.280000000 MHz D1 -13 dBm MARKER 1 829.28 MHz Date: 16.OCT.2020 09:46:50 A * 3DB RBW 1 MHz SWT 55 ms * VBW 3 MHz Att 30 dB * Ref 20 dBm Offset 4.5 dB LVL Start 1 GHzStop 10 GHz900 MHz/ 1 PK MAXH -80 -70 -60 -50 -40 -30 -20 -10 0 10 20 1 Marker 1 [T1 ] -41.88 dB m 3.178000000 GHz D1 -13 dBm Date: 16.OCT.2020 09:47:15 10M, QPSK, Middle Channel A * 3DB RBW 100 kHz SWT 100 ms * VBW 300 kHz Att 25 dB * Ref 20 dBm Offset 4.5 dB LVL Start 30 MHzStop 1 GHz97 MHz/ 1 PK MAXH -80 -70 -60 -50 -40 -30 -20 -10 0 10 20 1 Marker 1 [T1 ] -53.89 dB m 988.360000000 MHz D1 -13 dBm Date: 16.OCT.2020 09:13:42 A * 3DB RBW 1 MHz SWT 55 ms * VBW 3 MHz Att 30 dB * Ref 20 dBm Offset 4.5 dB LVL Start 1 GHzStop 10 GHz900 MHz/ 1 PK MAXH -80 -70 -60 -50 -40 -30 -20 -10 0 10 20 1 Marker 1 [T1 ] -39.67 dB m 3.160000000 GHz D1 -13 dBm Date: 16.OCT.2020 09:13:56 10M, QPSK, High Channel A 842.86 MHz * 842.86 MHz 3DB 842.86 MHz RBW 100 kHz 842.86 MHz SWT 100 ms 842.86 MHz * 842.86 MHz VBW 300 kHz 842.86 MHz Att 25 dB 842.86 MHz * 842.86 MHz Ref 20 dBm 842.86 MHz Offset 4.5 dB 842.86 MHz LVL 842.86 MHz Start 30 MHz 842.86 MHz Stop 1 GHz 842.86 MHz 97 MHz/ 842.86 MHz 842.86 MHz 842.86 MHz 842.86 MHz 842.86 MHz 842…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Rita Yu
[email protected]0086-755-83453835Fax: 0086-755-83453835

Test Firm

Bay Area Compliance Laboratories Corp.(Dongguan)David Zhang
[email protected]0086 0769 86858888

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
31271.72 GHz - 1.77 GHz100.00 mW18M1D7W2.5 ppm
Confidentiality
Long Term
Grant Notes
Output power listed is ERP for operation below 1 GHz and EIRP for operation above 1 GHz. LTE supports 1.4/3/5/10/15/20 MHz BW modes in Band 2/4/66, 1.4/3/5/10 MHz BW modes in Band 5/12, and 5/10 MHz BW modes in Band 17. The antenna(s) used for this transmitter must not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 10 mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, product specific, and simultaneous transmission exposure conditions are 0.37 W/kg, 0.74 W/kg, 0.77 W/kg, and 0.83 W/kg, respectively. This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations.

Other Applications from MAXWEST COMMUNICATION LIMITED

2ASP8GRAVITYG64

Phone

Sep 29, 2024

Equipment Class

PCE - PCS Licensed Transmitter held to ear
2ASP8NITROG55

Phone

Sep 19, 2024

Equipment Class

PCE - PCS Licensed Transmitter held to ear
2ASP8ASTRO6T

Phone

Aug 01, 2024

Equipment Class

PCE - PCS Licensed Transmitter held to ear
Phone - FCC ID 2ASP8GRAVITYG65 - MAXWEST COMMUNICATION LIMITED
2ASP8GRAVITYG65

Phone

Feb 04, 2024

Equipment Class

DTS - Digital Transmission System
Phone - FCC ID 2ASP8ASTROA63 - MAXWEST COMMUNICATION LIMITED
2ASP8ASTROA63

Phone

Sep 18, 2023

Equipment Class

PCE - PCS Licensed Transmitter held to ear