Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Ledlenser GmbH & Co. KG Kronenstr. 5-7, D-42699 Solingen Fest: +49 212 5948 0 Fax: +49 212 5948 200 E-Mail: [email protected] HRA 23078 Amtsgericht Wuppertal UstId Nr. : DE815242425 Personally liable partner: Ledlenser Beteiligungs GmbH Firmensitz: Solingen HRB 24774 Amtsgericht Wuppertal Managing Director: Michael Reuter, Kai Milewski Volksbank im Bergischen Land e.G IBAN: DE46 3406 0094 0006 2496 76 BIC: VBRSDE33XXX Deutsche Bank AG IBAN: DE21 3427 0094 0111 0741 00 BIC: DEUTDEDW342 WEEE-Reg.-Nr. DE 20612570 Delivery and payment conditions according to our terms and conditions. With regard to the fee reduction, we refer to the current payment and condition agreements. The delivered goods remain our property until they have been paid for in full. The place of performance and jurisdiction is Solingen. Ledlenser GmbH&Co.KG Your contact: Peter Bahner Phone: +49 212 5948-2953 E-Mail: [email protected] 24.1.2024 Attestation Statement according to 2.911(d)(5)(i) and 2.911(d)(5)(ii) FCC ID: 2AUMP-XP30R FRN: 0028818664 TO WHOM IT MAY CONCERN: Hereby we certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Further we certify that, as of the date of the filing of the application, Ledlenser GmbH & Co. KG is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, __________________________________ Peter Bahner Ledlenser GmbH & Co. KG Kronenstraße 5 - 7, DE-42699 Solingen, Germany FRN: 0028818664 Phone: +49 212 5948-2953 E-Mail: [email protected] Ledlenser GmbH & Co. KG Kronenstraße 5 - 7, DE-42699 Solingen Federal Communication Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA
Ledlenser GmbH & Co. KG Kronenstr. 5-7, D-42699 Solingen Fest: +49 212 5948 0 Fax: +49 212 5948 200 E-Mail: [email protected] HRA 23078 Amtsgericht Wuppertal UstId Nr. : DE815242425 Personally liable partner: Ledlenser Beteiligungs GmbH Firmensitz: Solingen HRB 24774 Amtsgericht Wuppertal Managing Director: Michael Reuter, Kai Milewski Volksbank im Bergischen Land e.G IBAN: DE46 3406 0094 0006 2496 76 BIC: VBRSDE33XXX Deutsche Bank AG IBAN: DE21 3427 0094 0111 0741 00 BIC: DEUTDEDW342 WEEE-Reg.-Nr. DE 20612570 Delivery and payment conditions according to our terms and conditions. With regard to the fee reduction, we refer to the current payment and condition agreements. The delivered goods remain our property until they have been paid for in full. The place of performance and jurisdiction is Solingen. Ledlenser GmbH&Co.KG Your contact: Peter Bahner Phone: +49 212 5948-2953 E-Mail: [email protected] 24.1.2024 Attestation Statement according to 2.911(d)(7) FCC ID: 2AUMP-XP30R FRN: 0028818664 TO WHOM IT MAY CONCERN: We, Ledlenser GmbH & Co. KG designate Ledlenser Inc. to act as U.S. agent for service of process. Ledlenser Inc. hereby acknowledges the obligation of the U.S. agent for service of process. Further Ledlenser GmbH & Co. KG accepts to maintain an agent for no less than one year after the grantee has terminated all mar- keting and importation or the conclusion of any Commission-related proceeding involving the equipment. Sincerely, __________________________________ ________________________________ Peter Bahner Jeff Hutchens Ledlenser GmbH & Co. KG Ledlenser Inc. Kronenstraße 5 - 7, DE-42699 Solingen, Germany 80 SE Madison St, Suite 130, Portland, OR, 97214 FRN: 0028818664 FRN: 0034380865 Phone: +49 212 5948-2953 Phone: 503-688-1951 E-Mail: [email protected] Email: [email protected] Ledlenser GmbH & Co. KG Kronenstraße 5 - 7, DE-42699 Solingen Federal Communication Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA
CONFIDENTIALITY REQUEST for Certification Service in USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 2024-1-24 TO WHOM IT MAY CONCERN Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b) (4) of the Freedom of Information Act, we request confidentiality for the following products: FCC ID Model name 2AUMP-XP30R XP30R For the product stated above, we request that the following information be held confidential; Exhibits Long-Term Confidentiality Short-Term Confidentiality Short-Term Confidentiality Days External Photos Internal Photos Block Diagram Schematics Test Setup Photos User’s Manual Parts List Tune Up Operational Descriptions The long-term confidentiality exhibits contain our trade secrets and proprietary information that could be of benefit to our competitors. The short-term confidentiality on the basis of ensuring that business sensitive information remains confidential until the actual marketing of our new device. If you have any questions, please feel free to contact me at the address shown below. Sincerely, (Signed) Name / Title: Mr. Peter Bahner Company: Ledlenser GmbH & Co. KG Address: Kronenstraße 5-7 | 42699 Solingen | Germany Phone: +49 212 5948 2953 Fax: - E-Mail: [email protected]
The test results relate only to the individual items which have been tested. This report shall not be reproduced in parts without the written approval of the testing laboratory © Copyright: All rights reserved by CETECOM Annex 3: External photographs to Test Report 21-1-0007001T04a-C1 Number of pages: 4 Date of Report: 2024-Feb-07 Testing company: cetecom advanced GmbH Untertuerkheimer Str. 6-10 66117 Saarbruecken GERMANY Applicant: Ledlenser GmbH & Co. KG Test Object / Tested Device(s): Portable LED lamp XP30R FCC ID: 2AUMP-XP30R ISED ID: -- Testing has been carried out in accordance with: Title 47 CFR, Chapter I FCC Regulations, Subchapter A Subpart B: §15.109 (Class B limits) ISED Regulations ICES-003, Issue 6 (Class B limits) Deviations, modifications or clarifications (if any) to above mentioned documents are written in each section under "Test method and limit". Test Report 21-1-0007001T04a-C1-A3 CETECOM-TR21-1-0007001T04a-C1-A3 2 / 4 Table of Contents 1External photographs of Main device under test (EUT/DUT) ..................................................................................................3 2External photographs of Accessories .......................................................................................................................................4 Test Report 21-1-0007001T04a-C1-A3 CETECOM-TR21-1-0007001T04a-C1-A3 3 / 4 1External photographs of Main device under test (EUT/DUT) Photograph 1: EUT 1_Top view Photograph 2: EUT 1_left side view Test Report 21-1-0007001T04a-C1-A3 CETECOM-TR21-1-0007001T04a-C1-A3 4 / 4 2External photographs of Accessories Photograph 3: AE1 End Of Annex 3
XP30R – External Photos FCC ID 2AUMP-XP30R Serial No.
FCC ID 2AUMP-XP30R Serial No. XP30R Label Position Ledlenser GmbH & Co. KG | Kronenstr 5-7 42966 Solingen | Germany Ledlenser UK Ltd | Kingswick House Sunninghill | SL7BH | UK This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC Statement
Driver Unit Location UI Unit Location XP30R – Internal Photos UI Unit Receiver Antenna Driver Unit
The test results relate only to the individual items which have been tested. This report shall not be reproduced in parts without the written approval of the testing laboratory © Copyright: All rights reserved by CETECOM Annex 1: Measurement diagrams to Test Report 21-1-0007001T04a-C1 Number of pages: 4 Date of Report: 2024-Feb-07 Testing company: cetecom advanced GmbH Untertuerkheimer Str. 6-10 66117 Saarbruecken GERMANY Applicant: Ledlenser GmbH & Co. KG Test Object / Tested Device(s): Portable LED lamp XP30R FCC ID: 2AUMP-XP30R ISED ID: -- Testing has been carried out in accordance with: Title 47 CFR, Chapter I FCC Regulations, Subchapter A Subpart B: §15.109 (Class B limits) ISED Regulations ICES-003, Issue 6 (Class B limits) Deviations, modifications or clarifications (if any) to above mentioned documents are written in each section under "Test method and limit". Test Report 21-1-0007001T04a-C1-A1 CETECOM-TR21-1-0007001T04a-C1-A1 2 / 4 1Measurement diagrams 3.01 Common Information Test Description: Radiated field strength emission in 3m distance Test Site: CETECOM GmbH Essen Test Standard: FCC 15.109 Unintentional Radiator Antenna polarisation: horizontal/vertical Operating Mode: Op. mode 1 Environmental Conditions:: Humidity :39 %rH; Temperature: 21°C Operator: Mar Verdict: Passed EUT Information PMT number: 21-1-00070S02_C01 Manufacturer: Ledlenser GmbH & Co. KG Final_Result Frequency (MHz) QuasiPeak (dBμV/m) Limit (dBμV/m) Margi n (dB) Meas. Time (ms) Bandwidt h (kHz) Heigh t (cm) PolAzimut h (deg) Corr. (dB/m) 795.665000 33.14 46.00 12.86 1000.0 120.000 269.0 V 246.0 25.2 0 5 10 15 20 25 30 35 40 45 50 55 60 30M 5060 80 100M200300400 500 8001G L e v e l i n d B μ V / m Frequency in Hz Full Spectrum FCC15.109 QP Class B Test Report 21-1-0007001T04a-C1-A1 CETECOM-TR21-1-0007001T04a-C1-A1 3 / 4 4.01 Common Information Test Description: Radiated Filed Strength Emission Test Site Location: CETECOM GmbH Essen Test Site: Fully Anechoic Chamber (FAC1) - EMC32 V10.60.20 Test Standard: FCC Part 15.109, class B / RSS-Gen., Issue 4 Operating Mode: Op. mode 1 Equipment Class: Class B Environmental Conditions:: Humidity : 40%rH; Temperature: 20°C Operator: HLa EUT Setup: 1 Verdict: Passed EUT Information PMT number: 21-1-00070S03_C01 Manufacturer: Ledlenser GmbH & Co. KG Final_Result Frequency (MHz) MaxPeak (dBμV/m) Limit (dBμV/ m) Margin (dB) Meas. Time (ms) Bandwidth (kHz) PolAzimuth (deg) Elevation (deg) Corr. (dB/m) 2310.460000 57.97 74.00 16.03 100.0 1000.000 H 280.0 0.0 38 2317.100000 --- 54.00 7.91 100.0 1000.000 V 157.0 0.0 38 15 20 30 40 50 60 70 80 85 1G2G3G4G5G6 8 10G15G L e v e l i n d B μ V / m Frequency in Hz Full Spectrum 14,726400000 GHz 64,277 dBμV/m 14,749600000 GHz 52,269 dBμV/m Test Report 21-1-0007001T04a-C1-A1 CETECOM-TR21-1-0007001T04a-C1-A1 4 / 4 4.02 Common Information Test Description: Radiated Filed Strength Emission Test Site Location: CETECOM GmbH Essen Test Site: Fully Anechoic Chamber (FAC1) - EMC32 V10.60.20 Test Standard: FCC Part 15.109, class B / RSS-Gen., Issue 4 Operating Mode: Op. mode 1 Equipment Class: Class B Environmental Conditions:: Humidity : 40%rH; Temperature: 20°C Operator: HLa EUT Setup: 1 Verdict: Passed EUT Information PMT number: 21-1-00070S03_C01 Manufacturer: Ledlenser GmbH & Co. KG End Of Annex 1
The test results relate only to the individual items which have been tested. This report shall not be reproduced in parts without the written approval of the testing laboratory © Copyright: All rights reserved by CETECOM Annex 4: Test setup photographs to Test Report 21-1-0007001T04a-C1 Number of pages: 3 Date of Report: 2024-Feb-07 Testing company: cetecom advanced GmbH Untertuerkheimer Str. 6-10 66117 Saarbruecken GERMANY Applicant: Ledlenser GmbH & Co. KG Test Object / Tested Device(s): Portable LED lamp XP30R Contains FCC ID: 2AUMP-XP30R Contains IC ID: -- Testing has been carried out in accordance with: Title 47 CFR, Chapter I FCC Regulations, Subchapter A Subpart B: §15.109 (Class B limits) ISED Regulations ICES-003, Issue 6 (Class B limits) Deviations, modifications or clarifications (if any) to above mentioned documents are written in each section under "Test method and limit". Test Report 21-1-0007001T04a-C1-A4 CETECOM-TR21-1-0007001T04a-C1-A4 2 / 3 1Test setup photographs Photograph 1: EUT Test Setup in the semi anechoic chamber, Electric Field Strength Photograph 2: EUT Test Setup in the semi anechoic chamber, Electric Field Strength strength Test Report 21-1-0007001T04a-C1-A4 CETECOM-TR21-1-0007001T04a-C1-A4 3 / 3 Photograph 3: EUT Test Setup in the fully anechoic chamber, Electric Field Strength Photograph 4: EUT Test Setup in the fully anechoic chamber, Electric Field Strength End Of Annex 4
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | - | - |

LEDLENSER
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter