Date: 20.07.2020 Page 1 of 34 User Manual Indy 2k UHF Reader For Muehlbauer RFID production machines Version 1.8 Indy 2k UHF Reader Indy 2k UHF reader electronic Date: 20.07.2020 Page 2 of 34 Index Safety instructions ................................................................................................................................... 4 1 System Overview .............................................................................................................................. 5 1.1 How is the reader hardware used ....................................................................................................... 5 2 Reader Firmware ............................................................................................................................. 6 2.1.1 MAC Register .................................................................................................................................................. 6 2.1.2 OEM Register................................................................................................................................................... 6 2.2 Software Tools ...................................................................................................................................... 7 2.2.1 Indy Tool (Development Tool) ........................................................................................................................ 7 2.2.2 MB-Reader-Tool for INDY 2k and Skyetek UHF Reader ............................................................................... 7 3 Hardware interfaces ........................................................................................................................ 7 3.1 Serial HOST Interface ......................................................................................................................... 7 3.2 Mini-USB interface .............................................................................................................................. 8 3.3 Reset input ............................................................................................................................................ 8 3.4 GPIO 24V Interface ............................................................................................................................. 8 3.5 GPIO TTL Interface ............................................................................................................................ 9 3.6 Power supply at Interface Bord .......................................................................................................... 9 3.7 Antenna Connections ........................................................................................................................... 9 4 Command dialog between Host <==> Reader .............................................................................. 10 4.1 Serial Re-Syncronisation with Indy 2k Reader ............................................................................... 10 4.2 Reader commands for INDY R2k Readers ..................................................................................... 11 4.3 MAC Register Config Blocks for INDY R2k Readers .................................................................... 11 4.4 Register Struktur MAC Firmware .................................................................................................. 12 4.4.1 General Block (address range 0x00) .............................................................................................................. 12 4.4.2 Test Block (address range 0x01) .................................................................................................................... 12 4.4.3 Platform Control Block (address range 0x02) ................................................................................................ 12 4.4.4 Protocol Scheduler Block (address range 0x03)............................................................................................. 12 4.4.5 MAC Bypass Block (address range 0x04) ..................................................................................................... 12 4.4.6 OEM Config Block (address range 0x05) ...................................................................................................... 12 4.4.7 GPIO Block (address range 0x06) .................................................................................................................. 12 4.4.8 Antenna Block (address range 0x07) ............................................................................................................. 13 4.4.9 Tag Select Block (address range 0x08) .......................................................................................................... 13 4.4.10 Inventory Block (address range 0x09) ....................................................................................................... 13 4.4.11 Tag Access Block (address range 0x0A) ................................................................................................... 13 4.4.12 RFTC Block (address range 0x0B) ........................................................................................................... 13 4.4.13 Frequency Block (address range 0x0C) ..................................................................................................... 14 4.4.14 Reserved Customer Block (address range 0x0F) ....................................................................................... 14 4.4.15 Host Command Block (address range 0xF0) ............................................................................................. 14 5 Configuration of INDY R2k Reader ............................................................................................. 15 5.1 Maschine Setup for Indy 2k Readers ............................................................................................... 15 5.2 Command-Dialog between Maschine <==> Indy Re…
Text truncated - open the document above for the full version.
Long/Short-term Confidentiality Request PHOENIX TESTLAB GmbH Date: 09 September 2019 Product Certification Königswinkel 10 D 32825 Blomberg FCC ID: 2AT8S61065822 To Whom It May Concerns, Pursuant to sections 0.457(d) and 0.459 of CFR 47 and to avoid premature release of sensitive information prior to marketing or release of the product to the public, we hereby request long-term confidential treatment of information accompanying this application as outlined below: ☒ Schematics ☒ Parts List ☒ Block Diagram ☐ Tune-Up Info ☒ Operational Description In addition we hereby request the following exhibits contained in this application to be temporarily (short-term confidentiality) withheld from the public disclosure ☐ for an initial period of days ☐ until: ☒ not applicable ☐ External Photos ☐ Test Setup Photos ☐ Internal Photos ☐ Users Manual The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to rule 0.457(d), disclosure of this application and all accompanying documentation will not be made before the date of the GRANT for this application. If you have any questions, please feel free to contact me. Yours sincerely, Tobias Zollner Head of Product Compliance Management
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Mühlbauer GmbH & Co. KG UHF Reader Indy 2k UHF Reader 170713-AU02+W01 Annex B Page 1 of 4 1 Annex B – External pictures of EUT 1.1 List of Pictures Picture 1: Top view of test sample ..................................................................................... 2 Picture 2: Bottom view of test sample ................................................................................ 2 Picture 3: Top view of EUT with antennas ......................................................................... 3 Picture 4: Top view of antenna .......................................................................................... 3 Picture 5: Top view of tag .................................................................................................. 4 Picture 6: Top view of antenna cable ................................................................................. 4 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Mühlbauer GmbH & Co. KG UHF Reader Indy 2k UHF Reader 170713-AU02+W01 Annex B Page 2 of 4 Picture 1: Top view of test sample Picture 2: Bottom view of test sample EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Mühlbauer GmbH & Co. KG UHF Reader Indy 2k UHF Reader 170713-AU02+W01 Annex B Page 3 of 4 Picture 3: Top view of EUT with antennas Picture 4: Top view of antenna EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Mühlbauer GmbH & Co. KG UHF Reader Indy 2k UHF Reader 170713-AU02+W01 Annex B Page 4 of 4 Picture 5: Top view of tag Picture 6: Top view of antenna cable
Indy 2k UHF Reader System Muehlbauer GmbH & Co. KG Germany FCC ID: 2AT8S61065822 part no. 61065822 Certified 902 – 928MHz This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may undesired operation. FCC Product ID Label Label size: 6,5 x 3,2mm (Mounting as sticky label at side wall of reader case) Font size for FCC text message: 6 Font size FCC ID data: 8 Indy 2k UHF Reader System Muehlbauer GmbH & Co. KG Germany FCC ID: 2AT8S61065822 part no. 61065822 Certified 902 – 928MHz This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may undesired operation.
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Mühlbauer GmbH & Co. KG UHF Reader Indy 2k UHF Reader 170713-AU02+W01 Annex C Page 1 of 6 1 Annex C – Internal pictures of EUT 1.1 List of Pictures Picture 1: Top view of opened EUT ................................................................................... 2 Picture 2: RF module with antenna connectors in housing – top view ............................... 2 Picture 3: RF module with antenna connectors in housing without ribbon cable – top view ................................................................................................................................... 3 Picture 4: Detailed view of ribbon cable ............................................................................. 3 Picture 5: Antenna connectors – front view ....................................................................... 4 Picture 6: RF module with power supply – top view .......................................................... 4 Picture 7: RF module with power supply – back view ........................................................ 5 Picture 8: RF module with antenna connectors – top view ................................................ 5 Picture 9: RF module with antenna connectors – back view ............................................. 6 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Mühlbauer GmbH & Co. KG UHF Reader Indy 2k UHF Reader 170713-AU02+W01 Annex C Page 2 of 6 Picture 1: Top view of opened EUT Picture 2: RF module with antenna connectors in housing – top view EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Mühlbauer GmbH & Co. KG UHF Reader Indy 2k UHF Reader 170713-AU02+W01 Annex C Page 3 of 6 Picture 3: RF module with antenna connectors in housing without ribbon cable – top view Picture 4: Detailed view of ribbon cable EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Mühlbauer GmbH & Co. KG UHF Reader Indy 2k UHF Reader 170713-AU02+W01 Annex C Page 4 of 6 Picture 5: Antenna connectors – front view Picture 6: RF module with power supply – top view EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Mühlbauer GmbH & Co. KG UHF Reader Indy 2k UHF Reader 170713-AU02+W01 Annex C Page 5 of 6 Picture 7: RF module with power supply – back view Picture 8: RF module with antenna connectors – top view EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Mühlbauer GmbH & Co. KG UHF Reader Indy 2k UHF Reader 170713-AU02+W01 Annex C Page 6 of 6 Picture 9: RF module with antenna connectors – back view
All test results apply to the tested sample only. Multiplication and publication is prohibited unless written consent has been provided beforehand by the EMV TESTHAUS GmbH. RF test report 170713-AU02+W01 Mühlbauer GmbH & Co. KG UHF Reader Impinj Indy R2000 Customer: Mühlbauer GmbH & Co. KG Manfred-von-Ardenne-Ring 13 01099 Dresden Germany Tel.: +49 351 88499-300 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Mühlbauer GmbH & Co. KG UHF Reader Indy 2k UHF Reader 170713-AU02+W01 Page 2 of 51 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Tel.: +49 9421 56868-0 Fax: +49 9421 56868-100 Email: [email protected] Accreditation: Test Firm Type “accredited”: Valid until 2019-06-05 MRA US-EU, FCC designation number: DE0010 BnetzA-CAB-02/21-02/5 Valid until 2023-11-26 Recognized on March 14 th , 2019 by the Department of Innovation, Science and Economic Development (ISED) Canada as a wireless testing laboratory CAB identifier: DE0011 Test laboratory: EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany The technical accuracy is guaranteed through the quality management of EMV TESTHAUS GmbH. EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Mühlbauer GmbH & Co. KG UHF Reader Indy 2k UHF Reader 170713-AU02+W01 Page 3 of 51 Table of contents 1 Summary of test results ............................................................................................................ 6 2 Referenced publications ........................................................................................................... 7 3 Equipment under test (EUT) ..................................................................................................... 8 4 Test configuration and mode of operation ............................................................................... 10 4.1 Test configuration ............................................................................................................ 10 4.2 Mode of operation ............................................................................................................ 11 5 Measurement Procedures ...................................................................................................... 12 5.1 AC power line conducted emission .................................................................................. 12 5.2 20 dB bandwidth .............................................................................................................. 14 5.3 Occupied bandwidth (99%) .............................................................................................. 14 5.4 Spurious radiated emissions 9 kHz to 10 th harmonic ........................................................ 15 5.5 Radiated emissions ......................................................................................................... 15 6 Test results ............................................................................................................................. 23 6.1 AC powerline conducted emissions ................................................................................. 24 6.2 Field strength of fundamental wave ................................................................................. 27 6.3 Spurious radiated emissions 9 kHz to 10th harmonic ....................................................... 29 6.4 20 dB bandwidth .............................................................................................................. 45 7 Equipment calibration status ................................................................................................... 49 8 Measurement uncertainties .................................................................................................... 50 9 Revision history ...................................................................................................................... 51 10 Additional documents ............................................................................................................. 51 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Mühlbauer GmbH & Co. KG UHF Reader Indy 2k UHF Reader 170713-AU02+W01 Page 4 of 51 List of figures Figure 1: Setting of the required test mode .................................................................................... 11 Figure 2: Setup for AC power-line conducted emissions test from 150 kHz to 30 MHz .................. 13 Figure 3: Setup for radiated emissions test below 30 MHz ............................................................ 17 Figure 4: Setup for radiated emissions test from 30 MHz to 1 GHz ............................................... 19 Figure 5: Setup for radiated emissions test above 1 GHz .............................................................. 22 Figure 6: Chart of AC powerline conducted emissions on L1 ......................................................... 25 Figure 7: Chart of AC powerline conducted emissions on N .......................................................... 26 Figure 8: Chart of spurious radiated emission test 9 kHz - 30 MHz, 902.25 MHz in position X and in line ................................................................................................................................................ 32 Figure 9: Chart of spurious radiated emission test 9 kHz - 30 MHz, 912.75 MHz in position X and in line ................................................................................................................................................ 33 Figure 10: Chart of spurious radiated emission test 9 kHz - 30 MHz, 927.75 MHz in position X and in line ............................................................................................................................................. 33 Figure 11: Chart of spurious radiated emission test 30 MHz - 1 GHz, 902.25 MHz in position Z .... 35 Figure 12: Chart of spurious radiated emission test 30 MHz - 1 GHz, 912.75 MHz in posit…
Text truncated - open the document above for the full version.
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Mühlbauer GmbH & Co. KG UHF Reader Indy 2k UHF Reader 170713-AU02+W01 Annex A Page 1 of 7 1 Annex A – Test setup 1.1 List of Pictures Picture 1: EUT position X – top view ................................................................................. 2 Picture 2: EUT position Y – front view ............................................................................... 2 Picture 3: EUT position Z – front view ............................................................................... 3 Picture 4: CDC, radiated emission test 9 kHz -30 MHz – position Z (front view) ............... 3 Picture 5: SAC, radiated emission test 30 MHz – 1 GHz – position Z (front view) ............. 4 Picture 6: SAC, radiated emission test 30 MHz – 1 GHz – position Z (back view) ............ 4 Picture 7: AC, radiated emission test 1 GHz – 10 GHz – position Z (front view) ............... 5 Picture 8: AC, radiated emission test 1 GHz – 10 GHz – position Z (back view) ............... 5 Picture 9: Relative conducted measurements with tag ...................................................... 6 Picture 10: Relative conducted measurements without tag ............................................... 6 Picture 11: Conducted measurements without tag ............................................................ 7 Picture 12: Power supply used only for testing .................................................................. 7 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Mühlbauer GmbH & Co. KG UHF Reader Indy 2k UHF Reader 170713-AU02+W01 Annex A Page 2 of 7 Picture 1: EUT position X – top view Picture 2: EUT position Y – front view EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Mühlbauer GmbH & Co. KG UHF Reader Indy 2k UHF Reader 170713-AU02+W01 Annex A Page 3 of 7 Picture 3: EUT position Z – front view Picture 4: CDC, radiated emission test 9 kHz -30 MHz – position Z (front view) EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Mühlbauer GmbH & Co. KG UHF Reader Indy 2k UHF Reader 170713-AU02+W01 Annex A Page 4 of 7 Picture 5: SAC, radiated emission test 30 MHz – 1 GHz – position Z (front view) Picture 6: SAC, radiated emission test 30 MHz – 1 GHz – position Z (back view) EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Mühlbauer GmbH & Co. KG UHF Reader Indy 2k UHF Reader 170713-AU02+W01 Annex A Page 5 of 7 Picture 7: AC, radiated emission test 1 GHz – 10 GHz – position Z (front view) Picture 8: AC, radiated emission test 1 GHz – 10 GHz – position Z (back view) EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Mühlbauer GmbH & Co. KG UHF Reader Indy 2k UHF Reader 170713-AU02+W01 Annex A Page 6 of 7 Picture 9: Relative conducted measurements with tag Picture 10: Relative conducted measurements without tag EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Mühlbauer GmbH & Co. KG UHF Reader Indy 2k UHF Reader 170713-AU02+W01 Annex A Page 7 of 7 Picture 11: Conducted measurements without tag Picture 12: Power supply used only for testing
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 902.25 MHz - 927.75 MHz | - |