  3. 2ATHV-DRC10

2ATHV-DRC10Tray-Style Transmitter

SHENZHEN DUMBO MODEL CO., LTD.

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Mar 26, 2026
Application Purpose
Original Equipment
Equipment Note
Tray-Style Transmitter
Frequency Range
2402.00000000 - 2481.20000000
Company
SHENZHEN DUMBO MODEL CO., LTD.
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

AttestationStatementLetterI FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Date:2026.3.25 Ref:AttestationStatementsPart2.911(d)(5)(i)Filing FCCApplicationforFCCID:2ATHV-DRC10 SHENZHENDUMBOMODELCO.,LTD.certifiesthattheequipmentforwhichauthorization issoughtisnot“covered”equipmentprohibitedforreceivinganequipmentauthorization pursuanttosection2.903oftheFCCrules. Sincerely, Applicant’sSignature: Applicant’sName:LeiyuFang

Attestation Statements

AttestationStatementLetterII FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:2026.3.25 Ref:AttestationStatementsPart2.911(d)(5)(ii)Filing FCCApplicationforFCCID:2ATHV-DRC10 SHENZHENDUMBOMODELCO.,LTD.certifiesthat,asofthedateofthefilingofthe application,theapplicantisnotidentifiedontheCoveredListasanentityproducing “covered”equipment. Sincerely, Applicant’sSignature: Applicant’sName:LeiyuFang

Cover Letter(s)

FederalCommunicationsCommission AuthorizationandEvaluationDivision ConfidentialityRequestregardingapplicationforcertificationofFCCID:2ATHV-DRC10 PursuanttoSections0.457and0.459oftheCommission’sRules,weherebyrequest confidentialtreatmentofinformationaccompanyingthisapplicationasoutlinedbelow: TypeofConfidentialityRequestedExhibitType ☐ShortTerm ☒PermanentBlockDiagrams ☒ShortTermExternalPhotos ☒ShortTerm☐Permanent*InternalPhotos ☐ShortTerm ☒PermanentOperationDescription ☐ShortTerm ☒PermanentSchematics ☒ShortTermTestSetupPhotos ☒ShortTerm☐Permanent*Usermanual *Requiresfurtherjustificationbeforepermanentconfidentialitywillbeallowed. Theabovematerialscontaintradesecretsandproprietaryinformationnotcustomarily releasedtothepublic.Thepublicdisclosureofthesematerialsmaybeharmfultothe applicantandprovideunjustifiedbenefitstoitscompetitors. PermanentConfidentiality: Theapplicantrequeststheexhibitslistedaboveaspermanentlyconfidentialbewithheld frompublicreviewduetomaterialsthatcontaintradesecretsandproprietaryinformation notcustomarilyreleasedtothepublic. Short-TermConfidentiality: PursuanttoDA04-1705June15,2004oftheCommission’spublicnotice,wealsorequest temporaryconfidentialtreatmentofinformationaccompanyingthisapplicationasoutlined belowforaninitialperiodof180days. Sincerely, Client’ssignature: Client’sname&title:LeiyuFang&GeneralManager Contactinformation/address:C301,KedasiIndustrialPark,No.42,Xinzhang Rd.,GuanhuStreet,LonghuaDistrict,Shenzhen,Guangdong,China

Cover Letter(s)

FCCAgentAuthorizationLetter FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Date:_2026.3.25_ SUBJECT:FCCApplicationforFCCID:2ATHV-DRC10 ToWhomItMayConcern: We,theundersigned,herebyauthorizeKevinWuinShenzhenNCTTestingTechnologyCo., Ltd.onourbehalf,toapplytotheFederalCommunicationsCommissionforourequipment. AnyandallactscarriedoutbyShenzhenNCTTestingTechnologyCo.,Ltd.onourbehalf shallhavethesameeffectasactsofourown. ThisistoadvisethatweareinfullcompliancewiththeAnti-DrugAbuseAct.We,the applicant,arenotsubjecttoadenialoffederalbenefitspursuanttoSection5301ofthe Anti-DrugActof1988,21USC853a,andnopartytotheapplicationissubjecttoadenialof federalbenefitspursuanttothatsection. Sincerely, Client’ssignature: Client’sname&title:LeiyuFang&GeneralManager Contactinformation/address:C301,KedasiIndustrialPark,No.42,XinzhangRd.,Guanhu Street,LonghuaDistrict,Shenzhen,Guangdong,China

Cover Letter(s)

SHENZHEN DUMBO MODEL CO., LTD. Product Similarity Declaration Product name: Tray-Style Transmitter Model name: DRC10, DRC6 FCC ID: 2ATHV-DRC10 We (SHENZHEN DUMBO MODEL CO., LTD.) hereby state that all the models are electrical identical including the same software parameter and hardware design (i.e., circuit design, PCB Layout, RF module/circuit, antenna type(s) and antenna location, components on PCB, etc.,), same mechanical structure and design (including product enclosure, materials, etc.,), the only difference is the model name and outlook (Stickers vary by model). Signature: Name: Leiyu Fang Title: General Manager Place, date: Shenzhen, 2026.1.14

ID Label/Location Info

Label: Size: 25mm*83mm Label & Location: Label & Location

RF Exposure Info

FCC ID:2ATHV-DRC10 RF Exposure Evaluation According to KDB 447498 D01 General RF Exposure Guidance v06 and part 2.1093, Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition(s), listed below, is (are) satisfied. For 100 MHz to 6 GHz and test separation distances ≤ 5.0 mm, the 1-g and 10-g SAR test exclusion thresholds are determined by the following: [(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)] · [√f (GHz) ] ≤ 3.0 for 1-g SAR, and ≤ 7.5 for 10-g extremity SAR, where f (GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation The result is rounded to one decimal place for comparison Here, So a SAR test is not required Mode Freque ncy (MHz) Max Power (dBm) Target power W/ tolerance (dBm) Max tune up power tolerance (dBm) Max Power (mW) Min. Distanc e (mm) Calc. threshol ds limit GFSK 2402 2.58 2±1 3 1.9953 5.00 0.6185 3.0 2441.6 1.53 2±1 3 1.9953 5.00 0.6235 3.0 2481.2 1.41 2±1 3 1.9953 5.00 0.6286 3.0

Test Report

Page 1 of 35 Hotline: 400-8868-419 http://www.ncttesting.cn FCC TEST REPORT FCC ID: 2ATHV-DRC10 Product : Tray-Style Transmitter Model Name : DRC10, DRC6 Brand : N/A Report No. : NCT260031040XE1-1 Prepared for SHENZHEN DUMBO MODEL CO., LTD. C301, Kedasi Industrial Park, No. 42, Xinzhang Rd., Guanhu Street, Longhua District, Shenzhen, Guangdong, China Prepared by Shenzhen NCT Testing Technology Co., Ltd. A101&2F B2, Fuqiao 6th Area, Xintian Community, Fuhai Street, Baoan District, Shenzhen, People’s Republic of China TEL: 400-8868-419 Report No.: NCT260031040XE1-1 Page 2 of 35 Hotline: 400-8868-419 http://www.ncttesting.cn 1 TEST RESULT CERTIFICATION Applicant’s name : SHENZHEN DUMBO MODEL CO., LTD. Address : C301, Kedasi Industrial Park, No. 42, Xinzhang Rd., Guanhu Street, Longhua District, Shenzhen, Guangdong, China Manufacture's name : SHENZHEN DUMBO MODEL CO., LTD. Address : C301, Kedasi Industrial Park, No. 42, Xinzhang Rd., Guanhu Street, Longhua District, Shenzhen, Guangdong, China Product name : Tray-Style Transmitter Model name : DRC10 Additional model : DRC6 Standards : FCC CFR47 Part 15 Section 15.247 Test procedure Test Date Date of Issue : ANSI C63.10:2020 : Jan. 10, 2026 to Mar. 26, 2026 : Mar. 26, 2026 Test Result :Pass This device described above has been tested by NCT, and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of NCT, this document may be altered or revised by NCT, personal only, and shall be noted in the revision of the document. Test Engineer: Keven Wu / Engineer Technical Manager: Henry Wang / Manager Report No.: NCT260031040XE1-1 Page 3 of 35 Hotline: 400-8868-419 http://www.ncttesting.cn Contents Page 1 TEST RESULT CERTIFICATION .............................................................................................................................. 2 2 TEST SUMMARY ......................................................................................................................................................... 5 3 TEST FACILITY ............................................................................................................................................................ 6 4 GENERAL INFORMATION ........................................................................................................................................ 7 4.1 GENERAL DESCRIPTION OF E.U.T. .................................................................................................................... 7 4.2 CHANNEL LIST .................................................................................................................................................... 8 4.3 TEST SETUP CONFIGURATION ........................................................................................................................... 9 4.4 TEST CONFIGURATION ........................................................................................................................................ 9 5 EQUIPMENT DURING TEST ................................................................................................................................... 10 5.1 EQUIPMENTS LIST ............................................................................................................................................ 10 5.2 MEASUREMENT UNCERTAINTY ......................................................................................................................... 12 5.3 DESCRIPTION OF SUPPORT UNITS ................................................................................................................... 12 6 CONDUCTED EMISSION ......................................................................................................................................... 13 6.1 E.U.T. OPERATION ........................................................................................................................................... 13 6.2 EUT SETUP ...................................................................................................................................................... 13 6.3 TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION) .................................................................................. 14 6.4 MEASUREMENT PROCEDURE: .......................................................................................................................... 14 6.5 CONDUCTED EMISSION LIMIT ........................................................................................................................... 14 6.6 MEASUREMENT DESCRIPTION .......................................................................................................................... 14 6.7 CONDUCTED EMISSION TEST RESULT ............................................................................................................. 14 7 RADIATED SPURIOUS EMISSIONS ..................................................................................................................... 17 7.1 EUT OPERATION .............................................................................................................................................. 17 7.2 TEST SETUP ..................................................................................................................................................... 18 7.3 SPECTRUM ANALYZER SETUP .......................................................................................................................... 19 7.4 TEST PROCEDURE ............................................................................................................................................ 20 7.5 SUMMARY OF TEST RESULTS .......................................................................................................................... 21 8 MAXIM…

Text truncated - open the document above for the full version.

Test Report

深圳市铄点电子科技有限公司 ShenzhenShuodianElectronicTechnologyCo.,Ltd Pagenumber1-11 规格书 for 2.4G铜管天线(D809-2001) 客户料号 本公司料号 XFX-2.4G铜管天线(D809-2001)-138MM 编制:曾小凤审核:李明 日期:2025.10.11 深圳市铄点电子科技有限公司 广东省深圳市光明区凤凰街道塘尾社区南太云创谷园区2栋201 邮箱:[email protected] 电话:0755-86006322 传真:0755-86006323 ShenzhenShuodianElectronicTechnologyCo.,Ltd Date:2014-6-30Page number2-8 深圳市铄点电子科技有限公司 ShenzhenShuodianElectronicTechnologyCo.,Ltd Pagenumber2-10 目录 规格书....................................................................................................................................1 深圳市铄点电子科技有限公司................................................................................................1 目录............................................................................................................................................2 1.双方确认.................................................................................................................................3 2.一般事项.................................................................................................................................4 3.产品一般规格.........................................................................................................................4 4.产品规格明细.........................................................................................................................5 4.1产品结构参数......................................................................................................................5 4.2产品电性能测试数据.........................................................................................................7 5.产品包装方式.......................................................................................................................9 6.文档履历.............................................................................................................................10 ShenzhenShuodianElectronicTechnologyCo.,Ltd Date:2014-6-30Page number3-8 深圳市铄点电子科技有限公司 ShenzhenShuodianElectronicTechnologyCo.,Ltd Pagenumber3-10 1.双方确认 1.1客户确认签字 客户: 客户部门/职位确认人签字确认日期 硬件/射频 结构 项目经理 商务/采购 审核 1.2 铄点科技确认签字 部门/职位确认人签字确认日期 天线工程师 结构工程师 项目经理 QA 审核 ShenzhenShuodianElectronicTechnologyCo.,Ltd Date:2014-6-30Page number4-8 深圳市铄点电子科技有限公司 ShenzhenShuodianElectronicTechnologyCo.,Ltd Pagenumber4-10 2.一般事项 2.1适用范围 本规格书只适用于2.4G铜管天线(D809-2001) 2.2使用温度范围 本产品使用温度范围-20~+65°C 2.3 保存温度范围 本产品保存于-30~+75°C 3.产品一般规格 NO . ITEMSDETAILS 1机型 2.4G 铜管天线 (D809-2001) 2频段2400-2500MHz 3驻波VSWR≤3.0; 4阻抗50Ω 5天线类型单极 6天线实现形式同轴线+铜管 7天线图片 ShenzhenShuodianElectronicTechnologyCo.,Ltd Date:2014-6-30Page number5-8 深圳市铄点电子科技有限公司 ShenzhenShuodianElectronicTechnologyCo.,Ltd Pagenumber5-10 4.产品规格明细 4.1产品结构参数 4.11 产品物料组成: 序号材料规格(MM) 1黄铜管Φ5.2*25本色 2同轴线Φ1.13L=138白色 4.12外观 产品外观良好,无伤痕、汗迹、突起等严重影响外观缺陷。 4.13结构尺寸 产品图纸: ShenzhenShuodianElectronicTechnologyCo.,Ltd Date:2014-6-30Page number6-8 深圳市铄点电子科技有限公司 ShenzhenShuodianElectronicTechnologyCo.,Ltd Pagenumber6-10 ShenzhenShuodianElectronicTechnologyCo.,Ltd Date:2014-6-30Page number7-8 深圳市铄点电子科技有限公司 ShenzhenShuodianElectronicTechnologyCo.,Ltd Pagenumber7-10 4.2 产品电性能测试数据 4.21测试环境及仪器设备 测试环境: 温度:10°C——+30°C 相对湿度:≤80%(+40°C) 大气压力:750mmkg±30mmkg 测试设备: 网络分析仪 KEYSIGHTE5071C 多探头全电波暗室 4.22产品电性能测试数据: 4.22.1产品的S11图: 大尺寸S11数据: Marker(MHz)240024502500 ReturnLoss-9.18-11.94-12.95 VSWR2.081.691.57 ShenzhenShuodianElectronicTechnologyCo.,Ltd Date:2014-6-30Page number8-8 深圳市铄点电子科技有限公司 ShenzhenShuodianElectronicTechnologyCo.,Ltd Pagenumber8-10 大尺寸增益、效率及辐射方向图 频率( MHz ) 24002410242024302440245024602470248024902500 Gain ( dBi ) 1.641.531.491.671.982.192.392.632.602.802.82 Efficency(%) 48.4349.2849.6951.5454.4156.4258.4961.4860.8862.1360.06 ShenzhenShuodianElectronicTechnologyCo.,Ltd Date:2014-6-30Page number9-8 深圳市铄点电子科技有限公司 ShenzhenShuodianElectronicTechnologyCo.,Ltd Pagenumber9-10 5.产品包装方式 包装方式: 自封袋包装,每包200PCS。 ShenzhenShuodianElectronicTechnologyCo.,Ltd Date:2014-6-30Page number10-8 深圳市铄点电子科技有限公司 ShenzhenShuodianElectronicTechnologyCo.,Ltd Pagenumber10-10 6.文档履历 文件编号 DocumentNo. 日期 ReleaseDate 2025/10/11 编制 Author Hungjie 复核 Review WH 文件历次表 RevisedHistory DateVersionRevisedRecord 2025/10/111.00NewProject

Test Report

1 / 29 FCC ID (Part15.247) Test Data Report No.: NCT260031040XE1-1 FCC ID: 2ATHV-DRC10 Table of Contents Maximum Conducted Output Power ............................................................................................................................................................. 2 -20dB Bandwidth ........................................................................................................................................................................................... 5 Occupied Channel Bandwidth....................................................................................................................................................................... 8 Carrier Frequencies Separation .................................................................................................................................................................. 11 Number of Hopping Channel ...................................................................................................................................................................... 14 Dwell Time .................................................................................................................................................................................................. 16 Band Edge .................................................................................................................................................................................................. 20 Band Edge(Hopping) .................................................................................................................................................................................. 23 Conducted RF Spurious Emission .............................................................................................................................................................. 26 2 / 29 Maximum Conducted Output Power Condition Mode Frequency (MHz) Antenna Conducted Power (dBm) Duty Factor (dB) Total Power (dBm) Limit (dBm) Verdict NVNT GFSK 2402 Ant1 2.58 0 2.58 21 Pass 2441.6 1.53 0 1.53 21 Pass 2481.2 1.41 0 1.41 21 Pass 3 / 29 Test Graphs Power NVNT GFSK 2402MHz Ant1 Power NVNT GFSK 2441.6MHz Ant1 4 / 29 Power NVNT GFSK 2481.2MHz Ant1 5 / 29 -20dB Bandwidth Condition Mode Frequency (MHz) Antenna -20 dB Bandwidth (MHz) Limit -20 dB Bandwidth (MHz) Verdict NVNT GFSK 2402 Ant1 0.119 0 Pass 2441.6 0.117 0 Pass 2481.2 0.119 0 Pass 6 / 29 Test Graphs -20dB Bandwidth NVNT GFSK 2402MHz Ant1 -20dB Bandwidth NVNT GFSK 2441.6MHz Ant1 7 / 29 -20dB Bandwidth NVNT GFSK 2481.2MHz Ant1 8 / 29 Occupied Channel Bandwidth Condition Mode Frequency (MHz) Antenna 99% OBW (MHz) NVNT GFSK 2402.0 Ant1 0.124 2441.6 0.116 2481.2 0.117 9 / 29 Test Graphs OBW NVNT GFSK 2402MHz Ant1 OBW NVNT GFSK 2441.6MHz Ant1 10 / 29 OBW NVNT GFSK 2481.2MHz Ant1 11 / 29 Carrier Frequencies Separation Condition Mode Antenna Hopping Freq1 (MHz) Hopping Freq2 (MHz) HFS (MHz) Limit (MHz) Verdict NVNT GFSK Ant1 2402.0368 2403.238 1.2012 0.079 Pass 2441.6258 2442.8314 1.2056 0.078 Pass 2480.0192 2481.2204 1.2716 0.079 Pass 12 / 29 Test Graphs CFS NVNT GFSK 2402MHz Ant1 CFS NVNT GFSK 2441.6MHz Ant1 13 / 29 CFS NVNT GFSK 2481.2MHz Ant1 14 / 29 Number of Hopping Channel Condition Mode Antenna Hopping Number Limit Verdict NVNT GFSK Ant1 67 15 Pass 15 / 29 Test Graphs Hopping No. NVNT Ant1 16 / 29 Dwell Time Condition Mode Frequency (MHz) Antenna Pulse Time (ms) Total Dwell Time (ms) Burst Count Period Time (ms) Limit (ms) Verdict NVNT GFSK 2402 Ant1 9.302 213.946 23 26800 400 Pass 2441.6 9.299 195.279 21 26800 400 Pass 2481.2 9.302 120.926 13 26800 400 Pass 17 / 29 Test Graphs Dwell NVNT GFSK 2402MHz Ant1 One Burst Dwell NVNT GFSK 2402MHz Ant1 Accumulated 18 / 29 Dwell NVNT GFSK 2441.6MHz Ant1 One Burst Dwell NVNT GFSK 2441.6MHz Ant1 Accumulated 19 / 29 Dwell NVNT GFSK 2481.2MHz Ant1 One Burst Dwell NVNT GFSK 2481.2MHz Ant1 Accumulated 20 / 29 Band Edge Condition Mode Frequency (MHz) Antenna Hopping Mode Max Value (dBc) Limit (dBc) Verdict NVNT GFSK 2402 Ant1 No-Hopping -38.53 -20 Pass 2481.2 No-Hopping -46.37 -20 Pass 21 / 29 Test Graphs Band Edge NVNT GFSK 2402MHz Ant1 No-Hopping Ref Band Edge NVNT GFSK 2402MHz Ant1 No-Hopping Emission 22 / 29 Band Edge NVNT GFSK 2481.2MHz Ant1 No-Hopping Ref Band Edge NVNT GFSK 2481.2MHz Ant1 No-Hopping Emission 23 / 29 Band Edge(Hopping) Condition Mode Frequency (MHz) Antenna Hopping Mode Max Value (dBc) Limit (dBc) Verdict NVNT GFSK 2402 Ant1 Hopping -40.89 -20 Pass 2481.2 Hopping -48.13 -20 Pass 24 / 29 Test Graphs Band Edge(Hopping) NVNT GFSK 2402MHz Ant1 Hopping Ref Band Edge(Hopping) NVNT GFSK 2402MHz Ant1 Hopping Emission 25 / 29 Band Edge(Hopping) NVNT GFSK 2481.2MHz Ant1 Hopping Ref Band Edge(Hopping) NVNT GFSK 2481.2MHz Ant1 Hopping Emission 26 / 29 Conducted RF Spurious Emission Condition Mode Frequency (MHz) Antenna Max Value (dBc) Limit (dBc) Verdict NVNT GFSK 2402 Ant1 -46.83 -20 Pass 2441.6 -46.79 -20 Pass 2481.2 -45.94 -20 Pass 27 / 29 Test Graphs Tx. Spurious NVNT GFSK 2402MHz Ant1 Ref Tx. Spurious NVNT GFSK 2402MHz Ant1 Emission 28 / 29 Tx. Spurious NVNT GFSK 2441.6MHz Ant1 Ref Tx. Spurious NVNT GFSK 2441.6MHz Ant1 Emission 29 / 29 Tx. Spurious NVNT GFSK 2481.2MHz Ant1 Ref Tx. Spurious NVNT GFSK 2481.2MHz Ant1 Emission

Contact Information

Applicant

Leiyu Fang(General Manager)
[email protected]Fax: +86-0755-27618355

Technical Contact

UUX GROUP INCJack Fu
[email protected]

1312 17th Street #692 · Denver, Colorado, 80202 · United States

Test Firm

SHENZHEN NCT TESTING TECHNOLOGY CO., LTD.Henry Wang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.81 mW
Confidentiality
Long Term
Grant Notes
Power output listed is the maximum conducted power.

Other Applications from SHENZHEN DUMBO MODEL CO., LTD.

2ATHV-DRCRF

RF Module

Apr 20, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
2ATHV-DRC16P

Tray-Style Transmitter

Mar 31, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
2ATHV-DRC10P

Tray-Style Transmitter

Mar 31, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Pistol Grip Transmitter - FCC ID 2ATHV-CR10S - SHENZHEN DUMBO MODEL CO., LTD.
2ATHV-CR10S

Pistol Grip Transmitter

Jan 27, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Pistol Grip Transmitter - FCC ID 2ATHVDDF-350 - SHENZHEN DUMBO MODEL CO., LTD.
2ATHVDDF-350

Pistol Grip Transmitter

Dec 01, 2023

Equipment Class