Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
KP2236S Wireless Charging Notebook Instruction Manual notebook notebook KP2236S 2A 1A 3 Phone charges immediately upon contact The distance between user and products should be no less than 20cm
DATE : 2019-12-06 Federal Communications Commission Authorization & Evaluation Division 7345 Oakland Mills Road Columbia, Maryland 21046 Authority to Act as Agent On our behalf, I appoint Jason Wu of Global United Technology Services Co., Ltd.and No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the Federal Communications Commission’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, still resides with NINGBO UNIVERSAL DRAGON I/E CORP. and 9/f Kirin Mansion,Tiantong North Road 1539#, Ningbo, China Signature: Name: Winni Wu Title: Sale Company: NINGBO UNIVERSAL DRAGON I/E CORP.
NINGBO UNIVERSAL DRAGON I/E CORP. DATE : 2019-12-06 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: 2AUVH-KP2236S Product Name: wireless charger notebook Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commissions rules, we hereby request that the following documents be held confidential: (List here the documents for which you are seeking confidentiality – for example ...) Schematics Block diagram Operation description These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. Signature: Name: Winni Wu Title: Sale Company: NINGBO UNIVERSAL DRAGON I/E CORP.
FCC ID: 2AUVH-KP2236S RF Exposure Evaluation 1 Measuring Standard KDB 680106 D01 RF Exposure Wireless Charging Apps v03 2 Requirements According to the item 5 of KDB 680106 D01v03: Inductive wireless power transfer applications that meet all of the following requirements are excluded from submitting an RF exposure evaluation. (1) Power transfer frequency is less than 1 MHz. (2) Output power from each primary coil is less than or equal to 15 watts. (3) The transfer system includes only single primary and secondary coils. This includes charging systems that may have multiple primary coils and clients that are able to detect and allow coupling only between individual pairs of coils. (4) Client device is placed directly in contact with the transmitter. (5) Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion). (6) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit. Remark: Meet all the above requirements. Limits The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b) Limits for Maximum Permissible Exposure (MPE) 3 Test Setup 4 Test Procedure 1) The RF exposure test was performed in anechoic chamber. 2) The measurement probe was placed at test distance (15 cm from all sides and 20 cm from the top) which is between the edge of the charger and the geometric center of probe. 3) The highest emission level was recorded and compared with limit as soon as measurement of each points (A, B, C, D, E) were completed. 4) The EUT was measured according to the dictates of KDB 680106 D01v03. Remark:The EUT’s test position A, B, C, D and E is valid for the E and H field measurements. 5 Test Instruments list Test Equipment Manufacturer Model No. SN. Cal.Date (mm-dd-yy) Cal.Due date (mm-dd-yy) Exposure Level Tester Narda ELT-400 N-0231 June. 26 2019 June. 25 2020 Magnetic field probe 100cm 2 Narda ELT probe 100cm 2 M0675 June. 26 2019 June. 25 2020 6 Test Result E-Filed Strength at 15 cm from the edges surrounding the EUT (V/m) Frequency Range (MHz) Test Position A Test Position B Test Position C Test Position D Limits (V/m) 0.1115-0.205 1.55 1.59 1.44 1.46 614 E-Filed Strength at 20 cm from the top of the EUT (V/m) Frequency Range (MHz) Test Position E Limits (V/m) 0.1115-0.205 1.39 614 H-Filed Strength at 15 cm from the edges surrounding the EUT (A/m) Frequency Range (MHz) Test Position A Test Position B Test Position C Test Position D Limits (A/m) 0.1115-0.205 0.42 0.45 0.41 0.42 1.63 H-Filed Strength at 20 cm from the top of the EUT (A/m) Frequency Range (MHz) Test Position E Limits (A/m) 0.1115-0.205 0.35 1.63 7 Test Set-up Photo
Global United Technology Services Co., Ltd. Report No.: GTS201911000204F01 Authorized Signature: Robinson Lo Laboratory Manager This results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Page 1 of 26 TEST REPORT Applicant: NINGBO UNIVERSAL DRAGON I/E CORP. Address of Applicant: 9/f Kirin Mansion,Tiantong North Road 1539#, Ningbo, China Manufacturer: NINGBO UNIVERSAL DRAGON I/E CORP. Address of Manufacturer: 9/f Kirin Mansion,Tiantong North Road 1539#, Ningbo, China Equipment Under Test (EUT) Product Name: wireless charger notebook Model No.: KP2236S FCC ID: 2AUVH-KP2236S Applicable standards: FCC CFR Title 47 Part 15 Subpart C Date of sample receipt: November 29, 2019 Date of Test: November 29, 2019-December 06, 2019 Date of report issued: December 06, 2019 Test Result : PASS * * In the configuration tested, the EUT complied with the standards specified above. Report No.: GTS201911000204F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 2 of 26 2 Version Version No. Date Description 00 December 06, 2019 Original Prepared By: Date: December 06, 2019 Project Engineer Check By: Date: December 06, 2019 Reviewer Report No.: GTS201911000204F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 3 of 26 3 Contents Page 1 COVER PAGE ............................................................................................................................................ 1 2 VERSION .................................................................................................................................................. 2 3 CONTENTS .............................................................................................................................................. 3 4 TEST SUMMARY ..................................................................................................................................... 4 4.1 MEASUREMENT UNCERTAINTY ............................................................................................................ 4 5 GENERAL INFORMATION ...................................................................................................................... 5 5.1 GENERAL DESCRIPTION OF EUT ......................................................................................................... 5 5.2 TEST MODE ........................................................................................................................................ 6 5.3 DESCRIPTION OF SUPPORT UNITS ....................................................................................................... 6 5.4 DEVIATION FROM STANDARDS ............................................................................................................. 6 5.5 ABNORMALITIES FROM STANDARD CONDITIONS ................................................................................... 6 5.6 TEST FACILITY .................................................................................................................................... 6 5.7 TEST LOCATION ................................................................................................................................. 6 5.8 OTHER INFORMATION REQUESTED BY THE CUSTOMER ......................................................................... 6 6 TEST INSTRUMENTS LIST ..................................................................................................................... 7 7 TEST RESULTS AND MEASUREMENT DATA ...................................................................................... 9 7.1 ANTENNA REQUIREMENT: .................................................................................................................... 9 7.2 CONDUCTED EMISSIONS ................................................................................................................... 10 7.3 RADIATED EMISSION METHOD ........................................................................................................... 13 7.4 20DB OCCUPY BANDWIDTH .............................................................................................................. 18 8 TEST SETUP PHOTO ............................................................................................................................ 19 9 EUT CONSTRUCTIONAL DETAILS ..................................................................................................... 21 Report No.: GTS201911000204F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 4 of 26 4 Test Summary Test Item Section in CFR 47 Result Antenna requirement 15.203 Pass AC Power Line Conducted Emission 15.207 Pass Radiated Emission 15.209 Pass 20dB Bandwidth 15.215 Pass Pass: The EUT complies with the essential requirements in the standard. 4.1 Measurement Uncertainty Test Item Frequency Range Measurement Uncertainty Notes Radiated Emission 30MHz-200MHz 3.8039dB (1) Radiated Emission 200MHz-1GHz 3.9679dB (1) AC Power Line Conducted Emission 0.15MHz ~ 30MHz 3.44dB (1) Note (1): The measurement uncertainty is for coverage factor of k=2 and a level of confidence of 95%. Report No.: GTS201911000204F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, …
Text truncated - open the document above for the full version.
Radiated Emission Conducted Emission
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.1115 MHz - 0.205 MHz | - |

10W Wireless Charger Mouse Pad
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz