Application Details

Equipment Class
PCB - PCS Licensed Transmitter
Date of Grant
May 27, 2020
Application Purpose
Original Equipment
Date of Application
May 27, 2020
Equipment Note
3GUMTX Bridge to 4G LTE
Frequency Range
871.40000000 - 891.60000000
Company
ADT, Inc
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

CB34U Gateway Quick Start Guide 1) Place the Unit In order to ensure proper communication with the existing 3G Alarm Panel, find a suitable location for the CB34U Gateway by following the placement installation guidelines below: •Within the residence, in an elevated location approximately 3-6 feet above the ground, such as on top of a shelf or cabinet •On a flat surface, with the 4 LED indicators and Silence button pointing upwards towards the ceiling •Within approximately 50 feet of the existing Alarm Panel •In a location that ensures the device can remain permanently located/undisturbed, and accessible only when necessary •Within reach of an electrical outlet NOTE: Do not connect to a receptacle that is controlled by a switch Introduction The CB34U Gateway is a plug-and-play solution that provides upgraded LTE connectivity to an existing 3G-based Alarm Panel. This CB34U Gateway has been pre-programmed at the factory with the specific CellBounce network parameters and credentials required to seamlessly set itself up and communicate with the LTE network and Central Station. The simple installation process only requires the end-user to plug the CB34U into a working power outlet. After successful installation, all features and functionalities of the existing Alarm Panel will remain and the CB34U Gateway will relay information to and from the Alarm Panel to the LTE network. 2) Begin Self Installation 1.Connect the CB34U AC Adaptor to a power outlet 2.Upon plugging in the device, it will go through a self- installation process. The Power and Status LEDs will turn Green 3.After approximately 60 seconds, the 3G and 4G LTE LEDs will begin blinking Yellow. This shows that the device is establishing connectivity to the existing Alarm Panel and the 4G LTE network. 4.Wait until the 3G and 4G LTE LEDs both turn Green • If both LEDs turn Green, the CB34U Gateway has completed the installation process and is connected for normal operation • If either 3G or 4G LTE LEDs turn Red, visit the Troubleshooting section of this Quick Start Guide • If either 3G or 4G LTE LEDs remain blinking Yellow for more than 10 minutes after plugging in the device, visit the Troubleshooting section of this Quick Start Guide 3) LED User Interface and Audible Alerts LED #1 Power Status ConditionLED IndicationAudible Indication Power OKSolid GreenN/A Power Lost (running on battery)Yellow slow blinkOnce every 60 seconds Power Lost (running on battery silenced)Red slow blinkOff LED #2 4G LTE Signal & Connectivity ConditionLED IndicationAudible Indication Connected to AT&T NetworkSolid GreenN/A Transmitting/Receiving data Green slow blinkN/A Not Connected to AT&T NetworkSolid RedOnce per minute Not Connected to AT&T Network (silenced)Red Slow BlinkOff LTE has low signal qualityYellow slow blinkN/A Power Lost (running on battery)OffN/A LED #3 3G Signal & Connectivity ConditionLED IndicationAudible Indication Connected to Alarm PanelSolid GreenN/A Not Connected to Alarm Panel Solid RedN/A Transmitting/Receiving data Green slow BlinkN/A BroadcastingYellow slow blinkN/A Power Lost (running on battery)OffN/A LED #4 Status & Trouble Conditions ConditionLED IndicationAudible Indication No TroubleSolid GreenN/A No Trouble - Power Lost (running on battery)OffN/A Tamper Solid YellowOnce every 10 seconds Tamper Silenced Yellow slow blinkOff Low Battery/battery disconnected Solid RedOnce every 10 seconds Low Battery SilencedRed slow blinkOff Tamper + Low BatteryRed/Yellow Fast blinkOnce every 10 seconds Tamper + Low Battery Silenced Red/Yellow slow blinkOff CB34U Gateway Quick Start Guide 6) Device Specifications 5) Replacing the Battery If the battery is damaged or unable to charge properly, a trouble condition will appear via the Status LED turning Red. First, ensure that the battery is properly connected and AC Power has remained ON for at least 48 hours. If the trouble condition still exists, the battery may need to be replaced. To replace the battery, remove the rear cover to expose the battery, then replace with a RT645 SLA battery. Note the correct orientation of the battery and polarity of the wires. FCC Compliance Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ⁃ Reorient or relocate the receiving antenna. ⁃ Increase the separation between the equipment and receiver. ⁃ Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ⁃ Consult the dealer or an experienced radio/TV technician for help. Unauthorized modification of the Radio is prohibited; user that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Troubleshooting Scenarios Recommended Next Steps Power LED = Blinking Yellow or Red Confirm that the power cable is plugged in Confirm that the breaker/switch for the outlet is on 4G LTE LED = Solid or Blinking Red Try re-locating the CB34U to another suitable location with better LTE …

Text truncated - open the document above for the full version.

ID Label/Location Info

1 | P a g e Label - Location and Packaging.docx PRODUCT LABEL LABEL CONTENT Item Description Format A Customer Logo B Model # Calibri; Size 7; Bold C IMEI – 2D Barcode Code 128-B D IMEI – Human Readable Calibri; Size 7 E MAC Address – 2D Barcode Code 128-B F MAC Address – Human Readable Calibri; Size 7 G CB34 FCC ID: Number Calibri; Size 6 Icon; Calibri; Size 7 H SARA FCC ID: Number Calibri; Size 6 Icon; Calibri; Size 7 I “RESIDENTIAL FIRE ALARM AND SECURITY EQUIPMENT CONFORMS TO UL STDS 985/1023” Calibri; Size 5 J Power “INPUT: 120V AC 60Hz” Calibri; Size 6, BOLD K Factory of Origin “Made in Taiwan” Calibri; Size 6 L ETL Logo and ID Number ICON M BC Logo ICON N 3D Barcode (IMEI, MAC #) QR Code O Date Code YY/WW MODEL: IMEI: Made in Taiwan INPUT: 120V AC 60Hz 3W 20/01 CB34U-V-CEL01A O 01234567890123 MAC: 0123456789 FCC ID: 2AUQ4-CB34U A B C D G J K N L M RESIDENTIAL FIRE ALARM AND SECURITY EQUIPMENT. CONFORMS TO UL STDS 985/1023 1234567 I Contains FCC ID: XPY2AGQN4NNN H E F 2 | P a g e Label - Location and Packaging.docx 3 | P a g e Label - Location and Packaging.docx INDIVDUAL CARTON LABEL After packaging & sealing the box, it will be labeled on the side. The Carton Labels will include model number, and unique product identifiers (ie. IMSI & Serial #). Target size 75mm x 50mm Item Description Format A Cellbounce Logo B Date Code (YY/WW) Calibri; Size 9; Bold C Model: Calibri; Size 12; Bold D IMEI – 2D Barcode Code 128-B E IMEI – Human Readable Calibri; Size 11 F MAC Address – 2D Barcode Code 128-B G MAC Address – Human Readable Calibri; Size 11 H Lead Free Logo Icon I 3D Barcode (IMEI, MAC #) QR Code: 14 X 14 mm MODEL: IMEI: 01234567890123 Made in Taiwan 20/01 CB34U-01A A B C D E I H J MAC: 01234567890123 F G 4 | P a g e Label - Location and Packaging.docx J Factory of Origin “Made in Taiwan” Calibri; Size 7.5 MASTER PACK PACKAGING The packaged CB34U Gateways will be packed into a Master Pack box (in quantities of 6). 5 | P a g e Label - Location and Packaging.docx MASTER PACK LABEL (CARTON LABEL) The Master Pack Labels will show the IMEI Numbers of all devices inside the box. (Size 100mm x 120mm) Item Description Format A Cellbounce Logo B Date Code (YY/WW) Calibri; Size 12 C Model: Calibri; Size 8; Bold D IMEI – 2D Barcode Code 128-B E IMEI – Human Readable Calibri; Size 10 F Lead Free Logo Icon G Factory of Origin “Made in Taiwan” Calibri; Size 10 H 3D Barcode (all IMEIs of devices inside the box) QR Code Made in Taiwan MODEL: CB34U-01A A B C D E H IMEI: 01234567890123 F IMEI: 01234567890123 G IMEI: 01234567890123 IMEI: 01234567890123 20/01 IMEI: 01234567890123 CellBounce Inc. 2055 Corte Del Nogal Carlsbad, CA 92011 https://cellbounce.com C/N: EFAAEE1103357-01-01#CN0001 QUANTITY: 6 IMEI: 01234567890123 6 | P a g e Label - Location and Packaging.docx PALLETIZATION PALLET LOADING The Master Pack boxes will be stacked on Pallets and shrink wrapped for shipping. (6 Boxes per Carton; 14 Cartons per Layer; 3 Layers per Pallet = 42 Cartons = 252 Boxes) 7 | P a g e Label - Location and Packaging.docx PALLETS LABELS Item Description Format A RECEIVER’s Name and Address (as defined by PO) Calibri; Size 12 B SHIPPER’s Name and Address Calibri; Size 12 C Purchase Order # – Human Readable Calibri; Size 10 D Purchase Order # – 2D Barcode Code 128-B E Pallet ID # – Human Readable Calibri; Size 10 F Pallet ID # – 2D Barcode Code 128-B G Pallet Number and Total number of pallets in shipment Calibri; Size 10 H SKU Number of the CB34 (From PO and SKU Matrix) Calibri; Size 10 I SKU Description (From SKU Matrix) Calibri; Size 10 J Weight of Pallet Calibri; Size 10 K Number of Cartons on Pallet – Human Readable Calibri; Size 10 L Number of Cartons on Pallet – 2D Barcode Code 128-B M Date of Shipment Calibri; Size 10 A B C D E F G H I J K L M

RF Exposure Info

Intertek 731 Enterprise Drive Lexington, KY 40510 Tel 859 226 1000 Fax 859 226 1040 www.intertek.com Cell Bounce MPE REPORT SCOPE OF WORK MPE CALCULATION ON THE CB34U REPORT NUMBER 104295343LEX-004 ISSUE DATE 4/27/2020 PAGES 14 DOCUMENT CONTROL NUMBER Non-Specific EMC Report Shell Rev. December 2017 © 2017 INTERTEK This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Testing Services NA, Inc. MPE TEST REPORT Report Number: 104295343LEX-004 Project Number: G104295343 Report Issue Date: 4/27/2020 Product Name: CB34U Standards: FCC Part 1.1310 Limits for Maximum Permissible Exposure (MPE) RSS-102 Issue 5 RF Field Strength Limits for Devices Used by the General Public Tested by: Client: Intertek Testing Services NA, Inc. 731 Enterprise Drive Lexington, KY 40510 USA Cell Bounce 2055 Corte Del Nogal Carlsbad, CA 92011 USA Report prepared by Report reviewed by Brandon Norris, Engineer Bryan Taylor, Team Leader Evaluation For: Cell Bounce Product: CB34U EMC Test Report Date: 4/27/2020 Non-Specific EMC Report Shell Rev. December 2017 Page 3 of 14 Report Number: 104295343LEX-004 Table of Contents 1 Introduction and Conclusion ..................................................................................................................... 4 2 Test Summary .......................................................................................................................................... 4 3 Client Information .................................................................................................................................... 5 4 Description of Equipment under Test and Variant Models .......................................................................... 6 5 Antenna Gains: ........................................................................................................................................ 8 6 Output Power: ......................................................................................................................................... 9 7 FCC Limits .............................................................................................................................................. 10 8 RSS-102 Issue 5 Exposure Limits: ............................................................................................................. 11 9 Test Procedure ....................................................................................................................................... 12 10 Results: .............................................................................................................................................. 13 11 Revision History ................................................................................................................................. 14 Evaluation For: Cell Bounce Product: CB34U EMC Test Report Date: 4/27/2020 Non-Specific EMC Report Shell Rev. December 2017 Page 4 of 14 Report Number: 104295343LEX-004 1 Introduction and Conclusion The tests indicated in section 2.0 were performed on the product constructed as described in section 4.0. The remaining test sections are the verbatim text from the actual data sheets used during the investigation. These test sections include the test name, the specified test Method, a list of the actual Test Equipment Used, documentation Photos, Results and raw Data. No additions, deviations, or exclusions have been made from the standard(s) unless specifically noted. Based on the results of our investigation, we have concluded the product tested complies with the requirements of the standard(s) indicated. The results obtained in this test report pertain only to the item(s) tested. Intertek does not make any claims of compliance for samples or variants which were not tested. 2 Test Summary Section Test full name Result 10 FCC Part 1.1310 Limits for Maximum Permissible Exposure (MPE) (Limits for General Population / Uncontrolled Exposure) Pass RSS-102 Issue 5 RF Field Strength Limits (For Devices Used by the General Public) Pass Evaluation For: Cell Bounce Product: CB34U, Model CellBounce Gateway/CB34U MPE Report Date: 4/27/2020 Non-Specific EMC Report Shell Rev. December 2017 Page 5 of 14 Report Number: 104295343LEX-004 3 Client Information This product was tested at the request of the following: Client Information Client Name: Cell Bounce Address: 2055 Corte Del Nogal Carlsbad, CA 92011 USA Contact: Gary Hu Telephone: +1 469 939 7899 Email: [email protected] Manufacturer Information Manufacturer Name: Cell Bounce Manufacturer Address: 2055 Corte Del Nogal Carlsbad, CA 92011 USA Evaluation For: Cell Bounce Product: CB34U, Model CellBounce Gateway/CB34U MPE Report Date: 4/27/2020 Non-Specific EMC Report Shell Rev. December 2017 Page 6 of 14 Report Number: 104295343LEX-004 4 Description of Equipment under Test and Variant Models Equipment Under Test Product Name CB34U Model Number CellBounce Gateway/CB34U Hardware Version CB34UHW01 Software Version CB34UR01S Supported Transmit Bands LTE Bands: 2, 4, 12 (uplink) 3G (UMTS) Bands: 2, 5 (downlink) Embedded Module SARA-R410M Module HW Version 306A06 Module SW Version L0.0.00.00.06.…

Text truncated - open the document above for the full version.

Test Report

Intertek 731 Enterprise Drive Lexington, KY 40510 Tel 859 226 1000 Fax 859 226 1040 www.intertek.com Cell Bounce TEST REPORT SCOPE OF WORK EMC TESTING –CB34U REPORT NUMBER 104295343LEX-001 ISSUE DATE 4/27/2020 PAGES 72 DOCUMENT CONTROL NUMBER Non-Specific EMC Report Shell Rev. December 2017 © 2017 INTERTEK This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Testing Services NA, Inc. EMC TEST REPORT (FULL COMPLIANCE) Report Number: 104295343LEX-001 Project Number: G104295343 Report Issue Date: 4/27/2020 Product Tested: CB34U Standards: FCC Part 22, 24 RSS-132 Issue 3, RSS-133 Issue 6 Tested by: Client: Intertek Testing Services NA, Inc. 731 Enterprise Dr. Lexington, KY 40510 USA Cell Bounce 2055 Corte Del Nogal Carlsbad, CA 92011 USA Report prepared by Report reviewed by Brandon Norris, Engineer Bryan Taylor, Team Leader This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Testing Services NA, Inc. 1 Introduction and Conclusion ..................................................................................................................... 4 2 Test Summary .......................................................................................................................................... 4 3 Client Information .................................................................................................................................... 5 4 Description of Equipment under Test and Variant Models .......................................................................... 6 5 System Setup and Method ........................................................................................................................ 8 6 Output Power ........................................................................................................................................ 10 7 Occupied Bandwidth .............................................................................................................................. 17 8 Conducted Spurious Emissions and Band Edge at Antenna Terminals ....................................................... 37 9 Radiated Output Power .......................................................................................................................... 49 10 Radiated Spurious Emissions (Transmitter) .......................................................................................... 52 11 Frequency Stability ............................................................................................................................. 69 12 Measurement Uncertainty .................................................................................................................. 71 13 Revision History ................................................................................................................................. 72 Evaluation For: Cell Bounce Product: CB34U EMC Test Report Date: 4/27/2020 Non-Specific EMC Report Shell Rev. December 2017 Page 4 of 72 Report Number: 104295343LEX-001 1 Introduction and Conclusion The tests indicated in section 2.0 were performed on the product constructed as described in section 4.0. The remaining test sections are the verbatim text from the actual data sheets used during the investigation. These test sections include the test name, the specified test Method, a list of the actual Test Equipment Used, documentation Photos, Results and raw Data. No additions, deviations, or exclusions have been made from the standard(s) unless specifically noted. Based on the results of our investigation, we have concluded the product tested complies with the requirements of the standard(s) indicated. The results obtained in this test report pertain only to the item(s) tested. Intertek does not make any claims of compliance for samples or variants which were not tested. 2 Test Summary Page Test Name Result 10 Output Power Compliant 17 Occupied Bandwidth Compliant 37 Conducted Spurious Emissions and Band Edge at Antenna Terminals Compliant 49 Radiated Output Power Compliant 52 Radiated Spurious Emissions (Transmitter) Compliant 69 Frequency Stability Compliant Evaluation For: Cell Bounce Product: CB34U EMC Test Report Date: 4/27/2020 Non-Specific EMC Report Shell Rev. December 2017 Page 5 of 72 Report Number: 104295343LEX-001 3 Client Information Th…

Text truncated - open the document above for the full version.

Test Setup Photos

Frequency Stability to temperature changes Conducted Emissions: Conducted Measurements: Radiated Emissions Bilog: Radiated Spurious Emissions (Horn):

Contact Information

Applicant

Stephen J Ambrose(Technical Account Manager)
[email protected]4422249238Fax: 00000

Technical Contact

CellBounceTim Thome
[email protected]619-787-0058

2055 Corte Del Nogal · Carlsbad, California · United States

Non-Technical Contact

CellBounceDave Carey
[email protected]858-243-9802

Test Firm

Intertek Testing Services NAJames Sudduth
[email protected]859-226-1037Fax: 859 226 1040

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
222871.4 MHz - 891.6 MHz560.00 µW4M19F9W2.5 ppm
Confidentiality
Long Term
Grant Notes
Output Power listed is EIRP (Band 2) or ERP (Band 5). This device is a mobile device with respect to RF exposure compliance. This device contains a certified transmitter module, FCC ID: XPY2AGQN4NNN.