Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Jul 06, 2020
Application Purpose
Original Equipment
Date of Application
Jul 06, 2020
Equipment Note
Device Mounted On Keg for Ease of Searching
Frequency Range
2402.00000000 - 2480.00000000
Company
KegSpeed LLC
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

7/2/2020Bean Innovation & Marketing Ltd.1 7/2/2020Bean Innovation & Marketing Ltd.2 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help.

Cover Letter(s)

KegSpeed LLC 12500 Pluto Lane, Austin Texas 78727 I, an officer of KegSpeed LLC do hereby authorize Intertek Testing Services (Mr. Terry Chan / Tim Lee / Herbert Wong / Kenneth Wong) to act on our behalf in front of the Federal Communications Commission with respect to all matters relating to certification of equipment under Part 15 and Part 18 of the FCC Rules until further notice. I further certify that no party (as defined in 1.2002(b) of CFR 47, 2004) to this application, including myself, is subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Dated this 25th day June of 2019. By Printed: Timothy L Jones Title: President

Cover Letter(s)

KegSpeed LLC 12500 Pluto Lane, Austin Texas 78727 Attention: Application Examiner Re: Request for confidentiality Applicant: KegSpeed LLC FCC ID: 2AT3Z0100 To whom it may concern, Permanent Confidentiality Request is hereby submitted by KegSpeed LLC to withhold permanently from public review certain portions of the application for equipment certification for the referenced FCC identifiers. This request for confidentiality is made pursuant to 47 CFR 0.457(d) & 0.459 of the FCC Rules. In particular, the following sections of the application are to be kept permanently confidential: Schematics Detailed Block diagrams Detailed Operational/Functional Description Internal Photos Rationale for request for confidentiality: The KegTracker KS1 is a sealed device and is serviceable only by Grantee. In addition, KegSpeed LLC has invested considerable time and materials in research and development to produce the referenced product. Disclosure of the permanently confidential portions of this application to competitors would not only give them significant competitive advantages in developing similar products, but would also disclose successful implementation of unpublished, leading edge technology developed by us. The fee for confidentiality has been submitted along with the fee for certification. If you have questions or need further information, please contact the undersigned. Sincerely, Timothy L Jones President KegSpeed LLC

External Photos

INTERTEK TESTING SERVICE Report No.: HK19051624 Equipment Photographs (External)

ID Label/Location Info

23.3mm 28.2mm

Internal Photos

INTERTEK TESTING SERVICE Report No.: HK19051624 Equipment Photographs (Internal) INTERTEK TESTING SERVICE Report No.: HK19051624 Equipment Photographs (Internal) INTERTEK TESTING SERVICE Report No.: HK19051624 Equipment Photographs (Internal)

RF Exposure Info

Analysis Report The Equipment Under Test (EUT) is a KegSpeed Tracking Device which is operating in the 2.4GHz ISM band. Only three frequency channels are used as declared by the applicant (2402MHz, 2426MHz and 2480MHz). The EUT is powered by 3VDC (1 X CR2450 battery). 2.4GHz Bluetooth portion Antenna Type: Internal, Integral Antenna Gain: 0dBi Modulation Type: GFSK Frequency Range: 2402MHz, 2426MHz, 2480MHz, 3 channels EIRP range is -10dBm to 0dBm According to the KDB 447498: Conducted Power (max) = EIRP – Antenna gain = 0 dBm - 0 dBi = 0 dBm (1 mW) The SAR Exclusion Threshold Level: = 3.0 * (min. test separation distance, mm) / sqrt(freq. in GHz) = 3.0 * 5 / sqrt (2.480) mW = 9.53 mW Since the above conducted output power is well below the SAR Exclusion threshold level, so the EUT is considered to comply with SAR requirement without testing.

Test Report

2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Telephone: (852) 2173 8888 Facsimile: (852) 2785 5487 www.intertek.com Intertek’s standard Terms and Conditions can be obtained at our website http://www.intertek.com/terms/. The test report only allows to be revised within the retention period unless further standard or the requirement was noticed. This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. © 2017 Intertek Page 1 of 22 TEST REPORT Report No.: 19051624HKG-001 KegSpeed LLC Application For Certification (Original Grant) FCC ID: 2AT3Z0100 Transmitter Prepared and Checked by: Approved by: Signed On File Wong Cheuk Ho, Herbert Lead Engineer Wong Kwok Yeung, Kenneth Senior Lead Engineer Date: July 07, 2020 TEST REPORT KegSpeed LLC Intertek Report No: 19051624HKG-001 Page 2 of 22 GENERAL INFORMATION Grantee: KegSpeed LLC Grantee Address: 12500 Pluto Lane, Austin, TX 78727, USA Contact Person: Tim Jones Tel: 512-832-5847 Fax: 512-832-5847 Brand Name: KegTracker Model: KS01 Type of EUT: Transmitter Description of EUT: Device Mounted On Keg for Ease of Searching Serial Number: N/A FCC ID: 2AT3Z0100 Date of Sample Submitted: May 30, 2019 Date of Test: May 30, 2019 to July 07, 2020 Report No.: 19051624HKG-001 Report Date: July 07, 2020 Environmental Conditions: Temperature: +10 to 40°C Humidity: 10 to 90% Conclusion: Test was conducted by client submitted sample. The submitted sample as received complied with the 47 CFR Part 15 Certification. TEST REPORT KegSpeed LLC Intertek Report No: 19051624HKG-001 Page 3 of 22 SUMMARY OF TEST RESULT Test Specification Reference Results Transmitter Power Line Conducted Emissions 15.207 Pass Radiated Emission Radiated Emission on the Bandedge 15.249, 15.209 Pass Radiated Emission in Restricted Bands 15.205 Pass The equipment under test is found to be complying with the following standards: FCC Part 15, October 1, 2019 Edition Note: 1. The EUT uses a permanently attached antenna which, in accordance to section 15.203, is considered sufficient to comply with the pervisions of this section. 2. Pursuant to FCC part 15 Section 15.215(c), the 20 dB bandwidth of the emission was contained within the frequency band designated (mentioned as above) which the EUT operated. The effects, if any, from frequency sweeping, frequency hopping, other modulation techniques and frequency stability over excepted variations in temperature and supply voltage were considered. TEST REPORT KegSpeed LLC Intertek Report No: 19051624HKG-001 Page 4 of 22 TABLE OF CONTENTS 1.0 GENERAL DESCRIPTION ................................................................................................. 5 1.1 Product Description ..................................................................................................... 5 1.2 Related Submittal(s) Grants ......................................................................................... 5 1.3 Test Methodology ........................................................................................................ 5 1.4 Test Facility .................................................................................................................. 5 2.0 SYSTEM TEST CONFIGURATION ...................................................................................... 6 2.1 Justification .................................................................................................................. 6 2.2 EUT Exercising Software .............................................................................................. 6 2.3 Special Accessories ...................................................................................................... 6 2.4 Measurement Uncertainty .......................................................................................... 6 2.5 Support Equipment List and Description ...................................................................... 6 3.0 EMISSION RESULTS ....................................................................................................... 7 3.1 Field Strength Calculation ............................................................................................ 7 3.2 Radiated Emission Configuration Photograph ............................................................. 8 3.3 Radiated Emission Data ............................................................................................... 8 4.0 EQUIPMENT PHOTOGRAPHS ....................................................................................... 13 5.0 PRODUCT LABELLING .................................................................................................. 13 6.0 TECHNICAL SPECIFICATIONS ........................................................................................ 13 7.0 INSTRUCTION MANUAL ............................................................................................... 13 8.0 MISCELLANEOUS INFORMATION ................................................................................. 14 8.1 Radiated Emission on the Bandedge .......................................................................... 14 8.2 Discussion of Puls…

Text truncated - open the document above for the full version.

Test Setup Photos

INTERTEK TESTING SERVICE Report No: HK19051624 Configuration Photographs Worst-Case Radiated Emissions (Front View) INTERTEK TESTING SERVICE Report No: HK19051624 Configuration Photographs Worst-Case Radiated Emissions (Rear View)

Test Setup Photos

INTERTEK TESTING SERVICE Report No: HK19051624 Configuration Photographs Worst-Case Radiated Emissions (Front View) INTERTEK TESTING SERVICE Report No: HK19051624 Configuration Photographs Worst-Case Radiated Emissions (Rear View)

Contact Information

Applicant

Tim Jones
[email protected]512-832-5847Fax: 512-832-5847

Technical Contact

Intertek Testing Services Hong Kong Ltd.Kenneth Wong
[email protected](852) 2173 8888

2/F., Garment Centre, · Hong Kong

Non-Technical Contact

Intertek Testing Services Hong Kong Ltd.Kenneth Wong
[email protected](852) 2173 8888

Test Firm

Intertek Testing Services Hong Kong Ltd.Billy Chow
[email protected]85221738528Fax: 85227410521

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz-
Confidentiality
Long Term