ElitechTechnology,Inc. 1551McCarthyBlvd,Suite112,Milpitas,CaliforniaUnitedStates 1|Page AttestationStatements To:FederalCommunicationsCommissionDate:Nov.27,25 7435OaklandMillsRoad, Columbia,MD21046,USA Subject:AttestationofCompliancewithFCCCoveredListSoftwareRequirements FCCID:2ATVW-M100 ProductName:AirStation Thisletterservesasanattestationthattheequipmentidentifiedaboveisnot(selectone)"covered"software asdefinedundertheFederalCommunicationsCommission(FCC)CoveredListrequirements,asoutlined inFCC22-84andKDB986446. Specifically,theundersignedcertifiesthattheequipmentforwhichauthorizationissought: 1.Doesnotcontaincybersecurityoranti-virussoftwareproducedorprovidedbyKasperskyLab, Inc.oranyofitssuccessors,assignees,parents,subsidiaries,affiliates,oranyentitythathasrebranded orrelabeledsoftwareproducedbytheaforementionedentities. 2.Doesnothavethecapabilitytostore,run,ordeliveranysoftwareidentifiedontheFCCCoveredList, includingbutnotlimitedtocybersecurityandanti-virussoftware. Tosupportthisattestation,theappendixevaluationdocumentationhasbeenpreparedandisincludedinthe certificationfiling. Thisattestationisbasedonathoroughevaluationofthedevice'sdesign,functionality,andsoftware environment.Theundersignedaffirmsthattheinformationprovidedisaccurateandcompletetothebestof theirknowledge. Sincerelyyours, PrintedName:tingLiu Title:Manager Address:1551McCarthyBlvd,Suite112,Milpitas,CaliforniaUnitedStates Tel.:4088982866 Email:[email protected] ElitechTechnology,Inc. 1551McCarthyBlvd,Suite112,Milpitas,CaliforniaUnitedStates 2|Page EvaluationregardingtotheCoveredListSoftware: Compliance Methodology EvaluationProcessResults Deviceis Inherent compliance ☒ TheChipset(s)usedislimitedtorun theCybersecurityoranti-virus software. Compliance ☒ TheMemoryusedislimitedtorunthe Cybersecurityoranti-virussoftware. Compliance ☒ Thereisstoragecapacitylimitationfor storeorinstalltheCybersecurityor anti-virussoftware. Compliance ☒ Operatingsystemusedislimitedto run,installordelivertheCybersecurity oranti-virussoftware. Compliance Deviceisnot Inherent compliance ☐ EvaluationBasedonSoftware BillofMaterials(SBoM) Seeattached“SBoM“ Note:TheSBoMcontentislimited tothescopeofcoveredlist software(e.g.antivirusand cybersecuritysoftware). ☐ EvaluationBasedonScanfor Softwareonthedevice ☐ EvaluationBasedonFilesystemscan ☐ EvaluationBasedonRunning softwarecheck
ElitechTechnology,Inc. 1551McCarthyBlvd,Suite112,Milpitas,CaliforniaUnitedStates AttestationStatements NotCoveredEntityApplicant&NotCoveredEquipment To:FederalCommunicationsCommissionDate:11/19/2025 7435OaklandMillsRoad, Columbia,MD21046,USA Ref:InformationRequiredbySection2.911(d)(5)(i)&(ii) FCCID:2ATVW-M100 ElitechTechnology,Inc.certifiesthat,asofthedateofthefilingoftheapplication,theapplicantisnot identifiedontheCoveredList,establishedpursuantto§1.50002ofreferencechapter,asanentity producing“covered”communicationequipment.Theequipmentforwhichauthorizationissoughtisnot “covered”telecommunicationsequipmentandvideosurveillanceequipmentproducedbyentities identifiedontheCommission’sCoveredListthatprohibitedfromreceivinganequipmentauthorization pursuanttosection§2.903oftheFCCrules. Sincerelyyours, PrintedName:tingLiu Title:Manager Address:1551McCarthyBlvd,Suite112,Milpitas,CaliforniaUnitedStates Tel.:4088982866 Email:[email protected]
ElitechTechnology,Inc. 2.911(d)(7)USAAgentv1.5 Section2.911(d)(7)USAAgentforServiceofProcess Companyname:ElitechTechnology,Inc. Address:1551McCarthyBlvd,Suite112,Milpitas,CaliforniaUnitedStates FCCID:2ATVW-M100 2.911(d)(7)USADesignatedAgentforServiceofProcess We,[ElitechTechnology,Inc.]designate[ElitechTechnology,Inc.] NOTE1 forthe purposeofacceptingserviceofprocessonbehalfoftheapplicant. Applicantconsent:Weacknowledgeourconsenttoacceptserviceofprocessinthe UnitedStatesformattersrelatedtotheapplicableequipment,andatthephysicalU.S. addressandemailaddressofthedesignatedagentandacknowledgeouracceptance ofourobligationtomaintainanagentforserviceofprocessintheUnitedStatesforno lessthanoneyearaftereitherwethegranteehavepermanentlyterminatedall marketingandimportationoftheapplicableequipmentwithintheU.S.,oratthe conclusionofanyCommission-relatedadministrativeorjudicialproceedinginvolving theequipment,whicheverislater. Agentobligation:Weacknowledgeourobligationtoacceptserviceofprocessinthe UnitedStatesformattersrelatedtotheapplicableequipmentatourphysicalU.S. addressandemailaddressfornolessthanoneyearaftereitherthegranteehas permanentlyterminatedallmarketingandimportationoftheapplicableequipment withintheU.S.,orattheconclusionofanyCommission-relatedadministrativeor judicialproceedinginvolvingtheequipment,whicheverislater. USAAgentApplicant Companyname:ElitechTechnology,Inc.Companyname:ElitechTechnology,Inc. USAAddress:1551McCarthyBlvd,Suite 112,Milpitas,CaliforniaUnitedStates Address:1551McCarthyBlvd,Suite112, Milpitas,CaliforniaUnitedStates FRNNumber:0028621266GranteeFRNNumber:0028621266 ContactName:tingLiuFCCGranteeCode:2ATVW TelephoneNo:(408)898-2866ContactName:tingLiu Email:[email protected]:(408)898-2866 Email:[email protected] Signature: Title:Manager Signature: Title:Manager Date:2025-11-27Date:2025-11-27 ElitechTechnology,Inc. 2.911(d)(7)USAAgentv1.5 NOTE1:AnapplicantlocatedintheUnitedStatesmaydesignateitselfastheagentforservice ofprocess. Reference;FederalRegisterdocument2022-28263publishedon02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-nation al-security-threats-to-the-communications-supply-chain-through-the
ElitechTechnology,Inc. 1551McCarthyBlvd,Suite112,Milpitas,CaliforniaUnitedStates 11/19/2025 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Subject:ConfidentialityRequestfor:FCCID:2ATVW-M100 PursuanttoSections0.457and0.459oftheCommission’sRules,weherebyrequestpermanent confidentialtreatmentoftheexhibitsaccompanyingthiscertificationapplicationasoutlinedbelow: BlockDiagram Schematics OperationalDescription Theaboveexhibitscontaintradesecretsand/orproprietaryinformationthatarenotpubliclyavailableand materialsthattheApplicanthasspentconsiderableeffortsindeveloping.Publicdisclosureofthesemay beharmfultotheApplicantandgiveanunfairadvantagetocompetitorsonthemarket. PursuanttoDA04-1705,theapplicantalsorequeststemporaryconfidentialtreatmentoftheexhibits outlinedbelowforaperiodof(upto180)daysfromthedateofequipmentauthorizationandpriorto marketingintheUnitedStatestopreventtheprematurereleaseofanysensitiveinformation.Applicantis awareoftheirresponsibilitytonotifyDERYCOMintheeventinformationregardingtheproductorthe productismadeavailabletothepublicbeforetherequestedperiodhasexpired. UserManual InternalPhotos ExternalPhotos TestSetupPhotos Sincerely, Title:Manager Address:1551McCarthyBlvd,Suite112,Milpitas,CaliforniaUnitedStates Tel.:4088982866 Email:[email protected]
ElitechTechnology,Inc. 1551McCarthyBlvd,Suite112,Milpitas,CaliforniaUnitedStates 2025/11/19 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Subject:AgentAuthorizationforFCCID:2ATVW-M100 I,theundersigned,herebyauthorize(ShenzhenAnbotekComplianceLaboratoryLimited.)toactonour behalfinallmattersrelatingtothisapplicationforequipmentcertification. Anyactcarriedoutby(ShenzhenAnbotekComplianceLaboratoryLimited.)shallhavethesameeffectas ourownandIacknowledgethatallresponsibilityforcomplyingwiththetermsandconditionsof certification,asspecifiedbyDERYCOMCERTIFICATIONSERVICES,INC.,stillresideswith(Elitech Technology,Inc.). WecertifythatwearenotsubjecttoadenialoffederalbenefitsthatincludesFCCbenefitspursuantto Section5301oftheAnti-DrugAbuseActof1988,21U.S.C.§862,andthatnopartytotheapplication,as definedin47CFR§1.2002(b),issubjecttoadenialoffederalbenefitsthatincludesFCCbenefits pursuanttothatsection. Sincerely, PrintedName:tingLiu Title:Manager Tel.:4088982866 Fax:4088982866 Email:[email protected]
ElitechTechnology,Inc. 1551McCarthyBlvd,Suite112,Milpitas,CaliforniaUnitedStates ProductSimilarityDeclaration Productname:AirStation Modelname:W100,M100,M1002nd,W100Pro,W100SE FCCID:2ATVW-M100 We(ElitechTechnology,Inc.)herebystatethatallthemodelsare electricalidenticalincludingthesamesoftwareparameterand hardwaredesign(i.e.,circuitdesign,PCBLayout,RF module/circuit,antennatype(s)andantennalocation,components onPCB,etc.,),samemechanicalstructureanddesign(including productenclosure,materials,etc.,),Allsamplesarethesame exceptthemodelnumberandfunction. Signature: Name:tingLiu Title:Manager Date:Nov.27,25
LabelLocation: Confirmtheuseofrealappearancephotosasreferences. Air Station (US)
RFEXPOSUREEVALUATION KDB447498D01MobileandPortableDevicesRFExposureProceduresand EquipmentAuthorizationPoliciesv06. AccordingtoFCC1.1310:Thecriterialistedinthefollowingtableshallbeused toevaluatetheenvironmentimpactofhumanexposuretoradiofrequency(RF) Radiationasspecifiedin§1.1307(b) EUTSpecification FCCID2ATVW-M100 EUT AirStation Frequencyband(Operating)BT:2.402GHz~2.480GHz WLAN:2.412GHz~2.462GHz RLAN:5.180GHz~5.240GHz RLAN:5.260GHz~5.320GHz RLAN: 5.500 GHz~ 5.700 GHz RLAN:5.745GHz~5.825GHz Others:911MHz,915MHz,919MHz DevicecategoryPortable(<20cmseparation) Mobile(>20cmseparation) Others___ ExposureclassificationOccupational/Controlledexposure(S=5mW/cm2) GeneralPopulation/Uncontrolledexposure(S=1mW/cm2) AntennadiversitySingleantenna Multipleantennas Txdiversity Rxdiversity Tx/Rxdiversity Antennagain(Max) SRD: 3.79dBi EvaluationappliedMPEEvaluation SAREvaluation LimitsforMaximumPermissibleExposure(MPE) Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) Power Density(mW/cm 2 ) Average Time (A)LimitsforOccupational/ControlExposures 300-1500----F/3006 1500-100000----56 (B)LimitsforGeneralPopulation/UncontrolExposures 300-1500----F/15006 1500-100000----130 Friistransmissionformula:Pd=(Pout*G)\(4*pi*R2) Where Pd=PowerdensityinmW/cm 2 Pout=outputpowertoantennainMw G=gainofantennainlinearscale Pi=3.1416 R=distancebetweenobservationpointandcenteroftheradiatorincm PdthelimitofMPE,1mW/cm2.Ifweknowthemaximumgainoftheantenna andtotalpowerinputtotheantenna,throughthecalculation,wewillknowthe distancewheretheMPElimitisreached. MaxMeasurementResult OperatingMode Measured Power Tuneup tolerance Max.Tune upPower Antenna Gain Power densityat 20cm Power densityLimits (mW/cm 2 ) (dBm)(dBm)(dBm)(dBi)(mW/cm 2 ) Low11.88711.887±112.893.790.00931 Middle11.70711.707±112.713.790.00891 High11.52211.522±112.523.790.00851
Page 1 of 33 FCC Test Report Report No.:1812C50519712501 Applicant:Elitech Technology, Inc. Address: 1551 McCarthy Blvd, Suite 112, Milpitas, California United States Product Name:Air Station Report Date:2025-11-19 Shenzhen Anbotek Compliance Laboratory Limited #检测章# #资质章# Report No.:1812C50519712501Page 2 of 33 FCC ID: 2ATVW-M100 Contents 1. General Information ...............................................................................................................................6 1.1. Client Information ........................................................................................................................6 1.2. Description of Device (EUT) ........................................................................................................6 1.3. Auxiliary Equipment Used During Test........................................................................................7 1.4. Operation channel list..................................................................................................................7 1.5. Description of Test Modes...........................................................................................................7 1.6. Measurement Uncertainty ...........................................................................................................7 1.7. Additional Instructions .................................................................................................................8 1.8. Test Summary .............................................................................................................................8 1.9. Description of Test Facility ..........................................................................................................9 1.10. Disclaimer..................................................................................................................................9 1.11. Test Equipment List.................................................................................................................10 2. Antenna requirement ...........................................................................................................................12 2.1. Conclusion.................................................................................................................................12 3. Conducted Emission at AC power line ................................................................................................13 3.1. EUT Operation ..........................................................................................................................13 3.2. Test Setup .................................................................................................................................13 3.3. Test Data ...................................................................................................................................14 4. 6dB Bandwidth ....................................................................................................................................16 4.1. EUT Operation ..........................................................................................................................16 4.2. Test Setup .................................................................................................................................16 4.3. Test Data ...................................................................................................................................17 5. Maximum Conducted Output Power....................................................................................................18 5.1. EUT Operation ..........................................................................................................................18 5.2. Test Setup .................................................................................................................................18 5.3. Test Data ...................................................................................................................................19 6. Power Spectral Density .......................................................................................................................20 6.1. EUT Operation ..........................................................................................................................20 6.2. Test Setup .................................................................................................................................20 6.3. Test Data ...................................................................................................................................21 7. Emissions in non-restricted frequency bands ......................................................................................22 7.1. EUT Operation ..........................................................................................................................22 7.2. Test Setup .................................................................................................................................22 7.3. Test Data ...................................................................................................................................23 8. Emissions in restricted frequency bands (below 1GHz) ......................................................................25 8.1. EUT Operation ..........................................................................................................................25 8.2. Test Setup .................................................................................................................................26 8.3. Test Data ...................................................................................................................................27 9. Emissions in restricted frequency bands (above 1GHz)......................................................................29 9.1. EUT Operation ......................…
Text truncated - open the document above for the full version.
M100 2ND Antenna test report 上海圣丹纳无线科技有限公司 Shanghai Saintenna Wireless Technology Co., LTD. Room 601, Building 1, No. 69 Yuanfeng Road, Baoshan District, Shanghai 客户名称 Customer Name Elitech Technology, Inc. 项目名称 Project Name M100 2ND 工作频段 Working Band 863-873MHz/910-920MHz 规格 Description 版本 Version V1.0 日期 Date 2025.8.4 Project Information Tuning Instrument Network AnalyzerAgilent E5071C Frequency Range 100KHz ~ 8.5GHz Test Item Return Loss/VSWR/Smith Chart /Isolation Typical Setup for Test System Combined-Axes System Anechoic Chamber +X +Y +Z Combined-Axes System Comment: E1 plane means XZ section, E2 plane means YZ section, H plane means XY section. Antenna Sample Description 天线位置 Cable线出 线方向 Matching Circuit ANT RF Module A1 A2 A3 A1/ A20ohm A3/ S11 Test Result - Passive Freq. (MHz) Gain (dBi) Eff. 8633.6459.18% 8683.760.73% 8733.761.4% 9103.7963.61% 9153.5563.26% 9203.5163.41% Radiation Pattern 868MHzE1 E2H 915MHzE1 E2H
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 911 MHz - 919 MHz | 15.40 mW |

Electronic Refrigerant Scale
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Handle Remote Controller
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Disposable iot logger
Equipment Class
PCB - PCS Licensed Transmitter