Application Details

Equipment Class
PCB - PCS Licensed Transmitter
Date of Grant
Jan 16, 2020
Application Purpose
Original Equipment
Date of Application
Jan 16, 2020
Equipment Note
Multifunctional intelligent cabinet
Frequency Range
699.70000000 - 715.30000000
Company
SUZHOU DUSIT TECHNOLOGY CO., LTD
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Parts List/Tune Up Info

↗

RF Exposure Info

↗

Schematics

↗

Test Report

↗
↗
↗
↗
↗
↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

UniversalFunctionsSmartLocker MANUALS PART-1Administrator’soperations (Lockerregistration&Testing) 1.1MainMenuofUniversalLocker 1.2AdministratorLogin 1.2.1EQUIPMENTREGISTRATIN 1.2.2EQUIPMENTTESTING PART-2Couriers’Operations (Courierregistration&Drop-off) 2.1CourierRegistrationonlocker’sscreen 2.2CourierDrop-offProcedures 2.2.1Courierdropoff 2.2.2Lockerboxtypeselection 2.2.3InputRecipientInformation PART-3Recipient’sOperations (PickUp) 3.1Pick-upprocedures 3.2KeyReturning PART-1Administrator’soperations (Lockerregistration&testing) 1.1MainMenuofUniversalLocker: 1.2AdministratorLogin Press buttonatbottomrightcorner,inputServicecode(BM),Useraccount,Password,pressNEXTlogin. Mainmenusdisplayingafterloginsuccessfully: 1.2.1EQUIPMENTREGISTRATIN:inputtheLockerID 1.2.2EQUIPMENTTESTING:checkallelectroniclocks(lockerdoors)status PART-2Couriers’Operations (RegistrationandDrop-off) 2.1CourierRegistrationonlocker’sscreen: Press buttonatbottomrightcorner,userregistrationtableshown,therearethreeroles:Courier/Deliverystaff/ Propertymanager.Usersneedtoinputmobilephonenumberandverificationcode,aswellassettingtheirownaccountnameand password. 2.2CourierDrop-offProcedures: 2.2.1Courierpress button,Logininterfacedisplayingasbelow: 2.2.2Users(courier/deliverystaff/propertymanager)selectlockerboxtype/quantityanddropoff: 2.2.3CourierpressINPUTbutton: InputtheRecipientinformation(ParcelNumber,Recipient’smobilephonenumber) AfterSUBMITALLinformation,thePINcodehasbeensenttoRecipient’smobilephonethroughSMS. PART-3Recipient’sOperations (PickUp) 3.1Pick-upProcedures: Pressbutton , CheckPINcodeoutthroughSMS, EnterPINcode: Lockerdooropenautomaticallyandtakeparceloutandcloselockerdoor,Pick-upfinished. 3.2KeyReturning: Pressbutton,KeyReturnshownup: Scanorenterthebar-codeornumberofthekey,lockerboxopenanddropoffkeyandclosethedoor,meanwhile,thePINcode wouldbesenttoPropertymanager’smobilephone. Technical description: Frequency Range: LTE Band 2, Band 4, Band 7, Band 12 Transmit Power: 24 dBm Antenna Type:External antenna Antenna Gain:0 dBi FCC Statement: This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) this device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: --Reorient or relocate the receiving antenna. --Increase the separation between the equipment and receiver. --Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. --Consult the dealer or an experienced radio/TV technician for help. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC Radiation Exposure Statement This device complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This device must operate with a minimum distance of 50mm between the radiator and user body. IC Statement This device complies with Industry Canada's licence-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause interference; and (2) This device must accept any interference, including interference that may cause undesired operation of the device. Cet appareil est conforme aux CNR exemptes de licence d'Industrie Canada . Son fonctionnement est soumis aux deux conditions suivantes : (1) Ce dispositif ne peut causer d'interfĂ©rences ; et (2) Ce dispositif doit accepter toute interfĂ©rence , y compris les interfĂ©rences qui peuvent causer un mauvais fonctionnement de l'appareil. This device must operate with a minimum distance of 50mm between the radiator and user body.

Cover Letter(s)

CONFIDENTIALITY REQUEST for Certification Service in USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21046 Date: 2019/11/26 TO WHOM IT MAY CONCERN Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we requests confidentiality for the following products: FCC ID Model name 2AU8G-UC1901 UC1901 For the product stated above, we request that the following information be held confidential; Exhibits Long-Term Confidentiality Short-Term Confidentiality Short-Term Confidentiality Days External Photos Internal Photos Block Diagram Schematics Test Setup Photos User’s Manual Parts List Tune Up Operational Descriptions The long-term confidentiality exhibits contain our trade secrets and proprietary information that could be of benefit to our competitors. The short-term confidentiality on the basis of ensuring that business sensitive information remains confidential until the actual marketing of our new device. If you have any questions, please feel free to contact me at the address shown below. Sincerely, Name: XU YIJUN Company: SUZHOU DUSIT TECHNOLOGY CO., LTD Address: NO.289 SOUTH YINZHONG RD, WUZHONG ECONOMIC DISTRICT, SUZHOU, CHINA Phone: +86-18662246255 Fax: N/A E-Mail: [email protected]

Cover Letter(s)

SUZHOU DUSIT TECHNOLOGY CO., LTD NO.289 SOUTH YINZHONG RD, WUZHONG ECONOMIC DISTRICT, SUZHOU, CHINA Tel: +86-18662246255 Fax: N/A Nov. 26, 2019 FCC ID: 2AU8G-UC1901 Dear Sir, I hereby have entrusted the following person to be a proxy regarding application for Type Certification. Shenzhen CTL Testing Technology Co., Ltd. Address: Floor 1-A, Baisha Technology Park, No.3011, Shahexi Road, Nanshan District, Shenzhen, China 518055 Name: Tracy Qi Job Title:Manager Email: qihui@ctl‐lab.com I am therefore responsible for the contents of the application. Model Name of the specified radio equipment: UC1901 FCC ID: 2AU8G-UC1901 Product DescriptionғMultifunctional intelligent cabinet Should you have any questions or comments regarding this matter, please have my best attention. Sincerely, Name:XU YIJUN Company: SUZHOU DUSIT TECHNOLOGY CO., LTD Address:NO.289 SOUTH YINZHONG RD, WUZHONG ECONOMIC DISTRICT, SUZHOU, CHINA Phone: +86-18662246255 Fax: N/A E-Mail: [email protected] Xu YJUN

ID Label/Location Info

FCC ID Label Information 1. Label location: 2. FCC ID Label: Multifunctional intelligent cabinet Model: UC1901 FCC ID:2AU8G‐UC1901 IC:25685‐UC1901 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Label Size:120mm(L)×60mm(W) FCCID Label Location

Parts List/Tune Up Info

Tune Up Procedure During manufacturing each device is individually calibrated. Measurement is performed in a fully calibrated setup using an CMW500 base station simulator (system tester). Measurement procedure is outlined below: Measurement Procedure: 1. Set the device to operational voltage and on a predefined channel in a special test mode. 2. The actual output power is measured at several power levels. 3. The gain factors of each individual device are adjusted until the target value is met. The appropriate gain control settings for each output power level are stored in each device individually (for each power level). The user has no possibility to change these settings later on. 4. The maximum gains of each individual device are adjusted and measured until the target value is met. The production target power with tolerance compiles with the maximum power in test report. 5. The Maximum PK or AV target power as below. Target Power for LTE Band 2 23±1 dBm Band 4 23±1 dBm Band 7 23±1 dBm Band 12 23±1 dBm Then these appropriate gain settings are stored in each device individually. The user has no possibility to change these settings later on, and during manufacturing each device will be individual calibrated in this range. The measurement is done in a fully calibrated setup, which is based on the base station simulator. Furthermore, the highest power level is verified afterwards in a call measurement on three channels (low, middle and high).

RF Exposure Info

RF Exposure evaluation FCC ID: 2AU8G-UC1901 According to 447498 D01 General RF Exposure Guidance v05 The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≀ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√f(GHz)] ≀ 3.0 for 1-g SAR and ≀ 7.5 for 10-g extremity SAR, where f(GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation The result is rounded to one decimal place for comparison Extremity condition: The minmum separation distance is 50 mm: For band 2 pt=23.69dBm =233.9mW at 1860MHz So (233.9mW/50mm)x √1. 86GHz =6.38<7.5 For band 4 pt=23.02dBm =200.4mW at 1710.7MHz So (200.4mW/50mm)x √1. 7107GHz =5.24<7.5 For band 7 pt=23.34dBm =215.8mW at 2535MHz So (215.8mW/50mm)x √2. 535GHz =6.87<7.5 For band 12 pt=23.47dBm =222.3mW at 699.7MHz Antenna Screen So (222.3mW/50mm)x √699.7GHz =3.72<7.5 Then SAR evaluation is not required

Schematics

Shenzhen CTL Testing Technology Co., Ltd. Tel: +86-755-89486194 E-mail: [email protected] TEST REPORT FCC Part 27/ RSS-199 Report Reference No. ................ : CTL1907151031-WF03 Compiled by: ( position+printed name+signature) Happy Guo (File administrators) Tested by: ( position+printed name+signature) Nice Nong (Test Engineer) Approved by: ( position+printed name+signature) Ivan Xie (Manager) Product Name ............................ : Multifunctional intelligent cabinet Model/Type reference ................ : UC1901 List Model(s) ............................... : N/A Trade Mark .................................. : N/A FCC ID ......................................... : 2AU8G-UC1901 IC ................................................. : 25685-UC1901 Applicant’s name ....................... : SUZHOU DUSIT TECHNOLOGY CO., LTD Address of applicant ................. : NO.289 SOUTH YINZHONG RD, WUZHONG ECONOMIC DISTRICT, SUZHOU, CHINA Test Firm ..................................... : Shenzhen CTL Testing Technology Co., Ltd. Address of Test Firm ................. : Floor 1-A, Baisha Technology Park, No.3011, Shahexi Road, Nanshan District, Shenzhen, China 518055 Test specification ....................... : Standard ...................................... : FCC CFR Title 47 Part 2, Part 27 EIA/TIA 603-D: 2010 KDB 971168 D01 RSS-199 Issue 3 December 2016 TRF Originator ............................. : Shenzhen CTL Testing Technology Co., Ltd. Master TRF .................................. : Dated 2011-01 Date of receipt of test item ........ : Jul. 20, 2019 Date of sampling ........................ : Jul. 20, 2019 Date of Test Date ........................ : Jul. 20, 2019–Sep. 28, 2019 Data of Issue............................... : Sep. 29, 2019 Result .......................................... : Pass Shenzhen CTL Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen CTL Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTL Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. V1.0 Page 2 of 50 Report No.: CTL1907151031-WF03 TEST REPORT Test Report No. : CTL1907151031-WF03 Sep. 29, 2019 Date of issue Equipment under Test : Multifunctional intelligent cabinet Model /Type : UC1901 Listed Models : N/A Applicant : SUZHOU DUSIT TECHNOLOGY CO., LTD Address : NO.289 SOUTH YINZHONG RD, WUZHONG ECONOMIC DISTRICT, SUZHOU, CHINA Manufacturer : SUZHOU DUSIT TECHNOLOGY CO., LTD Address : NO.289 SOUTH YINZHONG RD, WUZHONG ECONOMIC DISTRICT, SUZHOU, CHINA Test result Pass * *In the configuration tested, the EUT complied with the standards specified page 5. The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the issuing testing laboratory. V1.0 Page 3 of 50 Report No.: CTL1907151031-WF03 ** Modified History ** Revisions Description Issued Data Report No. Remark Version 1.0 Initial Test Report Release 2019-09-29 CTL1907151031-WF03 Tracy Qi V1.0 Page 4 of 50 Report No.: CTL1907151031-WF03 Table of Contents Page 1. SUMMARY ............................................................................................................................................................... 5 1.1. TEST STANDARDS ..................................................................................................................................................... 5 1.2. TEST DESCRIPTION ........................................................................................................................................................ 5 1.3. TEST FACILITY .............................................................................................................................................................. 6 1.4. STATEMENT OF THE MEASUREMENT UNCERTAINTY ............................................................................................................... 6 2. GENERAL INFORMATION .......................................................................................................................................... 7 2.1. ENVIRONMENTAL CONDITIONS ........................................................................................................................................ 7 2.2. GENERAL DESCRIPTION OF EUT ...................................................................................................................................... 7 2.3. DESCRIPTION OF TEST MODES ........................................................................................................................................ 7 2.4. EQUIPMENTS USED DURING THE TEST .............................................................................................................................. 7 2.5. RELATED SUBMITTAL(S) / GRANT (S) ................................................................................................................................ 8 2.6. MODIFICATIONS ........................................................................................................................................................... 8 3. TEST CONDITIONS AND RESULTS .............................................................................................................................. 9 3.1. OUTPUT POWER .......................................................................................................................................................... 9 3.2. PEAK-TO-AVERAGE RATIO (PAR) ................................................................................................................................... 15 3.3. OCCUPIED BANDWIDTH AND EMISSION BANDWIDTH .....................................................


Text truncated - open the document above for the full version.

Test Report

Shenzhen CTL Testing Technology Co., Ltd. Tel: +86-755-89486194 E-mail: [email protected] TEST REPORT FCC Part 24 Subpart E/ RSS-133 Report Reference No. ................ : CTL1907151031-WF01 Compiled by: ( position+printed name+signature) Happy Guo (File administrators) Tested by: ( position+printed name+signature) Nice Nong (Test Engineer)  Approved by: ( position+printed name+signature) Ivan Xie (Manager) Product Name ............................ : Multifunctional intelligent cabinet Model/Type reference ................ : UC1901 List Model(s) ............................... : N/A Trade Mark .................................. : N/A FCC ID ......................................... : 2AU8G-UC1901 IC ................................................. : 25685-UC1901 Applicant’s name ....................... : SUZHOU DUSIT TECHNOLOGY CO., LTD Address of applicant ................. : NO.289 SOUTH YINZHONG RD, WUZHONG ECONOMIC DISTRICT, SUZHOU, CHINA Test Firm ..................................... : Shenzhen CTL Testing Technology Co., Ltd. Address of Test Firm ................. : Floor 1-A, Baisha Technology Park, No.3011, Shahexi Road, Nanshan District, Shenzhen, China 518055 Test specification ....................... : Standard ...................................... : FCC CFR Title 47 Part 2, Part 24E EIA/TIA 603 -D: 2010 KDB 971168 D01 RSS-133 issue 6 January 2018 TRF Originator ............................. : Shenzhen CTL Testing Technology Co., Ltd. Master TRF .................................. : Dated 2011-01 Date of receipt of test item ........ : Jul. 20, 2019 Date of sampling ........................ : Jul. 20, 2019 Date of Test Date ........................ : Jul. 20, 2019–Sep. 28, 2019 Data of Issue............................... : Sep. 29, 2019 Result .......................................... : Pass Shenzhen CTL Testing Technology Co., Ltd. All rights reserved. This publica tion may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen CTL Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTL Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. V1.0 Page 2 of 70 Report No.: CTL1907151031-WF01 TEST REPORT Test Report No. : CTL1907151031-WF01 Sep. 29, 2019 Date of issue Equipment under Test : Multifunctional intelligent cabinet Model /Type : UC1901 Listed Models : N/A Applicant : SUZHOU DUSIT TECHNOLOGY CO., LTD Address : NO.289 SOUTH YINZHONG RD, WUZHONG ECONOMIC DISTRICT, SUZHOU, CHINA Manufacturer : SUZHOU DUSIT TECHNOLOGY CO., LTD Address : NO.289 SOUTH YINZHONG RD, WUZHONG ECONOMIC DISTRICT, SUZHOU, CHINA Test result Pass * In the configuration tested, the EUT complied with the standards specified page 5. The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the issuing testing laboratory. V1.0 Page 3 of 70 Report No.: CTL1907151031-WF01 ** Modified History ** Revisions Description Issued Data Report No. Remark Version 1.0 Initial Test Report Release 2019-09-29 CTL1907151031-WF01 Tracy Qi V1.0 Page 4 of 70 Report No.: CTL1907151031-WF01 Table of Contents Page 1. SUMMARY ............................................................................................................................................................... 5 1.1. TEST STANDARDS ..................................................................................................................................................... 5 1.2. TEST DESCRIPTION ........................................................................................................................................................ 5 1.3. TEST FACILITY .............................................................................................................................................................. 6 1.4. STATEMENT OF THE MEASUREMENT UNCERTAINTY ............................................................................................................... 6 2. GENERAL INFORMATION .......................................................................................................................................... 7 2.1. ENVIRONMENTAL CONDITIONS ........................................................................................................................................ 7 2.2. GENERAL DESCRIPTION OF EUT ...................................................................................................................................... 7 2.3. DESCRIPTION OF TEST MODES ........................................................................................................................................ 7 2.4. EQUIPMENTS USED DURING THE TEST .............................................................................................................................. 7 2.5. RELATED SUBMITTAL(S) / GRANT (S) ................................................................................................................................ 8 2.6. MODIFICATIONS ........................................................................................................................................................... 8 3. TEST CONDITIONS AND RESULTS .............................................................................................................................. 9 3.1. OUTPUT POWER .......................................................................................................................................................... 9 3.2. PEAK-TO-AVERAGE RATIO (PAR) ................................................................................................................................... 16 3.3. OCCUPIED BANDWIDTH AND EMISSION BANDWIDTH ........................................


Text truncated - open the document above for the full version.

Test Report

V1.0 Page 33 of 70 Report No.: CTL1907151031-WF01 LTE FDD Band 2-3MHz Channel Bandwidth Band Edge Compliance QPSK 16QAM 1RB#0 1RB#0 Low Channel 1RB#0 1RB#0 High Channel V1.0 Page 34 of 70 Report No.: CTL1907151031-WF01 LTE FDD Band 2-5MHz Channel Bandwidth Band Edge Compliance QPSK 16QAM 1RB#0 1RB#0 Low Channel 1RB#0 1RB#0 High Channel V1.0 Page 35 of 70 Report No.: CTL1907151031-WF01 LTE FDD Band 2-10MHz Channel Bandwidth Band Edge Compliance QPSK 16QAM 1RB#0 1RB#0 Low Channel 1RB#0 1RB#0 High Channel V1.0 Page 36 of 70 Report No.: CTL1907151031-WF01 LTE FDD Band 2-15MHz Channel Bandwidth Band Edge Compliance QPSK 16QAM 1RB#0 1RB#0 Low Channel 1RB#0 1RB#0 High Channel V1.0 Page 37 of 70 Report No.: CTL1907151031-WF01 LTE FDD Band 2-20MHz Channel Bandwidth Band Edge Compliance QPSK 16QAM 1RB#0 1RB#0 Low Channel 1RB#0 1RB#0 High Channel V1.0 Page 38 of 70 Report No.: CTL1907151031-WF01 3.5. Spurious Emission LIMIT Per FCC §24.238, the power of any emission outside of the authorized operating frequency ranges must be attenuated below the transmitting power (P) by a factor of at least 43 + 10log(P) dB. TEST CONFIGURATION Conducted Spurious Measurement: Radiated Spurious Measurement: TEST PROCEDURE The EUT was setup according to EIA/TIA 603D Conducted Spurious Measurement: a. Place the EUT on a bench and set it in transmitting mode. b. Connect a low loss RF cable from the antenna port to a spectrum analyzer and CMW500 by a Directional Couple. c. EUT Communicate with CMW500 then selects a channel for testing. d. Add a correction factor to the display of spectrum, and then test. e. The resolution bandwidth of the spectrum analyzer was set sufficient scans were taken to show the out of band Emission if any up to10th harmonic. V1.0 Page 39 of 70 Report No.: CTL1907151031-WF01 Radiated Spurious Measurement: a. The EUT shall be placed at the specified height on a support, and in the position closest to normal use as declared by provider. b. The test antenna shall be oriented initially for vertical polarization and shall be chosen to correspond to the frequency of the transmitter c. The output of the test antenna shall be connected to the measuring receiver. d. The transmitter shall be switched on and the measuring receiver shall be tuned to the frequency of the transmitter under test. e. The test antenna shall be raised and lowered through the specified range of height until a maximum signal level is detected by the measuring receiver. f. The transmitter shall then be rotated through 360ein the horizontal plane, until the maximum signal level is detected by the measuring receiver. g. The test antenna shall be raised and lowered again through the specified range of height until a maximum signal level is detected by the measuring receiver. h. The maximum signal level detected by the measuring receiver shall be noted. i. The transmitter shall be replaced by a substitution antenna. j. The substitution antenna shall be orientated for vertical polarization and the length of the substitution antenna shall be adjusted to correspond to the frequency of the transmitter. k. The substitution antenna shall be connected to a calibrated signal generator. l. If necessary, the input attenuator setting of the measuring receiver shall be adjusted in order to increase the sensitivity of the measuring receiver. m. The test antenna shall be raised and lowered through the specified range of height to ensure that the maximum signal is received. n. The input signal to the substitution antenna shall be adjusted to the level that produces a level detected by the measuring receiver, that is equal to the level noted while the transmitter radiated power was measured, corrected for the change of input attenuator setting of the measuring receiver. o. The measurement shall be repeated with the test antenna and the substitution antenna orientated for horizontal polarization. p. The measure of the effective radiated power is the larger of the two levels recorded at the input to the substitution antenna, corrected for gain of the substitution antenna if necessary. q. The resolution bandwidth of the spectrum analyzer was set at 100 kHz for Part 22 and 1MHz for Part 24. The frequency range was checked up to 10th harmonic. r. Test site anechoic chamber refer to ANSI C63. TEST RESULTS Remark: 1. We were tested all RB Configuration refer 3GPP TS136 521 for each Channel Bandwidth of LTE FDD Band 2; recorded worst case for each Channel Bandwidth of LTE FDD Band 2. V1.0 Page 40 of 70 Report No.: CTL1907151031-WF01 Conducted Measurement: LTE FDD Band 2-1.4MHz Channel Bandwidth Low Channel QPSK 16QAM 9KHz~150KHz 9KHz~150KHz 150KHz~30MHz 150KHz~30MHz 30MHz~26.5GHz 30MHz~26.5GHz 1RB#0 1RB#0 V1.0 Page 41 of 70 Report No.: CTL1907151031-WF01 LTE FDD Band 2-1.4MHz Channel Bandwidth Middle Channel QPSK 16QAM 9KHz~150KHz 9KHz~150KHz 150KHz~30MHz 150KHz~30MHz 30MHz~26.5GHz 30MHz~26.5GHz 1RB#0 1RB#0 V1.0 Page 42 of 70 Report No.: CTL1907151031-WF01 LTE FDD Band 2-1.4MHz Channel Bandwidth High Channel QPSK 16QAM 9KHz~150KHz 9KHz~150KHz 150KHz~30MHz 150KHz~30MHz 30MHz~26.5GHz 30MHz~26.5GHz 1RB#0 1RB#0 V1.0 Page 43 of 70 Report No.: CTL1907151031-WF01 LTE FDD Band 2-3MHz Channel Bandwidth Low Channel QPSK 16QAM 9KHz~150KHz 9KHz~150KHz 150KHz~30MHz 150KHz~30MHz 30MHz~26.5GHz 30MHz~26.5GHz 1RB#0 1RB#0 V1.0 Page 44 of 70 Report No.: CTL1907151031-WF01 LTE FDD Band 2-3MHz Channel Bandwidth Middle Channel QPSK 16QAM 9KHz~150KHz 9KHz~150KHz 150KHz~30MHz 150KHz~30MHz 30MHz~26.5GHz 30MHz~26.5GHz 1RB#0 1RB#0 V1.0 Page 45 of 70 Report No.: CTL1907151031-WF01 LTE FDD Band 2-3MHz Channel Bandwidth High Channel QPSK 16QAM 9KHz~150KHz 9KHz~150KHz 150KHz~30MHz 150KHz~30MHz 30MHz~26.5GHz 30MHz~26.5GHz 1RB#0 1RB#0 V1.0 Page 46 of 70 Report No.: CTL1907151031-WF01 LTE FDD Band 2-5MHz Channel Bandwidth Low Channel QPSK 16QAM 9KHz~150KHz 9KHz~150KHz 150KHz~30MHz 150KHz~30MHz 30MHz~26.5GHz 30MHz~26.5GHz 1RB#0 1RB#0 V1.0 Page 47 of 70 Report No.: CTL1907151031-WF01 LTE FDD Ba


Text truncated - open the document above for the full version.

Test Report

V1.0 Page 51 of 70 Report No.: CTL1907151031-WF01 LTE FDD Band 2-10MHz Channel Bandwidth High Channel QPSK 16QAM 9KHz~150KHz 9KHz~150KHz 150KHz~30MHz 150KHz~30MHz 30MHz~26.5GHz 30MHz~26.5GHz 1RB#0 1RB#0 V1.0 Page 52 of 70 Report No.: CTL1907151031-WF01 LTE FDD Band 2-15MHz Channel Bandwidth Low Channel QPSK 16QAM 9KHz~150KHz 9KHz~150KHz 150KHz~30MHz 150KHz~30MHz 30MHz~26.5GHz 30MHz~26.5GHz 1RB#0 1RB#0 V1.0 Page 53 of 70 Report No.: CTL1907151031-WF01 LTE FDD Band 2-15MHz Channel Bandwidth Middle Channel QPSK 16QAM 9KHz~150KHz 9KHz~150KHz 150KHz~30MHz 150KHz~30MHz 30MHz~26.5GHz 30MHz~26.5GHz 1RB#0 1RB#0 V1.0 Page 54 of 70 Report No.: CTL1907151031-WF01 LTE FDD Band 2-15MHz Channel Bandwidth High Channel QPSK 16QAM 9KHz~150KHz 9KHz~150KHz 150KHz~30MHz 150KHz~30MHz 30MHz~26.5GHz 30MHz~26.5GHz 1RB#0 1RB#0 V1.0 Page 55 of 70 Report No.: CTL1907151031-WF01 LTE FDD Band 2-20MHz Channel Bandwidth Low Channel QPSK 16QAM 9KHz~150KHz 9KHz~150KHz 150KHz~30MHz 150KHz~30MHz 30MHz~26.5GHz 30MHz~26.5GHz 1RB#0 1RB#0 V1.0 Page 56 of 70 Report No.: CTL1907151031-WF01 LTE FDD Band 2-20MHz Channel Bandwidth Middle Channel QPSK 16QAM 9KHz~150KHz 9KHz~150KHz 150KHz~30MHz 150KHz~30MHz 30MHz~26.5GHz 30MHz~26.5GHz 1RB#0 1RB#0 V1.0 Page 57 of 70 Report No.: CTL1907151031-WF01 LTE FDD Band 2-20MHz Channel Bandwidth High Channel QPSK 16QAM 9KHz~150KHz 9KHz~150KHz 150KHz~30MHz 150KHz~30MHz 30MHz~26.5GHz 30MHz~26.5GHz 1RB#0 1RB#0 V1.0 Page 58 of 70 Report No.: CTL1907151031-WF01 Radiated Measurement: Remark: 1. We were tested all RB Configuration refer 3GPP TS136 521 for each Channel Bandwidth of LTE FDD Band 2; recorded worst case for each Channel Bandwidth of LTE FDD Band 2 @ QPSK 2. EIRP=P Mea (dBm)-P cl (dB) +G a (dBi) 3. We were not recorded other points as values lower than limits. 4. Margin = Limit - EIRP LTE FDD Band 2_Channel Bandwidth 1.4MHz_QPSK_ Low Channel Frequency (MHz) P Mea (dBm) P cl (dB) Distance (m) G a Antenna Gain(dB) Peak EIRP (dBm) Limit (dBm) Margin (dB) Polarization 3701.4 -33.44 4.25 3.00 12.34 -25.35 -13.00 12.35 H 5552.1 -39.62 4.97 3.00 13.52 -31.07 -13.


Text truncated - open the document above for the full version.

Contact Information

Applicant

XU YIJUN
[email protected]+86-18662246255Fax: +86-18662246255

Test Firm

Shenzhen CTL Testing Technology Co., Ltd.Tracy Qi
[email protected]86-755-89486194

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
427699.7 MHz - 715.3 MHz222.33 mW8M93F1D0.013 ppm
Confidentiality
Long Term
Grant Notes
Power listed is conducted. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.