Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
mLink MP290 Portable Wireless Gateway User Manual V1.0 MP290 Portable Wireless Gateway 2 (C) mPower Electronics (Shanghai) Co., Ltd. Rev. 2019-5 目录 1. Product Overview .............................................................................................................................. 3 2. Operation ............................................................................................................................................. 4 2.1. Power On ...................................................................................................................................................... 4 2.2. Power Off ..................................................................................................................................................... 5 2.3. Activate Bluetooth ....................................................................................................................................... 5 2.4. Alarm Indication ......................................................................................................................................... 5 2.5. Charging ....................................................................................................................................................... 5 3. User Interface ...................................................................................................................................... 5 3.1. mPower Suite App ....................................................................................................................................... 5 3.2. Operating Environment .............................................................................................................................. 6 3.2.1. Hardware Requirement ...................................................................................................................................... 6 3.2.2. System Requirement ............................................................................................................................................. 6 3.2.3. Operating Environment Requirement .................................................................................................................... 6 3.3. Operation ..................................................................................................................................................... 6 3.3.1. Search and connect detectors ................................................................................................................................ 6 3.3.2. Disconnect the detectors ........................................................................................................................................ 8 3.3.3. Shortcut buttons .................................................................................................................................................... 8 3.3.4. mLink Operation ................................................................................................................................................... 8 3.4. Software Information ................................................................................................................................ 14 3.4.1. EULA .................................................................................................................................................................. 14 3.4.2. Software Setting .................................................................................................................................................. 15 3.4.3. Data Logging ....................................................................................................................................................... 16 3.4.4. Event Log ............................................................................................................................................................ 18 3.4.5. Software Log ....................................................................................................................................................... 19 MP290 Portable Wireless Gateway 3 (C) mPower Electronics (Shanghai) Co., Ltd. Rev. 2019-5 Read Before Operating This manual must be carefully read by all individuals who have or will have the responsibility of using, maintaining or servicing this product. The product will perform as designed only if it is used, maintained and serviced in accordance with the manufacturer’s instructions. The user should understand how to set the correct parameters and interpret the obtained results. WARNINGS ! This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CAUTION: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipmen…
Text truncated - open the document above for the full version.
3046 Scott Blvd. Santa Clara, CA 95054 Toll Free: +1(866)mPower7 Santa Clara, CA • Pasadena, TX • Shanghai, CHINA • www.mpowerinc.com • HQ Office: (408) 320-1266 Authority to Act as Agent Date: ___ July 2, 2020_____ American Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 To Whom It May Concern: ______Intertek Testing Services Shanghai______ is authorized to act on our behalf, until otherwise notified, for applications to American Certification Body, Inc. (ACB). We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you, Agency Agreement Expiration Date: _____ July 2, 2021_____ By: ____ ____Hong Sun______ (Signature) (Print name) Title: ______President____________ On behalf of: _____ mPower Electronics, Inc. _ (Company Name) Telephone: _____1.866.676.9377____________
3046 Scott Blvd. Santa Clara, CA 95054 Toll Free: +1(866)mPower7 Santa Clara, CA • Pasadena, TX • Shanghai, CHINA • www.mpowerinc.com • HQ Office: (408) 320-1266 Request for Confidentiality Date: ___July 2, 2020___ Subject: Confidentiality Request for: ____FCC ID: 2AUXFMP290P______ Pursuant to FCC 47 CRF 0.457(d) and 0.459 and IC RSP-100, Section 9.4, the applicant requests that a part of the subject FCC application be held confidential. Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagrams Short Term External Photos Short Term Permanent Internal Photos Short Term Permanent Operation Description/Theory of Operation Short Term Permanent Parts List & Placement/BOM Short Term Permanent Tune-Up Procedure Short Term Permanent Schematics Short Term Test Setup Photos Short Term Permanent User’s Manual ____mPower Electronics, Inc. __ has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of ___(specify number of days not to exceed 180) 1 ___ days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify ACB in the event information regarding the product or the product is made available to the public. ACB will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. NOTE for Industry Canada Applications: IC currently only distinguishes Permanent Confidentiality exhibits as shown above. Short Term confidentiality is not considered applicable to IC applications. Sincerely, By: President Hong Sun (Signature/Title 2 ) (Print name) 1 - Please refer to http://acbcert.com/documents/misc-docs/Memo-Short-Term-Vs-Standard-Confidentiality.pdf for complete details. 2 - Must be signed by applicant contact given for applicant on the FCC site, or by the authorized agent if an appropriate authorized agent letter has been provided. Letters should be placed on appropriate letterhead.
FCC ID: 2AUXFMP290P Page 1 of 4 External Picture FCC ID: 2AUXFMP290P Page 2 of 4 FCC ID: 2AUXFMP290P Page 3 of 4 FCC ID: 2AUXFMP290P Page 4 of 4
FCC ID: 2AUXFMP290P Page 1 of 4 Internal Picture FCC ID: 2AUXFMP290P Page 2 of 4 FCC ID: 2AUXFMP290P Page 3 of 4 FCC ID: 2AUXFMP290P Page 4 of 4 RF Module RF Module
mPower Electronics, Inc. SAR COMPLIANCE REPORT Report Type: FCC SAR assessment report Model: MP290P REPORT NUMBER: 200502182SHA-002 ISSUE DATE: October 26, 2020 DOCUMENT CONTROL NUMBER: TTRFFCCSAR-01_V1 © 2018 Intertek Intertek Testing Services Shanghai Building No.86, 1198 Qinzhou Road (North) Caohejing Development Zone Shanghai 200233, China Telephone: 86 21 6127 8200 www.intertek.com TEST REPORT This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. TTRFFCCSAR-01_V1© 2018 Intertek Page 2 of 9 Report no.: 200502182SHA-002 Applicant: mPower Electronics, Inc. 3046 Scott Blvd. Santa Clara, CA 95054 Manufacturer: mPower Electronics, Inc. 3046 Scott Blvd. Santa Clara, CA 95054 FCC ID: 2AUXFMP290P SUMMARY: The equipment complies with the requirements according to the following standard(s) or Specification: KDB 447498 D01 General RF Exposure Guidance v06 FCC Part2.1091, FCC Part2.1093 FCC Part1.1307(b) PREPARED BY: REVIEWED BY: Project Engineer Erick Liu Reviewer Daniel Zhao Report No.: 200502182SHA-002 TEST REPORT TTRFFCCSAR-01_V1© 2018 Intertek Page 3 of 9 Revision History Report No. Version Description Issued Date 200502182SHA-002 Rev. 01 Initial issue of report October 26, 2020 Report No.: 200502182SHA-002 TEST REPORT TTRFFCCSAR-01_V1© 2018 Intertek Page 4 of 9 1 GENERAL INFORMATION 1.1 Description of Equipment Under Test (EUT) Product name: MP290P Type/Model: MP290P Description of EUT: The EUT is a gateway platform for real-time forwarding or uploading terminal device data using the 902 ~ 928MHz frequency band, it also has BLE and GPS function. Rating: 3.7V Battery Adapter: input: 100-240V~, 50/60Hz, 0.5A output:6.0V DC, 2.0A EUT type: Table top Floor standing Software Version: / Hardware Version: / Sample received date: July 12, 2020 Date of test: July 14, 2020 – August 10, 2020 1.2 Technical Specification Frequency Range: 904.5MHz to 927MHz Type of Modulation: LoRa Channel Number: 16 Channel Separation: 1.5MHz Antenna: 2.5dBi, Pole antenna Report No.: 200502182SHA-002 TEST REPORT TTRFFCCSAR-01_V1© 2018 Intertek Page 5 of 9 1.3 Description of Test Facility Name: Intertek Testing Services Shanghai Address: Building 86, No. 1198 Qinzhou Road(North), Shanghai 200233, P.R. China Telephone: 86 21 61278200 Telefax: 86 21 54262353 The test facility is recognized, certified, or accredited by these organizations: CNAS Accreditation Lab Registration No. CNAS L0139 FCC Accredited Lab Designation Number: CN1175 IC Registration Lab CAB identifier.: CN0051 VCCI Registration Lab Registration No.: R-14243, G-10845, C-14723, T-12252 A2LA Accreditation Lab Certificate Number: 3309.02 Report No.: 200502182SHA-002 TEST REPORT TTRFFCCSAR-01_V1© 2018 Intertek Page 6 of 9 2 SAR Assessment Test result: Pass 2.1 SAR Test Exclusion Limit 100 MHz – 6 GHz and ≤ 50 mm Report No.: 200502182SHA-002 TEST REPORT TTRFFCCSAR-01_V1© 2018 Intertek Page 7 of 9 100 MHz – 6 GHz and > 50 mm < 100 MHz and < 200 mm Report No.: 200502182SHA-002 TEST REPORT TTRFFCCSAR-01_V1© 2018 Intertek Page 8 of 9 2.2 Assessment Results Seen from the original test report 200502182SHA-001: The Maximum peak output power = 18.19dBm = 65.92mW; The Maximum Antenna Gain = 2.5dBi = 1.78; According to measured value from Appendix I, duty cycle = 0.3%; After SAR distance assessment, the separation distance is 5mm; The time-averaged radiated power = 65.92mW * 1.78 * 0.3% = 0.35mW < 16mW (Test Exclusion Thresholds of 900MHz at 5mm) Report No.: 200502182SHA-002 TEST REPORT TTRFFCCSAR-01_V1© 2018 Intertek Page 9 of 9 Appendix I: Duty Cycle calculation The test data with maximum duty cycle was listed below. The worst Duty cycle= 0.184/ 60.2 =0.003 **************************************** END ****************************************
mPower Electronics, Inc. RF TEST REPORT Report Type: FCC Part 15.247 & ISED RSS-247 RF report Model: MP290P REPORT NUMBER: 200502182SHA-001 ISSUE DATE: October 26, 2020 DOCUMENT CONTROL NUMBER: TTRF15.247-02_V1 © 2018 Intertek Intertek Testing Services Shanghai Building No.86, 1198 Qinzhou Road (North) Caohejing Development Zone Shanghai 200233, China Telephone: 86 21 6127 8200 www.intertek.com TEST REPORT This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. TTRF15.247-02_V1 © 2018 Intertek Page 2 of 40 Report no.: 200502182SHA-001 Applicant: mPower Electronics, Inc. 3046 Scott Blvd. Santa Clara, CA 95054 Manufacturer: mPower Electronics, Inc. 3046 Scott Blvd. Santa Clara, CA 95054 FCC ID: 2AUXFMP290P SUMMARY: The equipment complies with the requirements according to the following standard(s) or Specification: 47CFR Part 15 (2019): Radio Frequency Devices (Subpart C) ANSI C63.10 (2013): American National Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices RSS-247 Issue 2 (February 2017): Digital Transmission Systems (DTSs), Frequency Hopping Systems (FHSs) and Licence- Exempt Local Area Network (LE-LAN) Devices RSS-Gen Issue 5, Amendment 1(March 2019): General Requirements for Compliance of Radio Apparatus PREPARED BY: REVIEWED BY: Project Engineer Erick Liu Reviewer Daniel Zhao Report No.: 200502182SHA-001 TEST REPORT TTRF15.247-02_V1 © 2018 Intertek Page 3 of 40 Content REVISION HISTORY ....................................................................................................................................................... 5 MEASUREMENT RESULT SUMMARY ............................................................................................................................. 6 1 GENERAL INFORMATION ..................................................................................................................................... 7 1.1 DESCRIPTION OF EQUIPMENT UNDER TEST (EUT) ............................................................................................................. 7 1.2 TECHNICAL SPECIFICATION ............................................................................................................................................. 7 1.3 DESCRIPTION OF TEST FACILITY ....................................................................................................................................... 8 2 TEST SPECIFICATIONS........................................................................................................................................... 9 2.1 STANDARDS OR SPECIFICATION ....................................................................................................................................... 9 2.2 MODE OF OPERATION DURING THE TEST ........................................................................................................................... 9 2.3 TEST SOFTWARE LIST .................................................................................................................................................. 10 2.4 TEST PERIPHERALS LIST ............................................................................................................................................... 10 2.5 TEST ENVIRONMENT CONDITION: .................................................................................................................................. 10 2.6 INSTRUMENT LIST ...................................................................................................................................................... 11 2.7 MEASUREMENT UNCERTAINTY ..................................................................................................................................... 12 3 MINIMUM 6DB BANDWIDTH ............................................................................................................................ 13 3.1 LIMIT ...................................................................................................................................................................... 13 3.2 MEASUREMENT PROCEDURE ....................................................................................................................................... 13 3.3 TEST CONFIGURATION ................................................................................................................................................ 13 3.4 TEST RESULTS OF MINIMUM 6DB BANDWIDTH................................................................................................................ 13 4 MAXIMUM CONDUCTED OUTPUT POWER AND E.I.R.P. ..................................................................................... 14 4.1 LIMIT ...................................................................................................................................................................... 14 4.2 MEASUREMENT PROCEDURE ....................................................................................................................................... 14 4.3 TEST CONFIGURATION ................................................................…
Text truncated - open the document above for the full version.
FCC ID: 2AUXFMP290P Page 1 of 5 Test Setup FCC ID: 2AUXFMP290P Page 2 of 5 Conducted Emission FCC ID: 2AUXFMP290P Page 3 of 5 Radiated Emission Below 1000MHz FCC ID: 2AUXFMP290P Page 4 of 5 Above 1000MHz FCC ID: 2AUXFMP290P Page 5 of 5 RF Test
Building No.86, 1198 Qinzhou Road(North) · Shanghai · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 904.5 MHz - 927 MHz | 65.90 mW |

MP420
Equipment Class
DTS - Digital Transmission System
MP280B
Equipment Class
DTS - Digital Transmission System