Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Page 1 of 21 DOC No. 0095771 User’s Manual CC1W-30/50klb User Manual - CC1W Page 2 of 21 DOC No. 0095771 Table of Contents 1. Product description ........................................................................................... 3 2. Mounting instructions ....................................................................................... 4 2.1 Base Unit .............................................................................................................................................. 4 2.2 Antenna Recommendations ................................................................................................................. 6 2.3 Remote Unit (Wireless Loadcell) .......................................................................................................... 9 2.4 Battery Installation ...............................................................................................................................10 3. Equipment Maintenance ................................................................................. 11 3.1 Battery Replacement ...........................................................................................................................11 4. Operation .......................................................................................................... 12 4.1 Base unit wireless channel selection (if needed) ........................................................................................13 5. Technical Specification ................................................................................... 14 6. Product Label ................................................................................................... 15 7. Product Dimensions ........................................................................................ 16 8. Safety information ........................................................................................... 18 User Manual - CC1W Page 3 of 21 DOC No. 0095771 1. Product description The CC1W is a wireless version of our CC1 pump off control load cell. The CC1W utilizes the same proven design attributes as the CC1 - stainless steel, hermetic seal, fatigue rating and intrinsically safe operation. The CC1W transmits polished rod load wirelessly which solves the industry wide problem of cable failures. After months of development in the field, working hand in hand with end users, our design addresses the most demanding concerns raised. The CC1W technology sets our product apart from all wireless products currently available in the market. The primary advantage we bring is extremely low power consumption. Despite the low power consumption, the product can deliver a continuous flow of data, high signal strength and long battery life. We also offer position sensing capability which is synchronized with the load measurement. This eliminates the need for hall effect sensors or inclinometers and the costly maintenance associated with each. The wireless enclosure also incorporates an independent compartment for both the wireless technology and the battery. This allows for easy, single handed access to the battery for replacement in the field. We carefully specified a pre-wired “D cell” battery that is inexpensive and commercially available worldwide. • Continuous flow of data: 100 readings per second • Low power consumption: 12-18 month battery life • High signal strength: +13dBm to +17dBm, 30-300 meter transmission • HazLoc approved: UL rated for Class 1, Division 1 environments (see label for full approval) • On-board position: +/-0.5% accuracy • Security: Proprietary wireless transmission protocol • Ease of use: independent battery access, commercially available battery • Weatherproof: IP67 rating, rated for use in -70°F to 175°F (-55°C to 80°C) Accessories: Base/Receiver (included) Antenna & Connection Cables (included) Lithium Battery (Included) Magnetic Mount or Post Mount for Base (user specified) Load Spacer/Plate Spherical Washer Set User Manual - CC1W Page 4 of 21 DOC No. 0095771 2. Mounting instructions IMPORTANT The employees responsible for the equipment installation and verification must take into consideration all the actions concerning this subject specified in IEC 60079-14:2013 ed. 5.0 (Electrical installations design, selection and erection) standard. In addition to general specifications associated with any system installed in hazardous locations, special attention should be paid for specific requirements regarding intrinsic safety (section 12). 2.1 Base Unit The “Base” (receiver) of the device comes with a magnet base for easy mounting on a metal surface inside or outside of the pump controller cabinet. Base is mounting outside the hazardous area and not intended to meet hazardous location safety standards. Base Unit User Manual - CC1W Page 5 of 21 DOC No. 0095771 When the magnet base is not directly attached due to non-metallic surface or space constraint, the base can be suitable fastened to any structure using brackets, plates or other type of support. _________________________________________________________________ IMPORTANT In order to achieve the best performance a vertical alignment of the antenna must be ensured. You may optionally use an extension cable to mount the antenna. DIN rail mount Pole mount with U- User Manual - CC1W Page 6 of 21 DOC No. 0095771 2.2 Antenna Recommendations Omni Directional Antenna CC1W base unit is equipped with an Omni- directional antenna in order to provide the widest possible signal coverage. RP-SMA Connector (female) The antenna is provided with a threaded, weatherproof RP-SMA female connector. This connector must be properly tightened to the male connector on the enclosure. Vertical Alignment In order to achieve the best performance a vertical alignment of the antenna must be ensured. Line-of -sight Is important to find, whenever possible, a spot full line of sight with the receptor where no obstacles reside between the path.…
Text truncated - open the document above for the full version.
Process CC1W/CCWR - Hazardous Marking Label Locations for Base Document 0096572 Drawn By JCS Checked By Drawn Date 11 Feb 20 Page 1 of 1 Revision Revised By JCS Checked By Issued Date Label Drawing – 0095717 (Use latest version) Label readable from front face
5945 Cabot Parkway Suite 100 Alpharetta, GA 30005 USA Certification Exhibit FCC ID: 2AUSA-CC1WRB FCC Rule Part: 47 CFR Part 2.1093 Project Number: 72153197 Manufacturer: Flintec, Inc. Model: CC1WRB RF Exposure Model(s): CC1WRBFCC ID: 2AUSA-CC1WRB Report: AT72153197-2C0Page 2 General Information: Applicant: Flintec Inc Device Category: Mobile Environment: General Population/Uncontrolled Exposure Technical Information: Antenna Types: ½ Wave Dipole Antenna / 3.2dBi (Linx, P/N: ANT-2.4-CW-HW) ½ Wave Dipole Antenna / 3.2dBi (Linx, P/N: ANT-2.4-CW-HWR-ccc) ¼ Wave Dipole Antenna / -0.2dBi (Linx, P/N: ANT-2.4-CW-RCS-xxx) Antenna Gain: 3.2dBi (Max) Maximum Transmitter Conducted Power: 17.1dBm, 51.29mW Maximum System EIRP: 20.3dBm, 107.15mW Exposure Conditions: Greater than 20 centimeters MPE Calculation The Power Density (mW/cm 2 ) is calculated as follows: S = 2 4R PG Where: S = power density (in appropriate units, e.g. mW/cm2) P = power input to the antenna (in appropriate units, e.g., mW) G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna (appropriate units, e.g., cm) Table 1: MPE Calculation Transmit Frequency (MHz) Radio Power (dBm) Power Density Limit (mW/cm 2 ) Radio Power (mW) Antenna Gain (dBi) Antenna Gain (mW eq.) Distance (cm) Power Density (mW/cm 2 ) 2405 17.1 1.00 51.29 3.2 2.089 20 0.021
5945 Cabot Pkwy, Suite 100, Alpharetta, GA 30005 Test Report FCC ID: 2AUSA-CC1WRB IC: 25535-CC1WRB FCC Rule Part: 15.247 ISED Canada Radio Standards Specification: RSS-247 Report Number: AT72153197-1C1 Manufacturer: Flintec, Inc. Model/HVIN: CC1WRB Test Begin Date: January 6, 2020 Test End Date: January 20, 2020 Report Issue Date: February 18, 2020 FOR THE SCOPE OF ACCREDITATION UNDER Certificate Number: 2955.09 This report must not be used by the client to claim product certification, approval, or endorsement by A2LA, NIST, or any agency of the Federal Government. Prepared By:Reviewed by: Jeremy PickensRyan McGann Senior Wireless EngineerTeam Leader TÜV SÜD America Inc.TÜV SÜD America Inc. This test report shall not be reproduced except in full. This report may be reproduced in part with prior written consent of TÜV SÜD America Inc. The results contained in this report are representative of the sample(s) submitted for evaluation. This report contains 31 pages 5945 Cabot Pkwy, Suite 100, Alpharetta, GA 30005 TABLE OF CONTENTS 1GENERAL ...................................................................................................................................... 3 1.1PURPOSE ....................................................................................................................................... 3 1.2APPLICANT INFORMATION ............................................................................................................ 3 1.3PRODUCT DESCRIPTION ................................................................................................................ 3 1.4TEST METHODOLOGY AND CONSIDERATIONS ............................................................................... 4 2TEST FACILITIES ....................................................................................................................... 5 2.1LOCATION ..................................................................................................................................... 5 2.2LABORATORY ACCREDITATIONS/RECOGNITIONS/CERTIFICATIONS .............................................. 5 2.3RADIATED EMISSIONS TEST SITE DESCRIPTION ............................................................................ 6 2.3.1Semi-Anechoic Chamber Test Site – Chamber A ..................................................................... 6 2.3.2Semi-Anechoic Chamber Test Site – Chamber B ..................................................................... 7 2.4CONDUCTED EMISSIONS TEST SITE DESCRIPTION ......................................................................... 8 2.4.1Conducted Emissions Test Site ................................................................................................. 8 3APPLICABLE STANDARD REFERENCES ............................................................................. 9 4LIST OF TEST EQUIPMENT ..................................................................................................... 9 5SUPPORT EQUIPMENT.............................................................................................................10 6EQUIPMENT UNDER TEST SETUP BLOCK DIAGRAM ....................................................10 7SUMMARY OF TESTS................................................................................................................11 7.1ANTENNA REQUIREMENT –FCC15.203 ......................................................................................11 7.2POWER LINE CONDUCTED EMISSIONS –FCC15.207,ISEDCANADA:RSS-GEN 8.8 ..................11 7.2.1Measurement Procedure .........................................................................................................11 7.2.2Measurement Results ..............................................................................................................11 7.36DB/99%BANDWIDTH –FCC15.247(A)(2),ISEDCANADA:RSS-2475.2(A),RSS-GEN6.7 ..12 7.3.1Measurement Procedure .........................................................................................................12 7.3.2Measurement Results ..............................................................................................................12 7.4FUNDAMENTAL EMISSION OUTPUT POWER –FCC15.247(B)(3),ISEDCANADA:RSS-2475.4(D) .....................................................................................................................................................15 7.4.1Measurement Procedure .........................................................................................................15 7.4.2Measurement Results ..............................................................................................................15 7.5EMISSION LEVELS ........................................................................................................................16 7.5.1Emissions into Non-restricted Frequency Bands – FCC 15.247(d); ISED Canada: RSS-247 5.5 ............................................................................................................................................16 7.5.2Emissions into Restricted Frequency Bands – FCC: 15.205, 15.209; ISED Canada: RSS-Gen 8.9 / 8.10..................................................................................................................................18 7.6MAXIMUM POWER SPECTRAL DENSITY IN THE FUNDAMENTAL EMISSION –FCC15.247(E)ISED CANADA:RSS-2475.2(B) ............................................................................................................21 7.6.1Measurement Procedure .........................................................................................................21 7.6.2Measurement Results ..............................................................................................................21 8ESTIMATION OF MEASUREMENT UNCERTAINTY .........................................................23 9CONCLUSION ...........................................................................................................…
Text truncated - open the document above for the full version.
5945 Cabot Parkway Suite 100 Alpharetta, GA 30005 USA Certification Exhibit FCC ID: 2AUSA-CC1WRB IC: 25535-CC1WRB FCC Rule Part: 15.247 ISED Canada Radio Standards Specification: RSS-247 Project Number: 72153197 Manufacturer: Flintec, Inc. Model/HVIN: CC1WRB Test Setup Photos Model(s): CC1WRBFCC ID: 2AUSA-CC1WRBIC: 25535-CC1WRB Project: 72153197Page 2 Figure 1: Equipment Under Test – Antenna Port Conducted Measurements Figure 2: Equipment Under Test – Radiated Emissions <30MHz Model(s): CC1WRBFCC ID: 2AUSA-CC1WRBIC: 25535-CC1WRB Project: 72153197Page 3 Figure 3: Equipment Under Test – Radiated Emissions <30MHz Figure 4: Equipment Under Test – Radiated Emissions <1GHz Model(s): CC1WRBFCC ID: 2AUSA-CC1WRBIC: 25535-CC1WRB Project: 72153197Page 4 Figure 5: Equipment Under Test – Radiated Emissions <1GHz Figure 6: Equipment Under Test – Radiated Emissions >1GHz Model(s): CC1WRBFCC ID: 2AUSA-CC1WRBIC: 25535-CC1WRB Project: 72153197Page 5 Figure 7: Equipment Under Test – Radiated Emissions >1GHz
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.47 GHz | 51.00 mW |
Wireless Load Cell Remote Unit
Equipment Class
DTS - Digital Transmission System