FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. ROCKWOOL B.V. / Grodan/
  3. 2AUKP-RZ002

2AUKP-RZ002Rootzone Sensor

ROCKWOOL B.V. / Grodan
Rootzone Sensor - FCC ID 2AUKP-RZ002 - ROCKWOOL B.V. / Grodan
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Sep 27, 2022
Application Purpose
Original Equipment
Date of Application
Sep 22, 2022
Equipment Note
Rootzone Sensor
Frequency Range
902.00000000 - 928.00000000
Company
ROCKWOOL B.V. / Grodan
Country
Netherlands

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

User Manual GS21RZ03 version 1.5 Rockwool BV – Grodan is part of the Rockwool Group. Industrieweg 15, 6045 JG Roermond, the Netherlands www.grodan.com 0 User Manual Rootzone sensor GS21RZ03 User Manual GS21RZ03 version 1.5 Rockwool BV – Grodan is part of the Rockwool Group. Industrieweg 15, 6045 JG Roermond, the Netherlands www.grodan.com 1 Safety warning English: Be careful, this product contains six sharp measurement pins that can cause cutting or puncture. Do not touch! French: Attention, ce produit contient six broches de mesure tranchantes qui peuvent provoquer des coupures ou des perforations. Ne pas toucher! Spanish: Tenga cuidado, este producto contiene seis clavijas de medición afiladas que pueden causar cortes o perforaciones. ¡No tocar! German: Seien Sie vorsichtig, dieses Produkt enthält sechs scharfe Messstifte, die zu Schnitten oder Durchschlägen führen können. Nicht Tasten! Dutch: Wees voorzichtig, dit product bevat zes scherpe meetpennen die snijwonden of perforaties kunnen veroorzaken. Niet aanraken! User Manual GS21RZ03 version 1.5 Rockwool BV – Grodan is part of the Rockwool Group. Industrieweg 15, 6045 JG Roermond, the Netherlands www.grodan.com 2 Introduction The GS21RZ03 (Rootzone sensor) is part of the Grodan GroSens sensor platform. This sensor platform enables growers to read out climate and root zone information from their growing rooms and view this data in a mobile phone app or in graphs on their desktop or laptop. The GS21RZ03 has been certified for the European (including Turkey), USA and Canadian markets. Onboarding For onboarding the sensor in the platform, please download the “Companion” App from the Apple App Store or Google Play Store. Follow the instructions in the app to configure and connect the sensor. User Manual GS21RZ03 version 1.5 Rockwool BV – Grodan is part of the Rockwool Group. Industrieweg 15, 6045 JG Roermond, the Netherlands www.grodan.com 3 Placement Position in the substrate Picture 1A and 1B show the correct placement of the sensors in the substrates:  Place the sensor 8-10 cm to the left of the 2 nd block from the water drain hole  Sensor should be positioned closer to 2 nd than to 1 st block, ideally at 2/3 of distance towards second block. If blocks are close to each other, the minimum distance is 5 cm between sensor and block. Picture 2A and 2B show placement of the sensors, in case the substrates is on a slope  Place the sensor at the lower side of the slope in the substrate Adjustment for different substrate thicknesses The support plate at the back of the sensor can be adjusted with the screw to one of the four different positions. Each position is optimized for the indicated substrate thickness: 7.5, 8.5, 10 and 12 cm. The substrate thickness can be read through the window in the support plate. Note: the 7.5 cm position is not visible in the picture as it is behind the alignment plate.   User Manual GS21RZ03 version 1.5 Rockwool BV – Grodan is part of the Rockwool Group. Industrieweg 15, 6045 JG Roermond, the Netherlands www.grodan.com 1 2 Radio Frequency - declaration of Conformity European Union This device complies with RED articles 3.1.a, 3.1.b and 3.2. North America FCC Declaration of Conformity (for USA) This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC ID: 2AUKP-RZ001 NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense The provided antenna must be used with this unit to ensure compliance. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. To comply with FCC/IC RF exposure limits for general population / uncontrolled exposure, the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Canada Innovation, Science and Economic Development Canada (ISED) Declaration of Conformity This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes: (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de Classe B est conforme à la norme Canadienne ICES-003. IC: 25447-RZ001 User Manual GS21RZ03 version 1.5 Rockwool BV – Grodan is part of the Rockwool Group. Industrieweg 15, 6045 JG Roermond, the Netherlands www.grodan.com 2 3 Product Details Applicable Product Number: RZ21GS13 - Rootzone sensor LoRa Operating Frequency Range: 863 – 870 MHz (EU) 902 – 928 MHz (USA, CAN) Maximum Output Power: 14 dBm (EU) 22 dBm (U…

Text truncated - open the document above for the full version.

Cover Letter(s)

FCC, Request for non-disclosure Date: 21-Nov-2018 RF_501, Issue 8 Page 1 of 1 ROCKWOOL BV / Grodan Industrieweg 15, 6045 JG Roermond, The Netherlands To: kiwa Telefication B.V., Dept. FCC TCB Wilmersdorf 50 7327 AC Apeldoorn The Netherlands Subject: Request for confidentiality FCC ID: 2AUKP-RZ002 Reference number: ###### Dear FCC TCB, 1. Long-Term Confidentiality Pursuant to 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in support of FCC certification application: Bill(s) of Material Block Diagrams Operational Description Schematic Diagrams Tune-up Procedure Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. 2. Short-Term Confidentiality (STC) Pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, applicant hereby requests Short-Term Confidential treatment of the following materials (See notes below): Internal Photos User’s Manual Test Set-up Photos External Photos Justification: Date: 28-03-2022 Name and signature of applicant: S. van Wijk Notes: 1) A document or type of document can only have ONE type of confidentiality! 2) Short-Term confidentiality is in principle for 45 days from date of grant; it can be extended max 3 times (total time 180 days max.)! The planned date should stated in the RF731 application form. 3) FCC must be informed when marketing begins earlier. 4) Release takes place automatically thus extension must be requested in time. Telefication does not remind you of this! 5) Request for extension or for release must be received by Telefication at least 7 days before date of actual marketing or before expiration of the STC period

External Photos

Page 1 of 2 External Photo Module Product name : Rootzone Sensor Applicant : Rockwool BV FCC ID : 2AUKP-RZ002 ISED ID : 25447-RZ002 Test report No. 200701990 Test report No. 200701990 Page 1 of 2 Table of Contents 1 External Photos ........................................................................................................................................ 2 1.1 Front View ............................................................................................................................................. 2 1.2 Back view............................................................................................................................................... 2 Test report No. 200701990 Page 2 of 2 1 External Photos 1.1 Front View 1.2 Back view

Internal Photos

Page 1 of 4 Internal Photo Module Product name : Rootzone Sensor Applicant : Rockwool BV FCC ID : 2AUKP-RZ002 ISED ID : 25447-RZ002 Test report No. 200701990 Test report No. 200701990 Page 1 of 4 Table of Contents 1 Internal Photos ........................................................................................................................................ 2 1.1 Front view ............................................................................................................................................. 2 1.2 Back view............................................................................................................................................... 3 1.3 RF section lora ....................................................................................................................................... 4 1.4 RF section BLE ....................................................................................................................................... 4 Test report No. 200701990 Page 2 of 4 1 Internal Photos 1.1 Front view Test report No. 200701990 Page 3 of 4 1.2 Back view Test report No. 200701990 Page 4 of 4 1.3 RF section lora 1.4 RF section BLE

RF Exposure Info

Page 1 of 5 FCC RF exposure report Product name : Rootzone Sensor Applicant : Rockwool BV FCC ID : 2AUKP-RZ002 ISED ID : 25447-RZ002 Test report No. : 200701990 005 Ver 1.00 Report number: 200701990 005 Ver 1.00 Page 1 of 5 Laboratory information Accreditation Telefication complies with the accreditation criteria for test laboratories as laid down in ISO/IEC 17025:2017. The accreditation covers the quality system of the laboratory as well as the specific activities as described in the authorized annex bearing the accreditation number L021 and is granted on 30 November 1990 by the Dutch Council For Accreditation (RvA: Raad voor Accreditatie). Telefication is designated by the FCC as an Accredited Test Firm for compliance testing of equipment subject to Certification under Parts 15 & 18. The Designation number is: NL0001. Telefication is a Wireless Device Testing laboratory recognized by Innovation, Science and Economic Development Canada to test to Canadian radio equipment requirements. Telefication is a registered Conformity Assessment body (CAB) under the Japan-EC MRA (Agreement on Mutual Recognition between Japan and the European Community). The registration number is: 201. Documentation The test report must always be reproduced in full; reproduction of an excerpt only is subject to written approval of the testing laboratory. The documentation of the testing performed on the tested devices is archived for 10 years at Telefication Netherlands. Testing Location Test Site Kiwa Telefication BV Test Site location Wilmersdorf 50 7327 AC Apeldoorn The Netherlands Tel. +31 88998 3393 Test Site FCC NL0001 Report number: 200701990 005 Ver 1.00 Page 2 of 5 Revision History Version Date Remarks By V0.50 31-03-2021 Release version K.K. v1.00 04-06-2021 Release version RvB Report number: 200701990 005 Ver 1.00 Page 3 of 5 Table of Contents Revision History .............................................................................................................................................. 2 1 General Description ................................................................................................................................. 4 1.1 Applicant ................................................................................................................................................ 4 1.2 Manufacturer ........................................................................................................................................ 4 1.3 Tested Equipment Under Test (EUT) ..................................................................................................... 4 1.4 SAR Measurement Evaluation ............................................................................................................... 5 1.4.1 Maximum Output Power ................................................................................................................... 5 1.4.2 SAR Testing Exclusions, Mobile use ................................................................................................... 5 1.5 Summary ................................................................................................................................................ 5 Report number: 200701990 005 Ver 1.00 Page 4 of 5 1 General Description 1.1 Applicant Client name: Rockwool BV Address: Industrieweg 15, Roermond, The Netherlands Zip code: 6045 JG E-mail: [email protected] Contact name: Mr. E. Dilling 1.2 Manufacturer Client name: Rockwool BV Address: Industrieweg 15, Roermond, The Netherlands Zip code: 6045 JG E-mail: [email protected] Contact name: Mr. E. Dilling 1.3 Tested Equipment Under Test (EUT) Product name: Rootzone Sensor Brand name: ROCKWOOL, Grodan, GroSens Product type: GS21RZ03 Model(s): -- Software version: -- Hardware version: -- Report number: 200701990 005 Ver 1.00 Page 5 of 5 1.4 SAR Measurement Evaluation 1.4.1 Maximum Output Power The maximum radiated power including tune-up tolerance is shown as below. Mode Output power (dBm) LoRa 1.22 BLE 3.05 1.4.2 SAR Testing Exclusions, Mobile use Calculation method of RF Safety Distance: = ∗ 4 Where: PD = Power Density in / Pout = Output power in mW G = Gain of antenna R = Distance between observation point and centre of the radiator in cm Antenna Technology LoRa/BLE Antenna type PCB Antenna Antenna gain -4.9 dBi/0 dBi Calculation results Technology Frequency (MHz) Max power (mW) Antenna gain (numeric) Distance (cm) Power density ( / ) Limit ( / ) LoRa 908.7 1.32 .32 20 0.021 1 BLE 2440 2.01 1 20 0.105 1 1.5 Summary Since the SAR testing for all device orientations apply SAR test exclusion per KDB 447498, SAR testing for this device is not required.

Test Report

FCC and IC Test report for parts 15.109 15.207, 15.209, 15.247, RSS-247, RSS-Gen Product name : Rootzone Sensor Applicant : Rockwool BV FCC ID : 2AUKP-RZ002 ISED ID : 25447-RZ002 Test report No. : 200701990 007 Ver 2.00 Report number: 200701990 007 Ver 2.00 Page 1 of 30 Laboratory information Accreditation Telefication complies with the accreditation criteria for test laboratories as laid down in ISO/IEC 17025:2017. The accreditation covers the quality system of the laboratory as well as the specific activities as described in the authorized annex bearing the accreditation number L021 and is granted on 30 November 1990 by the Dutch Council For Accreditation (RvA: Raad voor Accreditatie). Telefication is designated by the FCC as an Accredited Test Firm for compliance testing of equipment subject to Certification under Parts 15 & 18. The Designation number is: NL0001. Telefication is a Wireless Device Testing laboratory recognized by Innovation, Science and Economic Development Canada to test to Canadian radio equipment requirements. Telefication is a registered Conformity Assessment body (CAB) under the Japan-EC MRA (Agreement on Mutual Recognition between Japan and the European Community). The registration number is: 201. Documentation The test report must always be reproduced in full; reproduction of an excerpt only is subject to written approval of the testing laboratory. The documentation of the testing performed on the tested devices is archived for 10 years at Telefication Netherlands. Testing Location Test Site Kiwa Telefication BV Test Site location Wilmersdorf 50 7327 AC Apeldoorn The Netherlands Tel. +31 88998 3393 Test Site FCC NL0001 Report number: 200701990 007 Ver 2.00 Page 2 of 30 Revision History Version Date Remarks By v0.50 06/04/2021 First draft K.K. v1.00 28-05-2021 Initial release version RvB v2.00 04-07-2022 Implemented comments RvB Report number: 200701990 007 Ver 2.00 Page 3 of 30 Table of Contents Revision History ............................................................................................................................................... 2 Summary of Test results .................................................................................................................................. 5 1 General Description ................................................................................................................................. 6 1.1 Applicant ............................................................................................................................................... 6 1.2 Manufacturer ........................................................................................................................................ 6 1.3 Tested Equipment Under Test (EUT) ..................................................................................................... 6 1.4 Product specifications of Equipment under test ................................................................................... 7 1.5 Environmental conditions ..................................................................................................................... 7 1.6 Measurement standards ....................................................................................................................... 7 1.7 Applicable standards ............................................................................................................................. 7 1.8 Observation and remarks ...................................................................................................................... 7 1.9 Conclusions ........................................................................................................................................... 8 2 Test configuration of the Equipment Under Test ...................................................................................... 9 2.1 Test mode ............................................................................................................................................. 9 2.2 Tested channels and Data rates ............................................................................................................ 9 2.3 Test setups ............................................................................................................................................ 9 2.4 Equipment used in the test configuration .......................................................................................... 10 2.5 Sample calculations ............................................................................................................................. 10 3 Test results ............................................................................................................................................. 11 3.1 Radiated spurious emissions ............................................................................................................... 11 3.1.1 Limit ................................................................................................................................................ 11 3.1.2 Measurement instruments ............................................................................................................. 11 3.1.3 Test setup ....................................................................................................................................... 11 3.1.4 Test procedure ................................................................................................................................ 11 3.1.5 Measurement Uncertainty ............................................................................................................. 11 3.1.6 Plots of the Radiated Spurious Emissions Measurement ............................................................... 12 3.2 6dB bandwidth Measurement ............................................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Page 1 of 3 Test Setup Photo Module Product name : Rootzone Sensor Applicant : Rockwool BV FCC ID : 2AUKP-RZ002 ISED ID : 25447-RZ002 Test report No. 200701990 Test report No. 200701990 Page 1 of 3 Contents 1 Test Setup Photos .................................................................................................................................... 2 1.1 Radiated emissions measurement 9 kHz – 30 MHz .............................................................................. 2 1.2 Radiated emissions measurement 30 – 1000 MHz ............................................................................... 2 1.3 Radiated emissions measurement 1 – 18 GHz ...................................................................................... 3 1.4 Radiated emissions measurement 18 - 26 GHz..................................................................................... 3 Test report No. 200701990 Page 2 of 3 1 Test Setup Photos 1.1 Radiated emissions measurement 9 kHz – 30 MHz 1.2 Radiated emissions measurement 30 – 1000 MHz Test report No. 200701990 Page 3 of 3 1.3 Radiated emissions measurement 1 – 18 GHz 1.4 Radiated emissions measurement 18 - 26 GHz

Contact Information

Applicant

Paul Bouwens
[email protected]+31475353535Fax: --

Technical Contact

ROCKWOOL B.V. / Grodanpaul bouwens
[email protected]31 475 353846

Industrieweg 15 Roermond · Netherlands

Non-Technical Contact

ROCKWOOL B.V. / Grodanpaul bouwens
[email protected]31 475 353846

Test Firm

Kiwa Nederland B.V.Willem Jong
[email protected]+31 889983621

Technical Specifications

#Rule PartsFrequency RangePower Output
215C902 MHz - 928 MHz1.30 mW
Confidentiality
Long Term
Grant Notes
Power output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from ROCKWOOL B.V. / Grodan

Wireless climate sensor - FCC ID 2AUKP-CLC001 - ROCKWOOL B.V. / Grodan
2AUKP-CLC001

Wireless climate sensor

Jan 08, 2020

Equipment Class

DTS - Digital Transmission System