FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Amkovery Tech. Development Co., Ltd/
  3. 2AT84-CDR7

2AT84-CDR7Digital Camera

Shenzhen Amkovery Tech. Development Co., Ltd

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Aug 06, 2026
Application Purpose
Original Equipment
Equipment Note
Digital Camera
Frequency Range
2412.00000000 - 2462.00000000
Company
Shenzhen Amkovery Tech. Development Co., Ltd
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

ShenzhenAmkoveryTech.DevelopmentCo.,Ltd 2.911(d)(7)USAAgentv1.5 Section2.911(d)(7)USAAgentforServiceofProcess Companyname:ShenzhenAmkoveryTech.DevelopmentCo.,Ltd Address:2F,BuildingC,AikeIndustrialPark,No.1,Lane1DabaoRoad,Baoan District,ShenzhenChina FCCID:2AT84-CDR7 2.911(d)(7)USADesignatedAgentforServiceofProcess We,[ShenzhenAmkoveryTech.DevelopmentCo.,Ltd]designate[LinkwldLLC] NOTE1 forthepurposeofacceptingserviceofprocessonbehalfoftheapplicant. Applicantconsent:Weacknowledgeourconsenttoacceptserviceofprocessinthe UnitedStatesformattersrelatedtotheapplicableequipment,andatthephysicalU.S. addressandemailaddressofthedesignatedagentandacknowledgeour acceptanceofourobligationtomaintainanagentforserviceofprocessintheUnited Statesfornolessthanoneyearaftereitherwethegranteehavepermanently terminatedallmarketingandimportationoftheapplicableequipmentwithintheU.S., orattheconclusionofanyCommission-relatedadministrativeorjudicialproceeding involvingtheequipment,whicheverislater. Agentobligation:Weacknowledgeourobligationtoacceptserviceofprocessinthe UnitedStatesformattersrelatedtotheapplicableequipmentatourphysicalU.S. addressandemailaddressfornolessthanoneyearaftereitherthegranteehas permanentlyterminatedallmarketingandimportationoftheapplicableequipment withintheU.S.,orattheconclusionofanyCommission-relatedadministrativeor judicialproceedinginvolvingtheequipment,whicheverislater. USAAgentApplicant Companyname:LinkwldLLCCompanyname:ShenzhenAmkovery Tech.DevelopmentCo.,Ltd USAAddress:7595TechnologyWaySte 100,Denver,CO80237,US Address:2F,BuildingC,AikeIndustrial Park,No.1,Lane1DabaoRoad,Baoan District,ShenzhenChina FRNNumber:0033625682GranteeFRNNumber:0028712081 ContactName:TimothyZhu FCCGranteeCode:2AT84 TelephoneNo:(747)717-2691ContactName:JinWuLi Email:[email protected] TelephoneNo:18926413822 Email:[email protected] Signature: Title:Manager Signature: Title:Manager Date:2026-07-29Date:2026-07-29 ShenzhenAmkoveryTech.DevelopmentCo.,Ltd 2.911(d)(7)USAAgentv1.5 NOTE1:AnapplicantlocatedintheUnitedStatesmaydesignateitselfastheagentforservice ofprocess. Reference;FederalRegisterdocument2022-28263publishedon02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-nation al-security-threats-to-the-communications-supply-chain-through-the

Attestation Statements

COMPANYLETTERHEAD CoveredEquipmentCertificationAttestationLetter DATE NemkoNorthAmerica,Inc. 303RiverRoad Ottawa K1V1H2 Canada ATTN.:ReviewingEngineer FCCID:2AT84-CDR7 ShenzhenAmkoveryTech.DevelopmentCo.,Ltd(“JinWuLi”)certifiesthatthe equipmentforwhichauthorizationissoughtisnot“covered”equipmentprohibitedfrom receivinganequipmentauthorizationpursuanttosection2.903oftheFCCrules. Note:Iftheequipmentforwhichtheapplicantseeksauthorizationisproducedby anyoftheentitiesidentifiedonthecurrentCoveredList,theapplicantshould includeanexplanationonwhytheequipmentisnot“covered”equipment. ShenzhenAmkoveryTech.DevelopmentCo.,Ltd(“JinWuLi”)certifiesthat,asofthe dateofthefilingoftheapplication,theapplicantisnotidentifiedontheCoveredListas anentityproducing“covered”equipment. ShenzhenAmkoveryTech.DevelopmentCo.,Ltd(“JinWuLi”)certifiesthatthe equipmentforwhichauthorizationissoughtdoesnotincludecybersecurityoranti-virus softwareproducedorprovidedbyKasperskyLab,Inc.oranyofitssuccessorsand assignees,includingequipmentwithintegratedKasperskyLab,Inc.(oranyofits successorsandassignees)cybersecurityoranti-virussoftwarepursuanttoDA-24-886 andKDB986446D01CoveredEquipmentGuidancesectionB(2a). Signed: Printedname:JinWuLi Title:Manager CompanyName:ShenzhenAmkoveryTech.DevelopmentCo.,Ltd Date:7/29/2026

Cover Letter(s)

ShenzhenAmkoveryTech.DevelopmentCo.,Ltd August4,2026 NemkoNorthAmerica,Inc. 303RiverRoad Ottawa,Ontario,Canada K1V1H2 REQUESTFORCONFIDENTIALITY-FCC FCCID:2AT84-CDR7 PursuanttoSections0.457(d)and0.459oftheCommission’sRulesandFCCGuidancedocument 726920,weherebyrequestpermanentconfidentialtreatmentofexhibitsidentifiedassuchinthe tablebelowandrequesttheyarepermanentlywithheldfrompublicreviewbasedonthedocuments containingtradesecretsandproprietaryinformationnotcustomarilyreleasedtothepublic.The publicdisclosureofthisinformationmightbeharmfultotheapplicantandprovideunjustifiedbenefits toitscompetitors. Wealsorequestshort-termconfidentialityoncertainexhibitsuntiltheintendeddateofmarketingas outlinedbelow.Werequesttheexhibitsbewithheldfrompublicviewforaperiodof180days.We attestmarketingoftheproductwillonlycommenceaftertheperiodofshort-termconfidentiality expires,orifmarketingistocommencebeforetherequestednumberofdayslistedabove,the granteewillinformNemkotoreleasetheShort-TermConfidentialityinformationwithheldontheFCC equipmentauthorizationwebsite. ExhibitTypeofConfidentialityRequested BlockDiagrams☒Permanent ☐ShortTerm ExternalPhotos------------------☒ShortTerm InternalPhotos ☐ Permanent* ☒ShortTerm OperationDescription☒Permanent ☐ShortTerm PartsList&Placement/BOM ☐Permanent☐ShortTerm Tune-UpProcedure ☐Permanent☐ShortTerm SchematicDiagrams☒Permanent ☐ShortTerm TestSetupPhotos------------------☒ShortTerm User’sManual ☐Permanent* ☒ShortTerm Theasteriskeditems(*)requirefurtherinformationtobeprovidedinthisjustificationletterbeforepermanentconfidentiality willbeextendedtotheseexhibits.PleaserefertoFCCKDB726920D01foundat: https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=41731andreviewsectionII,3)regarding specificinformationthatmustaccompanytheserequests. Note:anydocumentsheldundertheShort-Termconfidentialitywillautomaticallybecomepublic aftertherequestedtimeifanappropriateextensionrequesthasnotbeenreceived.Anyexhibits (i.e.,schematicdiagrams)thatmayhavealreadybeenrequestedtohave“Permanent” confidentialityasshownaboveneednotberepeatedunderShort-Termconfidentialityrequest. Sincerely, Signed: Printedname:JinWuLi Title:Manager CompanyName:ShenzhenAmkoveryTech.DevelopmentCo.,Ltd

Cover Letter(s)

FamilyCertificationAttestationLetter 2026/7/29 NemkoCanadaInc 303RiverRoad Ottawa K1V1H2 Canada CompanyName:ShenzhenAmkoveryTech.DevelopmentCo.,Ltd FCCID: 2AT84-CDR7 Models:CDR7,CDR7H,CD-R7,CD-R7H,CDR7S,CD-R7S,CDR7P,CD-R7P WeherebyrequestFamilyCertificationfortheabovementionedModelsbasedonthem beingelectricallyidentical. Abovemodelsareidenticalinschematicandstructure,onlythecolourisdifferent forallthemodels,thereforethetestperformedonthemodel__CDR7__. Signed: Printedname:JinWuLi Title:Manager Date:2026/7/29

ID Label/Location Info

LabelLocation Confirmtheuseofrealappearancephotosasreferences

RF Exposure Info

RFEXPOSUREEVALUATION FCCID:2AT84-CDR7 AccordingtoKDB447498D01MobileandPortableDevicesRFExposureProcedures andEquipmentAuthorizationPoliciesv06. AccordingtoFCC1.1310:Thecriterialistedinthefollowingtableshallbeusedto evaluatetheenvironmentimpactofhumanexposuretoradiofrequency(RF)Radiationas specifiedin§1.1307(b): RoutineSARevaluationreferstothatspecificallyrequiredby§2.1093,using measurementsorcomputersimulation.WhenroutineSARevaluationisnotrequired, portabletransmitterswithoutputpowergreaterthantheapplicablelowthresholdrequire SARevaluationtoqualifyforTCBapproval. Channel (MHz) Maximum output power (dBm) Tuneup tolerance (dBm) MaxTuneUp Power(dBm) Distance (mm) Calculation results Limit Operating Mode 24127.587.58±18.58052.2353 DSSS24377.757.75 ±1 8.75052.3433 24628.178.17±19.17052.6023 24127.507.50±18.50052.1943 OFDM24377.747.74 ±1 8.74052.3383 24628.258.25±19.25052.6503 24127.337.33±18.33052.1103 OFDM24377.797.79 ±1 8.79052.3653 24628.178.17±19.17052.6023 Result:NoStandaloneSARtestisrequired.

Test Report

ReportNo.:1812C60290712501-01 Page 21 of 49 11B-Ant1-2462-PASS 11G-Ant1-2412-PASS ReportNo.:1812C60290712501-01 Page 22 of 49 11G-Ant1-2437-PASS 11G-Ant1-2462-PASS ReportNo.:1812C60290712501-01 Page 23 of 49 11N20SISO-Ant1-2412-PASS 11N20SISO-Ant1-2437-PASS ReportNo.:1812C60290712501-01 Page 24 of 49 11N20SISO-Ant1-2462-PASS ReportNo.:1812C60290712501-01 Page 25 of 49 AppendixE:ConductedBandedge TestResult TestModeAntenna Ch. Name Frequency[MHz] Ref. Level[dBm] Result[dBm]Limit[dBm]Verdict 11BAnt1Low2412-0.78-47.88≤-30.78PASS 11BAnt1High2462-0.11-51.04≤-30.11PASS 11GAnt1Low2412-3.87-36.77≤-33.87PASS 11GAnt1High2462-3.20-50.64≤-33.2PASS 11N20SISOAnt1Low2412-4.34-39.76≤-34.34PASS 11N20SISOAnt1High2462-3.70-50.75≤-33.7PASS ReportNo.:1812C60290712501-01 Page 26 of 49 TestGraphs 11B-Ant1-2412-PASS 11B-Ant1-2462-PASS ReportNo.:1812C60290712501-01 Page 27 of 49 11G-Ant1-2412-PASS 11G-Ant1-2462-PASS ReportNo.:1812C60290712501-01 Page 28 of 49 11N20SISO-Ant1-2412-PASS 11N20SISO-Ant1-2462-PASS ReportNo.:1812C60290712501-01 Page 29 of 49 AppendixF:ConductedSpuriousEmission TestResult TestModeAntennaFrequency[MHz] Freq.Range [Mhz] Ref. Level [dBm] Result [dBm] Limit [dBm] Verdict 11BAnt124120~Reference-1.05-1.05---PASS 11BAnt1241230~1000-1.05-53≤-31.05PASS 11BAnt124121000~26500-1.05-37.67≤-31.05PASS 11BAnt124370~Reference-0.42-0.42---PASS 11BAnt1243730~1000-0.42-51.84≤-30.42PASS 11BAnt124371000~26500-0.42-36.49≤-30.42PASS 11BAnt124620~Reference-0.45-0.45---PASS 11BAnt1246230~1000-0.45-52.11≤-30.45PASS 11BAnt124621000~26500-0.45-37.2≤-30.45PASS 11GAnt124120~Reference-4.19-4.19---PASS 11GAnt1241230~1000-4.19-51.44≤-34.19PASS 11GAnt124121000~26500-4.19-37.41≤-34.19PASS 11GAnt124370~Reference-3.60-3.60---PASS 11GAnt1243730~1000-3.60-52.88≤-33.6PASS 11GAnt124371000~26500-3.60-37.02≤-33.6PASS 11GAnt124620~Reference-3.62-3.62---PASS 11GAnt1246230~1000-3.62-51.89≤-33.62PASS 11GAnt124621000~26500-3.62-37.4≤-33.62PASS 11N20SISOAnt124120~Reference-3.43-3.43---PASS 11N20SISOAnt1241230~1000-3.43-52.53≤-33.43PASS 11N20SISOAnt124121000~26500-3.43-37.3≤-33.43PASS 11N20SISOAnt124370~Reference-4.03-4.03---PASS 11N20SISOAnt1243730~1000-4.03-52.77≤-34.03PASS 11N20SISOAnt124371000~26500-4.03-37.32≤-34.03PASS 11N20SISOAnt124620~Reference-3.16-3.16---PASS 11N20SISOAnt1246230~1000-3.16-52.17≤-33.16PASS 11N20SISOAnt124621000~26500-3.16-37.74≤-33.16PASS Remark:Regardingthespuriousemissionsfrom30MHzto26.5GHz,thecablelosshavebeensetinthe 'InputCorrection'oftheSpectrumAnalyzerduringthetest. ReportNo.:1812C60290712501-01 Page 30 of 49 TestGraphs 11B-Ant1-2412-0~Reference-PASS 11B-Ant1-2412-30~1000-PASS ReportNo.:1812C60290712501-01 Page 31 of 49 11B-Ant1-2412-1000~26500-PASS 11B-Ant1-2437-0~Reference-PASS ReportNo.:1812C60290712501-01 Page 32 of 49 11B-Ant1-2437-30~1000-PASS 11B-Ant1-2437-1000~26500-PASS ReportNo.:1812C60290712501-01 Page 33 of 49 11B-Ant1-2462-0~Reference-PASS 11B-Ant1-2462-30~1000-PASS ReportNo.:1812C60290712501-01 Page 34 of 49 11B-Ant1-2462-1000~26500-PASS 11G-Ant1-2412-0~Reference-PASS ReportNo.:1812C60290712501-01 Page 35 of 49 11G-Ant1-2412-30~1000-PASS 11G-Ant1-2412-1000~26500-PASS ReportNo.:1812C60290712501-01 Page 36 of 49 11G-Ant1-2437-0~Reference-PASS 11G-Ant1-2437-30~1000-PASS ReportNo.:1812C60290712501-01 Page 37 of 49 11G-Ant1-2437-1000~26500-PASS 11G-Ant1-2462-0~Reference-PASS ReportNo.:1812C60290712501-01 Page 38 of 49 11G-Ant1-2462-30~1000-PASS 11G-Ant1-2462-1000~26500-PASS ReportNo.:1812C60290712501-01 Page 39 of 49 11N20SISO-Ant1-2412-0~Reference-PASS 11N20SISO-Ant1-2412-30~1000-PASS ReportNo.:1812C60290712501-01 Page 40 of 49 11N20SISO-Ant1-2412-1000~26500-PASS 11N20SISO-Ant1-2437-0~Reference-PASS

Test Report

ReportNo.:1812C60290712501-01 Page 41 of 49 11N20SISO-Ant1-2437-30~1000-PASS 11N20SISO-Ant1-2437-1000~26500-PASS ReportNo.:1812C60290712501-01 Page 42 of 49 11N20SISO-Ant1-2462-0~Reference-PASS 11N20SISO-Ant1-2462-30~1000-PASS ReportNo.:1812C60290712501-01 Page 43 of 49 11N20SISO-Ant1-2462-1000~26500-PASS ReportNo.:1812C60290712501-01 Page 44 of 49 AppendixG:DutyCycle TestResult TestModeAntennaFrequency[MHz] Transmission Duration [ms] Transmission Period[ms] DutyCycle [%] Factor 11BAnt1241212.4212.6098.570.06 11BAnt1243712.4212.6098.570.06 11BAnt1246212.4212.6098.570.06 11GAnt124122.062.1994.060.27 11GAnt124372.062.1994.060.27 11GAnt124622.062.1994.060.27 11N20SISOAnt124121.922.0693.200.31 11N20SISOAnt124371.922.0693.200.31 11N20SISOAnt124621.922.0693.200.31 ReportNo.:1812C60290712501-01 Page 45 of 49 TestGraphs NTNV-11B-Ant1-2412 NTNV-11B-Ant1-2437 ReportNo.:1812C60290712501-01 Page 46 of 49 NTNV-11B-Ant1-2462 NTNV-11G-Ant1-2412 ReportNo.:1812C60290712501-01 Page 47 of 49 NTNV-11G-Ant1-2437 NTNV-11G-Ant1-2462 ReportNo.:1812C60290712501-01 Page 48 of 49 NTNV-11N20SISO-Ant1-2412 NTNV-11N20SISO-Ant1-2437 ReportNo.:1812C60290712501-01 Page 49 of 49 NTNV-11N20SISO-Ant1-2462 ---End---

Test Report

Dongguan Lixinwei Electronics Co., Ltd Antenna Specification for Approval Customer Name: Address: Product Name: 2.4G PCB antenna Part NO.: C113H-IPEXLXW01-70 Write By: Zhou Min Issued Date: 2025-4-8 Customer: R&D DeptBusiness DeptApproved By Supplier R&D Dept Engineer Dept Approval Ni Sheng Zhang Ming xiong Room 202, 2nd Floor, Area D, Fuhui Chuangyuan, Dongjiang Road, Helu Village, Huangjiang Town, Dongguan, Guangdong, China Antenna size Product Specification A. Electrical Characteristics Frequency: 2400MHz ~2500MHz VSWR: <2.0 Efficiency: >46% Impedance: 50 Ohm Polarization Line Monopole Gain:1.09DBi B. Material & Mechanical Characteristics Material of Radiator Cu Cable Type:1.13MM Connector Type : IPEX1 Dimension C. Environmental Operation Temperature - 30 °C ~ + 80 °C Storage Temperature - 30 °C ~ + 85 °C Test Equipment & Conditions 1. Network Analyzers : Agilent 8753D 5071B 2. Communications Test Set: Agilent E5515C 3. 3D Chamber Test System Efficiency: S11 Radiation Pattern:

Test Report

Page 1 of 35 FCC Test Report Report No.:1812C60290712501 Applicant: Shenzhen Amkovery Tech. Development Co., Ltd Address: 2F, Building C, Aike Industrial Park, No.1, Lane 1 Dabao Road, Baoan District, Shenzhen China Product Name:Digital Camera Report Date:2026-07-29 Shenzhen Anbotek Compliance Laboratory Limited #检测章# #资质章# #报告二维码# Report No.:1812C60290712501Page 2 of 35 FCC ID: 2AT84-CDR7 Contents 1. General Information ...............................................................................................................................6 1.1. Client Information ........................................................................................................................6 1.2. Description of Device (EUT) ........................................................................................................6 1.3. Auxiliary Equipment Used During Test........................................................................................7 1.4. Operation channel list..................................................................................................................8 1.5. Description of Test Mode(s) ........................................................................................................8 1.6. Measurement Uncertainty ...........................................................................................................8 1.7. Additional Instructions .................................................................................................................9 1.8. Test Summary .............................................................................................................................9 1.9. Description of Test Facility ........................................................................................................10 1.10. Disclaimer................................................................................................................................10 1.11. Test Equipment List.................................................................................................................11 2. Antenna requirement ...........................................................................................................................13 2.1. Conclusion.................................................................................................................................13 3. Conducted Emission at AC power line ................................................................................................14 3.1. EUT Operation ..........................................................................................................................14 3.2. Test Setup .................................................................................................................................14 3.3. Test Data ...................................................................................................................................15 4. 6dB Bandwidth ....................................................................................................................................17 4.1. EUT Operation ..........................................................................................................................17 4.2. Test Setup .................................................................................................................................17 4.3. Test Data ...................................................................................................................................17 5. Maximum Conducted Output Power....................................................................................................18 5.1. EUT Operation ..........................................................................................................................18 5.2. Test Setup .................................................................................................................................18 5.3. Test Data ...................................................................................................................................18 6. Power Spectral Density .......................................................................................................................19 6.1. EUT Operation ..........................................................................................................................19 6.2. Test Setup .................................................................................................................................19 6.3. Test Data ...................................................................................................................................19 7. Emissions in non-restricted frequency bands ......................................................................................20 7.1. EUT Operation ..........................................................................................................................20 7.2. Test Setup .................................................................................................................................20 7.3. Test Data ...................................................................................................................................20 8. Band edge emissions (Radiated) ........................................................................................................21 8.1. EUT Operation ..........................................................................................................................21 8.2. Test Setup .................................................................................................................................22 8.3. Test Data ...................................................................................................................................23 9. Emissions in restricted frequency bands (below 1GHz) ...........................................…

Text truncated - open the document above for the full version.

Test Report

ReportNo.:1812C60290712501-01 Page 1 of 49 AppendixTestData ReportNo.:1812C60290712501-01TestSampleNo.:1-2-2 StartTestDate:2026-7-2FinishTestDate:2026-7-29 TestEngineer:Auditor: Temperature:22.3°CRelativeHumidity:62% Pressure:100.4kPa AppendixA:6dBBandwidth TestResult TestModeAntennaFrequency[MHz] 6dBBW [MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict 11BAnt124129.2802407.4002416.6800.5PASS 11BAnt124379.2802432.4002441.6800.5PASS 11BAnt124629.2802457.4002466.6800.5PASS 11GAnt1241216.4002403.8802420.2800.5PASS 11GAnt1243716.3202428.8802445.2000.5PASS 11GAnt1246216.4402453.8402470.2800.5PASS 11N20SISOAnt1241217.5202403.3202420.8400.5PASS 11N20SISOAnt1243717.6402428.2402445.8800.5PASS 11N20SISOAnt1246217.5602453.2402470.8000.5PASS ReportNo.:1812C60290712501-01 Page 2 of 49 TestGraphs 11B-Ant1-2412-PASS 11B-Ant1-2437-PASS ReportNo.:1812C60290712501-01 Page 3 of 49 11B-Ant1-2462-PASS 11G-Ant1-2412-PASS ReportNo.:1812C60290712501-01 Page 4 of 49 11G-Ant1-2437-PASS 11G-Ant1-2462-PASS ReportNo.:1812C60290712501-01 Page 5 of 49 11N20SISO-Ant1-2412-PASS 11N20SISO-Ant1-2437-PASS ReportNo.:1812C60290712501-01 Page 6 of 49 11N20SISO-Ant1-2462-PASS ReportNo.:1812C60290712501-01 Page 7 of 49 AppendixB:99%OccupiedBandwidth TestResult TestModeAntenna Channel Frequency[MHz] OCB [MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict 11BAnt1241214.1932404.95852419.1515------ 11BAnt1243714.1892429.96162444.1506------ 11BAnt1246214.1802454.96332469.1433------ 11GAnt1241217.1602403.44272420.6027------ 11GAnt1243717.1522428.48452445.6365------ 11GAnt1246217.2142453.46292470.6769------ 11N20SISOAnt1241218.2422402.93992421.1819------ 11N20SISOAnt1243718.2262427.96272446.1887------ 11N20SISOAnt1246218.1622453.03452471.1965------ ReportNo.:1812C60290712501-01 Page 8 of 49 TestGraphs 11B-Ant1-2412 11B-Ant1-2437 ReportNo.:1812C60290712501-01 Page 9 of 49 11B-Ant1-2462 11G-Ant1-2412 ReportNo.:1812C60290712501-01 Page 10 of 49 11G-Ant1-2437 11G-Ant1-2462 ReportNo.:1812C60290712501-01 Page 11 of 49 11N20SISO-Ant1-2412 11N20SISO-Ant1-2437 ReportNo.:1812C60290712501-01 Page 12 of 49 11N20SISO-Ant1-2462 ReportNo.:1812C60290712501-01 Page 13 of 49 AppendixC:Maximumconductedoutputpower TestResultAverage Test Mode Antenna Frequenc y[MHz] Average power [dBm] Duty Cycle [%] DC Factor [dB] Result [dBm] Limit [dBm] Verdict 11BAnt124127.5298.570.067.58 ≤30.0 0 PASS 11BAnt124377.6998.570.067.75 ≤30.0 0 PASS 11BAnt124628.1198.570.068.17 ≤30.0 0 PASS 11GAnt124127.2394.060.277.50 ≤30.0 0 PASS 11GAnt124377.4794.060.277.74 ≤30.0 0 PASS 11GAnt124627.9894.060.278.25 ≤30.0 0 PASS 11N20SI SO Ant124127.0293.200.317.33 ≤30.0 0 PASS 11N20SI SO Ant124377.4893.200.317.79 ≤30.0 0 PASS 11N20SI SO Ant124627.8693.200.318.17 ≤30.0 0 PASS Note:TheDutyCycleFactor(10*log(1/D))andcablelossarecompensatedinthegraph. ReportNo.:1812C60290712501-01 Page 14 of 49 TestGraphsAverage 11B-Ant1-2412-PASS 11B-Ant1-2437-PASS ReportNo.:1812C60290712501-01 Page 15 of 49 11B-Ant1-2462-PASS 11G-Ant1-2412-PASS ReportNo.:1812C60290712501-01 Page 16 of 49 11G-Ant1-2437-PASS 11G-Ant1-2462-PASS ReportNo.:1812C60290712501-01 Page 17 of 49 11N20SISO-Ant1-2412-PASS 11N20SISO-Ant1-2437-PASS ReportNo.:1812C60290712501-01 Page 18 of 49 11N20SISO-Ant1-2462-PASS ReportNo.:1812C60290712501-01 Page 19 of 49 AppendixD:Maximumpowerspectraldensity TestResult Test Mode Antenna Frequency [MHz] Result[dBm/30kHz]Limit[dBm/3kHz]Verdict 11BAnt12412-14.17≤8.00PASS 11BAnt12437-14.03≤8.00PASS 11BAnt12462-13.44≤8.00PASS 11GAnt12412-16.29≤8.00PASS 11GAnt12437-16.17≤8.00PASS 11GAnt12462-15.88≤8.00PASS 11N20SIS O Ant12412-16.31≤8.00PASS 11N20SIS O Ant12437-16.56≤8.00PASS 11N20SIS O Ant12462-15.73≤8.00PASS Note: 1.TheDutyCycleFactor(10*log(1/D))andcablelossarecompensatedinthegraph. ReportNo.:1812C60290712501-01 Page 20 of 49 TestGraphs 11B-Ant1-2412-PASS 11B-Ant1-2437-PASS

Contact Information

Applicant

JinWu Li
[email protected]Fax: 0755-83762022

Technical Contact

Linkwld LLCTimothy Zhu
[email protected]

7595 Technology Way Ste 100 · Denver, 80237 · United States

Test Firm

Shenzhen Anbotek Compliance Laboratory LimitedJeff Zhu
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz6.70 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted.