  3. 2ATGV-UM9030

2ATGV-UM9030AX WIFI Router

UNIONMAN TECHNOLOGY CO., LTD
AX WIFI Router - FCC ID 2ATGV-UM9030 - UNIONMAN TECHNOLOGY CO., LTD
Click to zoom

Application Details

Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
Jan 03, 2021
Application Purpose
Original Equipment
Date of Application
Jan 03, 2021
Equipment Note
AX WIFI Router
Frequency Range
5745.00000000 - 5825.00000000
Company
UNIONMAN TECHNOLOGY CO., LTD
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

IIl ©布恩总节 Power :: u ;二』 一 WPS Stat u s Indicator status discription Indicator status discription l C ol 可s I L a b e l s Power indicator I B l ue/ I WAN WPSmdlcator l B 勹二, 实 o p owersu pp l y or notin the sta te of 2.4G/5G indicato『S Status Blue 12.4G/5G � ()ff: _No _ p ower su pp l y or wireless int七rfa迈 blocked 【,l,1,,1-,I If the indicator light is not normal, please check if the connection is correct Switch o詈日 1 二`己已 I o o _ ` L ',1,阿- 1 Connectthe deviC8 Connect the LAN interface and WAN interface (community broadband) on the router with an Ethernet cable (network cable) 2 Connect to WI - Fl Use a la p to p or mobile p hone to search for the SSID corres p onding to the Wi-Fi network on the name p lat e at the bottom of the device and join it. 3 Setupthenelwork \/1sit 192.168.10.1 through the browser to com p lete the setting, and log in accortling to the account p asswortl on the bottom name p late 旦而哪,,品一 <D Power on the router, and connect the mobile p hone/com p uter to the router with a network cable or wirelessly : - 勹 : Swltch / D 』 吵p enthe browser and enter 192.168.10.1 or wifi.cmcc/ to enter the login interface @Enter the user name USER and the configuration management p assword to log in. For the configuration management p assword, see the nameplate at the bottom ©杂恩也慈 Union man Technology Co., Ltd. el:0752-2699800 Executive standard: GY/T 241-2009 Address: No.5 Huitai Road, Huinan High-Tech Industrial Park, Huizhou, Guangdong, China (516025) “AI,1Il-A _ CD Select "Netwo『K ” -"WLAN Network Configuration" @ Modify the 2.4g WIFI name in "SSID", and modify the WIFI p assword in "WPA p 『e-authenticationshared ke y " JAfler the modification is com p leted,click "SAVE" to save it and com p lete the modification of the wifi name and p assword `111II _ (l)Select "Netwo「k"-"WLAN 5g Network Configuration" ® Modify the 5g WIFI name in "SSID", and modify the WIFI p assword in "WPA p re-authentication shared ke y " 口Afterthe modification is corn p leted,click "SAVE" to save it and com p lete the modification of the wifi name and p asswo『d 1111_ Hazardous substance or element Comm n ents (Pb) ( Hg ) (Cd) (Cdr 6+ ) {PBB) (PBDE) Host X 。 。 。 。 。 C.ble_ P a o ,s we emb l y X 。 。 。 。 。 emb l y l a P d ow e a p te , , s , pp l y X 。 。 。 。 。 a d a p te p o r “ ” m a 引 er ic a nd 。 。 。 。 。 。 Metal p art, X 。 。 。 。 。 Dcy batt ecy 。 。 。 。 。 。 Rem ot e 。 。 。 。 。 。 This form is com p iled in accordance with the p rovisions oflhe SJrr11364 standard. 0 indicates that the content of this toxic and haza『doussubstance in all homogeneous materials of this p art is below the limit requirement of the G BIT standard X indicates that the content of the toxic and hazardous substance in at least one of the homogeneous materials of the p art exceeds GB IT 2 6 5 7 2 The s p ecified limit『ecjuirements. This table shows the hazardous substance information contained in this device The hazardous substance infonmation of the p arts is based on the infonmation ,「andthe internal ins p ection results. The hazardous in some p arts are im p ossible to re p lace under the current e a ctanth u n d e i prohavber陑the the ayumeonrto oftsmennot呻 p n th y e Fu ne to ma as e e ctpl E Po ct e m 穹笠芦 th me be ep eh pro th th e 3 Pt th tes so all el ce of . lcarssh d ex on n eapd sti . 01 y Fu mo ntntra g0E 0 1 _e eu 庙pon响 . IS . ISthe thsed n u andimeo g『毗etoees m nomDuovsal erup戊abual u n TheundEFrnatheact 。 宜 This p roduct bears the selective sorting symbol for Waste electrical and electronic equipment (!NEEE).This means that this p roduct must be handled according to Euro p ean directive 2012/19 /EU in order to be recycled or dismantled.This will minimize the negative effects on the environment and human health resulting from the p ossibilit y of the p resence in the equi p ment substances, mixtures and hazardous com p on七nts.Ause『cangive the p roduct to a com p etent recycling organization,to WEEE collection p oints or fo a distri-butor(in accordance with local regulations) FCC NOTICE This equi p ment has been tested and found to com p l y with the limits for a Class B digital device, p ursuant to Part 15 of the FCC Rules These limits are designed to p rovide reasonable p rotection against harmful interference in a residential installation. This equi p ment generates, uses and can radiate radio frequenc y energ y and, if not installed and used in accordance with the instructions, ma y cause harmful interference to radio communications. However, the『eis no gua rantee that interference will not occur in a p articular installation. If this equi p ment does cause harmful inte『ferenceto radio or television rece p tion, which can be determined by turning the equi p ment off and on, the user is encouraged to tr y to correct the interference by one or more of the following measures • Reorient or relocate the receiving antenna. • Increase the se p aration between the equi p ment and receiver. • Connect the equi p ment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an ex p erienced radio/TV technician for help Changes or modifications not ex p ressl y a p proved b y the part y res p onsible for com p liance could void the user's authorit y to o p erate the equi p ment This device com p lies with p art 15 of the FCC Rules. Operation is subject to the following two conditions (1)This device ma y not cause harmful interference, and (2)This device must acce p t an y interfe『encereceived, including into『ferencethat ma y cause undesired o p eration The equi p ment should be installed and o p erated with minimum distance 20cm between the radiator& your bod y . ,胃,,l_ Warranty description I. Thank you for purchasing our products. To protect the rights and interests of the purchaser, please fill in this card carefully, and read the following warranty terms carefully. 1. Please keep this warranty service card properly. If the warranty service card is lost, it will not be reissued. Plea…

Text truncated - open the document above for the full version.

Attestation Statements

Model difference declaration letter Differences Description We UNIONMAN TECHNOLOGY CO., LTD state: Product: AX WIFI Router Model Name: UNR030N,UM9030, UNR031N,UM9034 UNR032N,UM9035 The above product with same circuit, PCB layout, electrical parts, materials and wiring structures, Appearance shape, the materials of decorative accessories is same, only different color, Sincerely, Signature: Name: Shuhao Li Title: Manager Date: 12-21-2020 Company:UNIONMAN TECHNOLOGY CO., LTD Address: No.5 Huitai Road, Huinan High-Tech Industrial Park, Huizhou City, Guangdong, China

Cover Letter(s)

C5266091_X8_Ed.1 1/1 UNIONMAN TECHNOLOGY CO., LTD Company: UNIONMAN TECHNOLOGY CO., LTD Address: No.5 Huitai Road, Huinan High-Tech Industrial Park, Huizhou City, Guangdong, China Product Name: AX WIFI Router Model Number: UNR030N, UM9030, UNR031N, UM9034, UNR032N, UM9035 FCC Identifier: 2ATGV-UM9030 We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Sincerely, Signature: Name: Shuhao Li Title: Manager Date: 21 Dec , 2020

Cover Letter(s)

C5266091_X10_Ed.2 1/1 UNIONMAN TECHNOLOGY CO., LTD Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 21 Dec, 2020 Subject: Request for Confidentiality FCC ID: 2ATGV-UM9030 To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual ☐ NOTE 1 ☐ Internal Photos ☐ NOTE 1 ☐ Parts List / Tune Up ☒ ☐ RF Exposure Info No No Operational Description ☐ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No NOTE 1: Long-Term Confidentiality may be permitted under special conditions (See II. LONG-TERM CONFIDENTIALITY, Section 3 of KDB 726920, use last in force) NOTE 2: Short-Term Confidentiality can be requested for a maximum of 180 days from the date of the grant. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In case of short-term Confidentiality, the applicant requests the exhibits selected above are withheld from public view for a period of ______ days from the date of the Grant of Equipment Authorization and prior to marketing. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. C5266091_X10_Ed.2 1/1 Sincerely, Signature: Name: Shuhao Li Title: Manager

External Photos

Page 1 of 3 Report No.:FCS202012014 External photos Photo 1 Photo 2 Page 2 of 3 Report No.:FCS202012014 Photo 3 2.4G WIFI antenna 5G WIFI antenna Photo 4 Page 3 of 3 Report No.:FCS202012014 Photo 5 Photo 6

ID Label/Location Info

Label and Label Location FCC ID: 2ATGV-UM9030 L*W: 10mm*5mm White label and black font

Internal Photos

Page 1 of 3 Report No.:FCS202012014 Photo 1 Photo 2 TX RX TX RX 5G wifi antenna 2.4G WIFI antenna Page 2 of 2 Report No.:FCS202012014 Photo 3 Photo 4 Page 3 of 3 Report No.:FCS202012014 Photo 4 WiFi 5G antenna port WiFi 2.4G antenna port

RF Exposure Info

Page 1 of 2 Report No.: FCS202012014W0201/02 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com FCC RF Exposure EUT Description: Model No.: UNR030N, UM9030, UNR031N, UM9034, UNR032N, UM9035 FCC ID: 2ATGV-UM9030 Equipment type: fixed equipment 1. Limits The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b) Limits for Maximum Permissible Exposure (MPE) F = frequency in MHz Formula: Pd = (Pout*G)/(4*π*r 2 ) Where : Pd = power density in mW/cm 2 , Pout = output power to antenna in mW; G = gain of antenna in linear scale, π= 3.14; R = distance between observation point and center of the radiator in cm Pd id the limit of MPE, 1 mW/cm2. If we know the maximum gain of the antenna and the total power input to the antenna, through the calculation, we will know the distance r where the MPE limit is reached. 2. Test Procedure AX WIFI Router Page 2 of 2 Report No.: FCS202012014W0201/02 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com Software provided by client enabled the EUT to transmit and receive data at lowest, middle and highest channel individually. 3. Test Result of RF Exposure Evaluation 2.4G WIFI Output power (dBm/ mW) 802.11b 16.18/41.495 802.11g 14.57/28.642 802.11n(20MHz) 14.39/27.479 802.11n(40MHz) 13.23/21.038 5G WIFI Output power (dBm/ mW) U-NII-1 18.51/70.95 U-NII-3 15.94/39.26 Turn-up power Mode Peak power range(dBm) 2.4G WIFI 13.00-17.00 5.8G WIFI 15.00-19.00 WIFI Output power (dBm/ mW) Antenna Gain(dBi) Power Density at R=20cm (mW/cm 2 ) Limit (mW/cm 2 ) Result 2.4G WIFI 17.00/50.12 1.0 0.01255 1.0 Pass 5GWIFI 19.00/79.43 1.0 0.01989 1.0 Pass Conclusion: No SAR is required

Test Report

FCC Test Report Report No: FCS202012014W02 Issued for UNIONMAN TECHNOLOGY CO., LTD No.5 Huitai Road, Huinan High-Tech Industrial Park, Huizhou City, Guangdong, China. Product Name: AX WIFI Router Brand Name: NA Model Name: UNR030N Series Model: UM9030,UNR031N,UM9034 UNR032N,UM9035 FCC ID: 2ATGV-UM9030 Issued By: Flux Compliance Service Laboratory Add: Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com Page 2 of 78 Report No.: FCS202012014W02 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com TEST RESULT CERTIFICATION Applicant’s Name ................... : UNIONMAN TECHNOLOGY CO., LTD Address .................................. : No.5 Huitai Road, Huinan High-Tech Industrial Park, Huizhou City, Guangdong, China. Manufacture's Name .............. : UNIONMAN TECHNOLOGY CO., LTD Address .................................. : No.5 Huitai Road, Huinan High-Tech Industrial Park, Huizhou City, Guangdong, China. Product Description Product Name ........................ : AX WIFI Router Model Name........................... : UNR030N Series Model .......................... : UM9030,UNR031N,UM9034 UNR032N,UM9035 Test Standards ....................... : CFR 47 FCC Part15E section 15.407 Test Procedure ....................... : ANSI C63.10-2013 KDB 789033 D02 General UNII Test procedures New Rules 02 KDB558074 D01 Meas Guidance v05 This device described above has been tested by Flux Compliance Service Laboratory, the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of Flux Compliance Service Laboratory, this document may be altered or revised by Flux Compliance Service Laboratory, personal only, and shall be noted in the revision of the document.. Date of Test ............................. : Date (s) of performance of tests : Dec. 08, 2020 to Dec. 17, 2020 Date of Issue ............................ : Dec. 17, 2020 Test Result ............................... : Pass Tested by : (Scott Shen) Reviewed by : (Duke Qian) Approved by : (Kait Chen) Page 3 of 78 Report No.: FCS202012014W02 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com Table of Contents Page 1. SUMMARY OF TEST RESULTS 6 1.1 TEST FACTORY 7 1.2 MEASUREMENT UNCERTAINTY 7 2. GENERAL INFORMATION 8 2.1 GENERAL DESCRIPTION OF THE EUT 8 2.2 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 10 2.3 DESCRIPTION OF NECESSARY ACCESSORIES AND SUPPORT UNITS 12 2.4 EQUIPMENTS LIST 13 3. 26DB BANDWIDTH, 6DB BANDWIDTH AND 99% BANDWIDTH 14 3.1 LIMIT 14 3.2 TEST PROCEDURE 14 3.3 TEST SETUP 14 3.4 TEST RESULTS 15 4 CONDUCTED OUTPUT POWER 31 4.1 LIMIT 31 4.2 TEST PROCEDURE 31 4.3 TEST SETUP 31 4.4 TEST RESULTS 32 5. POWER SPECTRAL DENSITY 33 5.1 LIMIT 33 5.2 TEST PROCEDURE 33 5.3 TEST SETUP 34 5.4 TEST RESULTS 34 5.5 ORIGINAL TEST DATA 35 6. FREQUENCY STABILITY MEASUREMENT 49 6.1 LIMIT 49 6.2 TEST PROCEDURE 49 6.3 TEST SETUP 49 6.4 TEST RESULTS 50 50 Page 4 of 78 Report No.: FCS202012014W02 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com Table of Contents Page 7. BAND EDGE 51 7.1 LIMIT 51 7.3 TEST SETUP 52 7.5 TEST RESULTS 53 7.5 ORIGINAL TEST DATA 53 8. DUTY CYCLE 65 8.1 TEST REQUIREMENT 65 8.2 TEST PROCEDURE 65 7.3 TEST SETUP 65 8.4 TEST RESULTS 66 9 RADIATED EMISSION MEASUREMENT 67 10 CONDUCTED EMISSION TEST 74 11. ANTENNA REQUIREMENT 78 11.1 STANDARD REQUIREMENT 78 11.2 RESULT 78 Page 5 of 78 Report No.: FCS202012014W02 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com Revision History Rev. Issue Date Report NO. Effect Page Contents 00 Dec. 17,2020 FCS202012014W02 ALL Initial Issue Page 6 of 78 Report No.: FCS202012014W02 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: Standard Section Test Item Judgment Remark FCC 15.407 (e) 6/26db Bandwidth and 99% Bandwidth PASS -- FCC 15.407 (a) Maximum Conducted Output Power PASS -- FCC 15.407 (a) Power Spectral Density PASS -- FCC 15.407 (g) Frequency Stability Measurement PASS FCC 15.407 (a) FCC 15.209 FCC 15.205 Emissions in restricted frequency bands PASS FCC 15.407 (a) FCC 15.209 FCC 15.205 Band Edge Compliance PASS FCC 15.207 Power Line Conducted Emission PASS FCC 15.203 Antenna requirement PASS -- Page 7 of 78 Report No.: FCS202012014W02 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com 1.1 TEST FACTORY Company Name: Flux Compliance Service Laboratory Address: Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Telephone: +86-769-27280901 Fax: +86-769-27280901 FCC Test Firm Registration Number: 514908 Designation number: CN0127 A2LA accreditation number:5545.01 1.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ±U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=…

Text truncated - open the document above for the full version.

Test Setup Photos

Page 1 of 2 Report No.:FCS202012014 Above 1GHz for radiated emission test setup Blow 1GHz for radiated emission test setup Page 2 of 2 Report No.:FCS202012014 Conduction emission test setup

Contact Information

Applicant

Shuhao Li
[email protected]13556222585Fax: +86 752-3219929

Technical Contact

Flux Compliance Service LaboratoryAndy Yue
[email protected]86-769-27280901

Dongguan · China

Non-Technical Contact

Flux Compliance Service LaboratoryAndy Yue
[email protected]86-769-27280901

Test Firm

Flux Compliance Service LaboratoryAndy Yue
[email protected]13510297284

Technical Specifications

#Rule PartsFrequency RangePower Output
215E5.75 GHz - 5.83 GHz39.30 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End-users must be provided with operating procedures for satisfying RF exposure compliance.The device contains 20MHz, 40MHz and 80MHz bandwidth.

Other Applications from UNIONMAN TECHNOLOGY CO., LTD

2ATGV-UM-T5RF3

AX3000 Dual Band Wi-Fi6 Router

Jul 25, 2022

Equipment Class

DTS - Digital Transmission System