FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Casetagram Limited/
  3. 2ASRV-232039FR

2ASRV-232039FRPOWERTHRU TM POWER BANK

Casetagram Limited
POWERTHRU TM POWER BANK - FCC ID 2ASRV-232039FR - Casetagram Limited
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Jul 09, 2023
Application Purpose
Original Equipment
Date of Application
Jul 09, 2023
Equipment Note
POWERTHRU TM POWER BANK
Frequency Range
0.11050000 - 0.14800000
Company
Casetagram Limited
Country
Hong Kong

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗
↗
↗
↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗
↗

ID Label/Location Info

↗

Internal Photos

↗
↗

RF Exposure Info

↗
↗

Test Report

↗
↗
↗
↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

FCC ID: 2ASRV-232039FR IC: 26753-232039FR NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC RF Exposure Warning Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment can be used in portable exposure conditions. CAN ICES-3 (B) / NMB-3 (B) This Class B digital apparatus complies with Canadian ICES-003. (Cet appareil numérique de la Classe B conforme à la norme NMB-003 du Canada). This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence- exempt RSS(s). Operation is subject to the following two conditions: (1) This device may not cause interference. (2) This device must accept any interference, including interference that may cause undesired operation of the device. L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d’Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes: (1) L’ appareil ne doit pas produire de brouillage; (2) L’ appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’ en compromettre le fonctionnement. Radio Frequency Exposure Statement for IC: This equipment complies with IC exposur e limits set forth for an uncontrolled environment. This equipment can be used in portable exposure conditions. Déclaration d’exposition aux radiofréquences pour IC: Cet équipement est conforme aux limites d’exposition IC établies pour un environnement non contrôlé. Cet équipement peut être utilisé dans des conditions d’exposition portables. NCC 警示 語: NCC警語 取得審驗證明之低功率射頻器材, 非經核准,公司、商號或使用者均不得擅自 變更頻率、加大功率或變更原設計之特性及功能。 低功率射頻器材之使用不得影響飛航安全及干擾合法通信;經發現有干擾現 象時, 應立即停用,並改善至無干擾時方得繼續使用。 前述合法通信,指依電信管理法規定作業之無線電通信。 低功率射頻器材須忍受合法通信或工業、科學及醫療用電波輻射性電機 設備之干擾。 Without permission granted by the NCC, any company, enterprise, or user is not allowed to change frequency, enhance transmitting power or alter original characteristic as well as performance to a approved low power radio-frequency devices. The low power radio-frequency devices shall not influence aircraft security and interfere legal communications; If found, the user shall cease operating immediately until no interference is achieved. The said legal communications means radio communications is operated in compliance with the Telecommunications Management A ct. The low power radio-frequency devices must be susceptible with the interference from legal communications or ISM radio wave radiated devices. WARNING: Cancer & Reproductive Harm www.P65Warnings.ca.gov The Power Bank will generate heat when charging. Provide adequate ventilation and do not cover the device while in operation. Do not subject the Power Bank to mechanical shock, do not drop it, and do not put excessive weight on it. Do not disassemble or modify the product or attempt to replace any part of it. All products have undergone thorough quality assurance inspections. If your product is excessively hot, emitting an odor, deformed, abraded, cut, or experiencing an abnormal phenomenon, immediately stop using it and contact the manufacturer. Company name:Westside Lab, Inc Address: 3705 W Pico Blvd #2637Los Angeles, CA 90019 Tel: 415-735-5423 E-mail: [email protected] POWERTHRU™ POWER BANK MAGSAFE COMPATIBLE 磁吸移動電源 User Manual | ユーザーガイド | 使用說明 使用说明 | 사용 가이드 | คู่ มือการใช้ งาน PACKAGE CONTENTS 1 PowerThru™ Power Bank MagSafe Compa tible 1 User Guide 內容物 1 PowerThru™ MagSafe 兼容 行動電源 1 使用說明書 內容物 1 PowerThru™ MagSafe 兼容 行动电源 1 使用说明书 内容 1 PowerThru™ Power Bank MagSafe対応 1 ユーザーガイド 내용물 1 PowerThru™맥세이프 보조배터리 1 이용 가이드 เนื้อหา 1 พาวเวอร์แบงค์ PowerThru™ รองรับ MagSafe 1 คู่มือการใช้งาน INSTRUCTIONS Before Use Make sure to charge your CASETiFY PowerThru™ Power Bank * Adapter not included Step 1 Wireless Charging Simply place CASETiFY PowerThru™ Power Bank behind a MagSafe compatible mobile device or phone case, and the device will charge automatically. Step 2 Wired Charging Connect the CASETiFY PowerThru™ Power Bank to mobile devices using a charging cable. Step 3 *USB-C 使用方法 使用前 CASETiFY PowerThru™ Power Bankを必ず充電してください。 * アダプターは含まれません ワイヤレス充電 CASETiFY PowerThru™ パワー バンクをMagSafe対応のモバイ ル機器やスマホケースの後ろに 置くだけで、機器が自動的に充 電されます。 有線充電 CASETiFY PowerThru™ パワーバ ンクを充電ケーブルでモバイル機 器に接続します。 ステップ 1 ステップ 2 ステップ 3 *USB-C SPECIFICATIONS Model No CTF-T-ATE-232039FREBLK Battery Capacity 5000mAh (19Wh) Input (USB-C) 5V 3A / 9V 2A / 12V 1.5A Output (USB-C)5V 3…

Text truncated - open the document above for the full version.

Cover Letter(s)

Casetagram Limited 18/F, NEO, 123 Hoi Bun Road, Kwun Tong, Hong Kong Declaration Letter Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 7/7/2023 FCC ID: 2ASRV-232039FR Pursuant to KDB 680106 of the Casetagram Limited. Hereby declare our product which is an inductive wireless power transfer applications that meet all of the following requirements are not required to submit a KDB inquiry for devices approved usinga PAG for equipment approved using certification to address RF exposure compliance. 1) Power transfer frequency is 0.1105-0.148MHz which is less than1 MHz 2) Output power from single primary coil is equal to 10 watts max 3) The system consist of one source primary coils, charging one clients. 4) Client device is placed directly in contact with the transmitter 5) The EUT is a mobile and Portable device. 6) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit. Yours sincerely, Company Officer: Simon Chan Telephone Number: +852-96412755 Email:[email protected]

Cover Letter(s)

Casetagram Limited 18/F, NEO, 123 Hoi Bun Road, Kwun Tong, Hong Kong Agent Authorization Company: Casetagram Limited Address: 18/F, NEO, 123 Hoi Bun Road, Kwun Tong, Hong Kong Product Name: POWERTHRU TM POWER BANK Model Number(s): CTF-T-ATE-232039FREBLK Product Description: POWERTHRU TM POWER BANK We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: Jun. 25, 2023 Name: Simon Chan Title: General Manager Company: Casetagram Limited

Cover Letter(s)

Casetagram Limited 18/F, NEO, 123 Hoi Bun Road, Kwun Tong, Hong Kong Declaration Letter Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 7/7/2023 FCC ID: 2ASRV-232039FR Pursuant to KDB 680106 of the Casetagram Limited. Hereby declare our product which is an inductive wireless power transfer applications that meet all of the following requirements are not required to submit a KDB inquiry for devices approved usinga PAG for equipment approved using certification to address RF exposure compliance. 1) Power transfer frequency is 0.1105-0.148MHz which is less than1 MHz 2) Output power from single primary coil is equal to 10 watts max 3) The system consist of one source primary coils, charging one clients. 4) Client device is placed directly in contact with the transmitter 5) The EUT is a mobile and Portable device. 6) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit. Yours sincerely, Company Officer: Simon Chan Telephone Number: +852-96412755 Email:[email protected]

External Photos

Report No.: AGC02129230401AP03 Page 1 of 3 EXTERNAL PHOTOS TOP VIEW OF EUT BOTTOM VIEW OF EUT Report No.: AGC02129230401AP03 Page 2 of 3 FRONT VIEW OF EUT BACK VIEW OF EUT Report No.: AGC02129230401AP03 Page 3 of 3 LEFT VIEW OF EUT RIGHT VIEW OF EUT ****************************************End of Report*************************************

External Photos

Report No.: AGC02129230401AP03 Page 1 of 3 EXTERNAL PHOTOS TOP VIEW OF EUT BOTTOM VIEW OF EUT Report No.: AGC02129230401AP03 Page 2 of 3 FRONT VIEW OF EUT BACK VIEW OF EUT Report No.: AGC02129230401AP03 Page 3 of 3 LEFT VIEW OF EUT RIGHT VIEW OF EUT ****************************************End of Report*************************************

ID Label/Location Info

FCC ID and IC Label Location 15mm*20mm FCC ID: 2ASRV-232039FR IC: 26753-232039FR HVIN: CTF-T-ATE-232039FREBLK

Internal Photos

Report No.: AGC02129230401AP03 Page 1 of 4 INTERNAL PHOTOS OPEN VIEW OF EUT BATTERY VIEW OF EUT Report No.: AGC02129230401AP03 Page 2 of 4 INTERNAL VIEW OF EUT (FIGURE 1) INTERNAL VIEW OF EUT (FIGURE 2) Report No.: AGC02129230401AP03 Page 3 of 4 INTERNAL VIEW OF EUT (FIGURE 3) INTERNAL VIEW OF EUT (FIGURE 4) Report No.: AGC02129230401AP03 Page 4 of 4 INTERNAL VIEW OF EUT (FIGURE 5) ****************************************End of Report************************************* WPT Antenna 4cm

Internal Photos

Report No.: AGC02129230401AP03 Page 1 of 4 INTERNAL PHOTOS OPEN VIEW OF EUT BATTERY VIEW OF EUT Report No.: AGC02129230401AP03 Page 2 of 4 INTERNAL VIEW OF EUT (FIGURE 1) INTERNAL VIEW OF EUT (FIGURE 2) Report No.: AGC02129230401AP03 Page 3 of 4 INTERNAL VIEW OF EUT (FIGURE 3) INTERNAL VIEW OF EUT (FIGURE 4) Report No.: AGC02129230401AP03 Page 4 of 4 INTERNAL VIEW OF EUT (FIGURE 5) ****************************************End of Report************************************* WPT Antenna 4cm

RF Exposure Info

Page 1 of 15 RF Exposure Report Report No.: AGC02129230401FH01 FCC ID : 2ASRV-232039FR APPLICATION PURPOSE : Original Equipment PRODUCT DESIGNATION : POWERTHRU TM POWER BANK BRAND NAME : CASETiFY MODEL NAME : CTF-T-ATE-232039FREBLK APPLICANT : Casetagram Limited DATE OF ISSUE : Jul. 06, 2023 STANDARD(S) : KDB680106 D01 RF Exposure Wireless Charging Base App v03r01 REPORT VERSION : V 1.0 Attestation of Global Compliance (Shenzhen) Co., Ltd Report No.: AGC02129230401FH01 Page 2 of 15 REPORT REVISE RECORD Report Version Revise Time Issued Date Valid Version Notes V1.0 / Jul. 06, 2023 Valid Initial Release Report No.: AGC02129230401FH01 Page 3 of 15 TABLE OF CONTENTS 1. GENERAL INFORMATION .............................................................................................................................. 4 2. PRODUCT INFORMATION .............................................................................................................................. 5 2.1 PRODUCT TECHNICAL DESCRIPTION ................................................................................................ 5 2.2 TEST FREQUENCY LIST ........................................................................................................................ 5 3. TEST ENVIRONMENT ..................................................................................................................................... 6 3.1 ADDRESS OF THE TEST LABORATORY .............................................................................................. 6 3.2 TEST FACILITY ....................................................................................................................................... 6 3.3 ENVIRONMENTAL CONDITIONS........................................................................................................... 7 3.4 MEASUREMENT UNCERTAINTY .......................................................................................................... 7 3.5 LIST OF EQUIPMENTS USED ............................................................................................................... 7 4. EQUIPMENT USED IN TESTED SYSTEM ...................................................................................................... 8 5. DESCRIPTION OF TEST MODES ................................................................................................................... 8 6. RF EXPOSURE MEASUREMENT ................................................................................................................... 9 6.1 REFER EVALUATION METHOD ............................................................................................................. 9 6.2 TEST LIMITS ........................................................................................................................................... 9 6.3 MEASUREMENT SETUP ...................................................................................................................... 10 6.4 MEASUREMENT PROCEDURE ............................................................................................................ 11 6.5 MEASUREMENT RESULTS ................................................................................................................. 12 APPENDIX I: PHOTOGRAPHS OF TEST SETUP ............................................................................................ 14 Report No.: AGC02129230401FH01 Page 4 of 15 1. GENERAL INFORMATION Applicant Casetagram Limited Address 18/F, NEO, 123 Hoi Bun Road, Kwun Tong, Hong Kong Manufacturer Casetagram Limited Address 18/F, NEO, 123 Hoi Bun Road, Kwun Tong, Hong Kong Factory Huizhou SPEED Wireless Technology Co., Ltd. Address No.138 Huize Road, Hi-Tech Industrial Park of East River, Zhongkai Hi-tech District, Huizhou City, Guangdong Province, China Product Designation POWERTHRU TM POWER BANK Brand Name CASETiFY Test Model CTF-T-ATE-232039FREBLK Date of receipt of test item Apr. 03, 2023 Date of test Apr. 03, 2023 to Jul. 06, 2023 Deviation from Standard No any deviation from the test method Test Result Pass Prepared By Bibo Zhang (Project Engineer) Jul. 06, 2023 Reviewed By Calvin Liu (Reviewer) Jul. 06, 2023 Approved By Max Zhang (Authorized Officer) Jul. 06, 2023 Report No.: AGC02129230401FH01 Page 5 of 15 2. PRODUCT INFORMATION 2.1 PRODUCT TECHNICAL DESCRIPTION Equipment Specification WPT Operation Frequency 110.5kHz-148kHz Hardware Version V1.0 Software Version V01.04 Modulation Type ASK Number of channels 1 Channel Field Strength of Fundamental 78.16dBμV/m (Max) Antenna Designation Coil Antenna Antenna Gain 0dBi Power Supply DC 3.8V by battery EUT Input & Output Rating Type-C:DC 5V/3A, DC 9V/2A, DC 12V/1.5A Type-C:DC 5V/3A, DC 9V/2A, DC 12V/1.5A Wireless:5W/7.5W/10W Battery Capacity:5000mAh (19Wh) Adapter Information N/A 2.2 TEST FREQUENCY LIST Frequency Band Channel Number Test Frequency 110.5kHz-148kHz 01 114.8kHz Report No.: AGC02129230401FH01 Page 6 of 15 3. TEST ENVIRONMENT 3.1 ADDRESS OF THE TEST LABORATORY Laboratory: Attestation of Global Compliance (Shenzhen) Co., Ltd. Address: 1-2/F, Building 19, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China 3.2 TEST FACILITY The test facility is recognized, certified, or accredited by the following organizations: CNAS-Lab Code: L5488 Attestation of Global Compliance (Shenzhen) Co., Ltd. has been assessed and proved to be in compliance with CNAS-CL01 Accreditation Criteria for Testing and Calibration Laboratories (identical to ISO/IEC17025: 2017 General Requirements) for the Competence of Testing and Calibration Laboratories. A2LA-Lab Cert. No.: 5054.02 Attestation of Global Compliance (Shenzhen) Co., Ltd. EMC Laboratory has been accredited by A2LA for technical competence in the field of electrical testing, and proved to be in compliance with ISO/IEC 17025: 2017 General Requirements for the Competence of Testing and Calibration Laboratories and any additi…

Text truncated - open the document above for the full version.

RF Exposure Info

Page 1 of 15 RF Exposure Report Report No.: AGC02129230401FH01 FCC ID : 2ASRV-232039FR APPLICATION PURPOSE : Original Equipment PRODUCT DESIGNATION : POWERTHRU TM POWER BANK BRAND NAME : CASETiFY MODEL NAME : CTF-T-ATE-232039FREBLK APPLICANT : Casetagram Limited DATE OF ISSUE : Jul. 06, 2023 STANDARD(S) : KDB680106 D01 RF Exposure Wireless Charging Base App v03r01 REPORT VERSION : V 1.0 Attestation of Global Compliance (Shenzhen) Co., Ltd Report No.: AGC02129230401FH01 Page 2 of 15 REPORT REVISE RECORD Report Version Revise Time Issued Date Valid Version Notes V1.0 / Jul. 06, 2023 Valid Initial Release Report No.: AGC02129230401FH01 Page 3 of 15 TABLE OF CONTENTS 1. GENERAL INFORMATION .............................................................................................................................. 4 2. PRODUCT INFORMATION .............................................................................................................................. 5 2.1 PRODUCT TECHNICAL DESCRIPTION ................................................................................................ 5 2.2 TEST FREQUENCY LIST ........................................................................................................................ 5 3. TEST ENVIRONMENT ..................................................................................................................................... 6 3.1 ADDRESS OF THE TEST LABORATORY .............................................................................................. 6 3.2 TEST FACILITY ....................................................................................................................................... 6 3.3 ENVIRONMENTAL CONDITIONS........................................................................................................... 7 3.4 MEASUREMENT UNCERTAINTY .......................................................................................................... 7 3.5 LIST OF EQUIPMENTS USED ............................................................................................................... 7 4. EQUIPMENT USED IN TESTED SYSTEM ...................................................................................................... 8 5. DESCRIPTION OF TEST MODES ................................................................................................................... 8 6. RF EXPOSURE MEASUREMENT ................................................................................................................... 9 6.1 REFER EVALUATION METHOD ............................................................................................................. 9 6.2 TEST LIMITS ........................................................................................................................................... 9 6.3 MEASUREMENT SETUP ...................................................................................................................... 10 6.4 MEASUREMENT PROCEDURE ............................................................................................................ 11 6.5 MEASUREMENT RESULTS ................................................................................................................. 12 APPENDIX I: PHOTOGRAPHS OF TEST SETUP ............................................................................................ 14 Report No.: AGC02129230401FH01 Page 4 of 15 1. GENERAL INFORMATION Applicant Casetagram Limited Address 18/F, NEO, 123 Hoi Bun Road, Kwun Tong, Hong Kong Manufacturer Casetagram Limited Address 18/F, NEO, 123 Hoi Bun Road, Kwun Tong, Hong Kong Factory Huizhou SPEED Wireless Technology Co., Ltd. Address No.138 Huize Road, Hi-Tech Industrial Park of East River, Zhongkai Hi-tech District, Huizhou City, Guangdong Province, China Product Designation POWERTHRU TM POWER BANK Brand Name CASETiFY Test Model CTF-T-ATE-232039FREBLK Date of receipt of test item Apr. 03, 2023 Date of test Apr. 03, 2023 to Jul. 06, 2023 Deviation from Standard No any deviation from the test method Test Result Pass Prepared By Bibo Zhang (Project Engineer) Jul. 06, 2023 Reviewed By Calvin Liu (Reviewer) Jul. 06, 2023 Approved By Max Zhang (Authorized Officer) Jul. 06, 2023 Report No.: AGC02129230401FH01 Page 5 of 15 2. PRODUCT INFORMATION 2.1 PRODUCT TECHNICAL DESCRIPTION Equipment Specification WPT Operation Frequency 110.5kHz-148kHz Hardware Version V1.0 Software Version V01.04 Modulation Type ASK Number of channels 1 Channel Field Strength of Fundamental 78.16dBμV/m (Max) Antenna Designation Coil Antenna Antenna Gain 0dBi Power Supply DC 3.8V by battery EUT Input & Output Rating Type-C:DC 5V/3A, DC 9V/2A, DC 12V/1.5A Type-C:DC 5V/3A, DC 9V/2A, DC 12V/1.5A Wireless:5W/7.5W/10W Battery Capacity:5000mAh (19Wh) Adapter Information N/A 2.2 TEST FREQUENCY LIST Frequency Band Channel Number Test Frequency 110.5kHz-148kHz 01 114.8kHz Report No.: AGC02129230401FH01 Page 6 of 15 3. TEST ENVIRONMENT 3.1 ADDRESS OF THE TEST LABORATORY Laboratory: Attestation of Global Compliance (Shenzhen) Co., Ltd. Address: 1-2/F, Building 19, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China 3.2 TEST FACILITY The test facility is recognized, certified, or accredited by the following organizations: CNAS-Lab Code: L5488 Attestation of Global Compliance (Shenzhen) Co., Ltd. has been assessed and proved to be in compliance with CNAS-CL01 Accreditation Criteria for Testing and Calibration Laboratories (identical to ISO/IEC17025: 2017 General Requirements) for the Competence of Testing and Calibration Laboratories. A2LA-Lab Cert. No.: 5054.02 Attestation of Global Compliance (Shenzhen) Co., Ltd. EMC Laboratory has been accredited by A2LA for technical competence in the field of electrical testing, and proved to be in compliance with ISO/IEC 17025: 2017 General Requirements for the Competence of Testing and Calibration Laboratories and any additi…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 30 FCC Test Report Report No.: AGC02129230401FE10 FCC ID : 2ASRV-232039FR APPLICATION PURPOSE Original Equipment PRODUCT DESIGNATION : POWERTHRU TM POWER BANK BRAND NAME : CASETiFY MODEL NAME : CTF-T-ATE-232039FREBLK APPLICANT : Casetagram Limited DATE OF ISSUE : Apr. 24, 2023 STANDARD(S) : FCC Part 15 Subpart C REPORT VERSION : V 1.0 Attestation of Global Compliance (Shenzhen) Co., Ltd Report No.: AGC02129230401FE10 Page 2 of 30 REPORT REVISE RECORD Report Version Revise Time Issued Date Valid Version Notes V1.0 / Apr. 24, 2023 Valid Initial Release Report No.: AGC02129230401FE10 Page 3 of 30 TABLE OF CONTENTS 1. GENERAL INFORMATION .............................................................................................................................. 5 2. PRODUCT INFORMATION .............................................................................................................................. 6 2.1 PRODUCT TECHNICAL DESCRIPTION ................................................................................................ 6 2.2 TEST FREQUENCY LIST ........................................................................................................................ 6 2.3 RELATED SUBMITTAL(S) / GRANT (S) ................................................................................................. 7 2.4 TEST METHODOLOGY .......................................................................................................................... 7 2.5 SPECIAL ACCESSORIES ....................................................................................................................... 7 2.6 EQUIPMENT MODIFICATIONS .............................................................................................................. 7 2.7 ANTENNA REQUIREMENT .................................................................................................................... 7 3. TEST ENVIRONMENT ..................................................................................................................................... 8 3.1 ADDRESS OF THE TEST LABORATORY .............................................................................................. 8 3.2 TEST FACILITY ....................................................................................................................................... 8 3.3 ENVIRONMENTAL CONDITIONS........................................................................................................... 9 3.4 MEASUREMENT UNCERTAINTY .......................................................................................................... 9 3.5 LIST OF EQUIPMENTS USED ............................................................................................................. 10 4.SYSTEM TEST CONFIGURATION .................................................................................................................. 11 4.1 EUT CONFIGURATION .......................................................................................................................... 11 4.2 EUT EXERCISE ...................................................................................................................................... 11 4.3 CONFIGURATION OF TESTED SYSTEM ............................................................................................. 11 4.4 EQUIPMENT USED IN TESTED SYSTEM............................................................................................ 11 4.5 SUMMARY OF TEST RESULTS ........................................................................................................... 12 5. DESCRIPTION OF TEST MODES ................................................................................................................. 13 6. FIELD STRENGTH OF FUNDAMENTAL ...................................................................................................... 14 6.1 PROVISIONS APPLICABLE .................................................................................................................. 14 6.2 MEASUREMENT PROCEDURE ........................................................................................................... 15 6.3 FIELD STRENGTH CALCULATION ...................................................................................................... 16 6.4 MEASUREMENT SETUP (BLOCK DIAGRAM OF CONFIGURATION) ............................................... 17 6.5 MEASUREMENT RESULTS.................................................................................................................. 18 7. 20 dB BANDWIDTH ....................................................................................................................................... 24 7.1 PROVISIONS APPLICABLE .................................................................................................................. 24 7.2 MEASUREMENT PROCEDURE ........................................................................................................... 24 7.3 MEASUREMENT SETUP (BLOCK DIAGRAM OF CONFIGURATION) ............................................... 24 7.4 MEASUREMENT RESULTS.................................................................................................................. 25 8. AC POWER LINE CONDUCTED EMISSION TEST ...................................................................................... 26 8.1 LIMITS OF LINE CONDUCTED EMISSION TEST ............................................................................... 26 Report No.: AGC02129230401FE10 Page 4 of 30 8.2 MEASUREMENT SETUP (BLOCK DIAGRAM OF CONFIGURATION) ............................................... 26 8.3 PRELIMINARY PROCEDURE OF LINE CONDUCTED EMISSION TEST .......................................... 27 8.4 FINAL PROCEDURE OF LINE CONDUCTED EMISSION TEST ........................................................ 27 8.5 MEASUREMENT RESULTS ................................................................................…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 30 FCC Test Report Report No.: AGC02129230401FE10 FCC ID : 2ASRV-232039FR APPLICATION PURPOSE Original Equipment PRODUCT DESIGNATION : POWERTHRU TM POWER BANK BRAND NAME : CASETiFY MODEL NAME : CTF-T-ATE-232039FREBLK APPLICANT : Casetagram Limited DATE OF ISSUE : Apr. 24, 2023 STANDARD(S) : FCC Part 15 Subpart C REPORT VERSION : V 1.0 Attestation of Global Compliance (Shenzhen) Co., Ltd Report No.: AGC02129230401FE10 Page 2 of 30 REPORT REVISE RECORD Report Version Revise Time Issued Date Valid Version Notes V1.0 / Apr. 24, 2023 Valid Initial Release Report No.: AGC02129230401FE10 Page 3 of 30 TABLE OF CONTENTS 1. GENERAL INFORMATION .............................................................................................................................. 5 2. PRODUCT INFORMATION .............................................................................................................................. 6 2.1 PRODUCT TECHNICAL DESCRIPTION .…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Simon Chan(Product Development Director)
[email protected]+852-96412755Fax: 00852-34640488

Technical Contact

Casetagram Limited
[email protected]

China

Test Firm

Attestation of Global Compliance (Shenzhen) Co., LDoris Li
[email protected]+86-755-25234088

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.1105 MHz - 0.148 MHz-
Confidentiality
Long Term

Other Applications from Casetagram Limited

PowerThru TM 2-in-1 Charging Stand - FCC ID 2ASRV-232120FRE - Casetagram Limited
2ASRV-232120FRE

PowerThru TM 2-in-1 Charging Stand

Sep 19, 2023

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz