Wireless Dock Features SAVE THESE INSTRUCTIONS Warranty At Ubio Labs, we are dedicated to designing and manufacturing products with superior performance and 100% customer satisfaction. All of our products come with a 1 year limited warranty from date of purchase. We are always improving our products’ features and functionality. We reserve the right to change product specifications at any time without notice. DO NOT RETURN TO THE STORE Our customer service team is here to help. Important Safety Instructions Technical Specifications 5 6 7 Technical Specifications Wall Adapter Features Folding Wall Prongs 6 Ft. Cable User Manual and Safety Instructions Wireless Charging Stand For iPhone ® and Apple Watch ® iPhone, AirPods, AirPods Pro, Wireless Charging Case, and Apple Watch are trademarks of Apple Inc., registered in the U.S. and other countries. Model: AWC1066 Input: 18V DC, 3.5A Output (Wireless): 5-10W Output (Magnetic Charger): 5W Output (USB-C PD): 5V DC, 3.0A / 9V, 2.0A 18W Output (USB-A): 5V DC, 2.4A 12W Charge Indicators: White/amber LED indicator* Dimensions: 108mm x 210mm x 90mm (4.3 x 8.3 x 3.5 in) Weight: 300 g (10.6 oz) Your wireless stand is designed to provide optimal power delivery for your wireless device: • 10W Qi certified fast charging for Samsung Galaxy S6 and later, Samsung Note5 and later, Motorola, LG • 7.5W wireless charging for iPhone 8 and later • 5W wireless charging for other compatible devices • All Apple Watch Models • Wireless Charging Case for AirPods® and AirPods Pro™ IMPORTANT, RETAIN FOR FUTURE REFERENCE: READ CAREFULLY * A blinking amber LED indicates a foreign object has been detected (metal objects like keys, coins, magnets, etc.) and the device is automatically turned o to ensure safety. Removal of foreign object and proper alignment of phone will result in normal operation. Model: CHG1147 Input: 110-240V AC, 50-60 Hz, 1.3 A Output: 63W, DC 18V, 3.5A Max Dimensions: 70 x 70 x 29 mm (2.8 x 2.8 x 1.1 in) Weight: 177 g (6.5 oz) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Caution: The user is cautioned that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement The device has been evaluated to meet general RF exposure requirement. To maintain compliance with RSS102 — Radio Frequency (RF) Exposure guidelines, this equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body. Cet équipement est conforme aux limites d'exposition de rayonnement d'IC RSS-102 déterminées pour un environnement non contrôlé. Cet équipement devrait être installé et actionné avec la distance minimum 20 cm entre le radiateur et votre corps. 1 ) Apple Watch Charging Module 2 ) Watch Band Loop 3 ) Wireless Charging Surfaces 4 ) LED Charge Indicators 5 ) USB-A Output 6 ) DC Power In 7 ) USB-C Output Features 4 1 2 3 k=100 User Manual Material 80G woodfree pap er Process: 1c/1c www.ubi olabs.com support@ubiolabs .com 1-866-64 2-4428 (Mon day - Fr iday 9am - 4:30pm PST) 2821 No rthup Way, S uite 250 Belle vue, WA 980 04 Model:
UBIOLABS,INC. AgentAuthorization Company:UBIOLABS,INC. Address:2821NorthupWay,Suite250,Bellevue,WA98004USA ProductName: WirelessChargingStand TradeName: ModelNumber(s):AWC1066SG,AWC1066AW,AWC1066WG,AWC1066PG ProductDescription:WirelessChargingStand WeauthorizeMiCOMLabsInc.,575BoulderCourt,Pleasanton,California94566,USA, toactonourbehalfonallmattersconcerningthecertificationofabovenamed equipment. WedeclarethatMiCOMLabsInc.isallowedtoforwardallinformationrelatedtothe approvalandcertificationofequipmenttotheregulatoryagenciesasrequiredandto discussanyissuesconcerningtheapprovalapplication.Anyandallactscarriedoutby MiCOMLabsonourbehalfshallhavethesameeffectasactsofourown. Signature: Date: 2020-03-06 Name: Title: Company: UBIOLABS,INC. Jesse Manager
UBIO LABS, INC Declaration Letter Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 Yours sincerely, Company Officer : UBIO LABS, INC. Signature : Telephone Number : 13751410959 Email : [email protected] 3/6/20 FCC ID: 2ATGY-AWC1066 Model No:AWC1066AW, AWC106 6WG, AWC1066PG, AWC1066SG. All are same, just diffe rent with color. Pursuant to KDB 680106 of the Commission’s Rules, UBIO LABS, INChereby declare our product which is an inductive wireless power transfer applications that meet all of the following requirements are excluded from submitting an RF exposure evaluation. 1)Power trans fer frequenc y is 0.1237MHz ,0.12875MH z, 0.1335 MHz which is less than1 MHz 2)Output pow er from each primary co il is 10W which is l ess than 15 watts 3)Client devic e is placed directly in co ntact with th e transmitte r 4)The transfer system includes only three primarycoils 5)The EUT is a mobile device. 6)The aggreg ate H-field s trengths at 15 cm surroundin g the device and 20 c m above the top surface from all simultan eous tran smitting coi ls are demo nstrated to be less tha n 50% of the MPE lim it.
UBIOLABS,INC. OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:2020.03.06 Subject;RequestforConfidentiality FCCID:2ATGY-AWC1066 ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthesedocuments mightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantageinthemarket. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. It is our understan ding that a ll measur emen t test reports, FC C I D lab el format a nd c orresp ond ence during the certif icatio n rev iew p roces s can not b e gran ted as co nfide ntial d ocum ents and th is in forma tion will be available for p ublic revie w onc e the grant of e quipm ent a uthori zatio n is is sued. S incere ly, Sig n atu re : Na m e:J ess e Titl e :M anager
APPENDIX-PHOTOGRAPHSOFEUTCONSTRUCTIONALDETAILS
AWC1066AW AWC1066PG AWC1066SG AWC1066WG
APPENDIX-PHOTOGRAPHSOFEUTCONSTRUCTIONALDETAILS Induction coil-1 Inductioncoil-02 Inductioncoil-03
FCCID:2ATGY-AWC1066 1.MeasuringStandard FCCPart1(1.1310)andPart2(2.1091) 1.2.Requiments ThreedifferentcategoriesoftransmittersaredefinedbytheFCCinOETBulletin65.These categoriesarefixedinstallation,mobile,andportableandaredefinedasfollows:oFixed Installations:fixedlocationmeansthatthedevice,includingitsantenna,isphysicallysecuredata permanentlocationandisnotabletobeeasilymovedtoanotherlocation.Additionally,distance tohumansfromtheantennaismaintainedtoatleast2meters.oMobileDevices:amobiledevice isdefinedasatransmittingdevicedesignedtobeusedinotherthanfixedlocationsandtobe generallyusedinsuchawaythataseparationdistanceofatleast20centimetersisnormally maintainedbetweenthetransmitter'sradiatingstructuresandthebodyoftheuserornearby persons.Transmittersdesignedtobeusedbyconsumersorworkersthatcanbeeasilyre-located, suchasawirelessmodemoperatinginalaptopcomputer,are consideredmobiledevicesiftheymeetthe20centimeterseparationrequirement.TheFCCrules forevaluatingmobiledevicesforRFcompliancearefoundin47CFR§2.1091.oPortable Devices:aportabledeviceisdefinedasatransmittingdevicedesignedtobeusedsothatthe radiatingstructure(s)ofthedeviceis/arewithin20centimetersofthebodyoftheuser.Portable devicerequirementsarefoundinSection2.1093oftheFCC'sRules(47CFR§2.1093).TheFCC alsocategorizestheuseofthedeviceasbasedupontheuser’sawarenessandabilitytoexercise controloverhisorherexposure. ThetwocategoriesdefinedareOccupational/ControlledExposureandGeneral Population/UncontrolledExposure.Thesetwocategoriesaredefinedasfollows: Occupational/ControlledExposure:Ingeneral,occupational/controlledexposurelimitsare applicabletosituationsinwhichpersonsareexposedasaconsequenceoftheiremployment, whohavebeenmadefullyawareofthepotentialforexposureandcanexercisecontrolovertheir exposure.Thisexposurecategoryisalsoapplicablewhentheexposureisofatransientnature duetoincidentalpassagethroughalocationwheretheexposurelevelsmaybehigherthanthe generalpopulation/uncontrolledlimits,buttheexposedpersonisfullyawareofthepotentialfor exposureandcanexercisecontroloverhisorherexposurebyleavingtheareaorbysomeother appropriatemeans.AwarenessofthepotentialforRFexposureinaworkplaceorsimilar environmentcanbeprovidedthroughspecifictrainingaspartofaRFsafetyprogram.If appropriate,warningsignsandlabelscanalsobeusedtoestablishsuchawareness byprovidingprominentinformationontheriskofpotentialexposureandinstructionsonmethods tominimizesuchexposurerisks.GeneralPopulation/UncontrolledExposure:Thegeneral population/uncontrolledexposurelimitsareapplicabletosituationsinwhichthegeneralpublic maybeexposedorinwhichpersonswhoareexposedasaconsequenceoftheiremployment maynotbemadefullyawareofthepotentialforexposureorcannotexercisecontrolovertheir exposure.Membersofthegeneralpublicwouldcomeunderthiscategorywhenexposureisnot employment-related;forexample,inthecaseofawirelesstransmitterthatexposespersonsinits vicinity.Warninglabelsplacedonlow-powerconsumerdevicessuchascellulartelephonesare notconsideredsufficienttoallowthedevicetobeconsideredundertheoccupational/controlled category,andthegeneralpopulation/uncontrolledexposurelimitsapplytothesedevices. 1.3Testconfiguration 1,ThefieldstrengthofbothE-fieldandH-fieldwasmeasuredat10cmusingtheequipmentlist abovefordeterminingcompliancewiththeMPErequirementsofFCCPart1.1310. 2,TheRFpowerdensitywasmeasuredatUndermaximumloadtest 3,MaximumE-fieldandH-fieldmeasurementsweremade10cmfromeachsideoftheEUT. AlongthesideoftheEUTandstill10cmawayfromtheedgeoftheEUT,thefieldprobes werepositionedatthelocationwherethereismaximumfieldstrength.ThemaximumE-field andH-fieldisreportedbelow. 4,Thisdeviceusesawirelesschargingcircuitforpowertransferoperatingatthefrequencyof 110–205kHz.Thus,the300kHzlimitswereused:E-fieldLimit=614(V/m);H-fieldlimit=1.63 (A/m). 1.4TestSetup 2.Limits 3.MEASURINGDEVICEANDTESTEQUIPMENT 2.1ForMPEMeasurement Equipment Manuf acture r ModelNo. Serial No. LastCal.Cal.Interval E-Field Probe(100kHz-3GHz) NardaEF0391Q15221May16,20201Year H-Field Probe(300KHz-30MHz) NardaHF3061Q15835May16,20201Year BroadbandFieldMeterNardaNBM-550Q201455May16,20201Year AdapterN/ASAW30-120-2500UN/AN/AN/A LoadN/AN/AN/AN/AN/A 4.MeasuringResults EUT: WirelessChargingStand ModelName.: AWC1066SG Temperature:26°CRelativeHumidity:54% Pressure:1010hPaTestDate:2020-03-06 TestVoltage:Input:AdapterAC120V/60Hz.Output:DC18V TestMode:133.5KHz/Fullload Table1.E-FieldMPE E-FieldMeasurement(10cm) EUT Side Wireless Charge ProbeB (V/m) ProbeA (V/m) ProbeC (V/m) ProbeD (V/m) ProbeE (V/m) Limits (V/m) Full load 1 0.160.160.160.161.27 614 2 0.150.160.160.141.23 3 0.150.140.130.161.23 finaltestvalue 0.160.140.150.051.26 Table2.H-FieldMPEData H-FieldMeasurement(10cm) EUTSide Wireless Charge ProbeB (A/m) ProbeA (A/m) ProbeC (A/m) ProbeD (A/m) ProbeR (A/m) Limits (A/m) Fullload 1 0.090.080.080.080.25 1.63 2 0.070.060.060.060.21 3 0.070.050.060.060.23 finaltestvalue 0.080.070.080.070.25 EUT: WirelessChargingStand ModelName.: AWC1066SG Temperature:26 °C RelativeHumidity:54% Pressure:1010hPaTestDate:2020-03-06 TestVoltage:Input:AdapterAC120V/60Hz.Output:DC18V TestMode:128.75KHz/Halfload Table1.E-FieldMPE E-FieldMeasurement(10cm) EUTSide Wireless Charge ProbeB (V/m) ProbeA (V/m) ProbeC (V/m) ProbeD (V/m) ProbeE (V/m) Limits (V/m) Fullload 1 0.150.130.130.131.21 614 2 0.160.140.150.141.20 3 0.140.140.130.151.19 finaltestvalue 0.150.150.150.151.22 Table2.H-FieldMPEData H-FieldMeasurement(10cm) EUT Side Wireless Charge ProbeB (A/m) ProbeA (A/m) ProbeC (A/m) ProbeD (A/m) ProbeR (A/m) Limits (A/m) Full load 1 0.060.080.070.080.24 1.63 2 0.060.050.050.050.19 3 0.060.050.060.050.20 finaltestvalue 0.070.060.060.060.24 EUT: WirelessChargingStand ModelName.: AWC1066SG Temperature:26 °C RelativeHumidity:54% Pressure:1010hPaTestDate:2020-03-06 TestVoltage:Input:AdapterAC120V/60Hz.Output:DC18V TestMode:123.7KHz/Nullload Table1.E-FieldMPE E-FieldMeasurement(10cm) EUT Side Wireless Charge ProbeB (V/m) ProbeA (V/m) ProbeC (V/m) ProbeD (V/m) ProbeE (V/m) Limits (V/m) Full load 1 0.130.140.130.131.22 614 …
Text truncated - open the document above for the full version.
ReportNo.:DGE200107002D01 Version.1.1Page 1 of 25 FCCTestReport FCCID: 2ATGY-AWC1066 PRODUCTDESIGNATION: WirelessChargingStand TRADENAME: MODELNAME: AWC1066SG FAMILYMODEL: AWC1066AW,AWC1066WG,AWC1066PG CLIENT: UBIOLABS,INC. DATEOFISSUE: Mar.06,2020 STANDARD(S): FCCPart15SubpartC REPORTNO.: DGE200107002D01 Preparedfor UBIOLABS,INC. 2821NorthupWay,Suite250,Bellevue,WA98004USA Preparedby ShenzhenNTEKTestingTechnologyCo.,Ltd. 1/F,BuildingE,FendaSciencePark,SanweiCommunity,XixiangStreet, Bao’anDistrict,ShenzhenP.R.China Tel.:+86-0755-61156588Fax.:+86-0755-61156599 Website:www.ntek.org.cn ReportNo.:DGE200107002D01 Version.1.1Page 2 of 25 TESTRESULTCERTIFICATION Applicant’sname .................... : UBIOLABS,INC. Address ...................................... : 2821NorthupWay,Suite250,Bellevue,WA98004USA Manufacturer'sName.............: UBIOLABS,INC. Address ...................................... : 2821NorthupWay,Suite250,Bellevue,WA98004USA Productdescription Productname............................... : WirelessChargingStand Modeland/ortypereference . : AWC1066SG,AWC1066AW,AWC1066WG,AWC1066PG Standards..................................: FCCRulesandRegulationsPart15SubpartCSection15.207,15.209, 15.203 ANSIC63.10:2013 ThisdevicedescribedabovehasbeentestedbyShenzhenNTEKTestingTechnologyCo.,Ltd.,andthetest resultsshowthattheequipmentundertest(EUT)isincompliancewiththeFCCrequirements.Anditis applicableonlytothetestedsampleidentifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenNTEKTesting TechnologyCo.,Ltd.,thisdocumentmaybealteredorrevisedbyShenzhenNTEKTestingTechnologyCo., Ltd.,personnelonly,andshallbenotedintherevisionofthedocument. Thetestresultsofthisreportrelateonlytothetestedsampleidentifiedinthisreport. DateofTest...............................................: Date(s)ofperformanceoftests ............... : 02Mar.2020~06Mar.2020 DateofIssue..............................................: 06Mar.2020 TestResult..................................................:Pass TestingEngineer: (EileenLiu) TechnicalManager: (JasonChen) AuthorizedSignatory: (SamChen) ReportNo.:DGE200107002D01 Version.1.1Page 3 of 25 TableofContentsPage 1.TESTSUMMARY .................................................................................................................... 4 1.1FACILITIESANDACCREDITATIONS.......................................................................................5 1.2LABORATORYACCREDITATIONSANDLISTINGS..............................................................5 1.3MEASUREMENTUNCERTAINTY............................................................................................5 2.GENERALINFORMATION...................................................................................................7 2.1GENERALDESCRIPTIONOFEUT .......................................................................................... 7 2.2DESCRIPTIONOFTESTMODES ............................................................................................ 8 2.3DESCRIPTIONOFTESTSETUP ............................................................................................. 9 2.4DESCRIPTIONTESTPERIPHERALANDEUTPERIPHERAL ......................................... 10 2.5MEASUREMENTINSTRUMENTSLIST ................................................................................. 11 3.EMCEMISSIONTEST........................................................................................................12 3.1CONDUCTEDEMISSIONMEASUREMENT........................................................................12 POWERLINECONDUCTEDEMISSION ............................................................................. 12 3.1.1TESTPROCEDURE.......................................................................................................13 3.1.2TESTSETUP...................................................................................................................13 3.1.3EUTOPERATINGCONDITIONS ................................................................................. 13 3.1.4TESTRESULTS..............................................................................................................14 3.2RADIATEDEMISSIONMEASUREMENT..............................................................................16 3.2.1LIMITSOFRADIATEDEMISSIONMEASUREMENT................................................16 3.2.2TESTPROCEDURE ......................................................................................................... 17 3.2.3TESTSETUP.....................................................................................................................18 3.2.4TESTRESULTS................................................................................................................19 4.BANDWIDTH ......................................................................................................................... 24 4.1.MEASUREMENTPROCEDURE............................................................................................24 4.2.MEASUREMENTRESULTS...................................................................................................24 5.ANTENNAAPPLICATION...................................................................................................24 5.1.AntennaRequirement ............................................................................................................... 25 5.2.Result .......................................................................................................................................... 25 ReportNo.:DGE200107002D01 Version.1.1Page 4 of 25 1.TESTSUMMARY Testproceduresaccordingtothetechnicalstandards: EMCEmission StandardTestItemFCCRulesLimitJudgmentRemark FCCpart15C ANSIC63.10:2013 Conducted Emission §15.207ClassBPASS Radiated Emission §15.209ClassBPASS ANTENNA APPLICATION §15.203/PASS NOTE: (1)’N/A’denotestestisnotapplicableinthisTestReport (2)Forclient’srequestandmanualdescription,thetestwillnotb…
Text truncated - open the document above for the full version.
RadiatedMeasurementPhotos ConductedMeasurementPhotos
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.1237 MHz - 0.1335 MHz | - |

Wireless Charging Stand
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Wireless Charging Pad
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Power Bank
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Wireless Charging Stand
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Wireless Charging Pad
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz