2ATTE2162100005RFID Reader

DUERR DENTAL SE
RFID Reader - FCC ID 2ATTE2162100005 - DUERR DENTAL SE
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Jan 19, 2023
Application Purpose
Original Equipment
Date of Application
Jan 19, 2023
Equipment Note
RFID Reader
Frequency Range
13.56000000 - 13.56000000
Company
DUERR DENTAL SE
Country
Germany

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

ScanX Smart Reader ULR01.1A1 EN-US Installation and Operating Instructions 2162100017L29 G8803 V003 Contents Important information 1About this document . . . . . . . . . . . . . . 2 1.1Warnings and symbols . . . . . . . .2 1.2Copyright information . . . . . . . . .2 2Safety . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2.1Unauthorized modification . . . . . .3 2.2General safety information . . . . . .3 2.3Specialist personnel . . . . . . . . . .3 2.4Protection from electric shock . . .3 2.5FCC note . . . . . . . . . . . . . . . . . .3 2.6ISED Statement . . . . . . . . . . . . . .4 2.7Only use genuine parts . . . . . . . .4 2.8Transport . . . . . . . . . . . . . . . . . . .4 2.9Disposal . . . . . . . . . . . . . . . . . . .4 2.10Protection from cybersecurity threats . . . . . . . . . . . . . . . . . . . . .4 Product description 3 Overview . . . . . . . . . . . . . . . . . . . . . . . . 5 3.1Scope of delivery . . . . . . . . . . . . .5 3.2Accessories . . . . . . . . . . . . . . . . .5 4Technical data . . . . . . . . . . . . . . . . . . . . 6 4.1Model identification plate . . . . . . .7 4.2Conformity assessment . . . . . . . .7 4.3Simplified declaration of con- formity . . . . . . . . . . . . . . . . . . . . .7 5Function . . . . . . . . . . . . . . . . . . . . . . . . 7 5.1Status LED . . . . . . . . . . . . . . . . .7 5.2Connections . . . . . . . . . . . . . . . .7 Installation 6 Requirements . . . . . . . . . . . . . . . . . . . . 8 6.1Installation/setup room . . . . . . . .8 6.2System requirements . . . . . . . . . .8 7Installation . . . . . . . . . . . . . . . . . . . . . . . 8 7.1Setting up the unit . . . . . . . . . . . .8 7.2Connecting the unit . . . . . . . . . . .8 8Commissioning and first start-up . . . . 9 Usage 9Operation . . . . . . . . . . . . . . . . . . . . . . . 10 9.1SmartScan . . . . . . . . . . . . . . . . .10 10Cleaning and disinfection . . . . . . . . . . . 10 10.1Surface of the unit . . . . . . . . . . . .10 11Maintenance . . . . . . . . . . . . . . . . . . . . . 11 Troubleshooting 12Tips for operators and service techni- cians . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 12.1Software error . . . . . . . . . . . . . . .12 12.2Fault on the unit . . . . . . . . . . . . .12 Contents 2162100017L29G8803V003EN-US|1 Last change: 22.11.2022 Important information 1About this document These installation and operating instructions are an integral part of the unit. Air Techniques shall not be held liable and offers no guarantees of the safe and smooth operation of this unit if you fail to comply with notes and instructions con- tained in these Installation and Operating Instructions. The German version of the installation and oper- ating instructions is the original manual. All other languages are translations of the original manual. These Installation and Operating Instructions apply to order number: 2162100010 (ULR01.1A1). 1.1Warnings and symbols Warnings The warning notes in this document highlight possible injury to persons or damage to machi- nery. They are marked with the following warning sym- bols: General warning symbol The warnings are structured as follows: SIGNAL WORD Description of type and source of danger Here you will find the possible conse- quences of ignoring the warning ❯ Follow these measures to avoid the danger. The signal word differentiates between different levels of danger: – DANGER Direct danger of severe injury or death – WARNING Possible danger of severe injury or death – CAUTION Risk of minor injuries – NOTICE Risk of extensive material/property damage Miscellaneous symbols These symbols are used in the document and on or in the unit: Note, e.g. specific instructions regarding the efficient use of the unit. Part number Serial number Model number CE mark Manufacturer Distributor Dispose of correctly in accordance with EU Directive 2012/19/EU (WEEE). Take note of the accompanying electronic documents. Please note the operating instructions. Refer to Operating Instructions. Wear hand protection. Do not reuse DC current 1.2Copyright information All electronic drawings, processes, names, soft- ware, and appliances mentioned here are pro- tected under copyright. Printing or copying these Installation and Operat- ing Instructions, including excerpts thereof, may only be carried out with the written approval of Air Techniques. Important information 2|EN-US2162100017L29G8803V003 Last change: 22.11.2022 2Safety The unit has been developed and designed appropriately such that hazards are largely excluded if the unit is used in accordance with its Intended use. Therefore, please note the following. Despite this, the following residual risks can remain: – Personal injury due to incorrect use/misuse – Personal injury due to mechanical effects – Personal injury due to electric shock – Personal injury due to radiation – Personal injury due to fire – Personal injury due to thermal effects on the skin – Personal injury due to lack of hygiene, e.g. infection 2.1Unauthorized modification Pursuant to Part 15.21 of the FCC rules, any changes or modifications to this equipment not expressly approved by the manufacturer may cause, harmful interference and void the FCC authorization to operate this equipment. 2.2General safety information ❯ Comply with the guidelines, laws, rules and regulations applicable at the site of operation when you use this unit. ❯ Prior to each use, check the function and proper condition of the device. ❯ Do not convert or modify the unit. ❯ Comply with the Installation and Operating Instructions. ❯ Make the Installation and Operating Instruc- tions always available to the operator in the vicinity of the device. 2.3Specialist personnel Operation Persons operating the unit must ensure safe and correct handling based on their training and knowledge. ❯ Instruct or have every user instructed in han- dling the unit. Installation and repairs ❯ All installation, resetting, alteration, expansion, and repair work must be carried out either…

Text truncated - open the document above for the full version.

External Photos

1 P h o t o d o c u m e n t a t i o n o f v a r i a n t U L R 0 1 . 1 D 1 1.1 External views: Top view with supplied USB cable Bottom view Front view Rear view Right view Left view Bottom view – RFID TAG Top view – RFID TAG 2 P h o t o d o c u m e n t a t i o n o f v a r i a n t U L R 0 1 . 1A1 2.1 2.1. External views: bottom view rear view top view

Internal Photos

1 P h o t o d o c u m e n t a t i o n o f t h e v a r i a n t U L R 0 1 . 1 D 1 1.1 Internal views: Open housing (bottom view) Open housing (top view) Top view of the PCB Bottom view of the PCB 1.2 Antenna dimensions 2 P h o t o d o c u m e n t a t i o n o f t h e v a r i a n t U L R 0 1 . 1A1 2.1 Internal views: Bottom view PCB in housing Top view PCB and open housing

RF Exposure Info

The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permissi on of the test laboratory . CSA Group Bayern GmbH File No. 80115210-04 Rev_0, page 1 of 10 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440 Rev. No. 6.3, 2021-11-03 CSA Confidential R F − T E S T R E P O R T - Human Exposure - Type / Model Name : ULR01 Product Description : RFID Reader Applicant : Dürr Dental SE Address : Höpfigheimer Str. 17 74321 Bietigheim-Bissingen, GERMANY Manufacturer : Dürr Dental SE Address : Höpfigheimer Str. 17 74321 Bietigheim-Bissingen, GERMANY Test Result according to the standards listed in clause 1 test standards: POSITIVE Test Report No. : 80115210-04 Rev_0 09. June 2022 ______________________________________________________________________________________________ Date of issue The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permissi on of the test laboratory . FCC ID: 2ATTE-2162100005 IC ID: 25412-2162100005 CSA Group Bayern GmbH File No. 80115210-04 Rev_0, page 2 of 10 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440 Rev. No. 6.3, 2021-11-03 CSA Confidential Contents 1 T E S T S T A N D A R D S 3 2 E Q U I P M E N T U N D E R T E S T 4 2.1 Information provided by the Client 4 2.2 Sampling 4 2.3 Photo documentation of the EUT – See ATTACHMENT A 4 2.4 Equipment type, category 4 2.5 Short description of the equipment under test (EUT) 4 2.6 EUT operation mode 5 2.7 Antennas 5 2.8 Power supply system utilised 5 3 T E S T R E S U L T S U M M A R Y 6 3.1 Revision history of test report 6 3.2 Final assessment 6 4 T E S T E N V I R O N M E N T 7 4.1 Address of the test laboratory 7 4.2 Environmental conditions 7 4.3 Statement of the measurement uncertainty 7 5 H U M A N E X P O S U R E 8 5.1 RF Exposure Test Exemptions for Single Source 8 5.2 Exemption limits for routine evaluation - SAR evaluation 9 The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permissi on of the test laboratory . FCC ID: 2ATTE-2162100005 IC ID: 25412-2162100005 CSA Group Bayern GmbH File No. 80115210-04 Rev_0, page 3 of 10 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440 Rev. No. 6.3, 2021-11-03 CSA Confidential 1 T E S T S T A N D A R D S The tests were performed according to following standards: FCC Rules and Regulations Part 1, Subpart I - Procedures Implementing the National Environmental Policy Act of 1969 Part 1, Subpart I, Section 1.1310 Radiofrequency radiation exposure limits Part 1, Subpart 2, Section 2.1091 Radiofrequency radiation exposure evaluation: mobile devices. Part 1, Subpart 2, Section 2.1093 Radiofrequency radiation exposure evaluation: portable devices. KDB 447498 D04 v01 RF Exposure procedures and equipment authorisation policies for mobile and portable devices, November 29, 2021. ANSI C95.1: 2005 IEEE Standard for Safety Levels with respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz ETSI TR 100 028 V1.3.1: 2001-03, Electromagnetic Compatibility and Radio Spectrum Matters (ERM); Uncertainties in the Measurement of Mobile Radio Equipment Characteristics—Part 1 and Part 2 The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permissi on of the test laboratory . FCC ID: 2ATTE-2162100005 IC ID: 25412-2162100005 CSA Group Bayern GmbH File No. 80115210-04 Rev_0, page 4 of 10 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440 Rev. No. 6.3, 2021-11-03 CSA Confidential 2 E Q U I P M E N T U N D E R T E S T 2.1 Information provided by the Client Please note, we do not take any responsibility for information provided by the client or his representative which may have an influence on the validity of the test results. 2.2 Sampling The customer is responsible for the choice of sample. Sample configuration, start-up and operation is carried out by the customer or according his/her instructions. 2.3 Photo documentation of the EUT – See ATTACHMENT A 2.4 Equipment type, category Select equipment type, portable equipment. 2.5 Short description of the equipment under test (EUT) ULR01 is a RFID reader, which can be connected via USB cable to a computer. It reads RFID tags (e.g. of image plates) and transfers that data to a software on the connected computer. The Reader uses the NFC controller NXP PN7150 to communicate with RFID-Tags. Tags complying to standard ISO15693 are supported. The modulation on PN7150 side is 100% Amplitude Shift Keying (ASK) pulse position coded. The RFID-Tag uses subcarrier load modulation with manchester bit coding. Number of tested samples: 1 Serial number: P464875007 The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permissi on of the test laboratory . FCC ID: 2ATTE-2162100005 IC ID: 25412-2162100005 CSA Group Bayern GmbH File No. 80115210-04 Rev_0, page 5 of 10 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440 Rev. No. 6.3, 2021-11-03 CSA Confidential 2.6 EUT operation mode The equipment under test was operated during the measurement under the following conditions: - Continuously tag reading at 13.56 MHz (full power). 2.7 Antennas The EUT has an internal antenna that is printed directly on the PCB. The dimensions are 3 cm x 2 cm. 2.8 Power supply system utilised Power supply voltage is: V nom = 5.00 V DC (powered over USB) The extreme voltage for the EUT is: V min = 4.75 V DC V max = 5.25 V dC The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written per…

Text truncated - open the document above for the full version.

Test Report

The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permissi on of the test laboratory . CSA Group Bayern GmbH File No. 80115210-02 Rev_0, page 1 of 22 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.:+49(0)9424-94810  Fax:+49(0)9424-9481440 Rev. No. 6.5, 2021-11-08 CSA Confidential EMI − T E S T R E P O R T - FCC Part 15.225, RSS 210- Type / Model Name : ULR01 Product Description : RFID Reader Applicant : Dürr Dental SE Address : Höpfigheimer Str. 17 74321 Bietigheim-Bissingen, GERMANY Manufacturer : Dürr Dental SE Address : Höpfigheimer Str. 17 74321 Bietigheim-Bissingen, GERMANY Test Result according to the standards listed in clause 1 test standards: POSITIVE Test Report No. : 80115210-02 Rev_0 07. June 2022 ______________________________________________________________________________________________ Date of issue The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permissi on of the test laboratory . FCC ID: 2ATTE-2162100005 IC ID: 25412-2162100005 CSA Group Bayern GmbH File No. 80115210-02 Rev_0, page 2 of 22 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.:+49(0)9424-94810  Fax:+49(0)9424-9481440 Rev. No. 6.5, 2021-11-08 CSA Confidential Contents 1 T E S T S T A N D A R D S 3 2 E Q U I P M E N T U N D E R T E S T 4 2.1 Information provided by the Client 4 2.2 Sampling 4 2.3 Photo documentation of the EUT – Detailed photos see ATTACHMENT A 4 2.4 Equipment type 4 2.5 Short description of the equipment under test (EUT) 4 2.6 EUT operation mode 5 2.7 EUT configuration 5 2.8 Power supply system utilised 5 3 T E S T R ES U L T S U M M A R Y 6 3.1 Revision history of test report 6 3.2 FINAL ASSESSMENT 6 4 T E S T E N V I R O N M E N T 7 4.1 Address of the test laboratory 7 4.2 Environmental conditions 7 4.3 Statement of the measurement uncertainty 7 4.4 Conformity Decision Rule 8 4.1 Measurement protocol for FCC and ISED 8 5 T E S T C O N D I T I O N S A N D R E S U L T S 10 5.1 Conducted emissions 10 5.2 Field strength of the fundamental wave 13 5.3 Spurious emissions 14 5.4 Frequency tolerance 17 5.5 Bandwidth 18 5.6 Transmitter spectrum mask 20 6 U S E D T E S T E Q U I P M E N T A N D A C C E S S O R I E S 22 The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permissi on of the test laboratory . FCC ID: 2ATTE-2162100005 IC ID: 25412-2162100005 CSA Group Bayern GmbH File No. 80115210-02 Rev_0, page 3 of 22 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.:+49(0)9424-94810  Fax:+49(0)9424-9481440 Rev. No. 6.5, 2021-11-08 CSA Confidential 1 T E S T S T A N D A R D S The tests were performed according to following standards: FCC Rules and Regulations Part 15, Subpart A - General (September 2021) Part 15, Subpart A, Section 15.31 Measurement standards Part 15, Subpart A, Section 15.33 Frequency range of radiated measurements Part 15, Subpart A, Section 15.35 Measurement detector functions and bandwidths FCC Rules and Regulations Part 15, Subpart C - Intentional Radiators (September 2021) Part 15, Subpart C, Section 15.207 Conducted limits Part 15, Subpart C, Section 15.209 Radiated emission limits, general requirements Part 15, Subpart C, Section 15.225 Operation within the band 13.110 - 14.010 MHz RSS Rules and Regulations RSS-Gen Issue 5, March 2018 General Requirements and Information for the Certification of Amendment 1 (March 2019) Radiocommunication Equipment Amendment 2 (February 2021) RSS-210 Issue 10, December 2019 Low Power Licence – Exempt Radiocommunication Devices (All Amendment (April 2020) Frequency Bands): Category I Equipment ANSI C63.10: 2013 Testing Unlicensed Wireless Devices The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permissi on of the test laboratory . FCC ID: 2ATTE-2162100005 IC ID: 25412-2162100005 CSA Group Bayern GmbH File No. 80115210-02 Rev_0, page 4 of 22 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.:+49(0)9424-94810  Fax:+49(0)9424-9481440 Rev. No. 6.5, 2021-11-08 CSA Confidential 2 E Q U I P M E N T U N D E R T E ST 2.1 Information provided by the Client Please note, we do not take any responsibility for information provided by the client or his representative which may have an influence on the validity of the test results. 2.2 Sampling The customer is responsible for the choice of sample. Sample configuration, start-up and operation is carried out by the customer or according his/her instructions. 2.3 Photo documentation of the EUT – Detailed photos see ATTACHMENT A 2.4 Equipment type RFID reader at 13.56 MHz. 2.5 Short description of the equipment under test (EUT) ULR01 is a RFID reader, which can be connected via USB cable to a computer. It reads RFID tags (e.g. of image plates) and transfers that data to a software on the connected computer. The Reader uses the NFC controller NXP PN7150 to communicate with RFID-Tags. Tags complying to standard ISO15693 are supported. The modulation on PN7150 side is 100% Amplitude Shift Keying (ASK) pulse position coded. The RFID-Tag uses subcarrier load modulation with manchester bit coding. Number of tested samples: 1 Serial number: P464875007 The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permissi on of the test laboratory . FCC ID: 2ATTE-2162100005 IC ID: 25412-2162100005 CSA Group Bayern GmbH File No. 80115210-02 Rev_0, page 5 of 22 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.:+49(0)9424-94810  Fax:+49(0)9424-9481440 Rev. No. 6.5, 2021-11-08 CSA Confidential 2.6 EUT operation mode The equipment under test was operated during the measurement under the following conditions: - Continuously tag reading at 13.56 MHz (full power). 2.7 EUT configuration The following peripheral d…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID: 2ATTE-2162100005 IC ID: 25412-2162100005 1 Photo documentation of the test set- up FCC 15.225 & RSS- 210 1.5 Conducted emissions FCC ID: 2ATTE-2162100005 IC ID: 25412-2162100005 1.5 Field strength of the fundamental wave 9 kHz – 30 MHz 9 kHz – 30 MHz FCC ID: 2ATTE-2162100005 IC ID: 25412-2162100005 1.5 Spurious emissions 9 kHz – 30 MHz 9 kHz – 30 MHz FCC ID: 2ATTE-2162100005 IC ID: 25412-2162100005 30 MHz – 1 GHz 2 H z – 1 GHz FCC ID: 2ATTE-2162100005 IC ID: 25412-2162100005 1.4 Frequency tolerance FCC ID: 2ATTE-2162100005 IC ID: 25412-2162100005 1.5 Bandwidth / Transmitter spectrum mask FCC ID: 2ATTE-2162100005 IC ID: 25412-2162100005 2.1 Ancillary Equipment FCC ID: 2ATTE-2162100005 IC ID: 25412-2162100005 FCC ID: 2ATTE-2162100005 IC ID: 25412-2162100005 FCC ID: 2ATTE-2162100005 IC ID: 25412-2162100005

Contact Information

Applicant

Oliver Lange
[email protected]+497142705190Fax: +497142705308

Test Firm

CSA Group Bayern GmbHFrank Scharnowski
[email protected]+49 9931 9836 140

Technical Specifications

#Rule PartsFrequency RangePower OutputTolerance
115C13.56 MHz - 13.56 MHz-0.0100000000 %
Confidentiality
Long Term

Other Applications from DUERR DENTAL SE

RFID Module 2144100082 - FCC ID 2ATTE-2144100082 - DUERR DENTAL SE
2ATTE-2144100082

RFID Module 2144100082

Jul 05, 2023

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
The image plate scanner is used to read image data stored on an image plate and to transfer the data to the imaging software on a computer. - FCC ID 2ATTE-2160100500 - DUERR DENTAL SE
2ATTE-2160100500

The image plate scanner is used to read image data stored on an image plate and to transfer the data to the imaging software on a computer.

Jan 16, 2020

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter