Equipment Class
DTS - Digital Transmission System
Date of Grant
Feb 14, 2022
Application Purpose
Original Equipment
Date of Application
Feb 14, 2022
Equipment Note
Outdoor Waterproof Beacon
Frequency Range
2402.00000000 - 2480.00000000
Company
Hangzhou Roombanker Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

User Manual Outdoor waterproof Beacon DSBC-150-1

Attestation Statements

Hangzhou Roombanker Technology Co., Ltd. Statement We Hangzhou Roombanker Technology Co., Ltd. Hereby Declare that The product Outdoor Waterproof Beacon, models no. DSBC-150-1, DSBC-150-4, DSBC-150-5, DSBC-150-6, DSBC-151-3, DSBC-151-4, DSBC-151-5, DSBC-152-1 are all identical in interior structure, electrical circuits and components, and just the model names are different for the marketing requirement. Your assistance on this matter is highly appreciated. Yours sincerely, Signature: Company Name: Hangzhou Roombanker Technology Co., Ltd.

Cover Letter(s)

February 15, 2022 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: 2AUXB-DSBC-15X Product Name: Outdoor Waterproof Beacon Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commissions rules, we hereby request that the following documents be held confidential: • Schematics • Block diagram • Operation description These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. <Signature>: Name:Su Lin Title: Applicant Company:Hangzhou Roombanker Technology Co., Ltd.

Cover Letter(s)

Febr Fede Auth 7345 Colu On o C, 1s Villa to ac that certi f defin labe For i beha for c Ltd <Sig n Name Title: Applic ruary 15, 20 eral Commu horization & 5 Oakland M umbia, Mary our behalf, I st Floor, Blo ge, Nansha ct as our age submitted d fication is so ned in the Fe l identical to instances w alf, I acknow certification, ./ A#801 W a nature>: e:Su Lin cant Compa 022 unications C Evaluation D Mills Road land 21046 appoint She ock B, Jun X n District, S ent in the pr documents p ought. I also ederal Comm o that submit where our au wledge that still resides antong cent any:Hangz ommission Division Author i enzhen Time Xiang Da Bui henzhen, C reparation of properly desc o certify that munications tted for appr uthorized ag all responsi with Han er, Hangzho zhou Room ity to Act as eway Testin ilding, Zhon hina (Name f this applica cribe the de each unit m s Commissio roval with th ent signs th ibility for com gzhou Ro ou, Zhejiang banker Tec s Agent ng Laborator gshan Park of Agent co ation for equ evice or syst manufactured on’s regulatio his applicatio he applicatio mplying with oombanke g, China chnology Co ries/ Zone C Road West ompany nam uipment cert em for which d, imported ons will hav on. on for certific h the terms er Techno o., Ltd. C, 1st Floor, t, Tong Le me and addr tification. I c h equipme n or marketed ve affixed to cation on ou and conditio ology Co Zone ress) ertify t d, as it a ur ons .,

ID Label/Location Info

Label Location

RF Exposure Info

Maximum Permissible Exposure FCC ID: 2AUXB-DSBC-15X Applicable Standard Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess limit for maximum permissible exposure. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as a mobile device whereby a distance of 0.2m normally can be maintained between the user and the device. (a) Limits for Occupational / Controlled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/cm 2 ) Averaging Times ︱E︱ 2 , ︱H︱ 2 or S (minutes) 0.3-3.0 614 1.63 (100)* 6 3.0-30 1842/f 4.89/f (900/f)* 6 30-300 61.4 0.163 1.0 6 300-1500 F/300 6 1500-100000 5 6 (b) Limits for General Population / Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/cm 2 ) Averaging Times ︱E︱ 2 , ︱H︱ 2 or S (minutes) 0.3-1.34 614 1.63 (100)* 30 1.34-30 824/f 2.19/f (180/f)* 30 30-300 27.5 0.073 0.2 30 300-1500 F/1500 30 1500-100000 1.0 30 Note: f=frequency in MHz; *Plane-wave equivalent power density MPE Calculation Method E (V/m) = (30*P*G) 0.5 /d Power Density: Pd (W/m 2 ) = E 2 /377 E = Electric Field (V/m) P = Peak RF output Power (W) G = EUT Antenna numeric gain (numeric) d = Separation distance between radiator and human body (m) The formula can be changed to Pd = (30*P*G) / (377*d 2 ) From the peak EUT RF output power, the minimum mobile separation distance, d=0.2m, as well as the gain of the used antenna, the RF power density can be obtained. Calculated Result and Limit Antenna Gain: 2.0dBi Assembly Antenna Gain (Numeric) Output Power (dBm) Peak Output Power (mW) Power Density (S) (mW/cm 2 ) Limit of Power Density (S) (mW/cm 2 ) Test Result 1.585 9.37 8.65 0.003 1 Compiles Note: the worse case was recorded.

Test Report

Report No.: TW2112290E File Reference No.: 2022-01-14 Applicant: Hangzhou Roombanker Technology Co., Ltd. Product: Outdoor Waterproof Beacon Model No.: DSBC-150-1, DSBC-150-4, DSBC-150-5, DSBC-150-6, DSBC-151-3, DSBC-151-4, DSBC-151-5, DSBC-152-1 Trademark: N/A Test Standards: FCC Part 15.247 Test Result: It is herewith confirmed and found to comply with the requirements set up by ANSI C63.10, FCC Part 15.247 for the evaluation of electromagnetic compatibility Approved By Jack Chung Manager Dated: January 14, 2022 Results appearing herein relate only to the sample tested The technical reports is issued errors and omissions exempt and is subject to withdrawal at SHENZHEN TIMEWAY TESTING LABORATORIES Zone C, 1st Floor, Block B, Jun Xiang Da Building, Zhongshan Park Road West, Tong Le Village, Nanshan District, Shenzhen, China Tel (755) 83448688, Fax (755) 83442996, E-Mail:[email protected] Report No.: TW2112290E Page 2 of 46 Date: 2022-01-14 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. Special Statement: The testing quality ability of our laboratory meet with “Quality Law of People’s Republic of China” Clause 19. The testing quality system of our laboratory meet with ISO/IEC-17025 requirements, which is approved by CNAL. This approval result is accepted by MRA of APLAC. Our test facility is recognized, certified, or accredited by the following organizations: CNAS-LAB Code: L2292 The EMC Laboratory has been assessed and in compliance with CNAS-CL01 accreditation criteria for testing Laboratories (identical to ISO/IEC 17025:2005 General Requirements) for the Competence of testing Laboratories. FCC-Registration No.: 744189 The EMC Laboratory has been registered and fully described in a report filed with the (FCC) Federal Communications commission. The acceptance letter from the FCC is maintained in our files. Registration No.: 744189. Industry Canada (IC) —Registration No.:5205A The EMC Laboratory has been registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with Registration No.: 5205A. A2LA (Certification Number:5013.01) The EMC Laboratory has been accredited by the American Association for Laboratory Accreditation (A2LA). Certification Number:5013.01 Report No.: TW2112290E Page 3 of 46 Date: 2022-01-14 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. Test Report Conclusion Content 1.0 General Details ................................................................................................ 4 1.1 Test Lab Details................................................................................................ 4 1.2 Applicant Details.............................................................................................. 4 1.3 Description of EUT ........................................................................................... 4 1.4 Submitted Sample.............................................................................................. 4 1.5 Test Duration................................................................................................... 5 1.6 Test Uncertainty............................................................................................... 5 1.7 Test By.......................................................................................................... 5 2.0 List of Measurement Equipment......................................................................... 6 3.0 Technical Details............................................................................................. 7 3.1 Summary of Test Results..................................................................................... 7 3.2 Test Standards.................................................................................................. 7 4.0 EUT Modification............................................................................................. 7 5.0 Power Line Conducted Emission Test...................................................................... 8 5.1 Schematics of the Test........................................................................................ 8 5.2 Test Method and Test Procedure............................................................................ 8 5.3 Configuration of the EUT..................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Radiated Emission Test Setup:

Contact Information

Applicant

Lin Su
[email protected]0571-86769027Fax: 0571-86769027

Test Firm

Shenzhen Timeway Testing LaboratoriesTerry Tang
[email protected]+86-755-83448688

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz8.65 mW
Confidentiality
Long Term
Grant Notes
Power output listed is conducted.The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Hangzhou Roombanker Technology Co., Ltd.

Smart Gateway - FCC ID 2AUXBDSGW-095 - Hangzhou Roombanker Technology Co., Ltd.
2AUXBDSGW-095

Smart Gateway

Aug 13, 2024

Equipment Class

DTS - Digital Transmission System
Medical Portable Gateway - FCC ID 2AUXBDSGW-340 - Hangzhou Roombanker Technology Co., Ltd.
2AUXBDSGW-340

Medical Portable Gateway

Aug 13, 2024

Equipment Class

JAB - Part 15 Class B Digital Device
Industrial AI Edge Computing Gateway - FCC ID 2AUXBDSGW-380 - Hangzhou Roombanker Technology Co., Ltd.
2AUXBDSGW-380

Industrial AI Edge Computing Gateway

Aug 12, 2024

Equipment Class

PCB - PCS Licensed Transmitter
PIR Sensor - FCC ID 2AUXBRBSS-PS1915 - Hangzhou Roombanker Technology Co., Ltd.
2AUXBRBSS-PS1915

PIR Sensor

Mar 14, 2024

Equipment Class

JAB - Part 15 Class B Digital Device
2AUXBDSBC-230

AOA Tag

Jan 30, 2024

Equipment Class

JAB - Part 15 Class B Digital Device