Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Device Quick Start Guide Device Diagram....................................................................... Accessories............................................................................... Download the App.................................................................. Pair the Device......................................................................... Preparing to Submit a Test...................................................... Submitting a Test...................................................................... Client Text Notifications........................................................... Device Operating Information............................................... Troubleshooting........................................................................ Intended Use............................................................................. Device Recalibration............................................................... Disclaimers................................................................................. Table of Contents 1 2 3 3 4 5 6 7 8 9 9 9 1 FCC ID: X3ZBTMOD4 4400045K Soberlink Device Diagram Camera Mouthpiece port Power button USB-C charging port Status light 2 Accessories Device Case Insert one end of the cable into the charging base and the other end into the port on the bottom of the Soberlink Device. Plug the charging base into an electrical outlet. Device Charger Mouthpiece To protect the Device when not in use, keep it stored in the Device Case. The Mouthpiece can be stored inside the Device Case. Insert the small, flanged end of the Mouthpiece into the Device. Note: Always use a Soberlink Mouthpiece when submitting a test. 3 Download the App 1. Download the Soberlink app. Make sure Bluetooth is enabled on the iOS or Android device. Open the Soberlink App and follow the screen prompts. Pair New Device 2. Activate your device by calling Soberlink at 714.975.7200 If you purchased Soberlink through your Treatment Provider, contact them to activate. GET IT ON Google Play 4 Preparing to Submit a Test This document, and any other provided training material, should be fully understood by the user before submitting a test. To ensure proper device function keep it fully charged. To avoid damage or injury caused by the product only use accessories provided by the manufacturer. Find an area free from alcohol, cleaners, solvent vapors, and smoke before submitting a test. Use the Device within the operating temperature range (32°F -122°F). Breathe normally before submitting a test. Remove sunglasses, hats, or other objects covering the face. Wait 20 minutes after eating, drinking, or smoking before submitting a test. Failure to wait may result in inaccurate test results. Rinsing out the mouth with water does not act as a substitute for the 20-minute waiting period. 12 6 5 4 3 2 1 9 8 7 10 11 2 4 3 2 1 WAIT 20 MINUTES NO EATING NO DRINKING NO SMOKING Before activating the Device and submitting a test, the Client is required to set up a two-factor authenticated User account. To activate call Soberlink at 714-975-7200 or contact your Treatment Provider. 5 Submitting a Test Open the Soberlink App. The App should remain open for the duration of testing. Press the Power button to turn on the Soberlink Device. Follow the prompts on the App, and wait for the green light to flash before submitting a test. When prompted to blow, look directly into the camera, breathe in deeply and deliver a firm, continuous breath for 4 seconds. The Device will click when the test is complete. Note: Do not hold the mouthpiece or obstruct the camera. The test results will take approximately 30 seconds to display on the App and send to the Sober Sky Web Portal. Once the test has successfully sent, close the App. Note: After a positive BAC (Breath Alcohol Concentration) is received, wait 15 minutes before submitting another test. 6 Client Text Notifications Once a schedule is enabled on the Sober Sky Web Portal, Soberlink’s automated system will send text message reminders directly to the Client’s phone. Reminder texts are sent before and during the test window. Missed notification after test window closes Notification of retesting requirement 49382 REMINDER TEXT: This is your 8:00 AM PST test reminder. 49382 MISSED TEST: You have missed 1 or more tests. Send a test now. 49382 RETEST REQUIRED: A test is required at 8:18 AM PST. Note: During the Client’s setup of their two-factor authenticated User account, they will consent to receive SMS alerts & notifications to be Opted-In to notifications. These preferences can be managed in their User settings. ALERTS AND NOTIFICATIONS Email Opted-In Edit SMS Opted-In Edit 7 Device Operating Information Dimensions4.75” x 2.50” x 1.25” Weight5.35 oz. (151.66 grams) Sensor TechnologyDeep lung, Dart fuel-cell sensor Battery TypeLithium-ion rechargeable battery, holds 10+ days Power SupplyUSB-C charger, Output: 5V 2A Breath Sample Duration4 seconds Operating Temperature32°F - 122°F (0°C - 50°C) Relative Humidity80% non-condensing up to 87 degrees F (31°C), decreasing linearly to 50% non-condensing at 104 degrees F (40 C°) Min. Ambient Air Pressure0.74 atm Pollution Degree2 Sensor Accuracy+/- .005 BAC Detection Range.000 - .400% BAC CalibrationEvery 1,500 tests CameraColor, low light compensation Test DataBAC, time of test, and photo ComponentsBreathalyzer, mouthpieces, charger, case ManufacturedQSR 820, ISO 9001, ISO 13485, AS9100 Warranty1 year limited Technical Specifications The user does not need to perform any tests at start up, the Device performs a self-test when it is powered on and prior to a test submission. The self-test is meant to verify the proper operation of the test storage memory, alcohol fuel cell, and imager. Failure of any of these components indicates that the Device is unable to properly record test data. In this case, an error code is displayed to the user and testing will not proceed. Safety There are no anticipated ris…
Text truncated - open the document above for the full version.
Soberlink Healthcare 7711 Center Ave, Suite 400 Huntington Beach, CA 92647 Federal Communication Commission 7435 Oakland Mills Road Columbia, MD 21046 2/3/2026 Attestation Statement according to 2.911(d)(5)(i) and 2.911(d)(5)(ii) FCC ID: 2ATA4-CNCT02 TO WHOM IT MAY CONCERN: Hereby we certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Further we certify that, as of the date of the filing of the application, Soberlink Healthcare is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, _______________ (signature & company stamp) Soberlink Healthcare 7711 Center Ave, Suite 400 Huntington Beach, CA 92647 Dan Rhodes 714-975-7200 [email protected] For information on Covered equipment, refer: • 986446 D01 Covered Equipment v01 • FCC 22-84 • List of Equipment and Services Covered By Section 2 of The Secure Networks Act | Federal Communications Commission (fcc.gov)
Soberlink Healthcare 7711 Center Ave, Suite 400 Huntington Beach, CA 92647 Federal Communication Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA 02/03/2026 Attestation Statement according to 2.911(d)(7) FCC ID: 2ATA4-CNCT02 TO WHOM IT MAY CONCERN: Soberlink Healthcare with FCC Registration Number (FRN) 0028475184 Certifies that, as of the date of this filing of the application with the TCB, Dan Rhodes is our designated US agent for service of process for the above referenced FCC ID. Soberlink Healthcare accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any commission related proceeding involving equipment. Soberlink Healthcare with FCC Registration Number (FRN) 0028475184 Accepts, as of the date of the filing of the application, the obligation of the designated US agent for service of process for the above referenced FCC ID. Sincerely, _______________ (signature & company stamp) Soberlink Healthcare 7711 Center Ave, Suite 400 Huntington Beach, CA 92647 Dan Rhodes 714-975-7200 [email protected] _______________ (signature & company stamp) Soberlink Healthcare 7711 Center Ave, Suite 400 Huntington Beach, CA 92647 Dan Rhodes 714-975-7200 [email protected]
(Insert Company Letterhead) Letter of Authorization and Anti- Drug Statement Applicant Name: Soberlink Healthcare Address: 7711 Center Ave, Hungtington Beach CA 92647 Product Name: Soberlink 7.0 Model Number: 1 FCC ID: 2ATA4-CNCT02 We authorize: CETECOM Inc., to act on our behalf on all matters concerning the above named equipment. We declare that CETECOM Inc. is allowed to forward all information related to the approval project to the Federal Communications Commission and discuss any issues concerning the approval application. The applicant must certify that neither the applicant nor any party to the application is subject to a denial of Federal benefits, that include FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. § 862 because of a conviction for possession or distribution of a controlled substance. See 47 CFR 1.2002(b) for the definition of a "party" for these purposes. Does the applicant or authorized agent so certify? ☒ Yes I certify that I am authorized to sign this application. All of the statements herein and the exhibits attached hereto, are true and correct to the best of my knowledge and belief. In accepting a Grant of Equipment Authorization as a result of the representations made in this application, the applicant is responsible for (1) labeling the equipment with the exact FCC ID specified in this application, (2) compliance statement labeling pursuant to the applicable rules, and (3) compliance of the equipment with the applicable technical rules. If the applicant is not the actual manufacturer of the equipment, appropriate arrangements have been made with the manufacturer to ensure that production units of this equipment will continue to comply with the FCC's technical requirements. Authorizing an agent to sign this application, is done solely at the applicant's discretion; however, the applicant remains responsible for all statements in this application. If an agent has signed this application on behalf of the applicant, a written letter of authorization which includes information to enable the agent to respond to the above section 5301 (Anti-Drug Abuse) Certification statement has been provided by the applicant. It is understood that the letter of authorization must be submitted to the FCC upon request, and that the FCC reserves the right to contact the applicant directly at any time. Signature of Authorized Person Filing: Title: Vice President, Device Engineering Date: 02/03/2026
Federal Communications Commission Equipment Authorization Division 7435 Oakland Mills Road Columbia, MD 21048 Date: 02/03/2026 Subject: Request for Permanent Confidentiality FCC ID: 2ATA4-CNCT02 To Whom It May Concern: In accordance with §0.457(d) and §0.459 of CFR 47, and KDB 726920, Soberlink Healthcare hereby requests permanent confidentiality for documents filed under the following exhibit types: 1. Block Diagram 2. Schematic Diagram 3. Part List 4. Operational Description These items contain detailed system and equipment description and related information about the product which Soberlink Healthcare considers to be proprietary, confidential and a custom design which otherwise would not be released to the general public. Since this design is a basis from which future technological products will evolve, Soberlink Healthcare also feels that this information would be of benefit to its competitors, and that the disclosure of the information in these exhibits would give our competitors an unfair advantage in the market. We are aware that exhibit types cover letters, attestations, label document, test reports, RF exposure information (SAR and MPE reports), cannot be requested to be classified confidential and are thus subject to publication, as will be documents of all other exhibits types for which we have not requested a confidentiality classification. Best Regards, _______________________________ Signature Name: Dan Rhodes Title: Vice President, Device Engineering Company Name: Soberlink Healthcare Address: 7711 Center Ave Suite 400, Huntington Beach CA 92647
.433 11 .639 16.22 .210 5.34 1.703 43.26 B DETAIL B SCALE 2 : 1 DEVICE NAME 4 PT LETTERS FCC ID AND IC ID 4 PT LETTERS BAR CODE AREA DEVICE ID 7 PT LETTERS HARDWARE VERSION 4 PT LETTERS D C B A A B C D 1 2 3 4 5 6 7 8 8 7 6 5 4 3 2 1 THIRD ANGLE PROJECTION 02/04/26 03/05/26 ksung ERROR!:QAApproval ksung ERROR!:QAAppDate CAD GENERATED DRAWING, DO NOT MANUALLY UPDATE SCALE SIZE CAD FILE: DWG. NO. B SHEET 3 OF 3 REV. DATE APPROVALS DRAWN CHECKED RESP ENG MFG ENG QUAL ENG UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN MM TOLERANCES ARE: DECIMALS >0.5 TO <=40 0.1MM >40 TO <=80 0.2MM >80 TO <=120 0.3MM ANGLES 0.5 MATERIAL FINISH DO NOT SCALE DRAWING APPLICATION USED ON NEXT ASSY ITEM NO. PART OR IDENTIFYING NO. NOMENCLATURE OR DESCRIPTION MATERIAL SPECIFICATION QTY REQD PARTS LIST 440-XXXXX X01 1:1 SL2 Connect Soberlink 7.0 Device Labels.SLDDRW DEVICE LABEL, SOBERLINK 7.0 SOBERLINK Notes: 1. MATERIAL: GLOSS_Lam - 1MIL SW TTP PET*(KB)
IC recognized # 3462B CETECOM Inc. 411 Dixon Landing Road Milpitas, CA 95035 U.S.A. Phone: + 1 (408) 586 6200 Fax: + 1 (408) 586 6299 E-mail: [email protected] http://www.cetecom.com CETECOM Inc. is a Delaware Corporation with Corporation number: 2905571 V5.0 2015-10-27 © Copyright by CETECOM Radio Frequency Exposure Evaluation Report For: Soberlink Healthcare Marketing Name: Soberlink 7.0 Model Number: 44000000 Product Description: Handheld Breathalyzer FCC ID: 2ATA4-CNCT02 IC: 35108-S72026 Applied Rules and Standards: CFR Part1 (1.1307 &1.1310), Part 2 (2.1091), FCC KDB 447498 D01 General RF Exposure Guidance v06 ISED RSS-102 Issue 6 Report number: EMC_SOBER_017_25001_RF_Exposure_Rev1 DATE: 2026-03-09 Test Report #: EMC_SOBER_017_25001_RF_Exposure_Rev1 FCC ID: 2ATA4-CNCT02 Date of Report 2026-03-09 Page 2 of 9 IC: 35108-S72026 TABLE OF CONTENTS 1 Assessment ........................................................................................................................................... 3 2 Administrative Data ............................................................................................................................. 4 2.1 Identification of the Testing Laboratory Issuing the EMC Test Report ................................................... 4 2.2 Identification of the Client ................................................................................................................. 4 2.3 Identification of the Manufacturer ...................................................................................................... 4 3 Equipment under Assessment .............................................................................................................. 5 3.1 EUT Specifications .......................................................................................................................... 5 4 RF Exposure Limits and FCC and ISED Basic Rules ......................................................................... 6 FCC ........................................................................................................................................................... 6 ISED RSS 102 ............................................................................................................................................ 7 5 Evaluations ........................................................................................................................................... 8 5.1 FCC RF Exposure (Standalone) ....................................................................................................... 8 5.2 ISED RF Exposure (Standalone) ..................................................................................................... 8 6 Revision History .................................................................................................................................. 9 Test Report #: EMC_SOBER_017_25001_RF_Exposure_Rev1 FCC ID: 2ATA4-CNCT02 Date of Report 2026-03-09 Page 3 of 9 IC: 35108-S72026 1 Assessment This RF Exposure evaluation report provides evidence for compliance of the below identified device with the RF Exposure limits for mobile devices as defined in FCC CFR Part 1 (1.1307 &1.1310), Part 2 (2.1091 & 2.1093) and ISED standard RSS- 102 issue 6 under worst case conditions (measured or rated RF output power, antenna gain, distance towards human body, multiple transmitter information as presented by the applicant). In addition, maximum antenna gain or minimum distance towards the human body is calculated respectively, where relevant. The device meets the limits as stipulated by the above given FCC and ISED rule parts based on available specifications for worst-case conditions at 2 cm distance to the body. Company Name Product Description Model No. Soberlink Healthcare Handheld Breathalyzer 44000000 Report Authorized by: Responsible for testing Laboratory: 2026-03-09 Compliance Alvin, Ilarina (Senior Manager Regulatory Services) Date Section Name Signature Responsible for the Report: 2026-03-09 Compliance Cheng Song (EMC Engineer) Date Section Name Signature The test results of this test report relate exclusively to the test item specified in Section3. CETECOM Inc. USA does not assume responsibility for any conclusions and generalizations drawn from the test results with regard to other specimens or samples of the type of the equipment represented by the test item. The test report may only be reproduced or published in full. Reproduction or publication of extracts from the report requires the prior written approval of CETECOM Inc. USA. Test Report #: EMC_SOBER_017_25001_RF_Exposure_Rev1 FCC ID: 2ATA4-CNCT02 Date of Report 2026-03-09 Page 4 of 9 IC: 35108-S72026 2 Administrative Data 2.1 Identification of the Testing Laboratory Issuing the EMC Test Report Company Name: CETECOM Inc. Department: Compliance Street Address: 411 Dixon Landing Road City/Zip Code Milpitas, CA 95035 Country USA Telephone: +1 (408) 586 6200 Fax: +1 (408) 586 6299 EMC Lab Manager: Alvin, Ilarina Responsible Project Leader: Ruby, Hall 2.2 Identification of the Client Client Firm/Name: Soberlink Healthcare Street Address: 7711 Center Ave Suite 400 City/Zip Code Huntington Beach, CA 92647 Country USA 2.3 Identification of the Manufacturer Manufacturer’s Name: Same as Client Manufacturers Address: City/Zip Code Country Test Report #: EMC_SOBER_017_25001_RF_Exposure_Rev1 FCC ID: 2ATA4-CNCT02 Date of Report 2026-03-09 Page 5 of 9 IC: 35108-S72026 3 Equipment under Assessment 3.1 EUT Specifications Product Description: Handheld Breathalyzer Model Name: 44000000 HW Version: 1 SW Version: 20.14 FCC-ID: 2ATA4-CNCT02 IC: 35108-S72026 FVIN N/A HVIN HW-S7-01 PMN SOBERLINK7.0 Radio Information as declared: BLE: • Silabs BG26 SoC • Operating on channels 0–39 within the 2.4 GHz ISM band (2402–2480 MHz). Antenna Information as declared: PCB trace antenna Peak Gain: 2.7 dBi Other Radios included in the device N/A Power Supply/ Rate…
Text truncated - open the document above for the full version.
IC recognized # 3462B CETECOM Inc. 411 Dixon Landing Road Milpitas, CA 95035 U.S.A. Phone: + 1 (408) 586 6200 Fax: + 1 (408) 586 6299 E-mail: [email protected] http://www.cetecom.com CETECOM Inc. is a Delaware Corporation with Corporation number: 2905571 © Copyright by CETECOM FCC / ISED Test Report For: Soberlink Healthcare Marketing Name: Soberlink 7.0 Model Number: 44000000 Product Description: Handheld Breathalyzer FCC ID: 2ATA4-CNCT02 IC: 35108-S72026 Applied Rules and Standards: 47 CFR Part 15.247 (DTS) RSS-247 Issue 4 (DTS) & RSS-Gen Issue 5 REPORT #: EMC_SOBER_017_25001_FCC_15_247_BLE_Rev1 DATE: 2026-03-09 Test Report #: EMC_SOBER_017_25001_FCC_15_247_BLE_Rev1 FCC ID: 2ATA4-CNCT02 Date of Report 2026-03-09 Page 2 of 57 IC: 35108-S72026 TABLE OF CONTENTS 1 ASSESSMENT .............................................................................................................................................................. 3 2 ADMINISTRATIVE DATA ............................................................................................................................................... 4 2.1 IDENTIFICATION OF THE TESTING LABORATORY ISSUING THE EMC TEST REPORT ........................................................................... 4 2.2 IDENTIFICATION OF THE CLIENT ............................................................................................................................................. 4 2.3 IDENTIFICATION OF THE MANUFACTURER ................................................................................................................................. 4 3 EQUIPMENT UNDER TEST (EUT) ................................................................................................................................... 5 3.1 EUT SPECIFICATIONS ......................................................................................................................................................... 5 3.2 EUT POWER SETTING ......................................................................................................................................................... 6 3.3 EUT SAMPLE DETAILS ......................................................................................................................................................... 6 3.4 ACCESSORY EQUIPMENT (AE) DETAILS ................................................................................................................................... 6 3.5 TEST SAMPLE CONFIGURATION ............................................................................................................................................. 6 3.6 MODE OF OPERATION DETAILS .............................................................................................................................................. 7 3.7 JUSTIFICATION FOR WORST CASE MODE OF OPERATION ............................................................................................................ 7 4 SUBJECT OF INVESTIGATION ...................................................................................................................................... 8 5 MEASUREMENT RESULTS SUMMARY .......................................................................................................................... 8 6 MEASUREMENT UNCERTAINTY.................................................................................................................................... 9 6.1 ENVIRONMENTAL CONDITIONS DURING TESTING: ...................................................................................................................... 9 6.2 DATES OF TESTING: ............................................................................................................................................................ 9 6.3 DECISION RULE: ................................................................................................................................................................. 9 7 MEASUREMENT PROCEDURES .................................................................................................................................. 10 7.1 RADIATED MEASUREMENT .................................................................................................................................................. 10 7.2 POWER LINE CONDUCTED MEASUREMENT PROCEDURE .......................................................................................................... 14 7.3 RF CONDUCTED MEASUREMENT PROCEDURE ....................................................................................................................... 14 8 TEST RESULT DATA .................................................................................................................................................. 15 8.1 MAXIMUM PEAK CONDUCTED OUTPUT POWER ....................................................................................................................... 15 8.2 POWER SPECTRAL DENSITY ............................................................................................................................................... 18 8.3 BAND EDGE COMPLIANCE .................................................................................................................................................. 21 8.4 EMISSION BANDWIDTH 6DB AND 99% OCCUPIED BANDWIDTH ................................................................................................... 30 8.5 RADIATED TRANSMITTER SPURIOUS EMISSIONS AND RESTRICTED BANDS ................................................................................... 36 8.6 AC POWER LINE CONDUCTED EMISSIONS ............................................................................................................................. 54 9 TEST SETUP PHOTOS ................................................................................................................................................ 56 10 TEST…
Text truncated - open the document above for the full version.
XTDCT023-00 Copyright 2025 Field Theory Consulting Inc. All Rights Reserved. Page 1 of 8 FTBLEF149 1029 Butterfield Road, Vernon Hills, IL 60061 +1 (847) 801-6330 [email protected] fieldtheoryinc.com Bluetooth Antenna Custom Built to Serve Your Unique Requirements Features: Frequency Band: 2.40 GHz – 2.48 GHz Field Theory Part Number: FTBLEF149 Contents Performance & Specifications ................................................................................................................ 2 Efficiency Pattern ................................................................................................................................... 3 Peak Gain .............................................................................................................................................. 4 1D Gain Radiation Patterns .................................................................................................................... 5 2D & 3D Gain Radiation Patterns ............................................................................................................ 6 Test Conditions ...................................................................................................................................... 7 Legal Notices ......................................................................................................................................... 8 Version: 1.0 Date: 11/10/2025 XTDCT023-00 Copyright 2025 Field Theory Consulting Inc. All Rights Reserved. Page 2 of 8 FTBLEF149 Performance & Specifications Antenna Performance Parameters Results Frequency (GHz) 2.4 2.44 2.48 Efficiency (%) 54 59 59 Peak Gain (dBi) 2.1 2.5 2.7 VSWR <2.5 <2.5 <2.5 General Specifications Antenna Type Nominal Impedance Power Handling Polarization BLE 50 Ω 10W Linear Mechanical Specifications Type Material Printed Antenna PCB XTDCT023-00 Copyright 2025 Field Theory Consulting Inc. All Rights Reserved. Page 3 of 8 FTBLEF149 Efficiency Pattern Fig 1. Typical Performance Efficiency 0 10 20 30 40 50 60 70 22.052.12.152.22.252.32.352.42.452.52.552.62.652.72.752.82.852.92.953 Frequency (%) Frequency (GHz) XTDCT023-00 Copyright 2025 Field Theory Consulting Inc. All Rights Reserved. Page 4 of 8 FTBLEF149 Peak Gain Fig 2. Typical Performance Peak Gain -10 -8 -6 -4 -2 0 2 4 22.052.12.152.22.252.32.352.42.452.52.552.62.652.72.752.82.852.92.953 Peak Gain (dBi) Frequency (GHz) XTDCT023-00 Copyright 2025 Field Theory Consulting Inc. All Rights Reserved. Page 5 of 8 FTBLEF149 1D Gain Radiation Patterns XTDCT023-00 Copyright 2025 Field Theory Consulting Inc. All Rights Reserved. Page 6 of 8 FTBLEF149 2D & 3D Gain Radiation Patterns 2.4 GHz 2.44 GHz 2.48 GHz XTDCT023-00 Copyright 2025 Field Theory Consulting Inc. All Rights Reserved. Page 7 of 8 FTBLEF149 Test Conditions Results were collected from a passive antenna measurement within a 5-meter fully anechoic antenna chamber equipped with a dual-pol quad-ridged horn receiver antenna and an EL-AZ positioner with laser positioner. Test Conducted Passive DUT SN/PN 44000006 Formula & Calculations Gain: Efficiency: Test Equipment Calibration Status Equipment Manufacturer Model No. Serial No. Last Cal. Due Date Network Analyzer Anritsu MS46122B 2135304 8/25/2025 8/25/2026 Quad-Ridge Horn Antenna ETS-Lindgreen 3164-10 217936 8/25/2025 8/25/2026 5 Meter Anechoic Chamber Braden Shielding Systems NA F70331 NA NA RF Cable ENS Microwave S160-160-MKS-MKS 3042020 8/25/2025 8/25/2026 RF Cable ENS Microwave S160-120-MKS-MKS 12042018 8/25/2025 8/25/2026 RF Cable ENS Microwave EMC1-K1K1-72 1GVT4 19002201 8/25/2025 8/25/2026 RF Cable ENS Microwave EMC1-K1K1-72 1GVT4 19002202 8/25/2025 8/25/2026 RF Cable ENS Microwave EMC1-K1K1-216 1GVT4 19002202 001 8/25/2025 8/25/2026 RF Cable ENS Microwave EMC1-K1K1-216 1GVT4 19002202 002 8/25/2025 8/25/2026 DUT Positioner DE LCC D6025 NA NA NA RF Switch Mini-Circuits RC-1SPDT-A18 1810010005 8/25/2025 8/25/2026 XTDCT023-00 Copyright 2025 Field Theory Consulting Inc. All Rights Reserved. Page 8 of 8 FTBLEF149 Legal Notices This specification sheet shall not be duplicated, used, or disclosed, in whole or in part, for any purpose. Field Theory Consulting Inc. and the Field Theory logo are registered trademarks. The information given herein, including drawings, illustrations, and schematics, are included for illustration purposes only and are believed to be accurate and reliable at the time of publishing. However, Field Theory makes no warranties as to their accuracy or completeness and disclaims any liability in connection with their use. Field Theory’s obligations shall be as set forth in Field Theory’s stan…
Text truncated - open the document above for the full version.
7711 Center Ave, Suite 400 · Huntington Beach, California, 92647 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 12.60 mW |