Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Jul 28, 2020
Application Purpose
Original Equipment
Date of Application
Jul 28, 2020
Equipment Note
Wireless Speaker & Charging Hub
Frequency Range
2402.00000000 - 2480.00000000
Company
UBIO LABS, INC.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Bluetooth Speaker Features SAVE THESE INSTRUCTIONS Warranty At Ubio Labs, we are dedicated to designing and manufacturing products with superior performance and 100% customer satisfaction. All of our products come with a 1 year limited warranty from date of purchase. We are always improving our products’ features and functionality. We reserve the right to change product specifications at any time without notice. www.ubiolabs.com [email protected] 1-866-642-4428 (Monday - Friday 9am - 4:30pm PST) 2821 Northup Way, Suite 250 Bellevue, WA 98004 DO NOT RETURN TO THE STORE Our customer service team is here to help. Model: SPK100 / WSP1000 Important Safety Instructions Technical Specifications User Manual and Safety Instructions Component: WSP1000 Input: 9V⎓, 3.0A Output (Wireless): 5W / 7.5W / 10W Charge Indicator: White/amber* LED indicator Frequency Response: 75 Hz–20,000 Hz (-10dB) 110 Hz–20,000 Hz (-3dB) Max Output: 90dB-SPL Signal to Noise Ratio: >80dB Dimensions: 161 x 260 x 140 mm (6.3 x 10.2 x 5.5 in) Weight: 650g (1.43 lbs) Your wireless speaker is designed to provide optimal charging for your wireless device: • 10W Qi certified fast charging for Samsung Galaxy S6 and later, Samsung Note5 and later, Motorola, LG • 7.5W wireless charging for iPhone 8 and later • 5W wireless charging for compatible devices 1 ) Wireless Charge Indicator 2 ) Bluetooth Connectivity LED 3 ) Volume Control 4 ) Play/Pause 5 ) Wireless Charge Surface 6 ) DC Power Input IMPORTANT, RETAIN FOR FUTURE REFERENCE: READ CAREFULLY 312 Technical Specifications Wall Adapter Folding Wall Prongs 6 Ft. Cable Features * A blinking amber LED indicates a foreign object has been detected (metal objects like keys, coins, magnets, etc.) and the device is automatically turned o to ensure safety. Removal of foreign object and proper alignment of phone will result in normal operation. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Caution: The user is cautioned that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et ( 2) l'utilisateur de l'appareil doit accepter tout bro uillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement T he device has been evaluated to meet general RF exposure requirement. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body. L’appareil a été évalué pour répondre aux exigences générales d’exposition aux RF. Cet équipement devrait être installé et acti onné avec la distance minimum 20 cm entre le radiateur et votre corps. T his device is incompatible with the following products: HUAWEI MatePad Pro (MRX-AL09, MRX-AL19) Model: CHG1085 Input: AC 110-240V, 50-60 Hz, 0.7A Output: 27W, DC 9V, 3.0A Dimensions: 58 x 58 x 27 mm (2.3 x 2.3 x 1.1 in) Weight: 95 g (3.3 oz) 4 SPK100 User Manual Material 80G woodfree paper Process: 1c/1c k=100 Bluetooth ® Qi Speaker Stand 5 6

Cover Letter(s)

Ubio Labs,Inc. DATE:2020-07-21 Federal Communications Commission Authorization & Evaluation Division 7345 Oakland Mills Road Columbia, Maryland 21046 Authority to Act asAgent On our behalf, I appoint Shenzhen Zhongjian Nanfang Testing Co.,Ltd.; 1st Floor, Block No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China;Bruce.Zhang, to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the Federal Communications Commission’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, as specified by Ubio Labs,Inc. Dated this 2020-07-21 By: Jason Lemelson Signature Printed Title: manager On behalf of : Ubio Labs,Inc. Telephone: 425-591-9529

Cover Letter(s)

Ubio Labs, Inc. DATE :2020-07-21 Equipment Autorisation Division Federal Communications Commission 7345 Oakland Mills Road Columbia, MD 21046 FCC ID: 2ATGY-WSP1000 Product Name: Wireless Speaker & Charging Hub Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commissions rules, we hereby request that the following documents be held confidential:  Schematics  Block diagram  Operation description  BOM These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. Dated this 2020-07-21 By: Jason Lemelson Signature Printed Title: manager On behalf of : Ubio Labs, Inc. Telephone: 425-591-9529

External Photos

Report No: CCISE200609701 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2006097 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 55 of 68 8 EUT Constructional Details Report No: CCISE200609701 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2006097 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 56 of 68 Report No: CCISE200609701 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2006097 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 57 of 68 Report No: CCISE200609701 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2006097 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 58 of 68 Report No: CCISE200609701 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2006097 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 59 of 68

ID Label/Location Info

WSP1000AW Pantone Cool Gray 4c WSP1000SG

Internal Photos

Report No: CCISE200609701 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2006097 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 60 of 68 Report No: CCISE200609701 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2006097 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 61 of 68 Report No: CCISE200609701 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2006097 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 62 of 68 Report No: CCISE200609701 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2006097 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 63 of 68 Report No: CCISE200609701 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2006097 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 64 of 68 Report No: CCISE200609701 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2006097 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 65 of 68 Report No: CCISE200609701 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2006097 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 66 of 68 Report No: CCISE200609701 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2006097 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 67 of 68 Report No: CCISE200609701 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2006097 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 68 of 68 ------End of report------

RF Exposure Info

Shenzhen Zhongjian Nanfang Testing Co., Ltd. Report No: CCISE200609704 Authorized Signature: Bruce Zhang Laboratory Manager This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other samples of the same product and does not permit the use of the CCIS product certification mark. The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report. This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 1 Cover Page RF Exposure Evaluation Report Applicant: Ubio Labs, Inc. Address of Applicant: 2821 Northup Way, Suite 250 Bellevue, WA 98004 USA Equipment Under Test (EUT) Product Name: Wireless Speaker & Charging Hub Model No.: WSP1000 Trade mark: ubiolabs FCC ID: 2ATGY-WSP1000 Applicable standards: FCC CFR Title 47 Part 2 Subpart J Section 2.1091 Date of sample receipt: 24 Jun., 2020 Date of Test: 24 Jun., to 14 Jul., 2020 Date of report issue: 15 Jul., 2020 Test Result: PASS* Report No: CCISE200609704 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2006097 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 2 of 6 2 Version Version No. Date Description 00 15 Jul., 2020 Original Tested by: Date: 15 Jul., 2020 Test Engineer Reviewed by: Date: 15 Jul., 2020 Project Engineer Report No: CCISE200609704 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2006097 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 3 of 6 3 Contents Page 1 COVER PAGE ....................................................................................................................................................... 1 2 VERSION ............................................................................................................................................................... 2 3 CONTENTS ........................................................................................................................................................... 3 4 GENERAL INFORMATION .................................................................................................................................. 4 4.1 CLIENT INFORMATION ........................................................................................................................................... 4 4.2 GENERAL DESCRIPTION OF E.U.T. ...................................................................................................................... 4 4.3 OPERATING MODES .............................................................................................................................................. 4 4.4 LABORATORY FACILITY ........................................................................................................................................ 4 4.5 LABORATORY LOCATION ...................................................................................................................................... 4 5 TECHNICAL REQUIREMENTS SPECIFICATION IN FCC CFR TITLE 47 PART 2.1091 ............................ 5 5.1 LIMITS .................................................................................................................................................................... 5 5.2 TEST PROCEDURE ................................................................................................................................................. 5 5.3 RESULT .................................................................................................................................................................. 6 5.4 CONCLUSION ......................................................................................................................................................... 6 Report No: CCISE200609704 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2006097 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 4 of 6 4 General Information 4.1 Client Information Applicant: Ubio Labs, Inc. Address: 2821 Northup Way, Suite 250 Bellevue, WA 98004 USA Factory: SHENZHEN JUNLAN ELECTRONIC LTD. Address: No.277 PingKui Road, Shijing Community, Pingshan Street, Pingshan New District, Shenzhen, China. 4.2 General Description of E.U.T. Product Name: Wireless Speaker & Charging Hub Model No.: WSP1000 Operation Frequency: Bluetooth: 2402MHz~2480MHz Modulation technology: Bluetooth BDR: GFSK, Bluetooth EDR: π/4-DQPSK, 8DPSK Antenna Type: Internal Antenna Antenna gain: BT: 0 dBi Test Sample Condition: The test samples were provided in good working order with no visible defects. 4.3 Operating Modes Operating mode Detail description BT mode Keep the EUT in continuously transmitting in BT mode 4.4 Additions to, deviations, or exclusions from the method No 4.5 Laboratory Facility The test facility is recognized, certified, or accredited by the following organizations:  FCC - Designation No.: CN1211 Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been accredited as a testing laboratory by FCC(Federal Co…

Text truncated - open the document above for the full version.

Test Report

Report No: CCISE200609701 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2006097 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 31 of 68 8DPSK Lowest Channel No-hopping mode Hopping mode Highest Channel No-hopping mode Hopping mode Ref 16.5 dBmAtt 20 dB * Offset 6.5 dB A LVL 1.3 MHz/Start2.39 GHzStop2.403 GHz * * 3DB RBW 100 kHz VBW 300 kHz SWT 2.5 ms AC 1 PK MAXH -80 -70 -60 -50 -40 -30 -20 -10 0 10 1 Marker 1 [T1 ] -40.64 dBm 2.400000000 GHz F1 D1 -1.75 dBm D2 -21.75 dBm Date: 7.JUL.2020 15:48:20 Ref 16.5 dBmAtt 20 dB * Offset 6.5 dB A LVL 1.3 MHz/Start2.39 GHzStop2.403 GHz * * 3DB RBW 100 kHz VBW 300 kHz SWT 2.5 ms AC 1 PK MAXH -80 -70 -60 -50 -40 -30 -20 -10 0 10 1 Marker 1 [T1 ] -41.57 dBm 2.400000000 GHz F1 D1 -1.77 dBm D2 -21.77 dBm Date: 7.JUL.2020 15:49:16 Ref 16.5 dBmAtt 20 dB * Offset 6.5 dB A LVL * * 3DB RBW 100 kHz VBW 300 kHz SWT 2.5 ms AC Start2.478 GHzStop2.5 GHz2.2 MHz/ 1 PK MAXH -80 -70 -60 -50 -40 -30 -20 -10 0 10 1 Marker 1 [T1 ] -52.76 dBm 2.486624000 GHz F1 D1 -3.13 dBm D2 -23.13 dBm Date: 7.JUL.2020 15:54:40 Ref 16.5 dBmAtt 20 dB * Offset 6.5 dB A LVL * * 3DB RBW 100 kHz VBW 300 kHz SWT 2.5 ms AC Start2.478 GHzStop2.5 GHz2.2 MHz/ 1 PK MAXH -80 -70 -60 -50 -40 -30 -20 -10 0 10 1 Marker 1 [T1 ] -47.36 dBm 2.499912000 GHz F1 D1 -3.39 dBm D2 -23.39 dBm Date: 7.JUL.2020 15:55:30 Report No: CCISE200609701 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2006097 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 32 of 68 6.9.2 Radiated Emission Method Test Requirement: FCC Part 15 C Section 15.209 and 15.205 Test Frequency Range: 2310 MHz to 2390 MHz and 2483.5 MHz to 2500 MHz Test Distance: 3m Receiver setup: Frequency Detector RBW VBW Remark Above 1GHz Peak 1MHz 3MHz Peak Value RMS 1MHz 3MHz Average Value Limit: Frequency Limit (dBuV/m @3m) Remark Above 1GHz 54.00 Average Value 74.00 Peak Value Test setup: Test Procedure: 1. The EUT was placed on the top of a rotating table 1.5meters above the ground at a 3 meter camber. The table was rotated 360 degrees to determine the position of the highest radiation. 2. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top of a variable-height antenna tower. 3. The antenna height is varied from one meter to four meters above the ground to determine the maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set to make the measurement. 4. For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to heights from 1 meter to 4 meters and the rota table was turned from 0 degrees to 360 degrees to find the maximum reading. 5. The test-receiver system was set to Peak Detect Function and Specified Bandwidth with Maximum Hold Mode. 6. If the emission level of the EUT in peak mode was 10dB lower than the limit specified, then testing could be stopped and the peak values of the EUT would be reported. Otherwise the emissions that did not have 10dB margin would be re-tested one by one using peak, quasi-peak or average method as specified and then reported in a data sheet. Test Instruments: Refer to section 5.9 for details Test mode: Non-hopping mode Test results: Passed Report No: CCISE200609701 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2006097 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 33 of 68 GFSK Mode: Product Name: Wireless Speaker & Charging Hub Product Model: WSP1000 Test By: Mike Test mode: DH1 Tx mode Test Channel: Lowest channel Polarization: Vertical Test Voltage: AC 120V/60Hz Environment: Temp: 24°C Huni: 57% Remark: 1.Final Level = Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor. 2.The emission levels of other frequencies are lower than the limit 20dB and not show in test report. Report No: CCISE200609701 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2006097 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 34 of 68 Product Name: Wireless Speaker & Charging Hub Product Model: WSP1000 Test By: Mike Test mode: DH1 Tx mode Test Channel: Lowest channel Polarization: Horizontal Test Voltage: AC 120V/60Hz Environment: Temp: 24°C Huni: 57% Remark: 1.Final Level = Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor. 2.The emission levels of other frequencies are lower than the limit 20dB and not show in test report. Report No: CCISE200609701 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2006097 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 35 of 68 Product Name: Wireless Speaker & Charging Hub Product Model: WSP1000 Test By: Mike Test mode: DH1 Tx mode Test Channel: Highest channel Polarization: Vertical Test Voltage: AC 120V/60Hz Environment: Temp: 24°C Huni: 57% Remark: 1.Final Level = Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor. 2.The emission levels of other frequencies are lower than the limit 20dB and not show in test report. Report No: CCISE200609701 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2006097 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 36 of 68 Product Name: Wireless Speaker & Charging Hub Product Model: WSP1000 Test By: Mike Test mode: DH1 Tx mode Test Channel: Highest channel Polariza…

Text truncated - open the document above for the full version.

Test Report

Shenzhen Zhongjian Nanfang Testing Co., Ltd. Report No: CCISE200609701 Authorized Signature: Bruce Zhang Laboratory Manager This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other samples of the same product and does not permit the use of the CCIS product certification mark. The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report. This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 1 Cover Page FCC REPORT (Bluetooth) Applicant: Ubio Labs, Inc. Address of Applicant: 2821 Northup Way, Suite 250 Bellevue, WA 98004 USA Equipment Under Test (EUT) Product Name: Wireless Speaker & Charging Hub Model No.: WSP1000 Trade mark: ubiolabs FCC ID: 2ATGY-WSP1000 Applicable standards: FCC CFR Title 47 Part 15 Subpart C Section 15.247 Date of sample receipt: 24 Jun., 2020 Date of Test: 24 Jun., to 14 Jul., 2020 Date of report issued: 15 Jul., 2020 Test Result: PASS * * In the configuration tested, the EUT complied with the standards specified above. Report No: CCISE200609701V01 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2006097 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 2 of 68 2 Version Version No. Date Description 00 15 Jul., 2020 Original 01 03 Aug., 2020 Update page 6 Tested by: Date: 03 Aug., 2020 Test Engineer Reviewed by: Date: 03 Aug., 2020 Project Engineer Report No: CCISE200609701 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2006097 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 3 of 68 3 Contents Page 1 COVER PAGE ............................................................................................................................................................. 1 2 VERSION ..................................................................................................................................................................... 2 3 CONTENTS ................................................................................................................................................................. 3 4 TEST SUMMARY ........................................................................................................................................................ 4 5 GENERAL INFORMATION ........................................................................................................................................ 5 5.1 CLIENT INFORMATION ....................................................................................................................................... 5 5.2 GENERAL DESCRIPTION OF E.U.T. ................................................................................................................... 5 5.3 TEST ENVIRONMENT AND TEST MODE ................................................................................................................ 6 5.4 DESCRIPTION OF SUPPORT UNITS .................................................................................................................... 6 5.5 MEASUREMENT UNCERTAINTY .......................................................................................................................... 6 5.6 ADDITIONS TO, DEVIATIONS, OR EXCLUSIONS FROM THE METHOD ....................................................................... 6 5.7 LABORATORY FACILITY ..................................................................................................................................... 6 5.8 LABORATORY LOCATION ................................................................................................................................... 6 5.9 TEST INSTRUMENTS LIST .................................................................................................................................. 7 6 TEST RESULTS AND MEASUREMENT DATA ...................................................................................................... 8 6.1 ANTENNA REQUIREMENT .................................................................................................................................. 8 6.2 CONDUCTED EMISSIONS .................................................................................................................................. 9 6.3 CONDUCTED OUTPUT POWER ........................................................................................................................ 12 6.4 20DB OCCUPY BANDWIDTH ............................................................................................................................ 15 6.5 CARRIER FREQUENCIES SEPARATION ............................................................................................................. 18 6.6 HOPPING CHANNEL NUMBER .......................................................................................................................... 22 6.7 DWELL TIME .................................................................................................................................................. 24 6.8 PSEUDORANDOM FREQUENCY HOPPING SEQUENCE.........…

Text truncated - open the document above for the full version.

Test Setup Photos

Report No: CCISE200609701 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2006097 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 53 of 68 7 Test Setup Photo Radiated Spurious Emission Below 1GHz Above 1GHz Report No: CCISE200609701 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2006097 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 54 of 68 Conducted Emission

Contact Information

Applicant

Jesse Li(Compliance Manager)
[email protected]+86 0769-2201 3615Fax: +86 0769-2201 3615

Test Firm

JianYan Testing Group Shenzhen Co., Ltd.Bruce Zhang
[email protected]+86 (0) 755 23118282

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz759.00 µW
Confidentiality
Long Term
Grant Notes
Power output listed is conducted

Other Applications from UBIO LABS, INC.

Wireless Charging Stand - FCC ID 2ATGY-AWC1109ABV - UBIO LABS, INC.
2ATGY-AWC1109ABV

Wireless Charging Stand

May 31, 2021

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Wireless Charging Pad - FCC ID 2ATGY-AWC1098ABV - UBIO LABS, INC.
2ATGY-AWC1098ABV

Wireless Charging Pad

May 17, 2021

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Power Bank - FCC ID 2ATGY-PWB1085SG - UBIO LABS, INC.
2ATGY-PWB1085SG

Power Bank

Apr 10, 2021

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Wireless Charging Stand - FCC ID 2ATGY-AWC1109 - UBIO LABS, INC.
2ATGY-AWC1109

Wireless Charging Stand

Mar 11, 2021

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Wireless Charging Pad - FCC ID 2ATGY-AWC1098 - UBIO LABS, INC.
2ATGY-AWC1098

Wireless Charging Pad

Feb 23, 2021

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz