
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Wireless Output: 5W/10W FCC statement: This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) this device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: --Reorient or relocate the receiving antenna. --Increase the separation between the equipment and receiver. --Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. --Consult the dealer or an experienced radio/TV technician for help. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Radiation Exposure Statement This device complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. During the operation of device a distance of 15 cm surrounding the device and 20 cm above the top surface of thedevice must be respected.
TennRich International Corp. 1-3, Alley 5, Lane 305, Sec.1, Shin Nan Road, Lu Chu District, Taoyuan City, Taiwan 338 Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2023/09/10 U.S. Agent Designation TennRich International Corp. acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: 2AU4P-PPS300W2): Name and company of U.S. agent: TENNRICH AMERICA, INC. Physical U.S. address of agent: 3333 BREA CANYON RD STE 206, DIAMOND BAR, CA 91765 FRN of U.S. agent: 0034095265 Email address of U.S. agent: [email protected] TENNRICH AMERICA, INC. acknowledges their obligation to accept service of process on behalf of TennRich International Corp. TennRich International Corp. with the FRN [0028973394] accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. Sincerely, Signature Yuna Hung Certification Coordinator TennRich International Corp. Signature Richard Arrata Manager TENNRICH AMERICA, INC. 48_[mo del] US_Agent_2.911(d)(7) - U, V0 5
Sincerely, Name/Title: Yuna Hung/Certification Commissioner Company: TennRich International Corp. Address: 1-3, Alley 5, Lane 305, Sec.1, Shin Nan Road, Lu Chu District, Taoyuan City, Taiwan 338 China Phone: 886-3-3124888-1809 Fax: 886-3-3114771 E-Mail: [email protected]
Shenzhen BANTEK Testing Co., Ltd. Page 1 of 6 Report No.: BTEK230914007AE001 Appendix EUT Photos for BTEK230914007AE001 Shenzhen BANTEK Testing Co., Ltd. Page 2 of 6 Report No.: BTEK230914007AE001 External Shenzhen BANTEK Testing Co., Ltd. Page 3 of 6 Report No.: BTEK230914007AE001 Shenzhen BANTEK Testing Co., Ltd. Page 4 of 6 Report No.: BTEK230914007AE001 Shenzhen BANTEK Testing Co., Ltd. Page 5 of 6 Report No.: BTEK230914007AE001 Shenzhen BANTEK Testing Co., Ltd. Page 6 of 6 Report No.: BTEK230914007AE001
Shenzhen BANTEK Testing Co., Ltd. Page 1 of 2 Report No.: BTEK230914007AE001 LABEL AND LOCATION Shenzhen BANTEK Testing Co., Ltd. Page 2 of 2 Report No.: BTEK230914007AE001 Label Location
Shenzhen BANTEK Testing Co., Ltd. Page 1 of 9 Report No.: BTEK230914007AE001 Appendix EUT Photos for BTEK230914007AE001 Shenzhen BANTEK Testing Co., Ltd. Page 2 of 9 Report No.: BTEK230914007AE001 Internal Shenzhen BANTEK Testing Co., Ltd. Page 3 of 9 Report No.: BTEK230914007AE001 Shenzhen BANTEK Testing Co., Ltd. Page 4 of 9 Report No.: BTEK230914007AE001 Shenzhen BANTEK Testing Co., Ltd. Page 5 of 9 Report No.: BTEK230914007AE001 Coil antenna Shenzhen BANTEK Testing Co., Ltd. Page 6 of 9 Report No.: BTEK230914007AE001 Shenzhen BANTEK Testing Co., Ltd. Page 7 of 9 Report No.: BTEK230914007AE001 Shenzhen BANTEK Testing Co., Ltd. Page 8 of 9 Report No.: BTEK230914007AE001 Shenzhen BANTEK Testing Co., Ltd. Page 9 of 9 Report No.: BTEK230914007AE001
Shenzhen BANTEK Testing Co., Ltd. Page 1 of 11 Report No.: BTEK230914007AE002 RF Exposure Report For Applicant Name: TennRich International Corp. Address: 1-3, Alley 5, Lane 305, Sec.1, Shin Nan Road, Lu Chu District, Taoyuan City, Taiwan 338 EUT Name: Portable Power Station Brand Name: Energizer Model Number: PPS300W2 Series Model Number: Refer to section 2 Issued By Company Name: Shenzhen BANTEK Testing Co., Ltd. Address: A5&A6,Building B1&B2,No.45 Gangtou Road,BoganCommunity, Shajing Street,Bao'an District, Shenzhen,Guangdong,China 518104 Report Number: BTEK230914007AE002 Test Standards: 47 CFR Part 15 Subpart C FCC ID: 2AU4P-PPS300W2 Test Conclusion: Pass Test Date: 2023-09-18 to 2023-09-21 Date of Issue: 2023-09-21 Prepared By: Carl Yang /Project Engineer Date: 2023-09-21 Approved By: Damon Su / EMC Manager Date: 2023-09-21 * In the configuration tested, the EUT complied with the standards specified above. Shenzhen BANTEK Testing Co., Ltd. Page 2 of 11 Report No.: BTEK230914007AE002 Revision History Version Issue Date Revisions Content R_V0 2023-09-21 Original Note: Once the revision has been made, then previous versions reports are invalid. Shenzhen BANTEK Testing Co., Ltd. Page 3 of 11 Report No.: BTEK230914007AE002 Table of Contents 1. Introduction ............................................................................................................................................................................................ 4 1.1 Identification of Testing Laboratory ................................................................................................................................. 4 1.2 Identification of the Responsible Testing Location ...................................................................................................... 4 1.3 Laboratory Condition ........................................................................................................................................................... 4 1.4 Announcement ....................................................................................................................................................................... 4 2. Product Information .............................................................................................................................................................................. 5 2.1 Application Information ....................................................................................................................................................... 5 2.2 Manufacturer Information .................................................................................................................................................... 5 2.3 Factory Information .............................................................................................................................................................. 5 2.4 General Description of Equipment under Test (EUT)................................................................................................... 5 2.5 Technical Information........................................................................................................................................................... 5 3. Test Requirement ................................................................................................................................................................................. 6 1.1 Assessment Result ............................................................................................................................................................... 8 1.1 Test Set-up Photo .................................................................................................................................................................. 9 Shenzhen BANTEK Testing Co., Ltd. Page 4 of 11 Report No.: BTEK230914007AE002 1. Introduction 1.1 Identification of Testing Laboratory Company Name: Shenzhen BANTEK Testing Co., Ltd. Address: A5&A6,Building B1&B2,No.45 Gangtou Road,BoganCommunity, Shajing Street,Bao'an District, Shenzhen,Guangdong,China 518104 Phone Number: +86(755) 2334 4200 Fax Number: +86(755) 2334 4200 1.2 Identification of the Responsible Testing Location Test Location: Shenzhen BANTEK Testing Co., Ltd. Address: A5&A6,Building B1&B2,No.45 Gangtou Road,BoganCommunity, Shajing Street,Bao'an District, Shenzhen,Guangdong,China 518104 Description: All measurement facilities used to collect the measurement data are located at A5&A6,Building B1&B2,No.45 Gangtou Road,BoganCommunity, Shajing Street,Bao'an District, Shenzhen,Guangdong,China 518104 FCC Registration Number: 264293 Designation Number: CN1356 1.3 Laboratory Condition Ambient Temperature: 20°C to 25°C Ambient Relative Humidity: 45% to 55% Ambient Pressure: 100 kPa to 102 kPa 1.4 Announcement (1) The test report is invalid if not marked with the signatures of the persons responsible for preparing, reviewing and approving the test report. (2) This document may not be altered or revised in any way unless done so by BANTEK and all revisions are duly noted in the revisions section. (3) Content of the test report, in part or in full, cannot be used for publicity and/or promotional purposes without prior written approval from the laboratory. (4) The laboratory is only responsible for the data released by the laboratory, except for the part provided by the applicant. Shenzhen BANTEK Testing Co., Ltd. Page 5 of 11 Report No.: BTEK230914007AE002 2. Product Information 2.1 Application Information Company Name: TennRich International Corp. Address: 1-3, Alley 5, Lane 305, Sec.1, Shin Nan Road, Lu Chu District, Taoyuan City, Taiwan 338 2.2 Manufacturer Information Company Name: Shenzhen Newman Hyde Intelligent Technology Co., Ltd Address: 902, No.2500106,JunXin Road, Niuhu Community, Guanlan Street, Longhua District, Shenzhen(9F, building A,Xinlida Industrial Park) 2.3 Factory Information Company Name: Shenzhen Newman Hyde I…
Text truncated - open the document above for the full version.
FWC series ( Rev. 5.0 ) Features & Applications * Wireless charging coil * High permeability shielding for wireless charging receiving coils * High saturation powered iron - not affected by permanent locating magnets * Blocks charging flux from sensitive components or batteries * Durable construction Product IdentificationOperating & Storage Condition : * Operating Temp. : -55 to +85°C --* Storage Temp. : -25 to +35°C 1 * Storage Life Time : 12 Month @25°C , RH 70% * Ambient Temp : 20±15°C * Relative Humidity : 65±20% 5. [A-Z]: For Customized Design. * Inductance Test Condition: 100KHz/ 1.0V. FWC-T5035-001K6.3±10%55.0 max.60.0 min. Q G(±0.5) Model Inductance (uH) DCR (mΩ) E(±0.5)F(typ.) 503520.542.050.0 1. Product Code: FWC H(±0.2) 1.03.55.313.02.0 Size CodeA(±0.5)B(±2.0) 23 45 C(±0.5)D(±0.5) 2. [T]-Tx. 3. Size Code 4. Series No. : 001 Dimensions[mm] Standard Atmospheric Conditions : Front ViewSide View FWCT5035001K SPECIFICATION WIRELESS CHARGING COIL http://www.gyfsz.com 深圳市格亚飞科技有限公司 Shenzhen GYF Technology Co.,Ltd. tape tearing tab coil double-sided adhesive Gain 0 dBi. Ant Type: Loop coil Antenna
Shenzhen BANTEK Testing Co., Ltd. Page 1 of 30 Report No.: BTEK230914007AE001 Test Report Applicant Name: TennRich International Corp. Address: 1-3, Alley 5, Lane 305, Sec.1, Shin Nan Road, Lu Chu District, Taoyuan City, Taiwan 338 EUT Name: Portable Power Station Brand Name: Energizer Model Number: PPS300W2 Series Model Number: Refer to section 2 Issued By Company Name: Shenzhen BANTEK Testing Co., Ltd. Address: A5&A6,Building B1&B2,No.45 Gangtou Road,BoganCommunity, Shajing Street,Bao'an District, Shenzhen,Guangdong,China 518104 Report Number: BTEK230914007AE001 Test Standards: 47 CFR Part 15 Subpart C FCC ID: 2AU4P-PPS300W2 Test Conclusion: Pass Test Date: 2023-09-18 to 2023-09-21 Date of Issue: 2023-09-21 Prepared By: Carl Yang /Project Engineer Date: 2023-09-21 Approved By: Damon Su / EMC Manager Date: 2023-09-21 * In the configuration tested, the EUT complied with the standards specified above. Shenzhen BANTEK Testing Co., Ltd. Page 2 of 30 Report No.: BTEK230914007AE001 Revision History Version Issue Date Revisions Content R_V0 2023-09-21 Original Note: Once the revision has been made, then previous versions reports are invalid. Shenzhen BANTEK Testing Co., Ltd. Page 3 of 30 Report No.: BTEK230914007AE001 Table of Contents 1. Introduction ............................................................................................................................................................................................ 4 1.1 Identification of Testing Laboratory ................................................................................................................................. 4 1.2 Identification of the Responsible Testing Location ...................................................................................................... 4 1.3 Laboratory Condition ........................................................................................................................................................... 4 1.4 Announcement ....................................................................................................................................................................... 4 2. Product Information .............................................................................................................................................................................. 5 2.1 Application Information ....................................................................................................................................................... 5 2.2 Manufacturer Information .................................................................................................................................................... 5 2.3 Factory Information .............................................................................................................................................................. 5 2.4 General Description of Equipment under Test (EUT)................................................................................................... 5 2.5 Technical Information........................................................................................................................................................... 6 3. Summary of Test Results .................................................................................................................................................................... 7 3.1 Test Standards ....................................................................................................................................................................... 7 3.2 Summary of Test Result ...................................................................................................................................................... 7 3.3 Uncertainty of Test ................................................................................................................................................................ 7 4. Test Configuration ................................................................................................................................................................................ 9 4.1 Environment Condition ........................................................................................................................................................ 9 4.2 Test Equipment List .............................................................................................................................................................. 9 4.3 Test Auxiliary Equipment .................................................................................................................................................. 10 4.4 Test Setup ............................................................................................................................................................................. 11 5. Test Items ............................................................................................................................................................................................ 13 5.1 Antenna Requirements ...................................................................................................................................................... 13 5.2 20dB Occupied Bandwidth ............................................................................................................................................... 14 5.3 AC Power Line Conducted Emissions ........................................................................................................................... 15 5.4 Radiated Spurious Emission ............................................................................................................................................ 16 ANNEX A Test Results ..................................................................................................................................................…
Text truncated - open the document above for the full version.
Shenzhen BANTEK Testing Co., Ltd. Page 1 of 3 Report No.: BTEK230914007AE001 Appendix Setup Photos for BTEK230914007AE001 Shenzhen BANTEK Testing Co., Ltd. Page 2 of 3 Report No.: BTEK230914007AE001 Radiated Emissions Radiated Emissions Shenzhen BANTEK Testing Co., Ltd. Page 3 of 3 Report No.: BTEK230914007AE001 Power Line Conducted Emissions
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.11 MHz - 0.205 MHz | - |

Power Bank
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Power Bank
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Magnetic Wireless Car Charger
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Power bank
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Power bank
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz