FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Level Home Inc./
  3. 2ATIO2

2ATIO2Level lock

Level Home Inc.

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Apr 16, 2020
Application Purpose
Original Equipment
Date of Application
Apr 16, 2020
Equipment Note
Level lock
Frequency Range
2402.00000000 - 2480.00000000
Company
Level Home Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

Attestation Statements

↗

Cover Letter(s)

↗

External Photos

ID Label/Location Info

Internal Photos

RF Exposure Info

Test Report

↗

Test Setup Photos

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Level Home Inc. 935 Main St Redwood City, CA 94063, United States Attestation Date: 2022-12-19 We Name: Level Home Inc. Address: 935 Main St Redwood City, CA 94063, United States City: Redwood City Country: United States Declare that: Product description: Level lock FCC ID: 2ATIO2 no units without NFC functionality have been sold. Sincerely, Christopher Johnston / VP Operations Level Home Inc.

Cover Letter(s)

Declaration Of Authorization Date: 2020-03-30 We Name: Level Home Inc Address: 935 Main St Redwood City, CA 94063, United States City: Redwood City Country: United States Declare that: Agent Company name: DEKRA Testing and Certification (Suzhou) Co., Ltd. Address: No.99 Hongye Rd., Suzhou Industrial Park , 215006 City: Suzhou Country China is authorized to apply for Certification of the following product(s): Product description: Level lock Type designation: B1 FCC ID: 2ATIO2 on our behalf. Sincerely, Christopher Johnston / VP Operations Level Home Inc Notes: (1): Required for FCC application (2): For it must be the Grantee Code “owner” or the authorized agent.

Test Report

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 Test report No: 2032061R-RF-US-P06V01 FCC TEST REPORT Product Name Level lock Trademark Model and /or type reference B1, B2, B3, B4 FCC ID 2ATIO2 Applicant ́s name / address Level Home Inc 935 Main St Redwood City, CA 94063 Test method requested, standard FCC CFR Title 47 Part 15 Subpart C Section 15.247 ANSI C63.10: 2013 KDB 558074 D01 15.247 Meas Guidance v05r02 RSS-Gen Issue 5 / RSS-247 Issue 2 Verdict Summary IN COMPLIANCE Documented By Tim Cao/Project Engineer Approved by (name / position & signature) Jack Zhang/ Supervisor Date of issue 2022-11-28 Report template No 2032061R-RF-US-P06V01 DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 Report no.: 2032061R-RF-US-P06V01 Page 2 / 93 INDEX page General conditions ...................................................................................................................................................... 4 Environmental conditions ............................................................................................................................................ 4 Possible test case verdicts .......................................................................................................................................... 5 Abbreviations .............................................................................................................................................................. 5 Document History ....................................................................................................................................................... 6 Remarks and Comments ............................................................................................................................................. 6 Used Equipment ......................................................................................................................................................... 7 Uncertainty ................................................................................................................................................................. 8 1 General Information............................................................................................................................................ 9 1.1 General Description of the Item(s) ............................................................................................................ 9 1.2 Antenna Information ............................................................................................................................... 10 1.3 Channel List ........................................................................................................................................... 10 2 Description of Test Setup ................................................................................................................................. 11 2.1 Operating mode(s) used for tests ............................................................................................................ 11 2.2 Auxiliary equipment / Test software for the EUT ...................................................................................... 11 2.3 Test Configuration / Block diagram used for tests ................................................................................... 12 2.4 Testing process ...................................................................................................................................... 13 3 Verdict summary section .................................................................................................................................. 14 3.1 Standards............................................................................................................................................... 14 3.2 Deviation(s) from the Standard(s) / Test Specification(s) ......................................................................... 14 3.3 Overview of results ................................................................................................................................. 14 3.4 Test Facility ............................................................................................................................................ 15 4 Test Results ..................................................................................................................................................... 16 4.1 AC Power Line Conducted Emission ...................................................................................................... 16 4.1.1 Limit ............................................................................................................................................. 16 4.1.2 Test Setup .................................................................................................................................... 16 4.1.3 Test Procedure ............................................................................................................................. 16 4.1.4 Test Data ..................................................................................................................................... 17 4.2 Emissions in restricted frequency bands ................................................................................................. 18 4.2.1 Limit ............................................................................................................................................. 18 4.2.2 Test Setup .................................................................................................................................... 20 4.2.3 Test Procedure .........................................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Mathias Bitz(Director of Supply Chain)
[email protected]4084258092Fax: 415 919 8555

Technical Contact

DEKRA Testing and Certification (Suzhou) Co.,Jack Zhang
[email protected]86-0512-6251-5088

No.99 Hongye RD.Suzhou Industrial Park, · Suzhou · China

Non-Technical Contact

DEKRA Testing and Certification (Suzhou) Co.,Rachel Hua
[email protected]86-0512-6251-5088

Test Firm

DEKRA Testing and Certification (Suzhou) Co., Ltd.Janet Xu
[email protected]86 512 6251 50885113

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.50 mW
Confidentiality
Long Term
Grant Notes
Power Output listed is conducted. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Level Home Inc.

Home IOT Gateway - FCC ID 2ATIO4 - Level Home Inc.
2ATIO4

Home IOT Gateway

Apr 13, 2023

Equipment Class

PCB - PCS Licensed Transmitter