FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. ARTIKA FOR LIVING INC/
  3. 2AUHG-V02897

2AUHG-V02897Led wall lamp

ARTIKA FOR LIVING INC
Led wall lamp - FCC ID 2AUHG-V02897 - ARTIKA FOR LIVING INC
Click to zoom

Application Details

Equipment Class
JAB - Part 15 Class B Digital Device
Date of Grant
Jul 28, 2024
Application Purpose
Original Equipment
Date of Application
Jul 14, 2024
Equipment Note
Led wall lamp
Company
ARTIKA FOR LIVING INC
Country
Canada

Documents & Files

Select a file to view

Users Manual

↗
↗

Attestation Statements

↗
↗
↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Made in China Fabriqué en Chine Hecho en China Residential use only Usage résidentiel seulement Uso residencial solamente Indoor use only Usage intérieur seulement Uso interiores solamente LED vanity light - Nuvo Vanity 24 TM INSTRUCTION MANUAL IMPORTANT: READ CAREFULLY AND KEEP. Applique murale DEL - Nuvo Vanity 24 MC MANUEL D’INSTRUCTIONS IMPORTANT : À LIRE ATTENTIVEMENT ET À CONSERVER. Aplique de pared LED - Nuvo Vanity 24 MR MANUAL DE INSTRUCCIONES IMPORTANTE: LEER DETENIDAMENTE Y CONSERVAR. Model / Modèle / Modelo: 24VAN-NU-BN10TE10-J / 24VAN-NU-BL10TE10-J / 24VAN-NU-CH10TE10-J V02897 Rev. 25-03-2024 2 Screwdriver Tournevis 2 Destornillador WHAT YOU WILL NEED VOUS AUREZ BESOIN LO QUE NECESITARÁ INCLUDED HARDWARE MATÉRIEL INCLUS HERRAMIENTAS INCLUIDAS Item Pièce Pieza Description Description Descripción Quantity Quantité Cantidad A Mounting bracket Support de montage Soporte de montaje × 1 B Wire connector Capuchon de connexion Conector de cable × 3 C Junction box screw Vis de boitier de raccordement Tornillo de caja de conexiones × 2 D Canopy screw Vis de la base Tornillo del dosel × 4 + 1 extra E Vanity light Applique murale Aplique de pared × 1 3 STEP-BY-STEP INSTALLATION INSTALLATION DÉTAILLÉE INSTALACIÓN ETAPA POR ETAPA ACD E B 4 CAUTION ATTENTION ATENCIÓN WARNING: Risk of electrical shock. Turn off circuit breaker at the panel. Switch off the main electrical supply from the fuse box/circuit breaker before installing the unit or doing any maintenance. Do not use outdoors. AVERTISSEMENT: Risque de décharge électrique. Éteindre le disjoncteur sur le panneau électrique. Il est important de couper l’alimentation électrique du disjoncteur avant de procéder à l’installation ou à l’entretien. Ne pas utiliser à l’extérieur. ADVERTENCIA: Riesgo de descarga eléctrica. Desconectar la corriente eléctrica del panel (disyuntor). Desconecte la alimentación eléctrica principal de la caja de fusibles/disyuntor antes de instalar la unidad o de realizar o realizar cualquier tipo de mantenimiento. No usar en exteriores. CAUTION If using a dimmer, it must be LED compatible. IMPORTANT The installer and/or user must read, understand and follow these instructions before installing the product. This product must be properly installed before it is used. If instructions are not followed, the manufacturer will not be held responsible for any problems or product malfunction. Failure to follow installation and/or operating instructions voids the warranty. We recommend that this product be installed by a certified electrician. In some states or provinces, it is a legal requirement for this type of product to be installed by a certified electrician, according to the electrical and building codes in effect in the region where the product is used. ATTENTION Si un gradateur est utilisé, celui-ci doit être compatible avec les lumières à DEL. IMPORTANT Avant l’installation de ce produit, l’utilisateur et/ou l’installateur doit avoir lu et compris ces instructions. Cet appareil doit être installé convenablement avant usage. Si ces instructions ne sont pas respectées, le fabricant ne pourra être tenu responsable d’aucun problème ou dysfonctionnement du produit. Le non-respect des instructions d’installation et/ou d’utilisation annulera la garantie en vigueur. Nous recommandons que ce produit soit installé par un électricien certifié. Dans certains États ou provinces, il est légalement requis que ce type de produit soit installé par un électricien certifié conformément aux codes de l’électricité et du bâtiment en vigueur. ATENCIÓN Si utiliza un regulador, debe asegurarse de que sea compatible con las luces LED. IMPORTANTE El instalador o usuario debe leer, comprender y seguir las instrucciones antes de instalar el producto. El producto debe estar correctamente instalado antes de su utilización. Si no se siguen las instrucciones, el fabricante no se hará responsable de ningún problema o de un funcionamiento incorrecto del producto. Si no se siguen las instrucciones de instalación o de uso, se anulará la garantía. Le recomendamos que el producto sea instalado por un electricista certificado. En algunos estados o provincias, se requiere por ley que este tipo de producto sea instalado por un electricista certificado conforme a los los códigos relativos a la electricidad y la edificación vigentes en la región en la que se utiliza la unidad. 5 MOUNTING BRACKET INSTALLATION INSTALLATION DU SUPPORT DE MONTAGE INSTALACIÓN DEL SOPORTE DE MONTAJE 1 CA 6 WIRE CONEECTION CONNEXION DES FILS CONEXIÓN DE CABLES 2 B E Ground wire (G) Fil de mise à la terre (G) Cable de tierra (G) White (N) Blanc (N) Blanco (N) Black (L) Noir (L) Negro (L) 7 FINAL INSTALLATION INSTALLATION FINALE INSTALACIÓN FINAL 3 ED 8 The guidelines for ADA installation specify that a wall light be no more than 4-inches from the wall and be mounted between 2-feet 4-inches to 6-feet 8-inches above the finished floor. *ADA: Americans with Disabilities Act Les directives d'installation de l'ADA spécifient qu'une applique murale ne doit pas être à plus de 4 pouces du mur et être montée entre 2 pieds 4 pouces et 6 pieds 8 pouces au- dessus du sol fini. *ADA : La loi relative aux Américains ayant un handicap Las pautas para la instalación de ADA especifican que una luz de pared no debe estar a más de 4 pulgadas de la pared y debe montarse entre 2 pies y 4 pulgadas y 6 pies y 8 pulgadas por encima del piso terminado. * ADA: La Ley de estadounidenses con discapacidades ADA* INSTALLATION GUIDELINES DIRECTIVES D'INSTALLATION ADA* DIRECTRICES DE INSTALACIÓN ADA* Operation is subject to the following two conditions: 1. this device does not cause interference, and 2. this device must accept any interference received, including interference that may cause undesired operation. L’exploitation est assujettie aux deux conditions suivantes : 1. l’appareil ne doit pas produire d’interférences; et 2. l’appareil doit accepter toute interférence, même si ces interférences sont susceptible…

Text truncated - open the document above for the full version.

Users Manual

Made in China Fabriqué en Chine Hecho en China Residential use only Usage résidentiel seulement Uso residencial solamente Indoor use only Usage intérieur seulement Uso interiores solamente LED vanity light - Nuvo Vanity 24 TM INSTRUCTION MANUAL IMPORTANT: READ CAREFULLY AND KEEP. Applique murale DEL - Nuvo Vanity 24 MC MANUEL D’INSTRUCTIONS IMPORTANT : À LIRE ATTENTIVEMENT ET À CONSERVER. Aplique de pared LED - Nuvo Vanity 24 MR MANUAL DE INSTRUCCIONES IMPORTANTE: LEER DETENIDAMENTE Y CONSERVAR. Model / Modèle / Modelo: 24VAN-NU-BN10TE10-J / 24VAN-NU-BL10TE10-J / 24VAN-NU-CH10TE10-J V02897 Rev. 25-03-2024 2 Screwdriver Tournevis 2 Destornillador WHAT YOU WILL NEED VOUS AUREZ BESOIN LO QUE NECESITARÁ INCLUDED HARDWARE MATÉRIEL INCLUS HERRAMIENTAS INCLUIDAS Item Pièce Pieza Description Description Descripción Quantity Quantité Cantidad A Mounting bracket Support de montage Soporte de montaje × 1 B Wire connector Capuchon de connexion Conector de cable × 3 C Junction box screw Vis de boitier de raccordement Tornillo de caja de conexiones × 2 D Canopy screw Vis de la base Tornillo del dosel × 4 + 1 extra E Vanity light Applique murale Aplique de pared × 1 3 STEP-BY-STEP INSTALLATION INSTALLATION DÉTAILLÉE INSTALACIÓN ETAPA POR ETAPA ACD E B 4 CAUTION ATTENTION ATENCIÓN WARNING: Risk of electrical shock. Turn off circuit breaker at the panel. Switch off the main electrical supply from the fuse box/circuit breaker before installing the unit or doing any maintenance. Do not use outdoors. AVERTISSEMENT: Risque de décharge électrique. Éteindre le disjoncteur sur le panneau électrique. Il est important de couper l’alimentation électrique du disjoncteur avant de procéder à l’installation ou à l’entretien. Ne pas utiliser à l’extérieur. ADVERTENCIA: Riesgo de descarga eléctrica. Desconectar la corriente eléctrica del panel (disyuntor). Desconecte la alimentación eléctrica principal de la caja de fusibles/disyuntor antes de instalar la unidad o de realizar o realizar cualquier tipo de mantenimiento. No usar en exteriores. CAUTION If using a dimmer, it must be LED compatible. IMPORTANT The installer and/or user must read, understand and follow these instructions before installing the product. This product must be properly installed before it is used. If instructions are not followed, the manufacturer will not be held responsible for any problems or product malfunction. Failure to follow installation and/or operating instructions voids the warranty. We recommend that this product be installed by a certified electrician. In some states or provinces, it is a legal requirement for this type of product to be installed by a certified electrician, according to the electrical and building codes in effect in the region where the product is used. ATTENTION Si un gradateur est utilisé, celui-ci doit être compatible avec les lumières à DEL. IMPORTANT Avant l’installation de ce produit, l’utilisateur et/ou l’installateur doit avoir lu et compris ces instructions. Cet appareil doit être installé convenablement avant usage. Si ces instructions ne sont pas respectées, le fabricant ne pourra être tenu responsable d’aucun problème ou dysfonctionnement du produit. Le non-respect des instructions d’installation et/ou d’utilisation annulera la garantie en vigueur. Nous recommandons que ce produit soit installé par un électricien certifié. Dans certains États ou provinces, il est légalement requis que ce type de produit soit installé par un électricien certifié conformément aux codes de l’électricité et du bâtiment en vigueur. ATENCIÓN Si utiliza un regulador, debe asegurarse de que sea compatible con las luces LED. IMPORTANTE El instalador o usuario debe leer, comprender y seguir las instrucciones antes de instalar el producto. El producto debe estar correctamente instalado antes de su utilización. Si no se siguen las instrucciones, el fabricante no se hará responsable de ningún problema o de un funcionamiento incorrecto del producto. Si no se siguen las instrucciones de instalación o de uso, se anulará la garantía. Le recomendamos que el producto sea instalado por un electricista certificado. En algunos estados o provincias, se requiere por ley que este tipo de producto sea instalado por un electricista certificado conforme a los los códigos relativos a la electricidad y la edificación vigentes en la región en la que se utiliza la unidad. 5 MOUNTING BRACKET INSTALLATION INSTALLATION DU SUPPORT DE MONTAGE INSTALACIÓN DEL SOPORTE DE MONTAJE 1 CA 6 WIRE CONEECTION CONNEXION DES FILS CONEXIÓN DE CABLES 2 B E Ground wire (G) Fil de mise à la terre (G) Cable de tierra (G) White (N) Blanc (N) Blanco (N) Black (L) Noir (L) Negro (L) 7 FINAL INSTALLATION INSTALLATION FINALE INSTALACIÓN FINAL 3 ED 8 The guidelines for ADA installation specify that a wall light be no more than 4-inches from the wall and be mounted between 2-feet 4-inches to 6-feet 8-inches above the finished floor. *ADA: Americans with Disabilities Act Les directives d'installation de l'ADA spécifient qu'une applique murale ne doit pas être à plus de 4 pouces du mur et être montée entre 2 pieds 4 pouces et 6 pieds 8 pouces au- dessus du sol fini. *ADA : La loi relative aux Américains ayant un handicap Las pautas para la instalación de ADA especifican que una luz de pared no debe estar a más de 4 pulgadas de la pared y debe montarse entre 2 pies y 4 pulgadas y 6 pies y 8 pulgadas por encima del piso terminado. * ADA: La Ley de estadounidenses con discapacidades ADA* INSTALLATION GUIDELINES DIRECTIVES D'INSTALLATION ADA* DIRECTRICES DE INSTALACIÓN ADA* Operation is subject to the following two conditions: 1. this device does not cause interference, and 2. this device must accept any interference received, including interference that may cause undesired operation. L’exploitation est assujettie aux deux conditions suivantes : 1. l’appareil ne doit pas produire d’interférences; et 2. l’appareil doit accepter toute interférence, même si ces interférences sont susceptible…

Text truncated - open the document above for the full version.

Attestation Statements

Artika For Living Inc 1756 50th avenue, Lachine, Quebec, Canada H8T 2V5 Covered Equipment Certification Attestation Letter 7/9/2024 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA ATTN.: Reviewing Engineer FCC ID: 2AUHG-V02897 Artika For Living Inc. (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Note: If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List , the applicant should include an explanation on why the equipment is not “covered” equipment. Artika For Living Inc. (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Signed: Printed name: Mathieu Seguin Title: Manager Company Name: Artika For Living Inc Date: 7/9/2024

Attestation Statements

Artika For Living Inc 1756 50th avenue, Lachine, Quebec, Canada H8T 2V5 Covered Equipment Certification Attestation Letter 7/9/2024 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA ATTN.: Reviewing Engineer FCC ID: 2AUHG-V02897 Artika For Living Inc. (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Note: If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List , the applicant should include an explanation on why the equipment is not “covered” equipment. Artika For Living Inc. (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Signed: Printed name: Mathieu Seguin Title: Manager Company Name: Artika For Living Inc Date: 7/9/2024

Attestation Statements

* the applicant must designate a contact located in the United States for purposes of acting as the applicant’s agent for service of process, regardless of whether the applicant is a domestic or foreign entity. An applicant located in the United States may designate itself as the agent for service of process. U.S. Agent Designation for Service of Process - Certification Attestation Letter 7/9/2024 TO: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 ATTN.: Reviewing Engineer FCC ID: 2AUHG-V02897 FRN of applicant: 0028783116 Per section 2.911(d)(7) of the FCC rules, ARTIKA FOR LIVING INC certifies that the equipment for which authorization is sought is designated to the following U.S. agent* for service of process: Company Name: Approve-IT, Inc. FCC Registration Number (FRN): 0027533835 Physical U.S. Company Address: 8011 34 th Ave South, Suite 342 Contact Person: Nathan Grinager Agent Email Address: [email protected] The above contact person accepts the obligation for service of process. The applicant accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Applicant Signed: Agent Signed (if different from Applicant): Signed: Printed name: Mathieu Seguin Title: Engineering and Quality Control Director Company Name: Artika For Living Inc Date: 7/9/2024 Signed: Printed name: Nathan Grinager Title: Co- President Company Name: Approve-IT, Inc. Date: 7/9/2024

Attestation Statements

* the applicant must designate a contact located in the United States for purposes of acting as the applicant’s agent for service of process, regardless of whether the applicant is a domestic or foreign entity. An applicant located in the United States may designate itself as the agent for service of process. U.S. Agent Designation for Service of Process - Certification Attestation Letter 7/9/2024 TO: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 ATTN.: Reviewing Engineer FCC ID: 2AUHG-V02897 FRN of applicant: 0028783116 Per section 2.911(d)(7) of the FCC rules, ARTIKA FOR LIVING INC certifies that the equipment for which authorization is sought is designated to the following U.S. agent* for service of process: Company Name: Approve-IT, Inc. FCC Registration Number (FRN): 0027533835 Physical U.S. Company Address: 8011 34 th Ave South, Suite 342 Contact Person: Nathan Grinager Agent Email Address: [email protected] The above contact person accepts the obligation for service of process. The applicant accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Applicant Signed: Agent Signed (if different from Applicant): Signed: Printed name: Mathieu Seguin Title: Engineering and Quality Control Director Company Name: Artika For Living Inc Date: 7/9/2024 Signed: Printed name: Nathan Grinager Title: Co- President Company Name: Approve-IT, Inc. Date: 7/9/2024

Cover Letter(s)

DATE : 7/09/2024 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: 2AUHG-V02897 Product Name: Led wall lamp Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commission’s rules, we hereby request that the following documents be held confidential: (List here the documents for which you are seeking confidentiality – for example ...)  Schematics  Block diagram  Operation description These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. <Signature> Name:Mathieu Seguin Title: Manager Company : Artika For Living Inc

Cover Letter(s)

DATE: 07/09/2024 Federal Communications Commission Authorization & Evaluation Division 7345 Oakland Mills Road Columbia, Maryland 21046 Authority to Act asAgent On our behalf, I appoint Dongguan New Testing Centre Co., Ltd;1F & 3F, No. 1 the 1st North Industry Road Songshan Lake Science & Technology Park Dongguan, People’s Republic of China 523808. to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the Federal Communications Commission’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, still resides with Artika For Living Inc. & 1756 50th avenue, Lachine, Quebec, Canada H8T 2V5 <Signature> Name:Mathieu Seguin Title: Manager Company : Artika For Living Inc

Cover Letter(s)

Model difference statement Application company: Artika For Living Inc. Address: 1756 50th avenue, Lachine, Quebec, Canada H8T 2V5 Product name: Led wall lamp Trade mark: ARTIKA Model name: V02897; 24VAN-NU-BL10TE10-J (1 commercial use only. 2. All models are the same except for the model name. ) The circuit and PCB layout are the same, All models are electrically identical. <Signature> Name:Mathieu Seguin Title: Manager Company : Artika For Living

External Photos

External photos Model No: V02897 Fig.1(Model:V02897) Fig.2(Model: V02897)

ID Label/Location Info

Label and label location Model No: V02897

Internal Photos

Internal Photos Model No: V02897 Fig.3(Model: V02897) Fig.4(Model: V02897) Fig.5(Model: V02897)

Test Report

DO ◎A Re T Repor Applic Addre ONGGUAN ddress: 1F & public of Chi Tel: +86-76 rt No. .......... cant’s name ess .............. N NEW TE & 3F, No. 1 th ina 523808 69-222120 FCC .................... e .................. .................... ESTING CE he 1st North 079 W C TE ........ NTC‐E ........ Artika ........ 1756 5 ENTRE CO Industry Roa Web: http: ST R ER2404039 For Living 50th avenu O., LTD ad Songshan //www.ntc REPO Inc e, Lachine, n Lake Scien ‐cert.com ORT Quebec, Ca nce & Techno E-m anada H8T 2 ology Park D mail: dave@ 2V5 Dongguan, P @ntc-cert.c People’s com Dongguan New Testing Centre Co., Ltd E-mail: [email protected] 1F & 3F, No. 1 the 1st North Industry Road Songshan Lake Science & Technology Park Dongguan, People’s Republic of China 523808 Page 1 of 18 Report No.: NTC-ER2404039 TABLE OF CONTENTS Test Report Declare ........................................................................................................................................ 2 1. Summary of test results .......................................................................................................................... 4 2. General test information ......................................................................................................................... 4 2.1. Description of EUT ................................................................................................................................... 4 2.2. Detail models .......................................................................................................................................... 4 2.3. Block diagram EUT configuration for test ............................................................................................... 4 2.4. Test environment conditions .................................................................................................................. 5 2.5. Measurement uncertainty ...................................................................................................................... 5 2.6. Test Laboratory ....................................................................................................................................... 5 3. Power Line Conducted Emission Test ..................................................................................................... 6 3.1. Test equipment ....................................................................................................................................... 6 3.2. Block diagram of test setup..................................................................................................................... 6 3.3. Power Line Conducted Emission Limits (Class B) .................................................................................... 6 3.4. Test Procedure ........................................................................................................................................ 7 3.5. Test Result ............................................................................................................................................... 7 4. Radiated emission test .......................................................................................................................... 10 4.1. Test equipment ..................................................................................................................................... 10 4.2. Block diagram of test setup................................................................................................................... 10 4.3. Radiated emission limit (Class B) .......................................................................................................... 11 4.4. Test Procedure ...................................................................................................................................... 11 4.5. Test result .............................................................................................................................................. 12 5. Test setup photograph .......................................................................................................................... 14 5.1. Photos of power line conducted emission test ..................................................................................... 14 5.2. Photos of radiated emission test .......................................................................................................... 14 6. Photos of the EUT.................................................................................................................................. 15 Dong 1F & 3F, N Test Stan FCC Rule We Decla The equi configur a are conta responsi After te s requirem Report Date of Prep _______ Taylor Note: T h without w FCC ID Applican Address Equipm Test Model N Trade M Manufa Address Test Lab Address gguan New T o. 1 the 1st North ndard Used: es and Regula are: pment descr ation tested t ained in this t bility for the st and evalua ment of the a t No.: NT f Test: Ap pared By: __________ r Chen /Eng his report ap written appro nt s ent under No Mark cturer s boratory s Testing Cent h Industry Road tions Part 1 5 ibed above is the equipme test report an accuracy and ation, our opi bove FCC sta TC‐ER24040 pr.15, 2024 _____ gineer plies to abov oval of Dongg : 2AUH : Artika : 1756 : Led w : V028 : ARTI : Dong : Yuan Gua n : Dong : 1F & & Te c re Co., Ltd Songshan Lake TEST R 5 Subpart B C s tested by D nt complied w nd Dongguan d completene inion is that t andards. 039 to Apr.19, ve tested sam guan New Te HG-V02897 a For Living 50th avenu wall lamp 97; 24VAN KA gGuan City Quan No.6 ngDong Pro gguan New 3F, No. 1 th chnology Pa Science & Tech Page 2 of REPORT DE lass B; ANSI C ongguan New with the stan n New Testing ess of these t the equipme 2024 Dat mple only. T esting Centre Inc ue, Lachine -NU-BL10T Rising Stars Bai Hao Vi vince China Testing Cen he 1st North ark Donggu E-mai nology Park Don f 18 …

Text truncated - open the document above for the full version.

Test Report

DO ◎A Re T Repor Applic Addre ONGGUAN ddress: 1F & public of Chi Tel: +86-76 rt No. .......... cant’s name ess .............. N NEW TE & 3F, No. 1 th ina 523808 69-222120 FCC .................... e .................. .................... ESTING CE he 1st North 079 W C TE ........ NTC‐E ........ Artika ........ 1756 5 ENTRE CO Industry Roa Web: http: ST R ER2404039 For Living 50th avenu O., LTD ad Songshan //www.ntc REPO Inc e, Lachine, n Lake Scien ‐cert.com ORT Quebec, Ca nce & Techno E-m anada H8T 2 ology Park D mail: dave@ 2V5 Dongguan, P @ntc-cert.c People’s com Dongguan New Testing Centre Co., Ltd E-mail: [email protected] 1F & 3F, No. 1 the 1st North Industry Road Songshan Lake Science & Technology Park Dongguan, People’s Republic of China 523808 Page 1 of 18 Report No.: NTC-ER2404039 TABLE OF CONTENTS Test Report Declare ........................................................................................................................................ 2 1. Summary of test results .......................................................................................................................... 4 2. General test information ......................................................................................................................... 4 2.1. Description of EUT ................................................................................................................................... 4 2.2. Detail models .......................................................................................................................................... 4 2.3. Block diagram EUT configuration for test ............................................................................................... 4 2.4. Test environment conditions .................................................................................................................. 5 2.5. Measurement uncertainty ...................................................................................................................... 5 2.6. Test Laboratory ....................................................................................................................................... 5 3. Power Line Conducted Emission Test ..................................................................................................... 6 3.1. Test equipment ....................................................................................................................................... 6 3.2. Block diagram of test setup..................................................................................................................... 6 3.3. Power Line Conducted Emission Limits (Class B) .................................................................................... 6 3.4. Test Procedure ........................................................................................................................................ 7 3.5. Test Result ............................................................................................................................................... 7 4. Radiated emission test .......................................................................................................................... 10 4.1. Test equipment ..................................................................................................................................... 10 4.2. Block diagram of test setup................................................................................................................... 10 4.3. Radiated emission limit (Class B) .......................................................................................................... 11 4.4. Test Procedure ...................................................................................................................................... 11 4.5. Test result .............................................................................................................................................. 12 5. Test setup photograph ...........................................................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Mathieu Seguin(Engineering & QC Director)
[email protected]514-883-8699Fax: 514-636-7666

Test Firm

Dongguan New Testing Centre Co., LtdDave Gao
[email protected]86-15625558400

Technical Specifications

#Rule PartsFrequency RangePower Output
115B--
Confidentiality
Long Term

Other Applications from ARTIKA FOR LIVING INC

Sondra Vanity 27in Black - FCC ID 2AUHG-VAN-SDA5C - ARTIKA FOR LIVING INC
2AUHG-VAN-SDA5C

Sondra Vanity 27in Black

Sep 03, 2026

Equipment Class

JAV - Other Non-Digital SDoC Devices
Lumilok 2.0 strip light with felt - FCC ID 2AUHG-SL-LM2 - ARTIKA FOR LIVING INC
2AUHG-SL-LM2

Lumilok 2.0 strip light with felt

Aug 27, 2026

Equipment Class

CYY - Communications Receiver used w/Pt 15 Transmitter
Crystal Cube 1L - FCC ID 2AUHG-PDT1CC-JF - ARTIKA FOR LIVING INC
2AUHG-PDT1CC-JF

Crystal Cube 1L

Aug 25, 2026

Equipment Class

JAV - Other Non-Digital SDoC Devices
Phantome Breeze bladeless fan - FCC ID 2AUHG-FAN-FBR - ARTIKA FOR LIVING INC
2AUHG-FAN-FBR

Phantome Breeze bladeless fan

Aug 20, 2026

Equipment Class

CYY - Communications Receiver used w/Pt 15 Transmitter
Kindle FM BLACK - FCC ID 2AUHG-15FM-KIN - ARTIKA FOR LIVING INC
2AUHG-15FM-KIN

Kindle FM BLACK

Aug 20, 2026

Equipment Class

JAV - Other Non-Digital SDoC Devices