ShenzhenWesionTechnologyCo.,Ltd. 2701QIANCHENGCENTER,HAICHENGROAD,XIXIANGSTREET,BAO'ANDISTRICT,SHENZHEN ViviInstructions Name:ViviWirelessPresentation model:VWP-300-16 InstallingtheBox SkiptoendofmetadataGotostartofmetadata ToinstalltheBox,youwillneed: 1.Anactivenetworkportonyourlocalnetwork. 2.ADisplaywhichcanbeconnectedusingaHDMIcable. 3.Apoweroutlet. Theseallneedtobeclosetoeachother–atleastfortheinitialsetup. OncetheBoxispluggedin,itwillbootup.Makesuretheotherconnectionsareinplace first. Dependingonthesetupofyourlocalnetwork,additionalnetworksettingsmaybeneeded beforetheBoxcanbefullyactivated. Antenna OnWi-Fimodelsonly,connecttheantennatothebackoftheBox. Ethernet ConnecttheethernetcablefromtheBoxtoyournetwork. Makesurebothendsofthenetworkcablearepluggedin,andthatthecorresponding networkportispatchedattheswitch. IfyouneedtoregistertheMACaddressoftheBoxtogainaccesstothelocalnetwork,itis writtenonthesideoftheBox.Thetextwilllooklike"D063B401C7F9"andcorrespondsto aMACaddressofd0:63:b4:01:c7:f9. OnWi-Fimodels,thenetworksettingsoftheBoxcanbeupdatedtouseWi-Filater,butan ethernetconnectionisneededthefirsttimearoundsothattheBoxcanbeactivated. ShenzhenWesionTechnologyCo.,Ltd. 2701QIANCHENGCENTER,HAICHENGROAD,XIXIANGSTREET,BAO'ANDISTRICT,SHENZHEN HDMI ConnecttheHDMIcablefromyourDisplaydevicetotheViviBox. TheHDMIcablecanbeconnectedtoaVGADisplayviaaHDMItoVGAconvertorora HDMItoDVIconvertor.However,thiswillonlytransmitvideo,andnoaudio. HumanInterfaceDevice(HID)complianttouchscreenscanalsobeusedandcanbe connectedviatheUSBconnection. Wheninitiallysettingupthedevice,itisbestifaHDMI-capableDisplaydeviceisusedto simplifyanytroubleshootingthatisrequired. USBconnections TheViviBoxhastwoUSBconnections.Theycanbeusedforthefollowing: 1.ConnectingaUSBaudiodevice. 2.ConnectingaHIDcomplianttouchscreen. 3.PerformingafactoryresetoftheBoxviaaUSBdrive.Factoryresetsrequirethe assistanceoftheViviSupportteam. ACPower/PoweroverEthernet OncetheBoxispluggedin,itwillbootup.Makesurealloftheotherconnectionsarein placefirst. TherearetwooptionsforpoweringtheViviBox. PowercanbeprovidedbytheACpoweradapter(12V1.5ADC).Powercanalsobe providedbythePoweroverEthernet(PoE)splitter. OnewillhavebeenprovidedwiththeBox,basedonyourorder. IftheBoxwilllaterbeconfiguredtouseWi-Fiaccesstoconnecttothelocalnetwork,then theACadaptermustbeused. TousethePoEsplitter,disconnecttheethernetcablefromtheBox,andconnectboththe ethernetconnectionandthepowerconnectorfromthePoEsplitterintotheBox.The ethernetcableconnecttotheotherendofthePoEsplitter. Pleasenote:Notallnetworkscanprovidepowerviathenetworkorareconfiguredtodo soasstandard. Ifthepowerisworking,theredlight(nexttothepowerconnectionontheBox)willturnon. ShenzhenWesionTechnologyCo.,Ltd. 2701QIANCHENGCENTER,HAICHENGROAD,XIXIANGSTREET,BAO'ANDISTRICT,SHENZHEN BootupandBoxactivation WhenyoufirstpluginanewBox,itmaytakeafewminutestoself-extractitsoperating systemandgetitselfreadyforuse–thisonlyhappensthefirsttime.Atthispointyou shouldseearedlightontheBox. Afterafewstartupsteps,theVivilogoandeithertheBoxnameoraroomnamewill appearontheDisplay.TheDisplaymayflickerforafewsecondswhilethedeviceinstalls andactivates.Whenthedevicehasinstalledandisreadytogoyoushouldseesomething likethis: IftheViviBoxhasbeenunabletoactivateitself,thefollowingmessagewillbedisplayed: ShenzhenWesionTechnologyCo.,Ltd. 2701QIANCHENGCENTER,HAICHENGROAD,XIXIANGSTREET,BAO'ANDISTRICT,SHENZHEN Ifyouseethismessageonstart-up,additionalnetworkconfigurationupdateswillbe required.Addtherequiredfirewallexceptionsandopentherequiredinternalnetwork ports.Oncetheyareinplace,disconnectandreconnectthepowersothattheBoxcan rebootandrunthroughtheactivationprocessagain. FCCStatement ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigitaldevice, pursuanttopart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotection againstharmfulinterferenceinaresidentialinstallation.Thisequipmentgenerates,usesandcan radiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructions, maycauseharmfulinterferencetoradiocommunications.However,thereisnoguaranteethat interferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoescauseharmful interferencetoradioortelevisionreception,whichcanbedeterminedbyturningtheequipment offandon,theuserisencouragedtotrytocorrecttheinterferencebyoneormoreofthe followingmeasures: Reorientorrelocatethereceivingantenna. Increasetheseparationbetweentheequipmentandreceiver. Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiveris connected. Consultthedealeroranexperiencedradio/TVtechnicianforhelp. Caution:Anychangesormodificationstothisdevicenotexplicitlyapprovedbymanufacturer couldvoidyourauthoritytooperatethisequipment. Thisdevicecomplieswithpart15oftheFCCRules.Operationissubjecttothefollowingtwo conditions:(1)Thisdevicemaynotcauseharmfulinterference,and(2)thisdevicemustaccept anyinterferencereceived,includinginterferencethatmaycauseundesiredoperation. RFExposureInformation ThisequipmentcomplieswithFCCradiationexposurelimitssetforthforanuncontrolled environment.Thisequipmentshouldbeinstalledandoperatedwithminimumdistance20cm betweentheradiatorandyourbody.
Vivi International Pty Ltd Suite 2, 21/627 Chapel Street, South Yarra,Melbourne VIC Australia Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2024-10-12 To whom it may concern: We, Vivi International Pty Ltd, hereby certify that the equipment for which authorization is sought (FCC ID: 2AU3Z-VWP300) is not “covered” equipment prohibited from receiving an equipment authorization pursuant to § 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, we are not identified on the Covered List (https://www.fcc.gov/supplychain/coveredlist) as an entity producing “covered” equipment. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(b) and (d)(5) and (6). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. Sincerely, Signature Ian Shrimpton Manager Vivi International Pty Ltd 62_[model] CoveredEqu_2.911(d)(5)(i) and (ii) - U, V03
ViviInternationalPtyLtd FederalCommunicationsCommission AuthorizationandEvaluationDivision EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MD21046 8/8/24 U.S.AgentDesignation [ViviInternationalPtyLtd]acknowledgestheirconsentforthefollowingcontactlocatedintheUnitedStatesto actastheiragentforserviceofprocessfortheequipmentforwhichauthorizationissought(FCCID:2AU3Z- VWP300): NameandcompanyofU.S.agent:VIVILLC PhysicalU.S.addressofagent:3120SouthwestFwy.Suite101,PMB58791,Houston,TX77080- 2059,UnitedStates FRNofU.S.agent:0035718485 EmailaddressofU.S.agent:[email protected] [VIVILLC]acknowledgestheirobligationtoacceptserviceofprocessonbehalfof[ViviInternationalPtyLtd]. [ViviInternationalPtyLtd]withtheFRN[0028967537]acceptsitsobligationtomaintainanagentforserviceof processintheUnitedStatesfornolessthanoneyearaftereitherthegranteehaspermanentlyterminatedall marketingandimportationoftheapplicableequipmentwithintheU.S.,ortheconclusionofanyCommission- relatedadministrativeorjudicialproceedinginvolvingtheequipment,whicheverislater. Bysigningthisform,weconfirmtheaboveandthatweareawareoftheapplicationrequirementslistedunder§ 2.911(d)(7). TheinformationprovidedinthisletterisbasedonthereferencedrulepartsofTitle47oftheCFRaswellasKDB 986446D01. Anexpirationdateforthisletterdoesnotexist.IncasetheU.S.agentchanges,thegranteeisobligatedtonotify theFCCwithin30daysviathegrantingTCB. Sincerely, Signature [Ian.Shrimpton] [Manager] [ViviInternationalPtyLtd] Signature [Ian.Shrimpton] [Manager] [VIVILLC] 4 8 _ [ m o d e l ] U S _ A g e n t _ 2 . 9 1 1 ( d ) ( 7 ) - U , V 0 5
CONFIDENTIALITY REQUEST for Certification Service in USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21046 Date:<2024-10-12> Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we requests confidentiality for the following products: FCC ID Model name 2AU3Z-VWP300 VWP-300-16 For the product stated above, we request that the following information be held confidential; Exhibits Long-Term Confidentiality Short-Term Confidentiality Short-Term Confidentiality Days External Photos Internal Photos Block Diagram Schematics Test Setup Photos User’s Manual Parts List Tune Up Operational Descriptions The long-term confidentiality exhibits contain our trade secrets and proprietary information that could be of benefit to our competitors. The short-term confidentiality on the basis of ensuring that business sensitive information remains confidential until the actual marketing of our new device. If you have any questions, please feel free to contact me at the address shown below. Sincerely, Name/Title: Ian Shrimpton/Manager Company: Vivi International Pty Ltd Address: Suite 2, 21/627 Chapel Street, South Yarra,Melbourne VIC Australia Phone: 611300920555 Fax: 611300920555 E-Mail: [email protected]
Vivi International Pty Ltd Suite 2, 21/627 Chapel Street, South Yarra,Melbourne VIC Australia Date: 2024-10-12 FCC ID: 2AU3Z-VWP300 Model Number: VWP-300-16 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD To Whom It May Concern, We, Vivi International Pty Ltd, declare that this EUT (FCC ID: 2AU3Z-VWP300) doesn’t have Ad Hoc mode function on “non-US/Canada frequencies”. In addition. The frequency selection feature is disabled by firmware for devices marked to the US/Canada. For DTS part of this device, only channels 1-11 will be used in North America, Country code selection is disabled. Should you have any questions or comments regarding this matter, please have my best attention. Sincerely, Name/Title: Ian Shrimpton/Manager Company: Vivi International Pty Ltd Address: Suite 2, 21/627 Chapel Street, South Yarra,Melbourne VIC Australia Phone: 611300920555 Fax: 611300920555 E-Mail: [email protected]
Vivi International Pty Ltd Suite 2, 21/627 Chapel Street, South Yarra,Melbourne VIC Australia Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2024-10-12 To whom it may concern: We, the undersigned, hereby authorize Eurofins Product Service GmbH to act on our behalf in all matters relating to applications for equipment authorization FCC ID: 2AU3Z-VWP300 including the signing of all documents related to these matters. Any and all acts carried out by Eurofins Product Service GmbH on our behalf shall have the same effect as acts of our own. By signing this application form, we agree to Eurofins’ current valid General Terms and Conditions (AGB),Testing and Certification Regulations (PZO) which can be viewed on following website www.eurofins.de/ee or retrieved on request. We also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Sincerely, Name/Title: Ian Shrimpton/Manager Company: Vivi International Pty Ltd Address: Suite 2, 21/627 Chapel Street, South Yarra,Melbourne VIC Australia Phone: 611300920555 Fax: 611300920555 E-Mail: [email protected]
Page1of5FCCID:2AU3Z-VWP300 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity ExternalPhotosoftheEUT Fig.1 Fig.2 WiFiAntenna1 WiFiAntenna0 Page2of5FCCID:2AU3Z-VWP300 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of5FCCID:2AU3Z-VWP300 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6 Page4of5FCCID:2AU3Z-VWP300 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.7 Fig.8 Page5of5FCCID:2AU3Z-VWP300 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.9
Page1of1 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity LABELANDLOCATION LabelLocation
Page1of3FCCID:2AU3Z-VWP300 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity InternalPhotosoftheEUT Fig.1 Fig.2 Page2of3FCCID:2AU3Z-VWP300 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of3FCCID:2AU3Z-VWP300 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6
Page1of21FCCID:2AU3Z-VWP300 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity MaximumPermissibleExposureReport 1.ProductInformation EUT:ViviWirelessPresentation TestModel:VWP-300-16 PowerSupply: Input:5V3A ForACAdapter:Input:100-240V~,50/60Hz,0.8A Output:5.0V3.0A,15.0W HardwareVersion:V14 SoftwareVersion:Android9.0 Bluetooth: FrequencyRange:2402MHz~2480MHz ChannelNumber:79channelsforBluetoothV5.3(DSS) 40channelsforBluetoothV5.3(DTS) ChannelSpacing:1MHzforBluetoothV5.3(DSS) 2MHzforBluetoothV5.3(DTS) ModulationType:GFSK,π/4-DQPSK,8-DPSKforBluetoothV5.3(DSS) GFSKforBluetoothV5.3(DTS) BluetoothVersion:V5.3 AntennaDescription:Antenna0:ExternalAntenna,2.91dBi(max.) WIFI(2.4GBand): FrequencyRange:2412MHz~2462MHz ChannelNumber:11Channelsfor20MHzbandwidth(2412~2462MHz) 7Channelsfor40MHzbandwidth(2422~2452MHz) ChannelSpacing:5MHz ModulationType:IEEE802.11b:DSSS(CCK,DQPSK,DBPSK) IEEE802.11g:OFDM(64QAM,16QAM,QPSK,BPSK) IEEE802.11n:OFDM(64QAM,16QAM,QPSK,BPSK) IEEE802.11ax:OFDMA(1024QAM,256QAM,64QAM,16QAM,QPSK, BPSK) AntennaDescription:Antenna0:ExternalAntenna,2.91dBi(Max.) Antenna1:ExternalAntenna,2.91dBi(Max.) WIFI(5.2GBand): FrequencyRange:5180MHz~5240MHz ChannelNumber:4Channelsfor20MHzbandwidth(5180MHz~5240MHz) 2channelsfor40MHzbandwidth(5190MHz~5230MHz) 1channelsfor80MHzbandwidth(5210MHz) ModulationType:IEEE802.11a:OFDM(64QAM,16QAM,QPSK,BPSK) IEEE802.11n:OFDM(64QAM,16QAM,QPSK,BPSK) Page2of21FCCID:2AU3Z-VWP300 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity IEEE802.11ac:OFDM(256QAM,64QAM,16QAM,QPSK,BPSK) IEEE802.11ax:OFDMA(1024QAM,256QAM,64QAM,16QAM,QPSK, BPSK) AntennaDescription:Antenna0:ExternalAntenna,3.26dBi(Max.) Antenna1:ExternalAntenna,3.26dBi(Max.) 5.3GWLAN FrequencyRange:5250-5350MHz ChannelNumber:4Channelsfor20MHzbandwidth(5260MHz-5320MHz) 2channelsfor40MHzbandwidth(5270MHz~5310MHz) 1channelsfor80MHzbandwidth(5290MHz) ModulationType:IEEE802.11a:OFDM(64QAM,16QAM,QPSK,BPSK) IEEE802.11n:OFDM(64QAM,16QAM,QPSK,BPSK) IEEE802.11ac:OFDM(256QAM,64QAM,16QAM,QPSK,BPSK) IEEE802.11ax:OFDM(1024QAM,256QAM,64QAM,16QAM,QPSK,BPSK) AntennaDescription:Ant0:ExternalAntenna,3.18dBi(Max.) Ant1:ExternalAntenna,3.18dBi(Max.) 5.5GWLAN FrequencyRange:5470-5725MHz ChannelNumber:11Channelsfor20MHzbandwidth(5500MHz-5700MHz) 5Channelsfor40MHzbandwidth(5510MHz-5670MHz) 2Channelsfor80MHzbandwidth(5530MHz,5610MHz) ModulationType:IEEE802.11a:OFDM(64QAM,16QAM,QPSK,BPSK) IEEE802.11n:OFDM(64QAM,16QAM,QPSK,BPSK) IEEE802.11ac:OFDM(256QAM,64QAM,16QAM,QPSK,BPSK) IEEE802.11ax:OFDM(1024QAM,256QAM,64QAM,16QAM,QPSK,BPSK) AntennaDescription:Ant0:ExternalAntenna,3.03dBi(Max.) Ant1:ExternalAntenna,3.03dBi(Max.) WIFI(5.8GBand): FrequencyRange:5745MHz~5825MHz ChannelNumber:5channelsfor20MHzbandwidth(5745MHz~5825MHz) 2channelsfor40MHzbandwidth(5755MHz~5795MHz) 1channelsfor80MHzbandwidth(5775MHz) ModulationType:IEEE802.11a:OFDM(64QAM,16QAM,QPSK,BPSK) IEEE802.11n:OFDM(64QAM,16QAM,QPSK,BPSK) IEEE802.11ac:OFDM(256QAM,64QAM,16QAM,QPSK,BPSK) IEEE802.11ax:OFDMA(1024QAM,256QAM,64QAM,16QAM,QPSK, BPSK) AntennaDescription:Antenna0:ExternalAntenna,3.47dBi(Max.) Antenna1:ExternalAntenna,3.47dBi(Max.) Exposurecategory:Generalpopulation/uncontrolledenvironment EUTType:ProductionUnit DeviceType:MobileDevice Page3of21FCCID:2AU3Z-VWP300 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 2.EvaluationMethod SystemsoperatingundertheprovisionsofFCC47CFRsectionshallbeoperatedinamannerthatensures thatthepublicisnotexposedtoradiofrequencyenergylevelinexcessoftheCommission’sguidelines. Inaccordancewith47CFRFCCPart2SubpartJ,section2.1091thisdevicehasbeendefinedasmobile devicewherebyadistanceof0.2mnormallycanbemaintainedbetweentheuserandthedevice,andbelow RFPermissibleExposurelimitshallcomplywith. InaccordancewithKDB447498D01forSimultaneoustransmissionMPEtestexclusionapplieswhenthesum oftheMPEratiosforallsimultaneoustransmittingantennasincorporatedinahostdevice,basedonthe calculated/estimated,numericallymodelledormeasuredfieldstrengthsorpowerdensity,is≤1.0.TheMPE ratioofeachantennaisdeterminedattheminimumtestseparationdistancerequiredbytheoperating configurationsandexposureconditionsofthehostdevice,accordingtotheratiooffieldstrengthsorpower densitytoMPElimit,atthetestfrequency.Eitherthemaximumpeakorspatiallyaveragedresultsfrom measurementsornumericalsimulationsmaybeusedtodeterminetheMPEratios.Spatialaveragingdoesnot applywhenMPEisestimatedusingsimplecalculationsbasedonfar-fieldplane-waveequivalentconditions. Theantennainstallationandoperatingrequirementsforthehostdevicemustmeettheminimumtest separationdistancesrequiredbyallantennas,inbothstandaloneandsimultaneoustransmissionoperations, tosatisfycompliance. 3.Limit 3.1ReferEvaluationMethod ANSIC95.1–2019:IEEEStandardforSafetyLevelswithRespecttoHumanExposuretoElectric,Magnetic, andElectromagneticFields,0Hzto300GHz FCCKDBpublication447498D01General1RFExposureGuidancev06:MobileandPortableDevicesRF ExposureProceduresandEquipmentAuthorizationPolicies. FCCCFR47part11.1310:Radiofrequencyradiationexposurelimits. FCCCFR47part22.1091:Radiofrequencyradiationexposureevaluation:mobiledevices. 3.2Limit LimitsforMaximumPermissibleExposure(MPE)/ControlledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforOccupational/ControlledExposure 0.3–3.0 3.0–30 30–300 300–1500 1500–100,000 614 1842/f 61.4 / / 1.63 4.89/f 0.163 / / (100)* (900/f 2 )* 1.…
Text truncated - open the document above for the full version.
ShenzhenXingtongWieressTechnologyCo.,Ltd Phone:+86-755-27850514Fax:+86-0755-27850514 Address:3rdFloor,BuildingA1,JiuweiQiangrongdongIndustrial Zone,Xixiang,Bao'anDistrict,Shenzhen Productspecificationsheet Productnumber: ProductName:WIFIstickantenna Productpartnumber:SYX.1.2.001 producerReviewerDate JiajunHuangYanlongWu 2024-05-15 Customerconfirmation CustomerName:SHENZHENWESIONTECHNOLOGYCO., LTD. Approval: Time: Notes: Date2024-05-15 VersionA0 ShenzhenXingtongWieressTechnologyCo.,Ltd Documentnumber XT-YF-004 ProductName WIFIstickantenna Productnumber 1.ProductConstrution 1.Antennamaterial:silicone+ABS+coppertube+SMA 2.Packagingprocess:assembly+welding+electroplating 3.Antennasize:108.5*9.4(tolerance±1mm) 4.Productdescription:2.4G+5.8Gdualbandwifiantenna,totallength108.5±1mm, SMAmalepinwith90degreebendingconnector 2.parameters Scopeofuse:Customersuppliedmachines Antennafrequency:2400-2500Mhz5150-5850Mhz Antennavoltagestandingwaveratio:2.4G<1.55.8G<1.5 Antennafreespacegain:2.4≥2.0dbi5.8≥2.0dbi Antennaimpedance:50Ω Installationmethod:SMAconnectiontomotherboardOUT 3.AntennaS11value 3.1:Antennastandingwaveratio 3.2:Antennareturnlossvalue Page1 Date2024-05-15 VersionA0 ShenzhenXingtongWieressTechnologyCo.,Ltd Documentnumber XT-YF-004 ProductName WIFIstickantenna Productnumber 4.Antenna(OTA)testingenvironment 4.1:Testingenvironmentandinstruments:3Dmicrowaveanechoicchamber,network analyzer,PCtestingsoftware,engineeringsamples,10dBattenuator,etc 4.2:Antennaefficiency/gain Page2 Date2024-05-15 VersionA0 ShenzhenXingtongWieressTechnologyCo.,Ltd Documentnumber XT-YF-004 ProductName WIFIstickantenna Productnumber 4.3:AntennaOTA-2.4G-3D 4.4:AntennaOTA-5.8G-3D Page3 Date2024-05-15 VersionA0 ShenzhenXingtongWieressTechnologyCo.,Ltd Documentnumber XT-YF-004 ProductName WIFIstickantenna Productnumber 5. Attacheddiagram: 5.1:AntennaEngineeringDrawing Page4
Page 1 of 34 FCCID: 2AU3Z-VWP300ReportNo. : LCSA06034243EB ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity AppendixB RF Test Data for BT LE (ConductedMeasurement) ProductName:Vivi WirelessPresentation Test Model:VWP-300-16 EnvironmentalConditions Temperature: 23.8C RelativeHumidity:52.1% ATM Pressure: 10 0.0 kPa Test Engineer:PaddiChen Supervisedby: Nick Peng Page 2 of 34 FCCID: 2AU3Z-VWP300ReportNo. : LCSA06034243EB ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity B.1 -6dB Bandwidth ConditionModeFrequency(MHz)Antenna-6 dB Bandwidth(MHz)Limit -6 dB Bandwidth(MHz)Verdict NVNTBLE 1M2402Ant00.681>=0.5Pass NVNTBLE 1M2440Ant00.704>=0.5Pass NVNTBLE 1M2480Ant00.652>=0.5Pass NVNTBLE 2M2402Ant01.122>=0.5Pass NVNTBLE 2M2440Ant01.104>=0.5Pass NVNTBLE 2M2480Ant01.104>=0.5Pass Page 3 of 34 FCCID: 2AU3Z-VWP300ReportNo. : LCSA06034243EB ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity Test Graphs -6dBBandwidthNVNTBLE 1M 2402MHzAnt0 -6dBBandwidthNVNTBLE 1M 2440MHzAnt0 Page 4 of 34 FCCID: 2AU3Z-VWP300ReportNo. : LCSA06034243EB ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity -6dBBandwidthNVNTBLE 1M 2480MHzAnt0 -6dBBandwidthNVNTBLE 2M 2402MHzAnt0 Page 5 of 34 FCCID: 2AU3Z-VWP300ReportNo. : LCSA06034243EB ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity -6dBBandwidthNVNTBLE 2M 2440MHzAnt0 -6dBBandwidthNVNTBLE 2M 2480MHzAnt0 Page 6 of 34 FCCID: 2AU3Z-VWP300ReportNo. : LCSA06034243EB ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity B.2 MaximumConductedOutputPower ConditionModeFrequency(MHz)AntennaConductedPower(dBm)Limit (dBm)Verdict NVNTBLE 1M2402Ant0-0.7830Pass NVNTBLE 1M2440Ant0-0.0730Pass NVNTBLE 1M2480Ant0-0.0530Pass NVNTBLE 2M2402Ant00.530Pass NVNTBLE 2M2440Ant00.0930Pass NVNTBLE 2M2480Ant00.0830Pass Page 7 of 34 FCCID: 2AU3Z-VWP300ReportNo. : LCSA06034243EB ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity Test Graphs PowerNVNTBLE 1M 2402MHzAnt0 PowerNVNTBLE 1M 2440MHzAnt0 Page 8 of 34 FCCID: 2AU3Z-VWP300ReportNo. : LCSA06034243EB ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity PowerNVNTBLE 1M 2480MHzAnt0 PowerNVNTBLE 2M 2402MHzAnt0 Page 9 of 34 FCCID: 2AU3Z-VWP300ReportNo. : LCSA06034243EB ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity PowerNVNTBLE 2M 2440MHzAnt0 PowerNVNTBLE 2M 2480MHzAnt0 Page 10 of 34 FCCID: 2AU3Z-VWP300ReportNo. : LCSA06034243EB ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity B.3 MaximumPowerSpectralDensityLevel ConditionModeFrequency(MHz)AntennaConductedPSD (dBm/3kHz)Limit (dBm/3kHz)Verdict NVNTBLE 1M2402Ant0-13.68Pass NVNTBLE 1M2440Ant0-16.448Pass NVNTBLE 1M2480Ant0-16.458Pass NVNTBLE 2M2402Ant0-16.718Pass NVNTBLE 2M2440Ant0-19.778Pass NVNTBLE 2M2480Ant0-18.458Pass Page 11 of 34 FCCID: 2AU3Z-VWP300ReportNo. : LCSA06034243EB ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity Test Graphs PSD NVNTBLE 1M 2402MHzAnt0 PSD NVNTBLE 1M 2440MHzAnt0 Page 12 of 34 FCCID: 2AU3Z-VWP300ReportNo. : LCSA06034243EB ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity PSD NVNTBLE 1M 2480MHzAnt0 PSD NVNTBLE 2M 2402MHzAnt0 Page 13 of 34 FCCID: 2AU3Z-VWP300ReportNo. : LCSA06034243EB ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity PSD NVNTBLE 2M 2440MHzAnt0 PSD NVNTBLE 2…
Text truncated - open the document above for the full version.
Page 1 of 157 FCCID: 2AU3Z-VWP300ReportNo. : LCSA06034243EC ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity AppendixC RF Test Data for 2.4GWIFI(ConductedMeasurement) ProductName:Vivi WirelessPresentation Test Model:VWP-300-16 EnvironmentalConditions Temperature: 23.8C RelativeHumidity: 52.1% ATM Pressure: 10 0.0 kPa Test Engineer: PaddiChen Supervisedby: Nick Peng Page 2 of 157 FCCID: 2AU3Z-VWP300ReportNo. : LCSA06034243EC ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity C.1 -6dB Bandwidth ConditionModeFrequency(MHz)Antenna-6 dB Bandwidth(MHz)Limit -6 dB Bandwidth(MHz)Verdict NVNTb2412Ant09.559>=0.5Pass NVNTb2437Ant08.467>=0.5Pass NVNTb2462Ant08.09>=0.5Pass NVNTg2412Ant016.278>=0.5Pass NVNTg2437Ant016.34>=0.5Pass NVNTg2462Ant016.326>=0.5Pass NVNTn202412Ant016.025>=0.5Pass NVNTn202437Ant017.284>=0.5Pass NVNTn202462Ant012.713>=0.5Pass NVNTn402422Ant031.652>=0.5Pass NVNTn402437Ant030.673>=0.5Pass NVNTn402452Ant034.196>=0.5Pass NVNTax202412Ant017.61>=0.5Pass NVNTax202437Ant017.567>=0.5Pass NVNTax202462Ant017.804>=0.5Pass NVNTax402422Ant036.295>=0.5Pass NVNTax402437Ant035.533>=0.5Pass NVNTax402452Ant036.04>=0.5Pass Page 3 of 157 FCCID: 2AU3Z-VWP300ReportNo. : LCSA06034243EC ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity Test Graphs -6dBBandwidthNVNTb 2…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 2.41 GHz - 2.46 GHz | 41.00 mW |