Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Form: RFT-AMER-TCB-OP-19m Revision: 1 Page 1 of 1 Date: 12/08/2022 [Enclave Audio Limited] Attention: Application Examiner Re: Covered List, located at https://www.fcc.gov/supplychain/coveredlist and Report & Order 22-84 located at https://docs.fcc.gov/public/attachments/DOC-389524A1.pdf Applicant: Enclave Audio Limited FCC ID: 2AUTT-EA150SB, 2AUTT-EA150SBSW To whom it may concern, Pursuant to FCC Report & Order 22-84 section IV. Interim Freeze Order, paragraphs 264, 265, and 266, as an authorized representative of [Enclave Audio Limited], I attest that the equipment for which we are seeking equipment authorization through certification is not prohibited from receiving an equipment authorization; and [ Enclave Audio Limited] is not an entity identified on the Covered List or an affiliate or subsidiary of an entity identified on the Covered List, established pursuant to 47 CFR §1.50002. I HEREBY CERTIFY THAT I am authorized to make the representations above on behalf of the company and agree to immediately notify Intertek if there is any change in the status identified above. [Signature of authorized Proprietor, Partner or Authorized Officer] [Title] [Company name] CTO ENCLAVE AUDIO LTD.
11 22 33 44 55 66 77 88 D D C C B B A A R e m a r k : T h i s r e l e a s e d d r a w i n g w a s p r o d u c e d b y c o m p u t e r . D o n o t u p d a t e b y h a n d w o r k . Model No: DATE Modify summary Drawn by Approved by Ver JH.X 产 品 要 求 REQUIRED 所有材料符合 RoHS 和 REACH 法规指令,有害物质符合采购合同的 HSF 要求 IT66322 MCU &repeater HDMI OUT HDMI Switch HDMI IN1HDMI IN2 TAS5825AmplifierTAS5825AmplifierTAS5825AmplifierTAS5825Amplifier Bluetooth LED C08529EYSLED driver 1 2 3 4 5 6 REM 1 GND 2 Vcc 3 ...... Audio DSP SPA300 DC/DC FLASH FL & FRSL & SRTOPL & TOPRCENT Amplifier Wireless Subwoofer Switch7227 x 2 123 Wireless TX 8811 TAS5825Amplifier TOPL & TOPRTreBass TM1640 Y127MHz YM 1 24MHz TDA7498E HDMI_ARC HDMI_I2S OPTICAL_S/PDIFCOAXIAL_S/PDIFANALOG I2S_D0I2S_D1I2S_D2I2S_D3 USB IRAUX COAXIAL OPTICAL DAC ES7144 I2S Analog PSU VCC VCC1 PSU SoundBar Main SET 2021.12.07 0.1 JZ1 24.57MHz Processor Y1 24MHz BAND tx/rx Wireless RX 8819 Processor Y1 24MHz BAND tx/rx MCU_I2S
Enclave Audio Limited 22 Nov 2022 Federal Communications Commission 445 12 th Street SW Washington, DC 20554 Subject: Limited Agency Agreement Enclave Audio Limited FCC ID: 2AUTT-EA150SB and FCC ID: 2AUTT-EA150SBSW To Whom It May Concern: We, Enclave Audio Limited, hereby authorized Intertek Testing Services to act as our Agent for the purpose of preparing application for FCC ID number : 2AUTT-EA150SB and : 2AUTT- EA150SBSW under all applicable parts of the FCC rules and regulations. The effective date of this limited agency agreement is 22 Nov 2022. The Limited Agency Agreement expires on 22 Nov 2023 unless sooner terminated or extended by written notice to Intertek Testing Services and the Federal Communications Commission. This is to advise that we are in full compliance with the Anti-Drug Abuse Act. The applicant is not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 U.S.C. 862, and no party to the application is subject to a denial of federal benefits pursuant to that section. If you have any questions or comments, please do not hesitate to contact me. Sincerely, Rob Jones Chief Technology Office
TEST REPORT TEST REPORT
Label & Label Location 70x30mm
TEST REPORT TEST REPORT TEST REPORT TEST REPORT 2.4GHz antenna
Technical Description The equipment under test (EUT) is a WIRELESS SUBWOOFER with SRD 2.4GHz function operating in 2402-2480MHz. The EUT is powered by AC 100-240V~ 50/60Hz. For more detail information pls. refer to the user manual. 2.4GHz transmitter: Antenna Type: Integral Antenna. Antenna Gain: 0.19 dBi. Modulation Type: GFSK. The nominal conducted output power specified: 7(+/-2dB) The nominal radiated output power (e.i.r.p) specified: 7.19(+/-2dB) SRD 2.4GHz Channel List 2402 2403 2404 2405 2406 2407 2408 2409 2410 2411 2412 2413 2414 2415 2416 2417 2418 2419 2420 2421 2422 2423 2424 2425 2426 2427 2428 2429 2430 2431 2432 2433 2434 2435 2436 2437 2438 2439 2440 2441 2442 2443 2444 2445 2446 2447 2448 2449 2450 2451 2452 2453 2454 2455 2456 2457 2458 2459 2460 2461 2462 2463 2464 2465 2466 2467 2468 2469 2470 2471 2472 2473 2474 2475 2476 2477 2478 2479 2480 The function of main component is mentioned as below. 1) U5(TDA7498E) is a digital audio amplifier chip 2) M2 is a 2.4GHz module In the 2.4GHz wireless module. 1) U1(TLSR9515H) acts as 2.4G Wireless RF chip. 2) Y1 is a 24MHz oscillator for U1(TLSR9515H).
INTERTEK TESTING SERVICES RF Exposure The equipment under test (EUT) is a WIRELESS SUBWOOFER with SRD 2.4GHz function operating in 2402-2480MHz. The EUT is powered by AC 100-240V~ 50/60Hz. For more detail information pls. refer to the user manual. Standalone SAR evaluation for 2.4GHz transmitter 2.4GHz transmitter: Antenna Type: Integral Antenna. Antenna Gain: 0.19 dBi. Modulation Type: GFSK. The nominal conducted output power specified: 7dBm (+/-2dB). The nominal radiated output power (e.i.r.p) specified: 7.19dBm (+/- 2dB). The maximum conducted output power for the EUT is 8.79dBm in the frequency 2480MHz which is within the production variation. The minimum conducted output power for the EUT is 7.21dBm in the frequency 2402MHz which is within the production variation. According to FCC Part 2.1091, this unlicensed transmitting devices is categorically excluded from routine environmental evaluation for RF exposure prior to equipment authorization or use, According to the KDB 447498 and OET 65, the simple calculation as below: The source-based time averaged maximum radiated power = 7.19dBm+2dB = 9.19dBm = 8.30mW From above data, the exposed power density at a distance (R) of 20cm from the center of radiation of the antenna for 2.4GHz band can be calculated according to OET 65 as follow: = 8.30mW/ 4πR^2 = 0.00165 mW/cm^2 <1mW/cm^2 The MPE limit is 1.0 mW/cm^2 for general population and uncontrolled exposure in the 2.4GHz frequency range according to FCC Part 1.1310. As the measured power density at 20cm from the transmitter is lower than the MPE limit, the compliance to the MPE limit can be ensured by indicating the minimum 20cm separation between the transmitter's radiating structure and body of the user or nearby persons. FCC ID: 2AUTT-EA150SBSW
11 22 33 44 55 66 77 88 D D C C B B A A R e m a r k : T h i s r e l e a s e d d r a w i n g w a s p r o d u c e d b y c o m p u t e r . D o n o t u p d a t e b y h a n d w o r k . C2102/1KV R7 100 FU1 T5AL250V L HVDD R1825/2W 35V EC5680UF/50V EC7 680UF/50V VR1 10D821 R22 1.5M R27 1.5M 12 EC1120uF/450v18*32 L BD1GBU810 C9103/1KV CX1 0.47UF/275V 12 CON1 DB-8-16P20 12 34 LF2 UU1620MH R8 100 R26 1.5M R28 1.5M R201.2M C5222/1KV 1 1 2 2 D12IN5408 12 CON23.96/2PIN 12 34 LF3 T12.7*7.9*6.30.8mm R191.2M N NTC15D13 R15 0R EC4 22u/50vD7 1N4148 D8M7 C8104 SD G Q1 HCS65R210S R111K C447P/1KV Q2MMBT3906 R12330 R310K R100 R651K* R161K R22.2K R144.7 R25 NC R29 NC C3220P R170.12/3W R1 2.2K U2 EL1018 C6104 R41K A 3 K 2 R 1 U3 TL431 R9 43K R13 4.3K C7472 CY1 1000PF CY2 470PF M o d e l N o : RPW709BREV0.2 Cannot open file D:\My design\RSR\logo 常用形式 -5.png M o d i f y s u m m a r y D A T E Ver A p p r o v e d b y D r a w n b y D K . C N A J H . X 2020-07-3 V0.1 Cannot open file D:\My design\RSR\ 机密文件 .jpg VDD C10 2.2uF FB 2 NTC 3 GND 1 GATE 6 CS 4 VCC 5 U1 KP201A EC6680UF/50V D1 20L300CTF R24 100 1 1 2 2 HS1 散热器(同RPW704) 1 1 2 2 HS2 散热器(同RPW1100) D61N4148 R5 2.0 R21 68K/2W 12 34 LF1 T9*5*39T0.6mm400UH R30NC 12 EC2120uF/450v18*32 10 4 9 126 118 5 T1PQ3225 ZD120V 7 闪电 6 闪电 1 闪电 4 闪电 5 闪电 8 闪电 9 闪电 3 闪电 2 闪电 10 闪电 24 闪电 ! 14 ! 16 ! 15 ! 11 ! 12 ! 18 ! 20 ! 19 ! 17 ! 13 21 ! 25 ! 22 ZD220V C11NC C12NC NTC2254 NTC3NC R23NC LL B+ B+ J1 11 22 33 44 55 66 77 88 D D C C B B A A R e m a r k : T h i s r e l e a s e d d r a w i n g w a s p r o d u c e d b y c o m p u t e r . D o n o t u p d a t e b y h a n d w o r k . Model No: DATE Modify summary Drawn by Approved by Ver JH.X 产 品 要 求 REQUIRED 所有材料符合 RoHS 和 REACH 法规指令,有害物质符合采购合同的 HSF 要求 From PSU CE2 470u/10 CB8104 A3V3 I2S MCLKI2S BCLKI2S LRCLKI2S DOUT CB6104 L2 FB/33 SW1 TACT_3.5 R110K CB1104 LED KEY CB2104 To Wireless module R13 470 R14 470 R12 470 LED KEY STANDBY TXD RXD R111K I2S MCLK R15 470 I2S BCLKI2S LRCLKI2S DOUT C35104 C2 22u C15NCC16 1u CB3104 C3 1P C4 1P C5 1P A3V3 R160 A3V3 C6 10u C9 1P R1047K R17 1 MUTE SDATA 1 SCLK 2 LRCK 3 CLKIN 4 CAP1 5 CAP2 6 AOUTL 7 GND 8 VDD 9 AOUTR 10 U1ES7144LV / 7144S A3V3 A3V3 C19104 C1 10u 3V3 OUT_DAC R4 10K A3V3 V+ 1 out1 2 in1 3 int 4 verf 5 sence 6 sw 7 in2 8 out2 9 GND 10 U2NC R22 NC C14NC C11NC C12NC C17NC C13NC A3V3 AGC_OUT L5 NC C37 NC LED1 NC STANDBY MUTE_AMP 1 2 3 4 CN12.54/4P GNDVCCGND Q28050 Q1 8050 R210K R335K6 VCC /FAULT /FAULT VCC 1 HS1HEAT SINK STA510 SW-O R32220K MUTE R34NC A3V3 VDDS DIAG C45684 L4 27uH/6A C362.2u C25102 R28 200K CB5 104 C39NC C18 1u R308.2R R24 33K C32 10u CB111u/50 R21 750K R810K C27 102 C33 10u C28102 R29 0 C38681 C26102 C21104/50 C342.2u C23104/50 L727uH/6A C24104 C46224 CB9104 PSS036(SLUG_UP) SUB_GND 1 INPA 22 INNA 23 SGND 27 VDDS 26 DIAG 28 VDDPW 19 PGND 18 SYNCLK 25 ROSC 24 GAIN0 30 GAIN1 31 SVCC 35 OUTNB 8 PGNDB 4 PGNDB 5 PVCCB 6 PVCCB 7 OUTPB 3 OUTNA 11 OUTNA 10 PVCCA 13 PVCCA 12 PGNDA 14 OUTPA 17 OUTPA 16 PGNDA 15 VSS 36 INPB 32 INNB 33 MUTE 21 STBY 20 OUTPB 2 OUTNB 9 VREF 34 SVR 29 U5 TDA7498E CB7104 R2710 C47224 C201u CB121u/50 R2622 CB10104 R25 47K R318.2R C101u R1839K CE41000u/50 C8 1u C44684 VCC VDDS R2333K 12 CN22.54/2P SW+SW- R6 10K 1% R733K 1% VCC A3V3 CE3 470u/10 CB13104 Vo=VFB*(1+R2/R1) 0.7MHZ Imax=1Awhere VFB=0.765V R3NC VCC C43NC L8 L9 L147uH/1A D1 WSB5508L Q3 8050 R3710K R361K SW-O R351M R341NC A3V3 C494.7u CE5 470u/25V C484.7U C50 104 C51103 AGC_OUT STANDBY R9NC R39 100K OUT_DAC C52681 R3810 CB4104 L10 FB/DIP-40 L11FB/DIP-40 R19NC A3V3 R515K R2047K VCC C2910u R40 0 AGC_OUT OUT_DAC LED2 ORANGE C30224C31224 C7104 CE1 100u/50 L3 FB/31 2A CB 1 GND 2 FB 3 SHDN 4 Vin 5 SW 6 U3IC-LMR14010A C5410u C53104 GP5 2 GP4 3 P40 4 BLED 5 P24 6 P22 7 ADCBAT 12 TXD 13 RXD 14 GND 15 3V3 16 I2SMO 17 I2SMI 18 GND 1 PWM 8 GP8 9 I2SCLK 20 GP7 11 GP6 10 I2SLRCK 19 ISMCLK 21 ADC 22 SDA 23 SCL 24 M22.4G-RX 3V3 1234 CN44P GND GND STANDBY MUTE I2S MCLK I2S BCLK I2S LRCLK I2S DOUT KEY LED TXDRXD CE6100u/10 3V3 GND 1 3V3 2 SD2 3 SD1 4 LRCK 5 BCK 6 MCLK 7 KEY 8 SDA 9 SCL 10 LED 11 GND 12 TXD 13 RXD 14 M1NC/CSM5_5.8G 2020.04.29 V1.1 CB14NC/104 Saturday, August 14, 2021 A3 0.1 2 2 WB-8819R TELINK of Sheet Date: Rev Document Number SizeTitle ABCD 5 4 3 2 1 DCBA 1 2 3 4 5 C16104 C12 104 1 3 2 4 F1BPF2R45 TP2HOLE L1 1.5nH 56 PA[6] 1 PA[7] 2 PB[0] 3 PB[1] 4 PB[2] 5 PB[3] 6 PB[4] 7 PB[6] 8 AIPL1 9 AINL1 10 AINR1 11 AIPR1 12 MICBIAS1 13 VCAP 14 VSSA 15 VREFP_CODEC 16 AVD 17 AOPHPL 18 AONHPL 19 AONHPR 20 AOPHPR 22 PC[3] 23 VDDDEC 24 PC[4] 25 PC[5] 26 PC[6] 27 PC[7] 28 VBUS 29 VBAT 30 VDD3 31 VDD1V4_O 32 VDD1V4 33 FVDD1V8 34 VDD1V8_O 35 AVDD3 36 PD[0] 37 PD[1] 38 PD[2] 39 PD[3] 40 PD[4] 41 PD[5] 42 PD[6] 43 RESETB 44 GANT 45 ANT 46 VLINE_PAD 47 XC1 48 XC2 49 PE[0] 50 PE[2] 51 PE[3] 53 PE[7] 52 PE[6] 54 PA[0] 55 PA[5] 57 GND 21 PC[0] U1 TLSR9515H C21 33P C2NC C28 NC R4 22R R1 4.7K C3 104 C20 33P C25 106 C23 106 C7105 R2 4.7K C10 105 C27 106 3 41 2 Y1 24MHz-12pF-+/-20ppm C5 1.2P C15105 R6 22R TVS1 RST0521L C9 105 C26 106 C22 33P C1NC 1 GND 2 PA7/SWS 3 PB0 4 PB1 5 PD1/LED 6 PD2 7 PD3 8 PD0 9 PD4 10 PD5 11 PB2/TXD 12 PB3/RXD 13 PA5/DM 14 PA6/DP 15 GND 16 VBAT 17 PB6 18 PC5_DATA 19 PC4_LRCLK 20 PC3_BCK 21 PA0_MCLK 22 PB4 23 PE2/SDA 24 PE0/SCL M1WB-8819R L4 0R C24 106 R5 22R C14 105 ANT1 ANTENNA C11 NC 1 2 L2 10uH TP1HOLE C19 104 C8 105 C4 NC C17 105 C6 105 R3 22R C18 105 C13105 1 2 L3 10uH RFVDD1V4 VBAT VDD3_DCDC RFVDD1V4 VDD3_DCDC VDD1V8 VDD1V8 VDD3_DCDC VBAT PE2 PE2 PC5_DAC_DAT PA0_MCLK PA0_MCLK PB3 PB3 PC4_LRCLK PC4_LRCLK PB0 PB0 PB6 PB6 PE0 PE0 PD2 PD2 PB2 PB2 PC4_DAC_LR PD3 PD3 PD4 PD4 PD5 PD5PA7 PA7 PD1 PD1 PB4 PB4 PC3_BCK PC3_BCK PD0 PD0 PA6_DP PA6_DP PC3_I2S_BCK PC5_DAT PC5_DAT RST PA5_DM PA5_DM PB1 PB1 ANT NC
Enclave Audio Limited TEST REPORT SCOPE OF WORK FCC TESTING–EA-150-SB-SW REPORT NUMBER 221021038SZN-003 ISSUE DATE [REVISED DATE] 15 November 2022 [---------------------] PAGES 35 DOCUMENT CONTROL NUMBER FCC ID 247_b © 2017 INTERTEK Intertek Report No.: 221021038SZN-003 This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Testing Services Shenzhen Ltd. Longhua Branch 101, 201, Building B, No. 308 Wuhe Avenue, Zhangkengjing Community, GuanHu Subdistrict, LongHua District, Shenzhen, P.R. China. Tel: (86 755) 8601 6288 Fax: (86 755) 8601 6751 Version: 01-November-2017 Page: 1 of 35 FCC ID 247_b TEST REPORT 101, 201, Building B, No. 308 Wuhe Avenue, Zhangkengjing Community, GuanHu Subdistrict, LongHua District, Shenzhen, P.R. China. Tel: (86 755) 8601 6288 Fax: (86 755) 8601 6751 www.intertek.com Enclave Audio Limited Application For Certification FCC ID: 2AUTT-EA150SBSW WIRELESS SUBWOOFER Model: EA-150-SB-SW Brand name: ENCLAVE 2.4GHz Transceiver Report No.: 221021038SZN-003 We hereby certify that the sample of the above item is considered to comply with the requirements of FCC Part 15, Subpart C for Intentional Radiator, mention 47 CFR [10-1-21] Prepared and Checked by: Approved by: Mandy Chen Peter Kang Engineer Senior Technical Supervisor Date: 15 November 2022 Intertek Report No.: 221021038SZN-003 Version: 01-November-2017 Page: 2 of 35 FCC ID 247_b TEST REPORT MEASUREMENT/TECHNICAL REPORT This report concerns (check one) Original Grant X Class II Change Equipment Type: DTS - Part 15 Digital Transmission Systems Deferred grant requested per 47 CFR 0.457(d)(1)(ii)? Yes No X If yes, defer until: date Company Name agrees to notify the Commission by: date of the intended date of announcement of the product so that the grant can be issued on that date. Transition Rules Request per 15.37? Yes No X If no, assumed Part 15, Subpart C for intentional radiator - the new 47 CFR [10-01-21] Edition] provision. Report prepared by: Mandy Chen Intertek Testing Services Shenzhen Ltd. Longhua Branch 101, 201, Building B, No. 308 Wuhe Avenue, Zhangkengjing Community, GuanHu Subdistrict, LongHua District, Shenzhen, P.R. China. Tel: (86 755) 8601 6288 Fax: (86 755) 8601 6661 Intertek Report No.: 221021038SZN-003 Version: 01-November-2017 Page: 3 of 35 FCC ID 247_b TEST REPORT Table of Contents 1.0 Summary of Test results ............................................................................................... 4 2.0 General Description ...................................................................................................... 5 2.1 Product Description ........................................................................................................... 5 2.2 Related Submittal(s) Grants ............................................................................................... 5 2.3 Test Methodology .............................................................................................................. 5 2.4 Test Facility ........................................................................................................................ 5 3.0 System Test Configuration ............................................................................................ 6 3.1 Justification ........................................................................................................................ 6 3.2 EUT Exercising Software ..................................................................................................... 6 3.3 Special Accessories ............................................................................................................ 6 3.4 Measurement Uncertainty ................................................................................................. 7 3.5 Equipment Modification .................................................................................................... 7 3.6 Support Equipment List and Description .......................................................................... 7 4.0 Measurement Results ................................................................................................... 8 4.1 Maximum Conducted Output Power at Antenna Terminals ................................................. 8 4.2 Minimum 6 dB RF Bandwidth ............................................................................................ 9 4.3 Maximum Power Density Reading ................................................................................... 11 4.4 Out of Band Conducted Emissions ................................................................................... 13 4.5 Out of Band Radiated Emissions ...................................................................................... 20 4.6 Transmitter Radiated Emissions in Restricted Bands ........................................................ 21 4.7 Field Strength Calculation ................................................................................................ 22 4.8 Radiated Spurious Emission ............................................................................................. 23 4.9 Conducted …
Text truncated - open the document above for the full version.
WB8819 ANTENNA SPECIFICATION 1. Antenna Sise 2. Antenna test parameter Frequency(MHz) Efficiency (dBi) Gain (dBi) Efficiency (%) 2400 -5.06-0.8831.20 2410 -4.88-0.6732.50 2420 -4.84-0.6732.80 2430 -4.87-0.7932.59 2440 -4.67-0.6634.15 2450 -4.51-0.4335.41 2460 -4.46-0.1535.81 2470 -4.260.15 37.47 2480 -4.080.19 39.11 2490 -3.800.45 41.71 2500 -3.450.69 45.23 Shenzhen World Elite Electronic Co.,Ltd. Address: Room 101-3, Building 4, Xiangyuer Industrial Park, No. 8, Longsheng Road,Longgang Community, Longgang District, Shenzhen 3. Antenna 2D/3D drawing
Page 1 of 2 TEST REPORT Front View (Below 1GHz) Back View (Below 1GHz) The EUT is placed at the center of turntable Page 2 of 2 TEST REPORT Front View (Above 1GHz) Back View (Above 1GHz) The EUT is placed at the center of turntable
Page 1 of 1 TEST REPORT CONDUCTED EMISSION TEST SET-UP Front View Slide View
101, 201, Building B, No. 308 Wuhe Avenue, Zhangke · Shenzhen · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 7.51 mW |

ECLIPSE 5.1.2 SOUNDBAR + WIRELESS SUBWOOFER
Equipment Class