Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
ShenzhenEviewGPSTechnology AttestationStatements NotCoveredEntityApplicant&NotCoveredEquipment To:FederalCommunicationsCommissionDate:Mar.26,26 7435OaklandMillsRoad, Columbia,MD21046,USA Ref:InformationRequiredbySection2.911(d)(5)(i)&(ii) FCCID:2AUMJ-W107X-V ShenzhenEviewGPSTechnology(“theapplicant”)certifiesthat,asofthedateofthefilingof theapplication,theapplicantisnotidentifiedontheCoveredList,establishedpursuantto§1.50002of referencechapter,asanentityproducing“covered”communicationequipment.Theequipmentfor whichauthorizationissoughtisnot“covered”telecommunicationsequipmentandvideosurveillance equipmentproducedbyentitiesidentifiedontheCommission’sCoveredListthatprohibitedfrom receivinganequipmentauthorizationpursuanttosection§2.903oftheFCCrules. Sincerelyyours, ApplicantSignature PrintedName:BellaWang Title:Manager Address:Rm201,building1-A,NankechuangYuangu,Dalang,LonghuaDistrict,Shenzhen,China Tel:86-15899795842 Email:[email protected]
ShenzhenEviewGPSTechnology 1|Page AttestationStatements To:FederalCommunicationsCommissionDate:Mar.26,26 7435OaklandMillsRoad, Columbia,MD21046,USA Subject:AttestationofCompliancewithFCCCoveredListSoftwareRequirements FCCID:[2AUMJ-W107X-V] ProductName:[PersonalMobileAlarmSystem] Thisletterservesasanattestationthattheequipmentidentifiedabove☐is/☒isnot(selectone)"covered" softwareasdefinedundertheFederalCommunicationsCommission(FCC)CoveredListrequirements,as outlinedinFCC22-84andKDB986446. Specifically,theundersignedcertifiesthattheequipmentforwhichauthorizationissought: 1.Doesnotcontaincybersecurityoranti-virussoftwareproducedorprovidedbyKasperskyLab, Inc.oranyofitssuccessors,assignees,parents,subsidiaries,affiliates,oranyentitythathasrebranded orrelabeledsoftwareproducedbytheaforementionedentities. 2.Doesnothavethecapabilitytostore,run,ordeliveranysoftwareidentifiedontheFCCCoveredList, includingbutnotlimitedtocybersecurityandanti-virussoftware. Tosupportthisattestation,theappendixevaluationdocumentationhasbeenpreparedandisincludedinthe certificationfiling. Thisattestationisbasedonathoroughevaluationofthedevice'sdesign,functionality,andsoftware environment.Theundersignedaffirmsthattheinformationprovidedisaccurateandcompletetothebestof theirknowledge. Sincerelyyours, ApplicantSignature PrintedName:BellaWang Title:Manager Address:Rm201,building1-A,NankechuangYuangu,Dalang,LonghuaDistrict,Shenzhen,China Tel:86-15899795842 Email:[email protected] ShenzhenEviewGPSTechnology 2|Page EvaluationregardingtotheCoveredListSoftware: Compliance Methodology EvaluationProcessResults Deviceis Inherent compliance ☒ TheChipset(s)usedislimitedtorun theCybersecurityoranti-virus software. Compliance ☒ TheMemoryusedislimitedtorunthe Cybersecurityoranti-virussoftware. Compliance ☒ Thereisstoragecapacitylimitationfor storeorinstalltheCybersecurityor anti-virussoftware. Compliance ☒ Operatingsystemusedislimitedto run,installordelivertheCybersecurity oranti-virussoftware. Compliance Deviceisnot Inherent compliance ☐ EvaluationBasedonSoftware BillofMaterials(SBoM) Seeattached“SBoM“ Note:TheSBoMcontentislimited tothescopeofcoveredlist software(e.g.antivirusand cybersecuritysoftware). ☐ EvaluationBasedonScanfor Softwareonthedevice ☐ EvaluationBasedonFilesystemscan ☐ EvaluationBasedonRunning softwarecheck
ShenzhenEviewGPSTechnology (March25,2026) FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Subject:ConfidentialityRequestfor:FCCID:2AUMJ-W107X-V PursuanttoSections0.457and0.459oftheCommission’sRules,weherebyrequestpermanent confidentialtreatmentoftheexhibitsaccompanyingthiscertificationapplicationasoutlinedbelow: BlockDiagram Schematics Bom OperationalDescription TuneupProcedurer Theaboveexhibitscontaintradesecretsand/orproprietaryinformationthatarenotpubliclyavailableand materialsthattheApplicanthasspentconsiderableeffortsindeveloping.Publicdisclosureofthesemay beharmfultotheApplicantandgiveanunfairadvantagetocompetitorsonthemarket. PursuanttoDA04-1705,theapplicantalsorequeststemporaryconfidentialtreatmentoftheexhibits outlinedbelowforaperiodof(upto180)daysfromthedateofequipmentauthorizationandpriorto marketingintheUnitedStatestopreventtheprematurereleaseofanysensitiveinformation.Applicantis awareoftheirresponsibilitytonotifyDERYCOMintheeventinformationregardingtheproductorthe productismadeavailabletothepublicbeforetherequestedperiodhasexpired. ExternalPhotos InternalPhotos TestSetupPhotos UserManual Sincerely, (Signature) PrintedName:BellaWang Title:Manager Address:Rm201,building1-A,NankechuangYuangu,Dalang,LonghuaDistrict,Shenzhen,China Tel:86-15899795842 Email:[email protected]
ShenzhenEviewGPSTechnology (March25,2026) FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Subject:AgentAuthorizationforFCCID:2AUMJ-W107X-V I,theundersigned,herebyauthorize( BTFTestingLab(Shenzhen)Co.,Ltd. )toactonour behalfinallmattersrelatingtothisapplicationforequipmentcertification. Anyactcarriedoutby(BTFTestingLab(Shenzhen)Co.,Ltd.)shallhavethesameeffectas ourownandIacknowledgethatallresponsibilityforcomplyingwiththetermsandconditionsof certification,asspecifiedbyDERYCOMCERTIFICATIONSERVICES,INC.,stillresideswith (ShenzhenEviewGPSTechnology). WecertifythatwearenotsubjecttoadenialoffederalbenefitsthatincludesFCCbenefitspursuantto Section5301oftheAnti-DrugAbuseActof1988,21U.S.C.§862,andthatnopartytotheapplication,as definedin47CFR§1.2002(b),issubjecttoadenialoffederalbenefitsthatincludesFCCbenefits pursuanttothatsection. Sincerely, (Signature) (FullnameofcontactpersonlistedonFCC’swebsite)BellaWang (Title)Manager Tel:86-15899795842 Email:[email protected]
Label&Location LabelSize:50mm*10mm
TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page 1 of 59 BTFTestingLab(Shenzhen)Co.,Ltd. Plant101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen,Guangdong,China SARTestReport For ApplicantName:ShenzhenEviewGPSTechnology Address: Rm201,building1-A,NankechuangYuangu,Dalang,Longhua District,Shenzhen,China EUTName:PersonalMobileAlarmSystem ModelNumber:EC-W107X-V IssuedBy CompanyName:BTFTestingLab(Shenzhen)Co.,Ltd. Address: Plant101,201and301,Building1,Block2,TantouIndustrial Park,TantouCommunity,SonggangStreet,Bao'anDistrict, Shenzhen,Guangdong,China ReportNumber:BTF251103R02101 TestStandards: 47CFRPart2.1093IEEEStd.1528-2013 IEEEC95.1-2019 FCCID:2AUMJ-W107X-V TestConclusion:Pass TestDate:2025-11-16to2025-11-21 DateofIssue:2026-03-06 TestedBy: BirchZhang/Tester Date:2026-03-06 PreparedBy: AmendaZhong/ProjectEngineer Date:2026-03-06 ApprovedBy: Ryan.CJ/EMCManager Date:2026-03-06 Note:Allthetestresultsinthisreportonlyrelatedtothetestingsamples.Whichcanbeduplicatedcompletelyforthelegalusewithapprovalof applicant;itshallnotbereproducedexceptinfullwithoutthewrittenapprovalofBTFTestingLab(Shenzhen)Co.,Ltd.,Alltheobjectionsshouldbe raisedwithinthirtydaysfromthedateofissue.Tovalidatethereport,youcancontactus. TestReportNumber:BTF251103R02101 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page 2 of 59 BTFTestingLab(Shenzhen)Co.,Ltd. Plant101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen,Guangdong,China RevisionHistory VersionIssueDateRevisionsContent R_V02026-03-06Original Note:Oncetherevisionhasbeenmade,thenpreviousversionsreportsareinvalid. TestReportNumber:BTF251103R02101 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page 3 of 59 BTFTestingLab(Shenzhen)Co.,Ltd. Plant101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen,Guangdong,China TableofContents 1.Introduction...............................................................................................................................................................................4 1.1IdentificationofTestingLaboratory.................................................................................................................................4 1.2IdentificationoftheResponsibleTestingLocation..........................................................................................................4 1.3LaboratoryCondition.......................................................................................................................................................4 1.4Announcement................................................................................................................................................................4 2.ProductInformation..................................................................................................................................................................5 2.1ApplicationInformation....................................................................................................................................................5 2.2ManufacturerInformation................................................................................................................................................5 2.3FactoryInformation.........................................................................................................................................................5 2.4GeneralDescriptionofEquipmentunderTest(EUT).....................................................................................................5 2.5EquipmentunderTestAncillaryEquipment....................................................................................................................5 2.6TechnicalInformation......................................................................................................................................................5 3.SummaryofTestResults.........................................................................................................................................................6 3.1TestStandards................................................................................................................................................................6 3.2DeviceCategoryandSARLimit......................................................................................................................................7 3.3TestResultSummary......................................................................................................................................................7 3.4TestUncertainty..............................................................................................................................................................8 4.MeasurementSystem.............................................................................................................................................................10 4.1SpecificAbsorptionRate(SAR)Definition....................................................................................................................10 4.2MVGSARSystem.........................................................................................................................................................10 5.SystemVerification.................................................................................................................................................................15 5.1PurposeofSystemCheck.............................................................................................................................................15 5.2SystemCheckSetup...............................................................................................................................................…
Text truncated - open the document above for the full version.
Page: 1/11 Ref : ACR.9.6.25.BES.B Cancel and replace the report ACR.9.6.25.BES.A BTF TESTING LAB (SHENZHEN) CO., LTD. F101,201 AND 301, BUILDING 1, BLOCK 2, TANTOU INDUSTRIAL PARK, TANTOU COMMUNITY SONGGANG STREET, BAO'AN DISTRICT, SHENZHEN, CHINA MVG COMOSAR DOSIMETRIC E-FIELD PROBE SERIAL NO.: 0125-EPGO-445 Calibrated at MVG Z.I. de la pointe du diable Technopôle Brest Iroise – 295 avenue Alexis de Rochon 29280 PLOUZANE - FRANCE Calibration date: 01/02/2025 Accreditations #2-6789 Scope available on www.cofrac.fr The use of the Cofrac brand and the accreditation references is prohibited from any reproduction. Summary: This document presents the method and results from an accredited COMOSAR Dosimetric E-Field Probe calibration performed at MVG, using the CALIPROBE test bench, for use with a MVG COMOSAR system only. The test results covered by accreditation are traceable to the International System of Units (SI). COMOSAR E-Field Probe Calibration Report Docusign Envelope ID: 691C3E09-7794-43A0-BF36-C536093756C8 COMOSAR E-FIELD PROBE CALIBRATION REPORT Ref: ACR.9.6.25.BES.B Page: 2/11 Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOSAR Probe vM This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. Name Function Date Signature Prepared by : Pedro Ruiz Technical Manager 1/9/2025 Checked & approved by: Pedro Ruiz Technical Manager 1/9/2025 Authorized by: Geraldine Toutain Quality Manager Customer Name Distribution : BTF Testing Lab (Shenzhen) Co., Ltd. Issue Name Date Modifications A Pedro Ruiz 1/9/2025 Initial release B Pedro Ruiz 2/12/2025 Change freq label 850 to 835 Docusign Envelope ID: 691C3E09-7794-43A0-BF36-C536093756C8 2/13/2025 COMOSAR E-FIELD PROBE CALIBRATION REPORT Ref: ACR.9.6.25.BES.B Page: 3/11 Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOSAR Probe vM This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. TABLE OF CONTENTS 1 Device Under Test ..................................................................................................... 4 2 Product Description ................................................................................................... 4 2.1 General Information _______________________________________________________ 4 3 Measurement Method ................................................................................................ 4 3.1 Sensitivity _______________________________________________________________ 4 3.2 Linearity ________________________________________________________________ 5 3.3 Isotropy _________________________________________________________________ 5 3.4 Boundary Effect __________________________________________________________ 5 3.5 Probe Modulation Response _________________________________________________ 6 4 Measurement Uncertainty .......................................................................................... 6 5 Calibration Results ..................................................................................................... 6 5.1 Calibration in air __________________________________________________________ 6 5.2 Calibration in liquid _______________________________________________________ 7 6 Verification Results ................................................................................................... 8 7 List of Equipment .................................................................................................... 10 Docusign Envelope ID: 691C3E09-7794-43A0-BF36-C536093756C8 COMOSAR E-FIELD PROBE CALIBRATION REPORT Ref: ACR.9.6.25.BES.B Page: 4/11 Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOSAR Probe vM This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. 1 DEVICE UNDER TEST Device Under Test Device Type COMOSAR DOSIMETRIC E FIELD PROBE Manufacturer MVG Model SSE2 Serial Number 0125-EPGO-445 Product Condition (new / used) New Frequency Range of Probe 0.15 GHz-7.5GHz Resistance of Three Dipoles at Connector Dipole 1: R1=0.206 M Dipole 2: R2=0.208 M Dipole 3: R3=0.226 M 2 PRODUCT DESCRIPTION 2.1 GENERAL INFORMATION MVG’s COMOSAR E field Probes are built in accordance to the IEC/IEEE 62209-1528 and FCC KDB865664 D01 standards. Figure 1 – MVG COMOSAR Dosimetric E field Probe Probe Length 330 mm Length of Individual Dipoles 2 mm Maximum external diameter 8 mm Probe Tip External Diameter 2.5 mm Distance between dipoles / probe extremity 1 mm 3 MEASUREMENT METHOD The IEC/IEEE 62209-1528 and FCC KDB865664 D01 standards provide recommended practices for the probe calibrations, including the performance characteristics of interest and methods by which to assess their effect. All calibrations / measurements performed meet the fore-mentioned standards. 3.1 SENSITIVITY The sensitivity factors of the three dipoles were determined using a two step calibration method (air and tissue simulating liquid) using waveguides as outlined in the standards for frequency range 600- 7500MHz and using the calorimeter cell method (transfer method) as outlined in the standards for frequency 150-450 MHz. Docusign Envelope ID: 691C3E09-7794-43A0-BF36-C536093756C8 COMOSAR E-FIELD PROBE CALIBRATION REPORT Ref: ACR.9.6.25.BES.B Page: 5/11 Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOSAR Probe vM This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to …
Text truncated - open the document above for the full version.
S P E C I F I C A T I O N Client Sa mp le : Eviews Projectname: W107V Antennacategory: Internal Antenna Edition:V1 .0 Date:2026.2.11 Supplieraddress:Room505-506,BlockA,DonglianBuilding,Chuangye2ndRoad,Bao'anDistrict,Shenzhen Supplier:ShenzhenCicent Communication Technology Co., Ltd. 2 Catalogue 1:PassiveTestReport.............................................................................................................................................................3 II:ActiveTestData ................................................................................................................................................................12 III:MatchingCircuit .............................................................................................................................................................13 IV:EnvironmentalManagement .........................................................................................................................................14 5:Structurediagramfile.......................................................................................................................................................15 ChangeHistoryColumn Creation/ChangeDate ReasonforchangeChangecontentEdition 2026.2.11 FirsteditionreleaseFirsteditionrelease V1.0 3 1:PassiveTestReport Passiveefficiency ofAngilentE5071Cmainantenna:(B4) B4 FrequencyProductivenessdBGainProductiveness% 1710-8.25-4.5914.95 1730-8.47-4.5014.22 1750-8.80-4.6213.17 1770-8.99-4.7112.61 1790-8.83-4.4013.10 1810-8.51-3.9814.08 1830-8.31-3.5114.75 1850-7.94-3.0716.06 1870-7.54-2.5117.64 1890-7.28-2.3318.72 1910-6.86-1.8920.62 1930-6.78-1.8421.00 1950-6.55-1.6822.11 1970-6.55-1.8422.12 1990-6.54-2.0322.20 2010-6.40-1.9322.93 2030-6.22-1.7423.90 2050-6.29-1.6323.49 2070-6.26-1.3823.68 2090-6.12-1.0424.46 2110-6.04-0.7424.87 2130-6.03-0.4624.97 2150-6.33-0.5823.27 2170-6.57-0.5422.01 1950-6.55-1.6822.11 1970-6.55-1.8422.12 1990-6.54-2.0322.20 2010-6.40-1.9322.93 2030-6.22-1.7423.90 2050-6.29-1.6323.49 2070-6.26-1.3823.68 2090-6.12-1.0424.46 2110-6.04-0.7424.87 2130-6.03-0.4624.97 2150-6.33-0.5823.27 2170-6.57-0.5422.01 4 Antenna3DDirectionPattern Antenna2Dpa- tternTheta=90 ° Phi=90° 5 Phi=0° Passiveefficiencyofmainantenna:(B2) B2 FrequencyProductivenessdBGain Productiveness% 1850-7.94-3.0716.06 1870-7.54-2.5117.64 1890-7.28-2.3318.72 1910-6.86-1.8920.62 1930-6.78-1.8421.00 1950-6.55-1.6822.11 1970-6.55-1.8422.12 1990-6.54-2.0322.20 Antenna3DDirectionPattern 6 Antenna2DDirectionPattern Theta= 90° Phi=90° Phi=0° 7 Passiveefficiencyofmainantenna:(B13) B13 FrequencyProductivenessdBGain Productiveness% 749-10.94-5.568.06 759-11.11-5.697.74 769-11.36-5.937.31 779-11.71-6.376.75 789-12.11-6.916.14 799-12.59-7.555.50 800-12.64-7.635.44 Antenna3DDirectionPattern Antenna2Dpa- tternTheta=90 ° 8 Phi=90° Phi=0° 9 WIFI/BTantennapassiveefficiency: WIFI FrequencyProductivenessdBGainProductiveness% 2400-5.58-1.4927.64 2410-5.54-1.3427.95 2420-5.52-1.2528.08 2430-5.56-1.2127.77 2440-5.65-1.2527.25 2450-5.71-1.2926.86 2460-5.83-1.3026.13 2470-6.03-1.4024.93 2480-6.16-1.4024.22 2490-6.37-1.5623.06 2500-6.43-1.6222.73 Antenna3DDirectionPattern Antenna2Dpa- tternTheta=90 ° 10 Phi=90° Phi=0° GPSantennapassiveefficiency: GPS FrequencyProductivenessdBGainProductiveness% 1550-10.46-6.009.00 1555-10.33-5.899.28 1560-10.21 -5.79 9.52 1565-10.07-5.639.85 1570-9.93-5.4710.15 1575-9.83-5.3510.40 1580-9.75-5.2810.59 1585-9.71-5.2810.68 1590-9.68-5.2410.78 1595-9.64-5.1810.86 1600-9.62-5.2010.91 11 Antenna3DDirectionPattern Antenna2Dpa- tternTheta=90 ° Phi=90° 12 Phi=0° II:ActiveTestData ArmmodelChannelTRP(dBm)TIS(dBm) FDD B2 CH 1865015.2 CH 1890015.2 CH 1915015.4-87.6 FDD B4 CH 2000014.8 CH 2017514.9 CH 2035014.9-87.5 FDD B13 CH 23230 9.7 -84.5 OTAStandardChamber 13 III:MatchingCircuit Mainantennamatchingcircuit: WIFI/BTantennamatchingcircuit: GPSantennamatchingcircuit: 14 IV:EnvironmentalManagement 15 5:StructureDiagramFile
ReportNumber:BTF251103R01901 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page1of57 BTFTestingLab(Shenzhen)Co.,Ltd. Plant101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen, Guangdong,China Email:[email protected]:+86-755-23146130http://www.btf-lab.comVersion:1/00 Appendix-2.4GWIFI 1.DutyCycle 1.1TestResult 1.1.1Ant1 Ant1 Mode TX Type Frequency (MHz) T_on (ms) Period (ms) DutyCycle (%) DutyCycle CorrectionFactor(dB) Max.DC Variation(%) 802.11bSISO 24121.0081.09991.720.380.00 24371.0091.09991.810.370.03 24621.0091.09991.810.370.03 802.11gSISO 24120.6170.66892.370.340.03 24370.6160.66892.220.350.07 24620.6170.66892.370.340.03 802.11n (HT20) SISO 24120.6130.66492.320.350.04 24370.6130.66492.320.350.04 24620.6130.66492.320.350.04 ReportNumber:BTF251103R01901 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page2of57 BTFTestingLab(Shenzhen)Co.,Ltd. Plant101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen, Guangdong,China Email:[email protected]:+86-755-23146130http://www.btf-lab.comVersion:1/00 1.2TestGraph 1.2.1Ant1 802.11b_LCH_2412MHz_Ant1(SISO)_NTNV 802.11b_MCH_2437MHz_Ant1(SISO)_NTNV ReportNumber:BTF251103R01901 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page3of57 BTFTestingLab(Shenzhen)Co.,Ltd. Plant101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen, Guangdong,China Email:[email protected]:+86-755-23146130http://www.btf-lab.comVersion:1/00 802.11b_HCH_2462MHz_Ant1(SISO)_NTNV 802.11g_LCH_2412MHz_Ant1(SISO)_NTNV ReportNumber:BTF251103R01901 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page4of57 BTFTestingLab(Shenzhen)Co.,Ltd. Plant101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen, Guangdong,China Email:[email protected]:+86-755-23146130http://www.btf-lab.comVersion:1/00 802.11g_MCH_2437MHz_Ant1(SISO)_NTNV 802.11g_HCH_2462MHz_Ant1(SISO)_NTNV ReportNumber:BTF251103R01901 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page5of57 BTFTestingLab(Shenzhen)Co.,Ltd. Plant101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen, Guangdong,China Email:[email protected]:+86-755-23146130http://www.btf-lab.comVersion:1/00 802.11n(HT20)_LCH_2412MHz_Ant1(SISO)_NTNV 802.11n(HT20)_MCH_2437MHz_Ant1(SISO)_NTNV ReportNumber:BTF251103R01901 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page6of57 BTFTestingLab(Shenzhen)Co.,Ltd. Plant101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen, Guangdong,China Email:[email protected]:+86-755-23146130http://www.btf-lab.comVersion:1/00 802.11n(HT20)_HCH_2462MHz_Ant1(SISO)_NTNV ReportNumber:BTF251103R01901 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page7of57 BTFTestingLab(Shenzhen)Co.,Ltd. Plant101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen, Guangdong,China Email:[email protected]:+86-755-23146130http://www.btf-lab.comVersion:1/00 2.Bandwidth 2.1TestResult 2.1.1OBW Mode TX Type Frequency (MHz) ANT 99%OccupiedBandwidth(MHz) Verdict ResultLimit 802.11bSISO 2412113.125/Pass 2437113.131/Pass 2462113.125/Pass 802.11gSISO 2412118.284/Pass 2437118.331/Pass 2462118.285/Pass 802.11n (HT20) SISO 2412118.930/Pass 2437118.962/Pass 2462118.963/Pass 2.1.26dBBW Mode TX Type Frequency (MHz) ANT 6dBBandwidth(MHz) Verdict ResultLimit 802.11bSISO 2412110.076>=0.5Pass 243719.734>=0.5Pass 2462110.095>=0.5Pass 802.11gSISO 2412116.902>=0.5Pass 2437116.843>=0.5Pass 2462116.930>=0.5Pass 802.11n (HT20) SISO 2412117.754>=0.5Pass 2437117.753>=0.5Pass 2462117.744>=0.5Pass ReportNumber:BTF251103R01901 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page8of57 BTFTestingLab(Shenzhen)Co.,Ltd. Plant101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen, Guangdong,China Email:[email protected]:+86-755-23146130http://www.btf-lab.comVersion:1/00 2.2TestGraph 2.2.1OBW 802.11b_LCH_2412MHz_Ant1(SISO)_NTNV 802.11b_MCH_2437MHz_Ant1(SISO)_NTNV ReportNumber:BTF251103R01901 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page9of57 BTFTestingLab(Shenzhen)Co.,Ltd. Plant101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen, Guangdong,China Email:[email protected]:+86-755-23146130http://www.btf-lab.comVersion:1/00 802.11b_HCH_2462MHz_Ant1(SISO)_NTNV 802.11g_LCH_2412MHz_Ant1(SISO)_NTNV ReportNumber:BTF251103R01901 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page10of57 BTFTestingLab(Shenzhen)Co.,Ltd. Plant101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen, Guangdong,China Email:[email protected]:+86-755-23146130http://www.btf-lab.comVersion:1/00 802.11g_MCH_2437MHz_Ant1(SISO)_NTNV 802.11g_HCH_2462MHz_Ant1(SISO)_NTNV ReportNumber:BTF251103R01901 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page11of57 BTFTestingLab(Shenzhen)Co.,Ltd. Plant101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen, Guangdong,China Email:[email protected]:+86-755-23146130http://www.btf-lab.comVersion:1/00 802.11n(HT20)_LCH_2412MHz_Ant1(SISO)_NTNV 802.11n(HT20)_MCH_2437MHz_Ant1(SISO)_NTNV ReportNumber:BTF251103R01901 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page12of57 BTFTestingLab(Shenzhen)Co.,Ltd. Plant101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,Son…
Text truncated - open the document above for the full version.
ReportNumber:BTF251103R01902 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page1of38 BTFTestingLab(Shenzhen)Co.,Ltd. Plant101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen, Guangdong,China Email:[email protected]:+86-755-23146130http://www.btf-lab.comVersion:1/00 Appendix-BLE 1.DutyCycle 1.1TestResult 1.1.1Ant1 Ant1 Mode TX Type Frequency (MHz) T_on (ms) Period (ms) DutyCycle (%) DutyCycle CorrectionFactor(dB) Max.DC Variation(%) 1MSISO 24022.1792.50087.160.600.06 24402.1802.50087.200.590.03 24802.1802.50087.200.590.03 2MSISO 24021.1221.87559.842.230.03 24401.1231.87559.892.230.03 24801.1221.87559.842.230.05 ReportNumber:BTF251103R01902 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page2of38 BTFTestingLab(Shenzhen)Co.,Ltd. Plant101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen, Guangdong,China Email:[email protected]:+86-755-23146130http://www.btf-lab.comVersion:1/00 1.2TestGraph 1.2.1Ant1 1M_LCH_2402MHz_Ant1_NTNV 1M_MCH_2440MHz_Ant1_NTNV ReportNumber:BTF251103R01902 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page3of38 BTFTestingLab(Shenzhen)Co.,Ltd. Plant101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen, Guangdong,China Email:[email protected]:+86-755-23146130http://www.btf-lab.comVersion:1/00 1M_HCH_2480MHz_Ant1_NTNV 2M_LCH_2402MHz_Ant1_NTNV ReportNumber:BTF251103R01902 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page4of38 BTFTestingLab(Shenzhen)Co.,Ltd. Plant101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen, Guangdong,China Email:[email protected]:+86-755-23146130http://www.btf-lab.comVersion:1/00 2M_MCH_2440MHz_Ant1_NTNV 2M_HCH_2480MHz_Ant1_NTNV ReportNumber:BTF251103R01902 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page5of38 BTFTestingLab(Shenzhen)Co.,Ltd. Plant101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen, Guangdong,China Email:[email protected]:+86-755-23146130http://www.btf-lab.comVersion:1/00 2.Band…
Text truncated - open the document above for the full version.
19 GEORGETOWN · IRVINE, California, 92612 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 700.00 µW |
| 2 | 15C | 2.41 GHz - 2.46 GHz | 61.00 mW |
Personal Mobile Alarm System
Equipment Class
DTS - Digital Transmission SystemPersonal Mobile Alarm System
Equipment Class
DTS - Digital Transmission SystemCharging base
Equipment Class
DXX - Part 15 Low Power Communication Device TransmitterPersonal Mobile Alarm System
Equipment Class
PCB - PCS Licensed TransmitterPersonal Mobile Alarm System
Equipment Class
DTS - Digital Transmission System