FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. UBIO LABS, INC./
  3. 2ATGY-PWB1085

2ATGY-PWB1085Power Bank

UBIO LABS, INC.
Power Bank - FCC ID 2ATGY-PWB1085 - UBIO LABS, INC.
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Feb 19, 2020
Application Purpose
Original Equipment
Date of Application
Feb 19, 2020
Equipment Note
Power Bank
Frequency Range
0.11000000 - 0.20500000
Company
UBIO LABS, INC.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

PBB196 User Manual Material 80G woodfree paper Process: 1c/1c k=100 User Manual

Cover Letter(s)

UbioLabs,Inc. Address:2821NorthupWay,Suite250,Bellevue,Washington,UnitedStates,98004USA Tel.:425-591-9529 Fax:425-329-6262 E-mail:[email protected] QA-FR-170-B FCCAuthorization Date:2020-01-16 FEDERALCOMMUNICATIONSCOMMISSIONS AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Subject:AgentAuthorization Towhomitmayconcern: We,UbioLabs,Inc.herebyauthorizesBayAreaComplianceLaboratoriesCorporationto actonitsbehalfinallmattersrelatingtoapplicationforEquipmentauthorization, includingthesigningofalldocumentsrelatingtothesematters.Allactscarriedoutby BayAreaComplianceLaboratoryCorporationonourbehalfshallhavethesameeffect asourownaction. We,UbioLabs,Inc.theundersigned,herebycertifythatwearenotsubjecttoadenial offederalbenefits,thatincludesFCCbenefits,pursuanttoSection5301oftheAnti-Drug AbuseActof1988,21U.S.C.862. Thisauthorizationisvaliduntilfurtherwrittennoticefromtheapplicant. SincerelyYours, Signature Name : JasonLemenlson Tittle : President

Cover Letter(s)

UbioLabs,Inc. Address:2821NorthupWay,Suite250 , Bellevue , Washington , UnitedStates , 98004USA Tel.:425-591-9529 Fax:425-329-6262 E-mail:[email protected] FCCConfidentialAuthorization Date:2020-01-16 FEDERALCOMMUNICATIONSCOMMISSIONS AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Subject:ConfidentialityRequestregardingapplicationforcertificationof FCCID:2ATGY-PWB1085 InaccordancewithSections0.457and0.459oftheCommission’sRules,UbioLabs,Inc. herebyrequestslong-termconfidentialtreatmentofinformationaccompanyingthis applicationasoutlinedbelow: BlockDiagram  Schematics  OperationDescription Theabovematerialscontainproprietaryandconfidentialinformationnotcustomarily releasedtothepublic.Thepublicdisclosureofthesematerialsprovidesunjustified benefitstoitscompetitorsinthemarket. SincerelyYours, Signature Name : JasonLemenlson Tittle : President

Cover Letter(s)

Ubio Labs, Inc. Address: 2821 Northup Way, Suite 250,Bellevue,Washington,United States,98004 USA Tel.: 425‐591‐9529 Fax: 425‐329‐6262 E‐mail: [email protected] Product Similarity Declaration 2020-01-17 To: FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Dear Sir/Madam, We, Ubio Labs, Inc. hereby declare that we have a product named as Power Bank (Model: PWB1085, FCC ID: 2ATGY-PWB1085) was tested by BACL, Meanwhile, for our marketing purpose, we would like to list a series model (PWB1085SG, PWB1085XX (XX would be any Arabian number or English letter or blank ) on reports and certificate. The three models have the same circuit. The differences are as follows: 1.The model names and colors. We confirm that all information above is true, and we’ll be responsible for all the consequences. Please contact me if you have any question. Sincerely Yours, Signature: Name: Jason Lemenlson Tittle: President )

External Photos

EXHIBIT B - EUT EXTERNAL PHOTOGRAPHS

ID Label/Location Info

EXHIBIT A - FCC ID LABEL AND LOCATION FCC ID Label FCC ID Label Location Information The label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time purchase (Labeling requirements per 2.925)

Internal Photos

EXHIBIT C - EUT INTERNAL PHOTOGRAPHS ANT IC Chip

RF Exposure Info

Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RGMA191225001-00B FCC Part 15C Page 9 of 21 FCC §1.1310, §2.1091- MAXIMUM PERMISSIBLE EXPOSURE (MPE) Applicable Standard According to subpart §1.1310, systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. Limits for Maximum Permissible Exposure (MPE) (§1.1310, §2.1091) (B) Limits for General Population/Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm 2 ) Averaging Time (minutes) 0.3–1.34 614 1.63 *(100) 30 1.34–30 824/f 2.19/f *(180/f²) 30 30–300 27.5 0.073 0.2 30 300–1500 / / f/1500 30 1500–100,000 / / 1.0 30 f = frequency in MHz; * = Plane-wave equivalent power density; According with KDB 680106 D01 RF Exposure Wireless Charging Apps v03 clause 3 c) According to KDB 680106 D01 RF Exposure Wireless Charging App v03 clause 5 b) Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RGMA191225001-00B FCC Part 15C Page 10 of 21 Block Diagram of Test Setup Note: 20 cm for Top test. Test Data Environmental Conditions Temperature:25C Relative Humidity: 65 % ATM Pressure: 101.0 kPa The testing was performed by Yates Li on 2020-01-10. Test mode: Transmitting &discharging (full load) H-Filed Strength Frequency Range (kHz) Position A (A/m) Position B (A/m) Position C (A/m) Position D (A/m) Position E (A/m) 50% Limit (A/m) Limit Te s t (A/m) 110-205 0.130 0.123 0.124 0.126 0.135 0.815 1.63 15cm Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RGMA191225001-00B FCC Part 15C Page 11 of 21 E-Filed Strength Frequency Range (kHz) Position A (V/m) Position B (V/m) Position C (V/m) Position D (V/m) Position E (V/m) 50% Limit (V/m) Limit Te s t (V/m) 110-205 0.601 0.564 0.631 0.660 0.544 302 604 Note: Test with 15cm distance from the center of the probe(s) to the edge of the device, 20 cm for top test. Result: Compliance Considerations of compliance 680106 D01 RF Exposure Wireless Charging App v03 clause 5 b: (1) Power transfer frequency is less than 1 MHz. Yes, the operation frequency is 110-205 kHz. (2) Output power from each primary coil is less than or equal to 15 watts. Yes, the maximum output power of primary coil is 5 Watts, less than 15 watts. (3) The transfer system includes only single primary and secondary coils. This includes charging systems that may have multiple primary coils and clients that are able to detect and allow coupling only between individual pairs of coils. The transfer system includes only single primary coils to detect and allow coupling only between individual pairs of coils. (4) Client device is placed directly in contact with the transmitter. Yes, client device is placed directly in contact with the transmitter (5) Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion). Yes, mobile exposure conditions only (6) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit. Yes, the test result for H and E-filed strength less than 50% of the MPE limit.

Test Report

Note: This report must not be used by the customer to claim product certification, approval, or endorsement by A2LA* or any agency of the Federal Government. This report may contain data that are not covered by the A2LA accreditation and are marked with an asterisk “★”. BACL is not responsible for the authenticity of any test data provided by the applicant. Data included from the applicant that may affect test results are marked with an asterisk ’*’. Customer model name, addresses, names, trademarks etc. are not considered data. This report cannot be reproduced except in full, without prior written approval of the Company. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. FCC PART 15C TEST REPORT For Ubio Labs, Inc. 2821 Northup Way, Suite 250, Bellevue, WA 98004, USA FCC ID: 2ATGY-PWB1085 Report Type: Original Report Product Type: Power Bank Re port Number: RGMA191225001-00B Re port Date: 2020-01-13 Reviewed B y: Simon Wang RF En gineer Prepared By: Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road, Futian Free Trade Zone, Shenzhen, Guangdong, China Tel: +86-755-33320018 Fax: +86-755-33320008 www.baclcorp.com.cn Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RGMA191225001-00B FCC Part 15C Page 2 of 21 TABLE OF CONTENTS GENERAL INFORMATION ....................................................................................................................................... 3 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .................................................................................... 3 OBJECTIVE ................................................................................................................................................................... 3 RELATED SUBMITTAL(S)/GRANT(S) ............................................................................................................................. 3 TEST METHODOLOGY .................................................................................................................................................. 3 MEASUREMENT UNCERTAINTY .................................................................................................................................... 4 TEST FACILITY ............................................................................................................................................................. 4 SYSTEM TEST CONFIGURATION .......................................................................................................................... 5 JUSTIFICATION ............................................................................................................................................................. 5 EUT EXERCISE SOFTWARE .......................................................................................................................................... 5 SUPPORT EQUIPMENT LIST AND DETAILS .................................................................................................................... 5 EXTERNAL I/O CABLE .................................................................................................................................................. 5 BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................ 6 SUMMARY OF TEST RESULTS ............................................................................................................................... 7 TEST EQUIPMENT LIST ........................................................................................................................................... 8 FCC §1.1310, §2.1091- MAXIMUM PERMISSIBLE EXPOSURE (MPE) ............................................................. 9 APPLICABLE STANDARD .............................................................................................................................................. 9 BLOCK DIAGRAM OF TEST SETUP .............................................................................................................................. 10 TEST DATA ................................................................................................................................................................ 10 FCC§15.203 – ANTENNA REQUIREMENT ........................................................................................................... 12 APPLICABLE STANDARD ............................................................................................................................................ 12 ANTENNA CONNECTED CONSTRUCTION .................................................................................................................... 12 FCC §15.207 – AC LINE CONDUCTED EMISSION ............................................................................................. 13 APPLICABLE STANDARD ............................................................................................................................................ 13 EUT SETUP ................................................................................................................................................................ 13 EMI TEST RECEIVER SETUP ....................................................................................................................................... 13 TEST PROCEDURE ...................................................................................................................................................... 13 CORRECTED FACTOR & MARGIN CALCULATION ....................................................................................................... 14 TEST RESULTS SUMMARY .......................................................................................................................................... 14 TEST DATA .........…

Text truncated - open the document above for the full version.

Test Setup Photos

EXHIBIT D - TEST SETUP PHOTOGRAPHS Conducted Emissions - Front View Conducted Emissions - Side View Radiated Emissions View (9 kHz ~ 30 MHz) Radiated Emissions View (30 MHz ~ 1 GHz) H-Filed Strength View E-Filed Strength View

Contact Information

Applicant

Jesse Li(Compliance Manager)
[email protected]+86 0769-2201 3615Fax: +86 0769-2201 3615

Test Firm

Bay Area Compliance Laboratories Corp. (Shenzhen)Well Wang
[email protected]+86 (0) 755 33320018

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.11 MHz - 0.205 MHz-
Confidentiality
Long Term

Other Applications from UBIO LABS, INC.

Wireless Charging Stand - FCC ID 2ATGY-AWC1109ABV - UBIO LABS, INC.
2ATGY-AWC1109ABV

Wireless Charging Stand

May 31, 2021

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Wireless Charging Pad - FCC ID 2ATGY-AWC1098ABV - UBIO LABS, INC.
2ATGY-AWC1098ABV

Wireless Charging Pad

May 17, 2021

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Power Bank - FCC ID 2ATGY-PWB1085SG - UBIO LABS, INC.
2ATGY-PWB1085SG

Power Bank

Apr 10, 2021

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Wireless Charging Stand - FCC ID 2ATGY-AWC1109 - UBIO LABS, INC.
2ATGY-AWC1109

Wireless Charging Stand

Mar 11, 2021

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Wireless Charging Pad - FCC ID 2ATGY-AWC1098 - UBIO LABS, INC.
2ATGY-AWC1098

Wireless Charging Pad

Feb 23, 2021

Equipment Class