FCC Statement This device complies with part 15 of the FCC Rules. Operation is Subject To the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not explicitly approved by the party responsible for compliance could void the user's authority to operate this equipment. Note: this equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: · Reorient or relocate the receiving antenna. · Increase the separation between the equipment and receiver. · Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. · Consult the dealer or an experienced radio/TV technician for help. For Bluetooth: Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. For WPT: The equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. During the operation of device a distance of 15 cm surrounding the device and 20 cm above the top surface of the device must be respected.
Page 1 of 4 FCC ID: 2ASXG-FS018C Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity External Photos of the EUT Fig. 1 Fig. 2 Page 2 of 4 FCC ID: 2ASXG-FS018C Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 4 FCC ID: 2ASXG-FS018C Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 4 FCC ID: 2ASXG-FS018C Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7
Page 1 of 1 FCC ID: 2ASXG-FS018C Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity LABEL AND LOCATION (Size: L3.5cm x 3.0cm) Label Location Bedside Alarm Clock with Wireless Charging Model: WJ-018 FCC ID: 2ASXG-FS018C
Page1of3FCCID:2ASXG-FS018C ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity InternalPhotosoftheEUT Fig.1 Fig.2 Page2of3FCCID:2ASXG-FS018C ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 CoilAntenna Page3of3FCCID:2ASXG-FS018C ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6 BTAntenna
Page1of10FCCID:2ASXG-FS018C ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RFExposureEvaluationReport 1.ProductInformation FCCID:2ASXG-FS018C ProductNameBedsideAlarmClockwithWirelessCharging ModelNumberWJ-018 AdditionalModel79224PI,386042,FS018C,151467 ModelDeclarationPCBboard,structureandinternalofthesemodel(s)arethesame,So noadditionalmodelsweretested PowerSupplyInput:5V3.5A,17.5Wbyexternalpoweradaptor WirelessCharging:5W USBoutput:5V1A ModulationTypeASK FrequencyRange111.0~205.0KHz OperationFrequency125KHz AntennaTypeCoilAntenna Hardwareversion5.0 Softwareversion5.0 Accessories/ ExposurecategoryGeneralpopulation/uncontrolledenvironment EUTTypeProductionUnit DeviceTypeMobileDevice 2.EvaluationMethod PerKDB680106D01Section3.RFExposureRequirements; 1)ConsumerwirelesspowertransferdevicesapprovedunderPart18insomecaseshaveto demonstratecompliancewithRFexposurerequirements.Thepotentialforexposuremustbe assessedaccordingtotheoperatingconfigurationsofthewirelesssystemandtheexposure conditionsofusersandbystanders.RFexposuremustbeevaluatedwiththeclientdevice(s) beingchargedbytheprimaryatmaximumoutputpower.TheRFexposurerequirementsmust bedeterminedinconjunctionwiththedeviceoperatingcharacteristics,accordingtothemobile andportableexposurerequirementsinSection2.1091andSection2.1093oftherules.SAR andMPElimitsdonotcoverthefrequencyrangeforwirelesspowertransferapplicationswhich operatebelow100kHzand300kHzrespectively;therefore,RFexposurecomplianceneedsto bedeterminedwithrespectto1.1307(c)and(d)oftheFCCrules. 2)Basedonthedesignandimplementationofthepowertransferapplication,itmustbeclearly identifiedifmobileorportableRFexposureconditionsapply.Devicesthatareinstalledto provideseparationofatleast20cmfromusersandbystandersmayqualifyformobileexposure conditions.Forsomeconditionswhereusersandbystandersmaybeexposedatcloserthan20 cm,section2.1091(d)(4)oftherulesmayapply. 3)Fordevicesdesignedfortypicaldesktopapplications,suchawirelesschargingpads,RF exposureevaluationshouldbeconductedassumingauserseparationdistanceof15cm.Eand Page2of10FCCID:2ASXG-FS018C ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Hfieldstrengthmeasurementsornumericalmodelingmaybeusedtodemonstratecompliance. Measurementsshouldbemadefromallsidesandthetopoftheprimary/clientpair,withthe15 cmmeasuredfromthecenteroftheprobe(s)totheedgeofthedevice.Emissionsbetween100 kHzto300kHzshouldbeassessedversusthelimitsat300kHzinTable1ofSection1.1310: 614V/mand1.63A/m.AKDBinquiryisrequiredtodeterminetheapplicableexposurelimits below100kHz. 4)Portableexposureconditionsfrom100kHzto6GHzaredeterminedwithrespecttoSAR requirements.ExistingSARsystemsandtestproceduresaregenerallyintendedfor measurementsabove100MHz.Whilenumericalmodelingcanbeanalternative,the constraintsofsubstantialcomputationalresourcesatlowfrequenciescouldintroducefurther limitations.Underthesecircumstances,includingoperationsbelow100kHz,theCommission mayconsideracombinationofanalyticalanalysis,fieldstrength,radiatedandconductedpower measurements,inconjunctionwithsomelimitednumericalmodelingtoassesscompliance. 5)Dependingontheoperatingfrequency,existingSARandMPEmeasurementproceduresmay beadaptedtoevaluatewirelesspowertransferdevicesforcompliancewithrespecttomobileor portableexposureconditions.IfthegranteeoritstestlabhaveanyquestionsregardingRF exposureevaluationtheyshouldcontacttheFCCLaboratorywithsufficientsystemoperating configurationdetailstodetermineifRFexposureevaluationisnecessaryand,ifrequired,how toapplyspecifictestprocedures.Below100MHz,whenSARtestingisrequiredandthedevice isoperatingatcloseproximitytopersons,informationondevicedesign,implementation, operatingconfigurations,exposureconditionsofusersandbystandersareneededtodetermine theevaluationandtestingrequirements.Inaddition,theinfluenceofnearbyobjectsmayalso needconsiderationaccordingtothewirelesspowertransfersystemimplementation;for example,theeffectsofplacingthedevice,itscoilsorradiatingelementsonornearmetallic surfaces 3.EvaluationLimit 3.1Referevaluationmethod ANSIC95.1–1999:IEEEStandardforSafetyLevelswithRespecttoHumanExposuretoRadio FrequencyElectromagneticFields,3kHzto300GHz. FCCKDBpublication680106D01RFExposureWirelessChargingAppsv03:RFExposure ConsiderationsforLowPowerConsumerWirelessPowerTransferApplications FCCCFR47part11.1310:Radiofrequencyradiationexposurelimits. FCCCFR47part22.1091:Radiofrequencyradiationexposureevaluation:mobiledevices FCCCFR47part18.107:Indusial,Scientific,andMedicalEquipment Page3of10FCCID:2ASXG-FS018C ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 3.2Limit LimitsforMaximumPermissibleExposure(MPE)/ControlledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforOccupational/ControlledExposure 0.3-3.06141.63*1006 3.0-301842/f4.89/f*900/f 2 6 30-30061.40.1631.06 300-1,500//f/3006 1,500-100,000//56 LimitsforMaximumPermissibleExposure(MPE)/UncontrolledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforGeneralPopulation/UncontrolledExposure 0.3-1.346141.63*10030 1.34-30824/f2.19/f*180/f 2 30 30-30027.50.0730.230 300-1,500//f/150030 1,500-100,000//1.030 F=frequencyinMHz *=Plane-waveequivalentpowerdensity AccordingtoFCCKDB680106D01Section3.RFExposureRequirementsclause3the Emission-Limitsinthefrequencyrangefrom100KHzto300KHzsho…
Text truncated - open the document above for the full version.
Page 1 of 25 FCCID:2ASXG-FS018CReportNo.:LCSA051622140EC ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT For ShenzhenJinlishunTechnologyCo.,Ltd. BedsideAlarmClockwithWirelessCharging TestModel:WJ-018 AdditionalModelNo.:PleaseRefertoPage6 Preparedfor:ShenzhenJinlishunTechnologyCo.,Ltd. Address: 3/F,Building22,ChuangyeRoad,AiLianheIndustrialZone, LongchengStreet,LonggangDistrict,Shenzhen,China Preparedby:ShenzhenLCSComplianceTestingLaboratoryLtd. Address: 101,201BldgA&301BldgC,JujiIndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:(+86)755-82591330 Fax:(+86)755-82591332 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample:May23,2022 Numberoftestedsamples:2 Serialnumber:A051622140-1,A051622140-2 DateofTest:May23,2022~May27,2022 DateofReport:July04,2022 Page 2 of 25 FCCID:2ASXG-FS018CReportNo.:LCSA051622140EC ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT FCCCFR47PART15C ReportReferenceNo......................:LCSA051622140EC DateOfIssue......................................:July04,2022 TestingLaboratoryName..............:ShenzhenLCSComplianceTestingLaboratoryLtd. Address................................................: 101,201BldgA&301BldgC,JujiIndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China TestingLocation/Procedure............ : FullapplicationofHarmonisedstandards■PartialapplicationofHarmonisedstandards□ Otherstandardtestingmethod□ Applicant’sName.............................:ShenzhenJinlishunTechnologyCo.,Ltd. Address................................................: 3/F,Building22,ChuangyeRoad,AiLianheIndustrialZone, LongchengStreet,LonggangDistrict,Shenzhen,China TestSpecification Standard..............................................:FCCCFR47PART15C TestReportFormNo.........................:LCSEMC-1.0 TRFOriginator....................................:ShenzhenLCSComplianceTestingLaboratoryLtd. MasterTRF.........................................:Dated2011-03 ShenzhenLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenLCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceof thematerial.ShenzhenLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnot assumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialdueto itsplacementandcontext. TestItemDescription.....................:BedsideAlarmClockwithWirelessCharging TradeMark..........................................:i-box TestModel...........................................:WJ-018 PowerSupply......................................: Input:5V3.5A,17.5Wbyexternalpoweradaptor WirelessCharging:5W USBoutput:5V1A Result..................................................: Positive Compiledby:Supervisedby:Approvedby: JinWang/AdministratorCaryLuo/TechniqueprincipalGavinLiang/Manager Page 3 of 25 FCCID:2ASXG-FS018CReportNo.:LCSA051622140EC ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT TestResultPositive Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetest laboratory. TestReportNo.:LCSA051622140EC July04,2022 Dateofissue TestModel..............................:WJ-018 EUT.........................................:BedsideAlarmClockwithWirelessCharging Applicant...............................:ShenzhenJinlishunTechnologyCo.,Ltd. Address..................................: 3/F,Building22,ChuangyeRoad,AiLianheIndustrialZone, LongchengStreet,LonggangDistrict,Shenzhen,China Telephone...............................:/ Fax..........................................:/ Manufacturer........................:HongyeElectronicsFactory Address...................................: 5/Floor,Block3,JinyeScienceandTechnologyPark,Xiabian Village,LiaobuTown,DongguanCity,China Telephone...............................:/ Fax..........................................: / Factory...................................:HongyeElectronicsFactory Address...................................: 5/Floor,Block3,JinyeScienceandTechnologyPark,Xiabian Village,LiaobuTown,DongguanCity,China Telephone...............................:/ Fax..........................................:/ Page 4 of 25 FCCID:2ASXG-FS018CReportNo.:LCSA051622140EC ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RevisionHistory ReportVersionIssueDateRevisionContentRevisedBy 000July04,2022InitialIssue--- Page 5 of 25 FCCID:2ASXG-FS018CReportNo.:LCSA051622140EC ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TABLEOFCONTENTS 1.GENERALINFORMATION........................................................................................................6 1.1DescriptionofDevice(EUT)...............................................................................................................6 1.2SupportequipmentList...............................................................…
Text truncated - open the document above for the full version.
Page1of2FCCID:2ASXG-FS018C ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestSetupPhotosoftheEUT Fig.1 Fig.2 Page2of2FCCID:2ASXG-FS018C ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig. 3 Fig.4
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.111 MHz - 0.205 MHz | - |

Portable Bluetooth Speaker with Wireless Charging
Equipment Class
8CC - Part 18 Consumer Device
Alarm Clock Radio with wireless charging
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter