
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Made in China Fabriqué en Chine Hecho en China Residential use only Usage résidentiel seulement Uso residencial solamente Indoor use only Usage intérieur seulement Uso interiores solamente anti-fog LED wall mirror - Aurea TM INSTRUCTION MANUAL IMPORTANT: READ CAREFULLY AND KEEP. Miroir mural anti-buée à DEL - Aurea MC MANUEL D’INSTRUCTIONS IMPORTANT: À LIRE ATTENTIVEMENT ET À CONSERVER. Espejo LED antivaho de pared - Aurea MR MANUAL DE INSTRUCCIONES IMPORTANTE: LEER DETENIDAMENTE Y CONSERVAR. Rev. 10-26-2020 Model / Modèle / Modelo: WMIRH-SACH-2431-C 2 ITEM PIÈCE PIEZA DESCRIPTION DESCRIPTION DESCRIPCIÓN QUANTITY QUANTITÉ CANTIDAD A Wall anchor Support de montage Soporte de montaje × 2 B Fixation screw Vis de raccordement Tornillo de conexiones × 2 C Wire connector Capuchon de connexion Conector de cable × 2 D Mirror Miroir Espejo × 1 Screwdriver Tournevis 2 Destornillador Drill Perceuse Taladro 5/16 in. drill bit (8 mm) Mèche 5/16 po. (8 mm) Broca 5/16 plg. (8 mm) Measuring tape Ruban à mesurer Cinta métrica Level Niveau Nivel WHAT YOU WILL NEED VOUS AUREZ BESOIN LO QUE NECESITARÁ INCLUDED HARDWARE MATÉRIEL INCLUS HERRAMIENTAS INCLUIDO 3 DETAILED VIEW VUE DETALLÉE VISTA DETALLADA 1 A D C B 4 CAUTION ATTENTION ATENCIÓN WARNING: Risk of electrical shock. Turn off breaker at the panel. Switch off the main electrical supply from the fuse box/ circuit breaker before installing the unit or doing any maintenance. Do not use outdoor. AVERTISSEMENT: Risque de décharge électrique. Éteindre le disjoncteur sur le panneau électrique. Il est important de couper l’alimentation électrique du disjoncteur avant de procéder à l’installation ou à l’entretien. Ne pas utiliser à l’extérieur. ADVERTENCIA: Riesgo de descarga eléctrica. Desconectar la corriente eléctrica del panel (disyuntor). Desconecte la instalación eléctrica en la caja de circuitos/ disyuntor antes de instalar esta unidad o realizar tareas de mantenimiento en ella. No usar en exteriores. IMPORTANT The installer and/or user must read, understand and follow these instructions before installing the product. This product must be properly installed before it is used. If instructions are not followed, the manufacturer will not be held responsible for any problems or product malfunction. Failure to follow installation and/or operating instructions voids the warranty. We recommend that this product be installed by a certified electrician. In some states or provinces, it is a legal requirement for this type of product to be installed by a certified electrician, according to the electrical and building codes effective in the region where the unit is used. IMPORTANT Avant l’installation de ce produit, l’utilisateur et/ou l’installateur doit avoir lu et compris ces instructions. Cet appareil doit être installé convenablement avant usage. Si ces instructions ne sont pas respectées, le fabricant ne pourra être tenu responsable d’aucun problème ou de dysfonctionnement du produit. Le non-respect des instructions d’installation et/ou d’utilisation annulera la garantie en vigueur. Nous recommandons que ce produit soit installé par un électricien certifié. Dans certains États ou provinces, il est légalement requis que ce type de produit soit installé par un électricien certifié conformément aux codes de l’électricité et du bâtiment en vigueur. IMPORTANTE El instalador o usuario debe leer detenidamente las instrucciones antes de instalar el producto y seguirlas fielmente. El producto debe estar correctamente instalado antes de su utilización. Si no siguen las instrucciones, el fabricante no se hará responsable de problemas o de un funcionamiento incorrecto del producto. Si no sigue las instrucciones de instalación o de uso, se anulará la garantía. Le recomendamos que el producto sea instalado por un electricista certificado. En algunos estados o provincias, se requiere por ley que este tipo de producto sea conectado por un electricista certificado siguiendo los códigos eléctricos y arquitectónicos de la región. 5 WALL INSTALLATION INSTALLATION MURALE INSTALACIÓN EN LA PARED 1 Have a nearby power supply Disposer d’une alimentation éléctrique à proximité Tener una fuente de alimentación cercana ! ! ! ! Hole spacing Espacement des trous Espacio entre agujeros 30 cm (11.81 in / po / plg) Minimum height Hauteur minimale Altura mínima 80.2 cm (31,57 in / po / plg) Minimum height from the counter Hauteur minimale depuis le comptoir Altura mínima desde el mostrador 10 cm (3,94 in / po / plg) 6 WALL INSTALLATION (VERICAL + HORIZONTAL) INSTALLATION MURALE (VERICAL + HORIZONTAL) INSTALACIÓN EN LA PARED (VERICAL + HORIZONTAL) 2 A A B B ! ! Hole spacing Espacement des trous Espacio entre agujeros 30 cm (11.81 in / po / plg) Hole spacing Espacement des trous Espacio entre agujeros 40 cm (15,748 in / po / plg) VERTICAL HORIZONTAL 7 CONNECTION BRANCHEMENT CONEXIÓN 3 D C Black (L) Noir (L) Negro (L) White (N) Blanc (N) Blanco (N) 8 WALL INSTALLATION INSTALLATION MURALE INSTALACIÓN EN LA PARED 4 A B B 30 cm 11.81 in / po / plg) ! Hole spacing Espacement des trous Espacio entre agujeros 40 cm (15,748 in / po / plg) HORIZONTAL VERTICAL 9 FUNCTIONS: SWITCH ON / DIM / OFF + ANTI FOG FONCTIONS: ALLUMER / LUMINOSITÉ AJUSTABLE / ÉTEINDRE + ANTI-BUÉE FUNCIONES: ENCENDER / LUMINOSIDAD AJUSTABLE / APAGAR + ANTI NIEBLA 5 D D Anti fog Anti-buée Anti niebla Switch On (Short touch) - Switch Off (Short touch) Change CCT (Short touch) - Dim (Long Touch) Allumer (toucher court) - Éteindre (toucher court) Changer CCT (toucher court) - Dim (toucher long) Encender (toque corto) - Apagar (toque corto) Cambiar CCT (toque corto) - Atenuado (toque largo) 10 Operation is subject to the following two conditions: 1. this device may not cause interference, and 2. this device must accept any inteference, including inteference that may cause undesired operation of the device. L’exploitation est autorisée aux deux conditions suivantes : 1. l’appareil ne doit pas produire de brouillage; et 2. l’appareil doit …
Text truncated - open the document above for the full version.
Artika for Living Inc. Date: December 14, 2020 Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID:2AUHG-WMIRH-SACH Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name Schematics Block Diagram Operational Description Schematic.pdf Block Diagram.pdf Operation Description.pdf The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Artika for Living Inc. Signature Typed name and Title: Mathieu Seguin, Engineering/QC Director
Declaration Except WMIRH-SACH-2431-D14, these three models HCL-55U-2432-EDD-4, WMIRH-SACH-2431-C and WMIRH-SACH-2431-XXXXXX are totally the same, only except the model name. The only differences of WMIRH-SACH-2431-D14 is provided with a wooden support. Artika for Living Inc. Signature Typed name and Title Mathieu Seguin, Engineering/QC Director 2020/12/14
Artika for Living Inc. FCC ID:2AUHG-WMIRH-SACH POWER OF ATTORNEY Date: December 14, 2020 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 To Whom It May Concern: We, the undersigned, hereby authorize Waltek Testing Group (Foshan) Co., Ltd. (Dara Zhou) on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by Waltek Testing Group (Foshan) Co., Ltd. (Dara Zhou) on our behalf shall have the same effect as acts of our own. This authorization expires on December 14, 2021 . This is to advise that we are in full compliance with the Anti-Drug Abuse Act. We, Artika for Living Inc. are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Sincerely, Artika for Living Inc. Signature Typed name and Title Mathieu Seguin, Engineering/QC Director .
Model: HCL-55U-2432-EDD-4 Page 1 of 3 Picture 1 Picture 2 Model: HCL-55U-2432-EDD-4 Page 2 of 3 Picture 3 Picture 4 Model: HCL-55U-2432-EDD-4 Page 3 of 3 Picture 5 Picture 6
Model: HCL-55U-2432-EDD-4 Page 1 of 3 Picture 1 Picture 2 Model: HCL-55U-2432-EDD-4 Page 2 of 3 Picture 3 Picture 4 Model: HCL-55U-2432-EDD-4 Page 3 of 3 Picture 5
Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Page 1 of 20 TEST REPORT Reference No. .................... : WTN20F12094902E Applicant ............................ : Artika for Living Inc. Address .............................. : 1756, 50th Avenue Lachine, QC H8T 2V5 Canada Manufacturer .................... : Prosperous(Ningbo)Lighting Appliance Co.,Ltd Address .............................. : No.299,Wancheng Road,Shiqi,Yinzhou district, Ningbo 315153 P.R.China Product Name .................... : Vanity Mirror Trade Mark ......................... : Ganpe and Artika Model No. ........................... : Refer to section 3.2 Standards .......................... : 47 CFR PART 15 SUBPART B (Oct.,2019) Date of Receipt sample .... : 2020-10-13 Date of Test ....................... : 2020-10-15 Date of Issue ...................... : 2020-12-14 Test Report Form No. ....... : WEO-FCC15A-01B Test Result ......................... : Pass Remarks: The results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Prepared By: Waltek Testing Group (Foshan) Co., Ltd. Address: No.13-19, 2/F., 2nd Building, Sunlink International Machinery City, Chencun, Shunde District, Foshan, Guangdong, China Tel:+86-757-23811398 Fax:+86-757-23811381 E-mail:[email protected] Compiled by: Approved by: Roy Hong / Project Engineer Danny Zhou / Manager Reference No.: WTN20F12094902E Page 2 of 20 Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn 1 Test Summary Test Item Test Requirement Class Test Method Test Result Conducted Emission 47 CFR PART 15 SUBPART B (Oct.,2019) Class B ANSI C63.4: 2014 Pass Radiated Emission 47 CFR PART 15 SUBPART B (Oct.,2019) Class B ANSI C63.4: 2014 Pass Remark: Pass Test item meets the requirement N/A Test case does not apply to the test object Reference No.: WTN20F12094902E Page 3 of 20 Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn 2 Contents Page COVER PAGE ················································································································· 1 1 TEST SUMMARY .................................................................................................................................................. 2 2 CONTENTS ............................................................................................................................................................ 3 3 GENERAL INFORMATION .................................................................................................................................. 4 3.1 GENERAL DESCRIPTION OF E.U.T. ................................................................................................................ 4 3.2 DETAILS OF E.U.T........................................................................................................................................... 4 3.3 DESCRIPTION OF SUPPORT UNITS.................................................................................................................. 4 3.4 STANDARDS APPLICABLE FOR TESTING ......................................................................................................... 4 3.5 TEST FACILITY ................................................................................................................................................. 5 3.6 SUBCONTRACTED ............................................................................................................................................ 5 3.7 ABNORMALITIES FROM STANDARD CONDITIONS ............................................................................................ 5 3.8 OTHER ............................................................................................................................................................. 5 4 EQUIPMENT USED DURING TEST .................................................................................................................. 6 4.1 SOFTWARE LIST .............................................................................................................................................. 6 4.2 MEASUREMENT UNCERTAINTY ....................................................................................................................... 7 4.3 SPECIAL ACCESSORIES AND AUXILIARY EQUIPMENT ..................................................................................... 7 4.4 DECISION RULE ............................................................................................................................................... 7 5 EMISSION TEST RESULTS ................................................................................................................................ 8 5.1 CONDUCTED EMISSION ................................................................................................................................... 8 5.1.1 E.U.T. Operation ...................................................................................................................................... 8 5.1.2 Block Diagram of Test Setup ................................................................................................................. 8 5.1.3 Measurement Data .................................................................................................................................. 8 5.1.4 Corrected Amplitude & Margin Calculation .......................................................................................... 9 5.1.5 Conducted Emission Test Data ............................................................................................................. 9 5.2 RADIATED EMISSION ..................................................................................................................................... 11 5.2.1 E…
Text truncated - open the document above for the full version.
Model: HCL-55U-2432-EDD-4 Page 1 of 1 Test Setup For Conducted Emission Test Setup For Radiated Emission (30MHz to 1GHz)
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | - | - |

Sondra Vanity 27in Black
Equipment Class
JAV - Other Non-Digital SDoC Devices
Lumilok 2.0 strip light with felt
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
Crystal Cube 1L
Equipment Class
JAV - Other Non-Digital SDoC Devices
Phantome Breeze bladeless fan
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
Kindle FM BLACK
Equipment Class
JAV - Other Non-Digital SDoC Devices