Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Made in China Fabriqué en Chine Hecho en China Residential use only Usage résidentiel seulement Uso residencial solamente Indoor use only Usage intérieur seulement Uso interiores solamente LED table lamp - Swirl Butterfly TM INSTRUCTION MANUAL IMPORTANT: READ CAREFULLY AND KEEP. Lampe de table à DEL - Swirl Butterfly MC MANUEL D’INSTRUCTIONS IMPORTANT : À LIRE ATTENTIVEMENT ET À CONSERVER. Lámpara de mesa LED - Swir Butterfly l MR MANUAL DE INSTRUCCIONES IMPORTANTE: LEER DETENIDAMENTE Y CONSERVAR. Rev. 07-06-2023 ITM. / ART. 1009900714 Model / Modèle / Modelo: TL-SB-HD2CR Imported by /Importé par /Importado por: Home Depot U.S.A., Inc. 2455 Paces Ferry Rd., NW Atlanta, GA 30339 For assistance, call / Pour assistance, appeler / Si necesita ayuda, llame al: 1-877-527-0313 www.homedepot.com 2 ITEM PIÈCE PIEZA DESCRIPTION DESCRIPTION DESCRIPCIÓN QUANTITY QUANTITÉ CANTIDAD A LED table lamp Lampe de table à DEL Lámpara de mesa LED × 1 B Power adapter Bloc d'alimentation mural Adaptador de corriente mural × 1 INCLUDED HARDWARE MATÉRIEL INCLUS HERRAMIENTAS INCLUIDO 3 STEP-BY-STEP INSTALLATION INSTALLATION DÉTAILLÉE INSTALACIÓN ETAPA POR ETAPA 1 AB 4 WARNING: Risk of electrical shock. Turn off breaker at the panel. Switch off the main electrical supply from the fuse box/ circuit breaker before installing the unit or doing any maintenance. Do not use outdoor. AVERTISSEMENT: Risque de décharge électrique. Éteindre le disjoncteur sur le panneau électrique. Il est important de couper l’alimentation électrique du disjoncteur avant de procéder à l’installation ou à l’entretien. Ne pas utiliser à l’extérieur. ADVERTENCIA: Riesgo de descarga eléctrica. Desconectar la corriente eléctrica del panel (disyuntor). Desconecte la instalación eléctrica en la caja de circuitos/ disyuntor antes de instalar esta unidad o realizar tareas de mantenimiento en ella. No usar en exteriores. CAUTION If using a dimmer, it must be LED compatible. IMPORTANT The installer and/or user must read, understand and follow these instructions before installing the product. This product must be properly installed before it is used. If instructions are not followed, the manufacturer will not be held responsible for any problems or product malfunction. Failure to follow installation and/or operating instructions voids the warranty. We recommend that this product be installed by a certified electrician. In some states or provinces, it is a legal requirement for this type of product to be installed by a certified electrician, according to the electrical and building codes effective in the region where the unit is used. ATTENTION Si un gradateur est utilisé, celui-ci doit être compatible avec les lumières à DEL. IMPORTANT Avant l’installation de ce produit, l’utilisateur et/ou l’installateur doit avoir lu et compris ces instructions. Cet appareil doit être installé convenablement avant usage. Si ces instructions ne sont pas respectées, le fabricant ne pourra être tenu responsable d’aucun problème ou de dysfonctionnement du produit. Le non-respect des instructions d’installation et/ou d’utilisation annulera la garantie en vigueur. Nous recommandons que ce produit soit installé par un électricien certifié. Dans certains États ou provinces, il est légalement requis que ce type de produit soit installé par un électricien certifié conformément aux codes de l’électricité et du bâtiment en vigueur. ATENCIÓN Si utiliza un regulador, debe asegurarse de que es compatible con las luces LED. IMPORTANTE El instalador o usuario debe leer detenidamente las instrucciones antes de instalar el producto y seguirlas fielmente. El producto debe estar correctamente instalado antes de su utilización. Si no siguen las instrucciones, el fabricante no se hará responsable de problemas o de un funcionamiento incorrecto del producto. Si no sigue las instrucciones de instalación o de uso, se anulará la garantía. Le recomendamos que el producto sea instalado por un electricista certificado. En algunos estados o provincias, se requiere por ley que este tipo de producto sea conectado por un electricista certificado siguiendo los códigos eléctricos y arquitectónicos de la región. CAUTION ATTENTION ATENCIÓN 5 CONNECTION BRANCHEMENT CONEXIÓN 1 AB 6 CONNECTION BRANCHEMENT CONEXIÓN 2 A B 7 TURN ON/OFF ALLUMER/ÉTEINDRE ENCENDER/APAGAR 3 A 8 BRIGHTNESS CHANGE CHANGEMENT DE LUMINOSITÉ CAMBIO DE BRILLO 4 100% 60% 20% 0% A 9 Operation is subject to the following two conditions: 1. this device may not cause interference, and 2. this device must accept any inteference, including inteference that may cause undesired operation of the device. L’exploitation est autorisée aux deux conditions suivantes : 1. l’appareil ne doit pas produire de brouillage; et 2. l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. La operación está sujeta a las dos condiciones siguientes: 1. este dispositivo no puede causar interferencias perjudiciales, y 2. este dispositivo debe aceptar cualquier interferencia recibida, incluídas las interferencias que puedan provocar un funcionamiento no deseado. CANADA (IC) 10 WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. this device must accept any interference received,including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instr…
Text truncated - open the document above for the full version.
Certification designating a U.S. Agent for service of process: As required by section 2.911(d)(7), the applicant must designate a contact located in the United States for purposes of acting as the applicant’s agent for service of process, regardless of whether the applicant is a domestic or foreign entity. An applicant located in the United States may designate itself as the agent for service of process. In either scenario, the designation of the U.S. agent for service of process should be provided as an attachment to the equipment authorization application. The applicant must provide a written certification, which must: i. Be signed by both the applicant and designated agent for service of process, if the agent is different from the applicant. ii. Acknowledge the applicant’s consent and the designated agent’s obligation to accept service of process. iii. Provide a physical U.S. address and email for the designated agent. iv. Acknowledge the applicant’s acceptance to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Unofficial information provided by FCC personnel on February 14, 2023, via the monthly call with the TCB Council: The Agent for Process of Service: • cannot be a TCB or affiliated with a TCB (e.g. could not be a person who works for a TCB or a company that owns or is owned by the TCB) • cannot be a [FCC recognised] Lab or affiliated with a test lab (e.g. could not be a person who works for a Lab or a company that owns or is owned by the Lab) • Agent can be Individual Entity or a Company Entity • Agent Entity must be located in US, US address/phone • Entity acting as Agent must have FRN (best practice, put FRN on Agent Letter) • Agent letter does not have to be FCC ID specific, can be general Agent for Grantee For devices being marketed or for which marketing has ceased for less than 1 year, if the Agent for Process of Service changes, then for every TC Number the TCB must request the FCC to put application into Audit Mode and Agent Letter needs to be updated (superseded). NOTE: The U.S. Agent for Service of Process should not be confused with the authorized agent used for signing the 731 form, other cover letters within the application, and/or the agent who may interface with the TCB. U.S. Agent Designation for Service of Process ATTENTION: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA REGARDING: FCC Certification – Section 2.911(d)(7) Information Designated U.S. Agent Company Name: Approve-IT, Inc. Contact Name: Nathan Grinager Street Address: 8011 34 th Ave South, Suite 342 City/Province/Zip: Bloomington, MN 55425 Telephone No: 651-247-1678 Email: [email protected] FRN #: 0027533835 This letter is to confirm that we (“the Designated U.S. Agent) have accepted the responsibility to act as the Designated U.S. Agent for Service of Process as required by section 47 CFR 2.911(d)(7) on behalf of the Applicant noted below. U.S. Agent Signature: Date: March 20, 2023 Signed by (Printed Name/Title): Nathan Grinager / Co-President *This letter must be dated within 1-year of the date the application is submitted to the TCB for device certification The Applicant confirms its explicit consent and acknowledges that they must maintain an agent for no less than one year after terminating all marketing and importation OR the conclusion of any Commission-related proceeding involving the equipment. The applicant further acknowledges their responsibility to inform the FCC whenever the Designated U.S. Agent information above changes. Applicant Company name: Artika For Living Inc. Grantee Code: 2AUHG Contact Name: Mathieu Seguin Street Address: 1756 50 th avenue, City/Province/Zip: Montreal (Lachine)/ Quebec/ Canada/ H8T 2V5 Telephone No: 1-514-883-8699 Email: [email protected] Applicant Signature: Date: 2023-03-20 Signed by (Printed Name/Title): Mathieu Seguin/ Engineering and Quality Control Director
Form: RFT-AMER-TCB-OP-19n Revision: 1 Page 1 of 1 Date: 1/25/2023 Attention: Application Examiner Re: Covered List, located at https://www.fcc.gov/supplychain/coveredlist and 47 CFR parts §2.903 and §2.911(d)(5)(ii) of the FCC rules Applicant: FCC ID: 2AUHG-TL-SB To whom it may concern, Artika For Living Inc (“Applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to 47 CFR part §2.903 of the FCC rules and does not originate directly or indirectly from any company named on the covered list located in the link above or any subsidiary or affiliate thereof. Applicant further certifies that, as of the date of the filing of the application, the Applicant is not identified on the Covered List as an entity producing “covered” equipment and is not a subsidiary or affiliate of any such entity pursuant to 47 CFR part §1.50002 and required by 47 CFR part §2.911(d)(5)(ii) of the FCC rules. I HEREBY CERTIFY THAT I am authorized to make the representations above on behalf of the Applicant and agree to immediately notify Intertek if there is any change in the status identified above. Mathieu Seguin Director of Engineering Artika For Living Inc 2022-06-22
[2023-06-28] Federal Communications Commission 445 12 th Street SW Washington, DC 20554 Subject: Limited Agency Agreement Artika For Living Inc FCC ID: 2AUHG-TL-SB To Whom It May Concern: We, Artika For Living Inc, hereby authorized Intertek Testing Services to act as our Agent for the purpose of preparing application for FCC ID number (2AUHG-FLR-SWK, 2AUHG-TL-SB, 2AUHG-TL-WA) under all applicable parts of the FCC rules and regulations. The effective date of this limited agency agreement is (2023-06-01). The Limited Agency Agreement expires on (2023-09-30), unless sooner terminated or extended by written notice to Intertek Testing Services and the Federal Communications Commission. This is to advise that we are in full compliance with the Anti-Drug Abuse Act. The applicant is not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 U.S.C. 862, and no party to the application is subject to a denial of federal benefits pursuant to that section. If you have any questions or comments, please do not hesitate to contact me. Sincerely, Mathieu Seguin Director of Engineering Artika For Living Inc
1(1) 2023-07-26 Attention: Application Examiner RE: Request for Confidentiality Applicant: Artika For Living Inc. FCC ID: 2AUHG-TL-SB To Whom It May Concern: Permanent Confidentiality Request is hereby submitted by Artika For Living Inc. to withhold permanently from public review certain portions of the application for equipment certification for the referenced FCC identifiers. This request for confidentiality is made pursuant to 47 CFR 0.457(d) and 0.459 of the FCC Rules. In particular, the following sections of the application are to be kept permanently confidential: • Schematics • Detailed Block Diagrams • Detailed Operational/Functional Description Rationale for request for confidentiality: Artika For Living Inc. has invested considerable time and materials in research and development to produce the referenced product. [Permanent confidentiality: Disclosure of the permanently confidential portions of this application to competitors would not only give them significant competitive advantages in developing similar products, but would also disclose successful implementation of unpublished, leading edge technology developed by us.] [Short term confidentiality: Disclosure of the short-term confidential portions of this application during the period of importation and/or distribution would reveal key aspects of proprietary technology to competitors and diminish the value of our investment in research and development.] Sincerely, [Signature] Mathieu Seguin Director of Engineering Artika For Living Inc
TEST REPORT Intertek Report No.: 230613032GZU-001 PHOTOS OF EUT APPENDIX I – PHOTOS OF EUT Outside TEST REPORT Intertek Report No.: 230613032GZU-001 PHOTOS OF EUT Outside Inside TEST REPORT Intertek Report No.: 230613032GZU-001 PHOTOS OF EUT PCB View TEST REPORT Intertek Report No.: 230613032GZU-001 PHOTOS OF EUT Adapter View TEST REPORT Intertek Report No.: 230613032GZU-001 PHOTOS OF EUT Adapter View PCB TEST REPORT Intertek Report No.: 230613032GZU-001 PHOTOS OF EUT Adapter View PCB
The label is on the bottom of the light fixture.
TEST REPORT Intertek Report No.: 230613032GZU-001 PHOTOS OF EUT APPENDIX I – PHOTOS OF EUT Outside TEST REPORT Intertek Report No.: 230613032GZU-001 PHOTOS OF EUT Outside Inside TEST REPORT Intertek Report No.: 230613032GZU-001 PHOTOS OF EUT PCB View TEST REPORT Intertek Report No.: 230613032GZU-001 PHOTOS OF EUT Adapter View TEST REPORT Intertek Report No.: 230613032GZU-001 PHOTOS OF EUT Adapter View PCB TEST REPORT Intertek Report No.: 230613032GZU-001 PHOTOS OF EUT Adapter View PCB
Artika For Living Inc TEST REPORT SCOPE OF WORK EMC TESTING–EH1227(TL-SB-XXXXX) REPORT NUMBER 230613032GZU-001 ISSUE DATE [REVISED DATE] 12-July-2023 [---------------------] PAGES 15 DOCUMENT CONTROL NUMBER FCC Part 15:2021-a © 2022 INTERTEK TEST REPORT Room 02, & 101/E201/E301/ E401/E501/E601/E701/E801 of Room 01 1-8/F., No. 7-2. Caipin Road, Science City, GETDD, Guangzhou, Guangdong, China Telephone: +86 20 8213 9688 Facsimile: +86 20 3205 7538 www.intertek.com.cn This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Testing Services Shenzhen Ltd. Guangzhou Branch Room 02, & 101/E201/E301/E401/E501/E601/E701/E801 of Room 01 1-8/F., No. 7-2. Caipin Road, Science City, GETDD, Guangzhou, Guangdong, China Version: 09-November-2022 Page 2 of 15 FCC Part 15:2021-a Applicant Name & Address : Artika For Living Inc 1756, 50th ave, Lachine Quebec, H8T 2V5 Canada Manufacturing Site : Dongguan City Tianhua Photoelectric Technology Co,. Ltd #3, 2nd Road Jinqianling Industrial Zone, Jitigang Village, Huangjiang Town, Dongguan City-523757, Guangdong, China Intertek Report No: 230613032GZU-001 FCC ID : 2AUHG-TL-SB Test standards CFR 47, FCC Part 15, Subpart B:2021 Sample Description Product : Swirl Butterfly Chrome Table Lamp Model No. : EH1227(TL-SB-XXXXX) “Remark: XXXXX are represent different customers. X=0-9 or A-Z” Electrical Rating : 100-240V 50/60Hz, 10.3W Serial No. Not Labeled Date Received : 13 June 2023 Date Test Conducted : 13 June 2023-05 July 2023 Prepared and Checked By Jackson Zhang Sr. Project Engineer Approved By: Sky Zhu Supervisor TEST REPORT Intertek Report No.: 230613032GZU-001 Version: 09-November-2022 Page 3 of 15 FCC Part 15:2021-a CONTENT TEST REPORT ....................................................................................................................... 1 CONTENT ......................................................................................................................... 3 1. TEST RESULTS SUMMARY ......................................................................................... 4 2. EMC RESULTS CONCLUSION...................................................................................... 5 3. LABORATORY MEASUREMENTS ................................................................................ 6 4. EQUIPMENT USED DURING TEST .............................................................................. 7 5. EMI TEST .................................................................................................................. 8 5.1 CONDUCTED DISTURBANCE VOLTAGE AT MAINS PORTS ......................................................... 8 5.1.1 Block Diagram of Test Setup ............................................................................... 8 5.1.2 Test Setup and Procedure ................................................................................... 8 5.1.3 Limit .................................................................................................................... 9 5.1.4 Test Data and curve .......................................................................................... 10 5.2 RADIATED EMISSION 30 MHZ -1000 MHZ ...................................................................... 12 5.2.1 Block Diagram of Test Setup ............................................................................. 12 5.2.2 Test Setup and Procedure ................................................................................. 12 5.2.3 Limit .................................................................................................................. 13 5.2.4 Test Data and Curve ......................................................................................... 14 5.3 RADIATED EMISSION ABOVE 1 GHZ ................................................................................. 15 TEST REPORT Intertek Report No.: 230613032GZU-001 Version: 09-November-2022 Page 4 of 15 FCC Part 15:2021-a 1. TEST RESULTS SUMMARY Classification of EUT: Class B Test Item Standard Result Conducted disturbance voltage at mains ports CFR 47, FCC Part 15, Subpart B Pass Radiated emission (30 MHz–1 GHz) CFR 47, FCC Part 15, Subpart B Pass Radiated emission (Above 1 GHz) CFR 47, FCC Part 15, Subpart B N/A Remark: Reference publication is used for methods of measurement: ANSI C63.4:2014 Remark: 1. The symbol “N/A” in above table means Not Applicable. 2. When determining the test results, measurement uncertainty of tests has been considered. TEST REPORT Intertek Report No.: 230613032GZU-001 Version: 09-November-2022 Page 5 of 15 FCC Part 15:2021-a 2. EMC RESULTS CONCLUSION RE: EMC Testing Pursuant to FCC part 15 performed on the Swirl Butterfly Chrome Table Lamp, Model: EH1227(TL-SB-XXXXX). We tested the Swirl Butterfly Chrome Table Lamp, Model: EH1227(TL-SB-HD2CR), to determine if it was in compliance with the relevant standards as marked on the Test Results Summary. We found that the unit met the requirement of FCC part 15 standard when tested as received. The worst case’s test data was presented in this test report. All models are same except model name. XXXXX are represent different cus…
Text truncated - open the document above for the full version.
TEST REPORT Intertek Report No.: 230613032GZU-001 PHOTOS OF TEST SETUP APPENDIX – PHOTOS OF TEST SETUP Conducted Emission Radiated Emission (30 MHz–1000 MHz)
Room102/104 · Guangzhou, · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | - | - |

Sondra Vanity 27in Black
Equipment Class
JAV - Other Non-Digital SDoC Devices
Lumilok 2.0 strip light with felt
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
Crystal Cube 1L
Equipment Class
JAV - Other Non-Digital SDoC Devices
Phantome Breeze bladeless fan
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
Kindle FM BLACK
Equipment Class
JAV - Other Non-Digital SDoC Devices