2AUW9-ZOOM45Total Stations

GEOMAX AG

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Sep 17, 2024
Application Purpose
Original Equipment
Date of Application
Sep 17, 2024
Equipment Note
Total Stations
Frequency Range
2412.00000000 - 2462.00000000
Company
GEOMAX AG
Country
Switzerland

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗
↗
↗
↗

Test Report

↗
↗
↗
↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

GeoMax AG U.S. Agent Letter of Attestation To: Federal Communications Commission Date: Jul.18.2024 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Attestation Statement – Part 2.911(d)(7) filing FCC ID: 2AUW9-ZOOM45 GeoMax AG (“the applicant”) certifies that, as of the date of the filing of the application, Hexagon Geosystems Services Inc. (“the agent”) is our designated U.S. agent for service of process for the above reference FCC ID. The applicant accepts to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. The applicant further acknowledges it is our responsibility to inform the FCC whenever the agent information changes. Hexagon Geosystems Services Inc. (“the agent”) understand it is the agent's obligation to accept service of process in the United States for matters related to the applicable equipment, and at the physical U.S. address and email address. U.S. Agent Company Name: Hexagon Geosystems Services Inc. Contact Person: Sherman Banks Address: 2202 N. Redmond Road Jacksonville, AR 72076 United States Tel.: (501) 983-2039 Email: [email protected] FRN: 0033733825 U.S. Agent Signature: APPLICANT Company Name: GeoMax AG Contact Person: Hannes Juen Address: Espenstrasse 135, 9443 Widnau, Switzerland Tel.: +41 71 727 3098 Email: [email protected] FRN: 0021194253 Applicant Signature: Docusign Envelope ID: 97135D7B-F5B5-4962-BAA3-273CA85BA42E

Attestation Statements

GeoMax AG Attestation Statements Not Covered Entity Applicant To: Federal Communications Commission Date: Jul.18.2024 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Information Required by Section 2.911(d)(5)(ii) filing FCC ID: 2AUW9-ZOOM45 GeoMax AG (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely yours, Applicant Signature Printed Name: Hannes Juen Title: Director Global Quality Engineering Address: Espenstrasse 135, 9443 Widnau, Switzerland Tel.: +41 71 727 3098 Email: [email protected] Docusign Envelope ID: 97135D7B-F5B5-4962-BAA3-273CA85BA42E

Attestation Statements

GeoMax AG Attestation Statements Not Covered Equipment To: Federal Communications Commission Date: Jul.18.2024 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Information Required by Section 2.911(d)(5)(i) filing FCC ID: 2AUW9-ZOOM45 GeoMax AG (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section § 2.903 of the FCC rules. Sincerely yours, Applicant Signature Printed Name: Hannes Juen Title: Director Global Quality Engineering Address: Espenstrasse 135, 9443 Widnau, Switzerland Tel.: +41 71 727 3098 Email: [email protected] Docusign Envelope ID: 97135D7B-F5B5-4962-BAA3-273CA85BA42E

Cover Letter(s)

GeoMax AG Page 1 of 1 Authority to Act as Agent Date: Jul.18.2024 TUV Rheinland of North America, Inc. 1279 Quarry Lane., Suite. A Pleasanton, CA 94566 To Whom It May Concern: I appoint _Mr. Weidong Wang of TÜV Rheinland Shanghai Co., Ltd. to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the FCC or Industry Canada’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by TUV Rheinland Group, still resides with GeoMax AG / Espenstrasse 135, 9443 Widnau, Switzerland. For TCB applications, We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you, Agency Agreement Date: Jul.18.2024 Agreement is valid for 12 months from the above date. By: __________________________ _ Hannes Juen _ (Signature) (Print name) Director Global Quality Engineering _ +41 71 727 3098 _ (Title) (Telephone) On behalf of: GeoMax AG (Company Name) Docusign Envelope ID: 97135D7B-F5B5-4962-BAA3-273CA85BA42E

Cover Letter(s)

GeoMax AG T. +41 71 447 17 00 Espenstrasse 135 [email protected] CH-9443 Widnau, Switzerland www.geomax-positioning.com 1/1 Product Model and Configuration Statements GeoMax AG (“the applicant”) certifies that, the ZOOM45 series products are independently developed and produced by our company. There are three models as follows: - Zoom45 2" N5 - Zoom45 3" N5 - Zoom45 5" N5 Three models of product uses the same hardware, software, operating platform and operating software, the difference is only the measurement accuracy is different for market purpose. The product accuracy is customized by the production program during production, which has no impacts on EMC and RF characteristics. Sincerely, Signature Name: Hannes Juen Title: Director Global Quality Engineering Docusign Envelope ID: 8C12983D-D5DB-47E7-9C3A-600F2812AEAE

ID Label/Location Info

Zoom45 2”N5 42x42mm 42x18mm FCC Identifier

RF Exposure Info

Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: Test report no.: CN2411OF 004 Auftrags-Nr.: Order no.: 168478642 Seite 1 von 31 Page 1 of 31 Kunden-Referenz-Nr.: Client reference no.: N/A Auftragsdatum: Order date: 2024-04-29 Auftraggeber: Client: Geomax AG Espenstrasse 135, 9443 Widnau Switzerland Prüfgegenstand: Test item: Total Stations Bezeichnung / Typ-Nr.: Identification / Type no.: Zoom45 2" N5, Zoom45 3" N5, Zoom45 5" N5 Auftrags-Inhalt: Order content: Test Report Prüfgrundlage: Test specification: FCC 47 CFR § 2.1093 IEEE Std 1528-2013 IC RSS-102 Issue 6: December 2023 IEC/62209-1528: 2020 Published RF exposure KDB procedures Wareneingangsdatum: Date of sample receipt: 2024-06-05 Please refer to Photo Document Prüfmuster-Nr.: Test sample no: A003706405-001 Prüfzeitraum: Testing period: 2024-06-17 - 2024-06-19 Ort der Prüfung: Place of testing: TÜV Rheinland (Shenzhen) Co., Ltd. Prüflaboratorium: Testing laboratory: TÜV Rheinland (Shenzhen) Co., Ltd. Prüfergebnis*: Test result*: Pass geprüft von: tested by: X Signed by: Bell Hu genehmigt von: authorized by: X Signed by: Lin Lin Datum: Date: 2024-09-09 Ausstellungsdatum: Issue date: 2024-09-09 Stellung / Position: Sachverständige(r)/Expert Stellung / Position: Sachverständige(r)/Expert Sonstiges / Other: FCC ID: 2AUW9-ZOOM45 Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: P(ass) = entspricht o.g. Prüfgrundlage(n) F(ail) = entspricht nicht o.g. Prüfgrundlage(n) N/A = nicht anwendbar N/T = nicht getestet * Legend: P(ass) = passed a.m. test specification(s) F(ail) = failed a.m. test specification(s) N/A = not applicable N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the above mentioned test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark. TUV Rheinland (Shenzhen) Co., Ltd., 1601-1604, 17-18F, Tower A Building 2, Shenzhen International Innovation Valley, Dashi 1st Road, Xili Street, Xili Community, Nanshan District, Shenzhen 518052, P. R. China Mail: [email protected] · Web: www.tuv.com V101023GCNSR Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: CN2411OF 004 Test report no.: Seite 2 von 31 Page 2 of 31 Anmerkungen Remarks 1 Alle eingesetzten Prüfmittel waren zum angegebenen Prüfzeitraum gemäß eines festgelegten Kalibrierungsprogramms unseres Prüfhauses kalibriert. Sie entsprechen den in den Prüfprogrammen hinterlegten Anforderungen. Die Rückverfolgbarkeit der eingesetzten Prüfmittel ist durch die Einhaltung der Regelungen unseres Managementsystems gegeben. Detaillierte Informationen bezüglich Prüfkonditionen, Prüfequipment und Messunsicherheiten sind im Prüflabor vorhanden und können auf Wunsch bereitgestellt werden. The equipment used during the specified testing period was calibrated according to our test laboratory calibration program. The equipment fulfils the requirements included in the relevant standards. The traceability of the test equipment used is ensured by compliance with the regulations of our management system. Detailed information regarding test conditions, equipment and measurement uncertainty is available in the test laboratory and could be provided on request. 2 Wie vertraglich vereinbart, wurde dieses Dokument nur digital unterzeichnet. Der TÜV Rheinland hat nicht überprüft, welche rechtlichen oder sonstigen diesbezüglichen Anforderungen für dieses Dokument gelten. Diese Überprüfung liegt in der Verantwortung des Benutzers dieses Dokuments. Auf Verlangen des Kunden kann der TÜV Rheinland die Gültigkeit der digitalen Signatur durch ein gesondertes Dokument bestätigen. Diese Anfrage ist an unseren Vertrieb zu richten. Eine Umweltgebühr für einen solchen zusätzlichen Service wird erhoben. Informationen zur Verifizierung der Authentizität unserer Dokumente erhalten Sie auf folgender Webseite: go.tuv.com/digital-signature As contractually agreed, this document has been signed digitally only. TUV Rheinland has not verified and unable to verify which legal or other pertaining requirements are applicable for this document. Such verification is within the responsibility of the user of this document. Upon request by its client, TUV Rheinland can confirm the validity of the digital signature by a separate document. Such request shall be addressed to our Sales department. An environmental fee for such additional service will be charged. For information on verifying the authenticity of our documents, please visit the following website: go.tuv.com/digital-signature 3 Prüfklausel mit der Note * wurden an qualifizierte Unterauftragnehmer vergeben und sind unter der jeweiligen Prüfklausel des Berichts beschrieben. Abweichungen von Prüfspezifikation(en) oder Kundenanforderungen sind in der jeweiligen Prüfklausel im Bericht aufgeführt. Test clauses with remark of * are subcontracted to qualified subcontractors and descripted under the respective test clause in the report. Deviations of testing specification(s) or customer requirements are listed in specific test clause in the report. 4 Die Entscheidungsregel für Konformitätserklärungen basierend auf numerischen Messergebnisen in diesem Prüfbericht basiert auf der "Null-Grenzwert-Regel" und der "Einfachen Akzeptanz" gemäß ILAC G8:2019 und IEC Guide 115:2021, es sei denn, in der auf Seite 1 dieses Berichts genannten angewandten Norm ist etwas anderes festgelegt oder vom Kunden gewünscht. Dies bedeutet, dass die Messunsicherheit nicht berücksichtigt wird und daher auch nicht im Prüfbericht angegeben wird. Zu weiteren Informationen bezueglich des Risikos durch diese Entscheidungsregel siehe ILAC G8:2019. The de…

Text truncated - open the document above for the full version.

RF Exposure Info

Produkte Products Appendix A CN2411OF 004 Page 1 of 4 Produkte Products Appendix A CN2411OF 004 Page 2 of 4 Produkte Products Appendix A CN2411OF 004 Page 3 of 4 Produkte Products Appendix A CN2411OF 004 Page 4 of 4

RF Exposure Info

Produkte Products Appendix B CN2411OF 004 Page 1 of 10 Produkte Products Appendix B CN2411OF 004 Page 2 of 10 Produkte Products Appendix B CN2411OF 004 Page 3 of 10 Produkte Products Appendix B CN2411OF 004 Page 4 of 10 Produkte Products Appendix B CN2411OF 004 Page 5 of 10 Produkte Products Appendix B CN2411OF 004 Page 6 of 10 Produkte Products Appendix B CN2411OF 004 Page 7 of 10 Produkte Products Appendix B CN2411OF 004 Page 8 of 10 Produkte Products Appendix B CN2411OF 004 Page 9 of 10 Produkte Products Appendix B CN2411OF 004 Page 10 of 10

RF Exposure Info

Produkte Products Appendix C 50317821 001 Page 1 of 33 Produkte Products Appendix C 50317821 001 Page 2 of 33 Produkte Products Appendix C 50317821 001 Page 3 of 33 Produkte Products Appendix C 50317821 001 Page 4 of 33 Produkte Products Appendix C 50317821 001 Page 5 of 33 Produkte Products Appendix C 50317821 001 Page 6 of 33 Produkte Products Appendix C 50317821 001 Page 7 of 33 Produkte Products Appendix C 50317821 001 Page 8 of 33 Produkte Products Appendix C 50317821 001 Page 9 of 33 Produkte Products Appendix C 50317821 001 Page 10 of 33 Produkte Products Appendix C 50317821 001 Page 11 of 33 Produkte Products Appendix C 50317821 001 Page 12 of 33 Produkte Products Appendix C 50317821 001 Page 13 of 33 Produkte Products Appendix C 50317821 001 Page 14 of 33 Produkte Products Appendix C 50317821 001 Page 15 of 33 Produkte Products Appendix C 50317821 001 Page 16 of 33 Produkte Products Appendix C 50317821 001 Page 17 of 33 Produkte Products Appendix C 50317821 001 Page 18 of 33 Produkte Products Appendix C 50317821 001 Page 19 of 33 Produkte Products Appendix C 50317821 001 Page 20 of 33 Produkte Products Appendix C 50317821 001 Page 21 of 33 Produkte Products Appendix C 50317821 001 Page 22 of 33 Produkte Products Appendix C 50317821 001 Page 23 of 33 Produkte Products Appendix C 50317821 001 Page 24 of 33 Produkte Products Appendix C 50317821 001 Page 25 of 33 Produkte Products Appendix C 50317821 001 Page 26 of 33 Produkte Products Appendix C 50317821 001 Page 27 of 33 Produkte Products Appendix C 50317821 001 Page 28 of 33 Produkte Products Appendix C 50317821 001 Page 29 of 33 Produkte Products Appendix C 50317821 001 Page 30 of 33 Produkte Products Appendix C 50317821 001 Page 31 of 33 Produkte Products Appendix C 50317821 001 Page 32 of 33 Produkte Products Appendix C 50317821 001 Page 33 of 33

Test Report

Geomax AG Page 1 Specification For Approval Client: Geomax AG Espenstrasse 135, 9443 Widnau Switzerland Supplier Beijing Radiocraft Technology Co.,LTD 253, Floor 5, Unit 2, Building 5, Hounancang, Tongzhou District, Beijing Production Number RACL-GP-00-3I-001 www.top-radiocraft.com Radiocraft has possession of proprietary information provided in this specification and this proprietary information shall be kept in strict confidence and not disclosed to any person or firm without the prior written consent of Beijing Radicraft Technology Co., LTD. Page 3 1.3 Antenna Type FPC antenna. 2 TEST 2.1 Test setup  The return loss was measured with Agilent E5071.  The efficiency and gain were measured in MVG-SATIMO Chamber MVG chamber and measurement system  Measurement equipment description www.top-radiocraft.com Radiocraft has possession of proprietary information provided in this specification and this proprietary information shall be kept in strict confidence and not disclosed to any person or firm without the prior written consent of Beijing Radicraft Technology Co., LTD. Page 4 Description Manufacturer Model NoSerial No Calibrated Date Calibrated Until Agilent E5071CMY463161322023/1/132024/1/13 SATIMO MVGSG641103277-00012023/1/162024/1/16 测试软件WaveStudio2020.2.8 分析软件satenv3.0.3.0.23 2.2 Test step  The instrument is powered on and preheated for more than 30 minutes;  Turn on the darkroom power supply, connect the test cable, and set up the sample according to the standard;  Outline sets the test content objectives and conducts calibration tests;  Run the software, when the test is completed, export the corresponding test diagram and testdata, and save to the corresponding directory. 3.Electrical Performance 3.1. Return Loss www.top-radiocraft.com Radiocraft has possession of proprietary information provided in this specification and this proprietary information shall be kept in strict confidence and not disclosed to any person or firm without the prior written consent of Beijing Radicraft Technology Co., LTD. Page 5 3.2 Efficiency and Peak Gain Frequency(MHz) Efficiency(%) Peak gain Frequency(MHz) Efficiency(%) Peak gain 2400 69% 3.01 5360 64% 3.67 2410 68% 2.93 5390 64% 3.51 2420 69% 2.87 5420 65% 3.81 2430 70% 3.08 5450 66% 3.75 2440 72% 3.48 5480 64% 3.83 2450 72% 3.54 5510 66% 3.98 2460 73% 3.52 5540 63% 3.86 2470 75% 3.44 5570 63% 3.86 2480 76% 3.64 5600 64% 4.02 2490 76% 3.63 5630 61% 3.78 2500 74% 3.58 5660 63% 3.97 5150 61% 3.08 5690 63% 3.88 5180 63% 3.32 5720 59% 3.76 5210 64% 3.13 5750 59% 3.80 5240 64% 3.21 5780 58% 3.72 5270 63% 3.29 5810 58% 3.88 5300 62% 3.27 5840 59% 3.82 5330 62% 3.37 5850 58% 3.75 www.top-radiocraft.com Radiocraft has possession of proprietary information provided in this specification and this proprietary information shall be kept in strict confidence and not disclosed to any person or firm without the prior written consent of Beijing Radicraft Technology Co., LTD. Page 6 3.3 2D Pattern Phi=0 Phi=90 Theta=90 www.top-radiocraft.com Radiocraft has possession of proprietary information provided in this specification and this proprietary information shall be kept in strict confidence and not disclosed to any person or firm without the prior written consent of Beijing Radicraft Technology Co., LTD. Page 7 3.4 3D Pattern 2400MHz 2450MHz 2500MHz 5150MHz www.top-radiocraft.com Radiocraft has possession of proprietary information provided in this specification and this proprietary information shall be kept in strict confidence and not disclosed to any person or firm without the prior written consent of Beijing Radicraft Technology Co., LTD. Page 8 5510Mhz 5850Mhz 4.Parameter Electrical Antenna Model 2.4G&5G FPC antenna Frequency 2400-2500MHz&5150-5850 MHz Impedance 50Ω Polarization Omnidirectional Antenna Gain Max Gain 2.4G: 3.64 & 5G Max Gain: 4.02 S.W.R <2 Mechanical Cable RF113 Connector I-PEX 20278-112R-13 Length 120mm Operation Temperature -40°C ~80°C

Test Report

Test Report – Products Prüfbericht - Produkte Test report no.: Prüfbericht-Nr.: CN2411OF 002 Order No.: Auftragsnr.: 168478642 Page 1 of 20 Seite 1 von 20 Client reference no.: Kunden-Referenz-Nr.: N/A Order date: Auftragsdatum: 2024-04-29 Client: Auftraggeber: Geomax AG Espenstrasse 135, 9443 Widnau Switzerland Test item: Prüfgegenstand: Total Stations Identification / Type no.: Bezeichnung / Typ-Nr.: Zoom45 2" N5, Zoom45 3" N5, Zoom45 5" N5 Order content: Auftrags-Inhalt: Test Report Test specification Prüfgrundlage: CFR47 FCC Part 15: Subpart C Section 15.247 Date of sample receipt: Wareneingangsdatum: 2024-05-07 Please refer to Photo Document Test sample no: Prüfmuster-Nr.: A003706405-001~003 Testing period: Prüfzeitraum: 2024-05-20 - 2024-06-15 Place of testing: Ort der Prüfung: Refer to section 2.1 Testing laboratory: Prüflaboratorium: TÜV Rheinland (Shenzhen) Co., Ltd. Test result*: Prüfergebnis*: Pass tested by: geprüft von: X Signed by: Bell Hu authorized by: genehmigt von: X Signed by: Lin Lin Date: 2024-09-09 Datum: Issue date: 2024-09-09 Ausstellungsdatum: Position / Stellung: Expert/Sachverständige(r) Position / Stellung: Expert/Sachverständige(r) Other: Sonstiges: FCC ID: 2AUW9-ZOOM45 This report is for 2.4GHz Wi-Fi only. Condition of the test item at delivery: Zustand des Prüfgegenstandes bei Anlieferung: Test item complete and undamaged Prüfmuster vollständig und unbeschädigt * Legend: P(ass) = passed a.m. test specification(s) F(ail) = failed a.m. test specification(s) N/A = not applicable N/T = not tested * Legende: P(ass) = entspricht o.g. Prüfgrundlage(n) F(ail) = entspricht nicht o.g. Prüfgrundlage(n) N/A = nicht anwendbar N/T = nicht getestet This test report only relates to the above mentioned test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark. Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. V05 TÜV Rheinland (Shenzhen) Co., Ltd. 1601 R&D Room, 1602-1604, 17-18F, Building 7 Site C, Vanke Cloud City Phase I, Xingke First Street, Xili Street, Xili Community, Nanshan District, Shenzhen 518052, P.R. China Mail: [email protected] ∙ Web: www.tuv.com Test Report - Products Prüfbericht - Produkte Test report no.: CN2411OF 002 Prüfbericht-Nr.: Page 2 of 20 Seite 2 von 20 Remarks Anmerkungen 1 The equipment used during the specified testing period was calibrated according to our test laboratory calibration program. The equipment fulfils the requirements included in the relevant standards. The traceability of the test equipment used is ensured by compliance with the regulations of our management system. Detailed information regarding test conditions, equipment and measurement uncertainty is available in the test laboratory and could be provided on request. Alle eingesetzten Prüfmittel waren zum angegebenen Prüfzeitraum gemäß eines festgelegten Kalibrierungsprogramms unseres Prüfhauses kalibriert. Sie entsprechen den in den Prüfprogrammen hinterlegten Anforderungen. Die Rückverfolgbarkeit der eingesetzten Prüfmittel ist durch die Einhaltung der Regelungen unseres Managementsystems gegeben. Detaillierte Informationen bezüglich Prüfkonditionen, Prüfequipment und Messunsicherheiten sind im Prüflabor vorhanden und können auf Wunsch bereitgestellt werden. 2 As contractually agreed, this document has been signed digitally only. TUV Rheinland has not verified and unable to verify which legal or other pertaining requirements are applicable for this document. Such verification is within the responsibility of the user of this document. Upon request by its client, TUV Rheinland can confirm the validity of the digital signature by a separate document. Such request shall be addressed to our Sales department. An environmental fee for such additional service will be charged. Wie vertraglich vereinbart, wurde dieses Dokument nur digital unterzeichnet. Der TÜV Rheinland hat nicht überprüft, welche rechtlichen oder sonstigen diesbezüglichen Anforderungen für dieses Dokument gelten. Diese Überprüfung liegt in der Verantwortung des Benutzers dieses Dokuments. Auf Verlangen des Kunden kann der TÜV Rheinland die Gültigkeit der digitalen Signatur durch ein gesondertes Dokument bestätigen. Diese Anfrage ist an unseren Vertrieb zu richten. Eine Umweltgebühr für einen solchen zusätzlichen Service wird erhoben. 3 Test clauses with remark of * are subcontracted to qualified subcontractors and descripted under the respective test clause in the report. Deviations of testing specification(s) or customer requirements are listed in specific test clause in the report. Prüfklausel mit der Note * wurden an qualifizierte Unterauftragnehmer vergeben und sind unter der jeweiligen Prüfklausel des Berichts beschrieben. Abweichungen von Prüfspezifikation(en) oder Kundenanforderungen sind in der jeweiligen Prüfklausel im Bericht aufgeführt. 4 The decision rule for statements of conformity, based on numerical measurement results, in this test report is based on the “Zero Guard Band Rule” and “Simple Acceptance” in accordance with ILAC G8:2019 and IEC Guide 115:2021, unless otherwise specified in the applied standard mentioned on Page 1 of this report or requested by the customer. This means that measurement uncertainty is not taken in account and hence also not declared in the test report. For additional information to the resulting risk based of this decision rule please refer to ILAC G8:2019. Die Entscheidungsregel für Konformitätserklärungen basierend auf numerischen Messergebnisen in diesem Prüfbericht basiert auf der "Null-Grenzwert-Regel" und der "Einfachen Akzeptanz" gemäß ILAC G8:2019 und IEC Guide 115:2021, es sei denn, in der auf Seite 1 dieses Berichts genannten angewandten Norm ist etwas anderes festgelegt oder vom Kunden gewünsc…

Text truncated - open the document above for the full version.

Test Report

Prüfbericht - Produkte Test Report - Products Appendix B CN2411OF 002 Page 1 of 72 Appendix B: Test Results of Wi-Fi 802.11 b/g/n APPENDIX B: TEST RESULTS OF WI-FI 802.11 B/G/N.....................................................................................................1 APPENDIX B.1: TEST RESULTS OF CONDUCTED POWER SPECTRAL DENSITY......................................................................................2 APPENDIX B.2: TEST RESULTS OF 6DB BANDWIDTH....................................................................................................................9 APPENDIX B.3: TEST RESULTS OF 99% BANDWIDTH.................................................................................................................20 APPENDIX B.4: TEST RESULTS OF CONDUCTED SPURIOUS EMISSIONS MEASURED IN 100 KHZ BANDWIDTH.......................................32 APPENDIX B.5: TEST RESULTS OF RADIATED SPURIOUS EMISSIONS..............................................................................................48 30MHz - 1GHz.............................................................................................................................................................48 Above 1GHz.................................................................................................................................................................50 Prüfbericht - Produkte Test Report - Products Appendix B CN2411OF 002 Page 2 of 72 Appendix B.1: Test Results of Conducted Power Spectral Density TestModeAntennaChannelResult[dBm/3-100kHz]Limit[dBm/3kHz]Verdict Ant12412 -4.26 ≤8.00PASS Ant12437 -3.98 ≤8.00PASS 11B Ant12462 -3.49 ≤8.00PASS Ant12412 -11.10 ≤8.00PASS Ant12437 -11.71 ≤8.00PASS 11G Ant12462 -9.71 ≤8.00PASS Ant12412 -8.56 ≤8.00PASS Ant12437 -9.30 ≤8.00PASS 11N20 Ant12462 -8.68 ≤8.00PASS Ant12422 -13.41 ≤8.00PASS Ant12437 -13.39 ≤8.00PASS 11N40 Ant12452 -13.29 ≤8.00PASS Prüfbericht - Produkte Test Report - Products Appendix B CN2411OF 002 Page 3 of 72 11B: Prüfbericht - Produkte Test Report - Products Appendix B CN2411OF 002 Page 4 of 72 11G: Prüfbericht - Produkte Test Report - Products Appendix B CN2411OF 002 Page 5 of 72 Prüfbericht - Produkte Test Report - Products Appendix B CN2411OF 002 Page 6 of 72 11N20: Prüfbericht - Produkte Test Report - Products Appendix B CN2411OF 002 Page 7 of 72 11N40: Prüfbericht - Produkte Test Report - Products Appendix B CN2411OF 002 Page 8 of 72 Prüfbericht - Produkte Test Report - Products Appendix B CN2411OF 002 Page 9 of 72 Appendix B.2: Test Results of 6dB Bandwidth Minimum Emission Bandwidth 6 dB (2412 MHz; 30.000 dBm; 20 MHz(11b_20Mhz)) Test according to FCC title 47 part 15 §15.247(a), KDB 558074 D01 DTS Meas Guidance v04 and ANSI C63.10- 2013 6 dB Bandwidth DUT Frequency (MHz) Bandwidth (MHz) Limit Min (MHz) Limit Max (MHz) Band Edge Left (MHz) Band Edge Right (MHz) 2412.00000010.1500000.500000---2406.9250002417.075000 (continuation of the "6 dB Bandwidth" table from column 6 ...) DUT Frequency (MHz) Max Level (dBm) Result 2412.0000004.5PASS -50 -40 -30 -20 -10 0 10 2392 2400 2410 2420 2432 L e v e l i n d B m Frequency in MHz 6 dB Bandwidth 10.150 MHz Measurement SettingInstrument Value Target Value Start Frequency2.39200 GHz2.39200 GHz Stop Frequency2.43200 GHz2.43200 GHz Span40.000 MHz40.000 MHz RBW100.000 kHz~ 100.000 kHz VBW300.000 kHz~ 300.000 kHz SweepPoints800~ 800 Sweeptime94.922 μsAUTO Reference Level10.000 dBm10.000 dBm Attenuation30.000 dBAUTO DetectorMaxPeakMaxPeak SweepCount100100 Filter3 dB3 dB Trace ModeMax HoldMax Hold SweeptypeFFTAUTO Preampoffoff StablemodeTraceTrace Stablevalue0.50 dB0.50 dB Run17 / max. 150max. 150 Stable5 / 55 Max Stable Difference0.49 dB0.50 dB Prüfbericht - Produkte Test Report - Products Appendix B CN2411OF 002 Page 10 of 72 Minimum Emission Bandwidth 6 dB (2437 MHz; 30.000 dBm; 20 MHz(11b_20Mhz)) Test according to FCC title 47 part 15 §15.247(a), KDB 558074 D01 DTS Meas Guidance v04 and ANSI C63.10- 2013 6 dB Bandwidth DUT Frequency (MHz) Bandwidth (MHz) Limit Min (MHz) Limit Max (MHz) Band Edge Left (MHz) Band Edge Right (MHz) 2437.00000010.1500000.500000---2431.9250002442.075000 (continuation of the "6 dB Bandwidth" table from column 6 ...) DUT Frequency (MHz) Max Level (dBm) Result 2437.0000004.5PASS -50 -40 -30 -20 -10 0 10 2417 2430 2440 2450 2457 L e v e l i n d B m Frequency in MHz 6 dB Bandwidth 10.150 MHz Measurement SettingInstrument Value Target Value Start Frequency2.41700 GHz2.41700 GHz Stop Frequency2.45700 GHz2.45700 GHz Span40.000 MHz40.000 MHz RBW100.000 kHz~ 100.000 kHz VBW300.000 kHz~ 300.000 kHz SweepPoints800~ 800 Sweeptime94.922 μsAUTO Reference Level10.000 dBm10.000 dBm Attenuation30.000 dBAUTO DetectorMaxPeakMaxPeak SweepCount100100 Filter3 dB3 dB Trace ModeMax HoldMax Hold SweeptypeFFTAUTO Preampoffoff StablemodeTraceTrace Stablevalue0.50 dB0.50 dB Run14 / max. 150max. 150 Stable5 / 55 Max Stable Difference0.12 dB0.50 dB Prüfbericht - Produkte Test Report - Products Appendix B CN2411OF 002 Page 11 of 72 Minimum Emission Bandwidth 6 dB (2462 MHz; 30.000 dBm; 20 MHz(11b_20Mhz)) Test according to FCC title 47 part 15 §15.247(a), KDB 558074 D01 DTS Meas Guidance v04 and ANSI C63.10- 2013 6 dB Bandwidth DUT Frequency (MHz) Bandwidth (MHz) Limit Min (MHz) Limit Max (MHz) Band Edge Left (MHz) Band Edge Right (MHz) 2462.00000010.1500000.500000---2456.9250002467.075000 (continuation of the "6 dB Bandwidth" table from column 6 ...) DUT Frequency (MHz) Max Level (dBm) Result 2462.0000004.7PASS -50 -40 -30 -20 -10 0 10 2442 2450 2460 2470 2482 L e v e l i n d B m Frequency in MHz 6 dB Bandwidth 10.150 MHz Measurement SettingInstrument Value Target Value Start Frequency2.44200 GHz2.44200 GHz Stop Fr…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Hannes Juen(Director Global Quality Engineering)
[email protected]+41714471762Fax: +41717275098

Technical Contact

GeoMax AGHannes Juen

Espenstrasse 135 · Widnau · Switzerland

Test Firm

TUV Rheinland (Shenzhen) Co., Ltd.Gina Yang
[email protected]86 755 8268 1497

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.41 GHz - 2.46 GHz163.70 mW
Confidentiality
Long Term
Grant Notes
Power output listed is conducted. Body-worn operations are restricted to use accessories that have no metallic component in the assembly and which provide at least 1.0cm separation between the device and the user's body. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR for Body-worn and Product specific (10-g extremity SAR) are 0.48 W/kg and 2.14 W/kg. This device contains Classic Bluetooth and 5GHz U-NII band WLAN transmitters. This device has 20/40MHz bandwidth modes.

Other Applications from GEOMAX AG

Wireless Data Transceiver - FCC ID 2AUW9-TRU35 - GEOMAX AG
2AUW9-TRU35

Wireless Data Transceiver

Sep 25, 2024

Equipment Class