2AUXB-DSBC120beacon /Bluetooth card beacon

Hangzhou Roombanker Technology Co., Ltd.

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jan 31, 2021
Application Purpose
Original Equipment
Date of Application
Jan 31, 2021
Equipment Note
beacon /Bluetooth card beacon
Frequency Range
2402.00000000 - 2480.00000000
Company
Hangzhou Roombanker Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Card beacon User Manual ※Product Introduction Users can take this product for personnel positioning, check-in and other functions, and use it with gateways or mobile apps. Otherwise, Support iBeacon and Eddystone ※How to use 1. Power on In the Power-off state, long press the power key for 5s, the LED will flash 3 times at 1Hz, which means the power on is successful 2. Power off In the power-on state, press and hold the power key for 15s, the LED will flash 5 times at 2Hz, which means the power on is successful 3. Low voltage alarm In the power-on state, if the battery level is less than 20%, the LED light will flash once every 10s ※Items Not Under Warranty 1. Unauthorized repairs ,misuse, collisions, negligence, abuse ,exposure of product to moisture or water, accidents ,alteration, improper use of accessories, tearing or alteration of stickers or anti-counterfeiting marks. 2. The validity period of the warranty has passed 3. Damage caused by force majeure, damage or malfunction caused by problems other than the design ,technology, manufacturing quality of prouduct. FCC Warning Statement Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Cover Letter(s)

January 28, 2021 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: 2AUXB-DSBC120 Product Name: beacon /Bluetooth card beacon Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commissions rules, we hereby request that the following documents be held confidential: • Schematics • Block diagram • Operation description These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. <Signature>: Name:Su Lin Title: Applicant Company:Hangzhou Roombanker Technology Co., Ltd.

Cover Letter(s)

January 28, 2021 Federal Communications Commission Authorization & Evaluation Division 7345 Oakland Mills Road Columbia, Maryland 21046 Authority to Act as Agent On our behalf, I appoint Shenzhen Timeway Testing Laboratories/ Zone C, 1st Floor, Zone C, 1st Floor, Block B, Jun Xiang Da Building, Zhongshan Park Road West, Tong Le Village, Nanshan District, Shenzhen, China (Name of Agent company name and address) to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the Federal Communications Commission’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, still resides with Hangzhou Roombanker Technology Co., Ltd./ A#801 Wantong center, Hangzhou, Zhejiang, China <Signature>: Name:Su Lin Title: Applicant Company:Hangzhou Roombanker Technology Co., Ltd.

ID Label/Location Info

Laabel Locationn Label Location

RF Exposure Info

FCC ID: 2AUXB-DSBC120 RF Exposure Applicable Standard According to §1.1307(b)(5), systems operating under the provisions of this section shall be operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess of the Commission’s guideline. This is a Portable device. The Section 4.3.1 and Appendix A of KDB447498 D01 V05 was used as the guidance. Calculation Result (Worse case) [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] · [√f(GHz)] =0.401/5 * 1.55= 0.12, this value is less than 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR. The SAR measurement is not necessary.

Test Report

Report No.: TW20101170E File reference No.: 2021-01-26 Applicant: Hangzhou Roombanker Technology Co., Ltd. Product: beacon /Bluetooth card beacon Model No.: DSBC-120 Trademark: N/A Test Standards: FCC Part 15.247 Test result: It is herewith confirmed and found to comply with the requirements set up by ANSI C63.10, FCC Part 15.247 for the evaluation of electromagnetic compatibility Approved By Jack Chung Manager Dated: January 26, 2021 Results appearing herein relate only to the sample tested The technical reports is issued errors and omissions exempt and is subject to withdrawal at SHENZHEN TIMEWAY TESTING LABORATORIES Zone C, 1st Floor, Block B, Jun Xiang Da Building, Zhongshan Park Road West, Tong Le Village, Nanshan District, Shenzhen, China Tel (755) 83448688, Fax (755) 83442996, E-Mail:[email protected] Report No.: TW2101170EPage 2 of 47 Date: 2021-01-26 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. Special Statement The testing quality ability of our laboratory meet with Quality Law of Peoples Republic of China Clause 19. The testing quality system of our laboratory meet with ISO/IEC-17025 requirements, which is approved by CNAL. This approval result is accepted by MRA of APLAC. Our test facility is recognized, certified, or accredited by the following organizations: CNAL-LAB Code: L2292 The EMC Laboratory has been assessed and in compliance with CNAL/AC01:2002 accreditation criteria for testing Laboratories (identical to ISO/IEC 17025:2005 General Requirements) for the Competence of testing Laboratories. FCC-Registration No.: 744189 The EMC Laboratory has been registered and fully described in a report filed with the (FCC) Federal Communications commission. The acceptance letter from the FCC is maintained in our files. Registration No.: 744189. Industry Canada (IC) Registration No.:5205A The EMC Laboratory has been registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with Registration No.: 5205A. A2LA (Certification Number:5013.01) The EMC Laboratory has been accredited by the American Association for Laboratory Accreditation (A2LA). Certification Number:5013.01 Report No.: TW2101170EPage 3 of 47 Date: 2021-01-26 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. Test Report Conclusion Content 1.0 General Details 4 1.1 Test Lab Details. 4 1.2 Applicant Details. 4 1.3 Description of EUT ... 4 1.4 Submitted Sample... 5 1.5 Test Duration 5 1.6 Test Uncertainty.. 5 1.7 Test By. 5 2.0 List of Measurement Equipment 6 3.0 Technical Details 7 3.1 Summary of Test Results. 7 3.2 Test Standards.. 7 4.0 EUT Modification 7 5.0 Power Line Conducted Emission Test. 8 5.1 Schematics of the Test. 8 5.2 Test Method and Test Procedure. 8 5.3 Configuration of the EUT 8 5.4 EUT Operating Condition 9 5.5 Conducted Emission Limit.. 9 5.6 Test Result... 9 6.0 Radiated Emission test.. 10 6.1 Test Method and Test Procedure. 10 6.2 Configuration of the EUT 11 6.3 EUT Operation Condition 11 6.4 Radiated Emission Limit. 11 7.0 6dB Bandwidth Measurement Bandwidth....... 21 8.0 Maximum Peak Output Power.... 26 9.0 Power Spectral Density Measurement. 28 10.0 Out of Band Measurement.. 33 11.0 Antenna .. 40 12.0 FCC ID Label.. 41 13.0 Photo of Test Setup and EUT View. 42 Report No.: TW2101170EPage 4 of 47 Date: 2021-01-26 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. 1.0 General Details 1.1 Test Lab Details Name : SHENZHEN TIMEWAY TESTING LABORATORIES. Address:…

Text truncated - open the document above for the full version.

Test Setup Photos

Radiatedd Emission Teest Setup:

Contact Information

Applicant

Lin Su
[email protected]0571-86769027Fax: 0571-86769027

Test Firm

Shenzhen Timeway Testing LaboratoriesTerry Tang
[email protected]+86-755-83448688

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz401.00 µW
Confidentiality
Long Term
Grant Notes
Power output listed is conducted

Other Applications from Hangzhou Roombanker Technology Co., Ltd.

Smart Gateway - FCC ID 2AUXBDSGW-095 - Hangzhou Roombanker Technology Co., Ltd.
2AUXBDSGW-095

Smart Gateway

Aug 13, 2024

Equipment Class

DTS - Digital Transmission System
Medical Portable Gateway - FCC ID 2AUXBDSGW-340 - Hangzhou Roombanker Technology Co., Ltd.
2AUXBDSGW-340

Medical Portable Gateway

Aug 13, 2024

Equipment Class

JAB - Part 15 Class B Digital Device
Industrial AI Edge Computing Gateway - FCC ID 2AUXBDSGW-380 - Hangzhou Roombanker Technology Co., Ltd.
2AUXBDSGW-380

Industrial AI Edge Computing Gateway

Aug 12, 2024

Equipment Class

PCB - PCS Licensed Transmitter
PIR Sensor - FCC ID 2AUXBRBSS-PS1915 - Hangzhou Roombanker Technology Co., Ltd.
2AUXBRBSS-PS1915

PIR Sensor

Mar 14, 2024

Equipment Class

JAB - Part 15 Class B Digital Device
2AUXBDSBC-230

AOA Tag

Jan 30, 2024

Equipment Class

JAB - Part 15 Class B Digital Device