FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Realme Chongqing Mobile Telecommunications Corp., Ltd./
  3. 2AUYFRMX3624

2AUYFRMX3624Mobile Phone with GSM, WCDMA, LTE, NFC, WiFi and Bluetooth

Realme Chongqing Mobile Telecommunications Corp., Ltd.
Mobile Phone with GSM, WCDMA, LTE, NFC, WiFi and Bluetooth - FCC ID 2AUYFRMX3624 - Realme Chongqing Mobile Telecommunications Corp., Ltd.
Click to zoom

Application Details

Equipment Class
PCE - PCS Licensed Transmitter held to ear
Date of Grant
Jul 31, 2022
Application Purpose
Original Equipment
Date of Application
Jul 27, 2022
Equipment Note
Mobile Phone with GSM, WCDMA, LTE, NFC, WiFi and Bluetooth
Frequency Range
1710.70000000 - 1779.30000000
Company
Realme Chongqing Mobile Telecommunications Corp., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗
↗
↗
↗
↗

Test Report

↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

This mobile phone complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) this device must accept any interference received, including interference that may cause undesired operation. This mobile phone has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiated radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment o and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. FCC Regulations: Caution: Changes or modifications not expressly approved by the party responsible for compliance could void the user‘s authority to operate the equipment. FCC Note: This device is complied with SAR for general population /uncontrolled exposure limits in ANSI/IEEE C95.1-1992 and had been tested in accordance with the measurement methods and procedures specified in IEEE1528. The FCC has granted an Equipment Authorization for this model phone with all reported SAR levels evaluated as in compliance with the FCC RF exposure guidelines. SAR information on this model phone is on file with the FCC and can be found under the Display Grant section of www.fcc.gov/oet/ea/fccid after searching on FCC ID: 2AUYFRMX3624 For this device, the highest reported SAR value for usage against the head is XXX W/kg, for usage near the body is XXX W/kg. Whi le there may be dierences between the SAR levels of various phones and at various positions, they all meet the government requirements. SAR compliance for body-worn operation is based on a separation distance of XX mm between the unit and the human body. Carry this device at least XX mm away from your body to ensure RF exposure level compliant or lower to the reported level. To support body-worn operation, choose the belt clips or holsters, which do not contain metallic components, to maintain a separation of XX mm between this device and your body. RF exposure compliance with any body-worn accessory, which contains metal, was not tested and certified, and use such body-worn accessory should be avoided. RF Exposure Information (SAR) This phone is designed and manufactured not to exceed the emission limits for exposure to radio frequency (RF) energy set by the Federal Communications Commission of the United States. During SAR testing, this device was set to transmit at its highest certified power level in all tested frequency bands, and placed in positions that simulate RF exposure in usage against the head with no separation, and near the body with the separation of 1.5 cm. Although the SAR is determined at the highest certified power level, the actual SAR level of the device while operating can be well below the maximum value. This is because the phone is designed to operate at multiple power levels so as to use only the power required to reach the network. In general, the closer you are to a wireless base station antenna, the lower the power output. The exposure standard for wireless devices employing a unit of measurement is known as the Specific Absorption Rate, or SAR. The SAR limit set by the FCC is 1.6W/kg. Regulatory Steps to search E-label : Go to Settings -About Phone - Certicate Information. RMX3624 4890mAh/18.92Wh(Min) 5000mAh/19.35Wh(Typ) 16.5cm(6.5'') 164.2×75.7×8.3(mm) RMX3624 Radio Waves Specifications English 6.5) 16.5( RMX3624 4890mAh/18.92Wh(Min) 5000mAh/19.35Wh(Typ) 164.2×75.7×8.3 0.793W/kg(Head) 0.755W/kg(Body) X.XXW/kg X.XXW/kg FCC SAR FCC SAR realme realme realme / realme realme Front Camera ReceiverProximity sensor & Light sensor Power Key / Fingerprint Scanner Volume Key 50 Megapixels + 0.3 Megapixels Rear 5 Megapixels Front 50 5 0.3 Radio GSM WCDMA LTE FDD LTE TDD Bluetooth 2.4G Wi-Fi Frequency Max. Output Power 850MHz 900MHz 1800MHz 1900MHz Bands 1/5/8 Bands 2/4 Bands 1/2/3/4/66 Band 7 Bands 5/8/13/20/28 Bands 38/41 2.4-2.4835GHz 2.4-2.4835GHz 13.56MHz 33.5dBm 33.5dBm 30.5dBm 30.5dBm 24.5dBm 24dBm 24dBm 23.5dBm 24.5dBm 24dBm 12.5dBm(EIRP) 21dBm(EIRP) 42dBμA/m @10m NFC GSM WCDMA LTE FDD LTE TDD Bluetooth 2.4G Wi-Fi NFC 850MHz 900MHz 1800MHz 1900MHz Bands 1/5/8 Bands 2/4 Bands 1/2/3/4/66 Band 7 Bands 5/8/13/20/28 Bands 38/41 2.4-2.4835GHz 2.4-2.4835GHz 13.56MHz 33.5dBm 33.5dBm 30.5dBm 30.5dBm 24.5dBm 24dBm 24dBm 23.5dBm 24.5dBm 24dBm 12.5dBm(EIRP) 21dBm(EIRP) 42dBμA/m @10m

Cover Letter(s)

Realme Chongqing Mobile Telecommunications Corp., Ltd PHOENIX TESTLAB GmbH Date: 22 July 2022 Product Certification Königswinkel 10 D 32825 Blomberg RE : LETTER OF AGENCY AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize Zhou Fangai at Shenzhen Academy of Metrology and Quality Inspection to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse ACT of 1988, U.S.C.862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. This agreement is valid for one year – until 19-07-2023 If you have any questions, please feel free to contact me Yours sincerely, Signatory: Printed Name:Yang Liangping Position:Compliance Manager

Cover Letter(s)

Realme Chongqing Mobile Telecommunications Corp., Ltd Long/Short-term Confidentiality Request PHOENIX TESTLAB GmbH Date: 22 July 2022 Product Certification Königswinkel 10 D 32825 Blomberg FCC ID: 2AUYFRMX3624 To Whom It May Concerns, Pursuant to sections 0.457(d) and 0.459 of CFR 47 and to avoid premature release of sensitive information prior to marketing or release of the product to the public, we hereby request long-term confidential treatment of information accompanying this application as outlined below: ☒ Schematics ☒ Parts List ☒ Block Diagram ☒ Tune-Up Info ☒ Operational Description In addition we hereby request the following exhibits contained in this application to be temporarily (short-term confidentiality) withheld from the public disclosure ☒ for an initial period of 180 days ☐ until: ☐ not applicable ☒ External Photos ☒ Test Setup Photos ☒ Internal Photos ☒ Users Manual The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to rule 0.457(d), disclosure of this application and all accompanying documentation will not be made before the date of the GRANT for this application. If you have any questions, please feel free to contact me. Yours sincerely, Signatory: Printed Name:Yang Liangping Position:Compliance Manager

External Photos

Photo 1 Appearance of EUT Photo 2 Appearance of EUT Photo 3 Appearance of EUT Photo 4 Appearance of EUT Photo 5 Appearance of EUT Photo 6 Appearance of EUT Photo 7 Appearance of adapter (OP52YAUH) Photo 8 Appearance of adapter (OP52YAUH) Photo 9 Appearance of adapter (OP52JAUH) Photo 10 Appearance of adapter (OP52JAUH) Photo 11 Appearance of USB Cable

ID Label/Location Info

IMEI2: xxxxxxxxxxxxxxxx IMEI1: xxxxxxxxxxxxxxxx S/N: xxxxxxxx Model: RMX3624 FCC ID: 2AUYFRMX3624 Mobile Phone Designed by realmeAssembled in China Realme Chongqing Mobile Telecommunications Corp., Ltd.

Internal Photos

Photo 1 Inside of EUT GSM/WCDMA/LTE Diversity Antenna BT/WiFi Antenna GSM/WCDMA/LTE Main Antenna NFC Antenna Photo 2 Inside of EUT Photo 3 Inside of EUT Photo 4 Inside of EUT Photo 5 Inside of EUT Photo 6 Inside of EUT Photo 7 Inside of EUT Photo 8 Inside of EUT Photo 9 Inside of EUT Photo 10 Inside of EUT Photo 11 Inside of EUT Photo 12 Inside of EUT

RF Exposure Info

ReportNo.:WT228001726Page1of7 APPENDIXA:SYSTEMCHECKINGSCANS ReportNo.:WT228001726Page2of7 Dipole750Date/Time:2022-07-16 CommunicationSystem:UID0,GenericGSM;CommunicationSystemBand:GSM750(747.0-763.0MHz); Frequency:755MHz;CommunicationSystemPAR:9.191dB;PMF:2.88104 Mediumparametersused(interpolated):f=755MHz;σ=0.904S/m;ε r =41.79;ρ=1000kg/m 3 Phantomsection:FlatSection MeasurementStandard:DASY6(IEEE/IEC/ANSIC63.19-2007) DASYConfiguration:  Probe:EX3DV4–SN7623;ConvF(9.43,9.43,9.43)@835MHz;Calibrated:2022-01-24  Sensor-Surface:4mm(MechanicalSurfaceDetection),z=1.0,31.0  Electronics:DAE4Sn1636;Calibrated:2021-12-30  Phantom:SAM3;Type:QD000P41AA;  DASY5252.10.4(1527);SEMCADX14.6.14(7483) Configuration/Dipole750MHz3/AreaScan(61x131x1):Interpolatedgrid:dx=1.500mm,dy=1.500mm ReferenceValue=49.77V/m;PowerDrift=0.05dB FastSAR:SAR(1g)=2.1W/kg;SAR(10g)=1.39W/kg MaximumvalueofSAR(interpolated)=2.28W/kg Configuration/Dipole750MHz3/ZoomScan(5x5x7)/Cube0:Measurementgrid:dx=8mm,dy=8mm,dz=5mm ReferenceValue=49.77V/m;PowerDrift=0.05dBPeakSAR(extrapolated)=3.37W/kg SAR(1g)=2.12W/kg;SAR(10g)=1.34W/kg Smallestdistancefrompeakstoallpoints3dBbelow=17.2mm RatioofSARatM2toSARatM1=63.8% MaximumvalueofSAR(measured)=2.30W/kg 0dB=2.28W/kg=3.57dBW/kg ReportNo.:WT228001726Page3of7 Date/Time:2022-07-13 Dipole835V2 CommunicationSystem:UID0,CW;CommunicationSystemBand:D835(835.0MHz);Frequency:835 MHz;CommunicationSystemPAR:0dB;PMF:1 Mediumparametersused:f=835MHz;σ=0.94S/m;εr=42.05;ρ=1000kg/m3 Phantomsection:FlatSection MeasurementStandard:DASY6(IEEE/IEC/ANSIC63.19-2007) DASYConfiguration: Probe:EX3DV4–SN7623;ConvF(9.43,9.43,9.43)@835MHz;Calibrated:2022-01-24 Sensor-Surface:4mm(MechanicalSurfaceDetection),z=1.0,31.0 Electronics:DAE4Sn1636;Calibrated:2021-12-30 Phantom:SAM3;Type:QD000P41AA; DASY5252.10.4(1527);SEMCADX14.6.14(7483) Head/Dipole835/AreaScan(61x131x1):Interpolatedgrid:dx=1.500mm,dy=1.500mm ReferenceValue=60.83V/m;PowerDrift=0.02dB FastSAR:SAR(1g)=2.49W/kg;SAR(10g)=1.58W/kg MaximumvalueofSAR(interpolated)=3.88W/kg Head/Dipole835/ZoomScan(5x5x7)/Cube0:Measurementgrid:dx=8mm,dy=8mm,dz=5mm ReferenceValue=60.83V/m;PowerDrift=0.02dB PeakSAR(extrapolated)=3.75W/kg SAR(1g)=2.39W/kg;SAR(10g)=1.54W/kg Smallestdistancefrompeakstoallpoints3dBbelow=17.6mm RatioofSARatM2toSARatM1=65.3%MaximumvalueofSAR(measured)=3.31W/kg 0dB=3.88W/kg=5.20dBW/kg ReportNo.:WT228001726Page4of7 Date/Time:2022-07-15 Dipole1750V2 CommunicationSystem:CW;CommunicationSystemBand:D1750(1750.0MHz);Frequency:1750 MHz;DutyCycle:1:1 Mediumparametersused:f=1750MHz;σ=1.34S/m;εr=39.50;ρ=1000kg/m3 Phantomsection:FlatSection MeasurementStandard:DASY6(IEEE/IEC/ANSIC63.19-2007) DASYConfiguration: Probe:EX3DV4-SN7623;ConvF(8.59,8.59,8.59)@1750MHz;Calibrated:2022-01-24 Sensor-Surface:4mm(MechanicalSurfaceDetection),z=1.0,31.0 Electronics:DAE4Sn1636;Calibrated:2021-12-30 Phantom:SAM3;Type:QD000P41AA; DASY5252.10.4(1527);SEMCADX14.6.14(7483) Head/Dipole1800/AreaScan(61x131x1):Interpolatedgrid:dx=1.500mm,dy=1.500mm ReferenceValue=96.99V/m;PowerDrift=-0.13dB FastSAR:SAR(1g)=8.92W/g;SAR(10g)=4.66W/g MaximumvalueofSAR(interpolated)=14.01W/kg Head/Dipole1800/ZoomScan(5x5x7)/Cube0:Measurementgrid:dx=8mm,dy=8mm,dz=5mm ReferenceValue=96.99V/m;PowerDrift=-0.13dB PeakSAR(extrapolated)=16.4W/g SAR(1g)=8.77W/g;SAR(10g)=4.64W/g Smallestdistancefrompeakstoallpoints3dBbelow=9.9mm RatioofSARatM2toSARatM1=53.0%MaximumvalueofSAR(measured)=13.52W/kg 0dB=14.01W/kg=11.09dBW/kg ReportNo.:WT228001726Page5of7 Date/Time:2022-07-17 Dipole1900V2 CommunicationSystem:UID0,CW;CommunicationSystemBand:D1900(1900.0MHz);Frequency: 1900MHz;CommunicationSystemPAR:0dB;PMF:1 Mediumparametersused:f=1900MHz;σ=1.42S/m;ε r =39.91;ρ=1000kg/m 3 Phantomsection:FlatSection MeasurementStandard:DASY6(IEEE/IEC/ANSIC63.19-2007) DASYConfiguration: Probe:EX3DV4-SN7623;ConvF(8.59,8.59,8.59)@1900MHz;Calibrated:2022-01-24 Sensor-Surface:4mm(MechanicalSurfaceDetection),z=1.0,31.0 Electronics:DAE4Sn1636;Calibrated:2021-12-30 Phantom:SAM3;Type:QD000P41AA; DASY5252.10.4(1527);SEMCADX14.6.14(7483) Head/Dipole1900/AreaScan(61x61x1):Interpolatedgrid:dx=1.500mm,dy=1.500mm ReferenceValue=103.6V/m;PowerDrift=0.16dB FastSAR:SAR(1g)=9.94W/kg;SAR(10g)=5.04W/kg MaximumvalueofSAR(interpolated)=16.8W/kg Head/Dipole1900/ZoomScan(5x5x7)/Cube0:Measurementgrid:dx=8mm,dy=8mm,dz=5mm ReferenceValue=103.6V/m;PowerDrift=0.16dB PeakSAR(extrapolated)=19.0W/kg SAR(1g)=9.79W/kg;SAR(10g)=5.01W/kg Smallestdistancefrompeakstoallpoints3dBbelow=10.2mm RatioofSARatM2toSARatM1=50.4% MaximumvalueofSAR(measured)=16.1W/kg 0dB=16.8W/kg=12.21dBW/kg ReportNo.:WT228001726Page6of7 Date/Time:2022-07-19 Dipole2450V2 CommunicationSystem:UID0,CW;CommunicationSystemBand:D2450(2450.0MHz);Frequency: 2450MHz;CommunicationSystemPAR:0dB;PMF:1 Mediumparametersused:f=2450MHz;σ=1.74S/m;ε r =39.96;ρ=1000kg/m 3 Phantomsection:FlatSection MeasurementStandard:DASY6(IEEE/IEC/ANSIC63.19-2007) DASYConfiguration: Probe:EX3DV4-SN7623;ConvF(8.07,8.07,8.07)@2450MHz;Calibrated:2022-01-24 Sensor-Surface:4mm(MechanicalSurfaceDetection),z=1.0,31.0 Electronics:DAE4Sn1636;Calibrated:2021-12-30 Phantom:SAM3;Type:QD000P41AA; DASY5252.10.4(1527);SEMCADX14.6.14(7483) Head/Dipole2450/AreaScan(61x61x1):Interpolatedgrid:dx=1.500mm,dy=1.500mm ReferenceValue=110.8V/m;PowerDrift=-0.03dB FastSAR:SAR(1g)=13.32W/kg;SAR(10g)=6.09W/kg MaximumvalueofSAR(interpolated)=23.7W/kg Head/Dipole2450/ZoomScan(5x5x7)/Cube0:Measurementgrid:dx=8mm,dy=8mm,dz=5mm ReferenceValue=110.8V/m;PowerDrift=-0.03dB PeakSAR(extrapolated)=28.0W/kg SAR(1g)=13.22W/kg;SAR(10g)=6.05W/kg Smallestdistancefrompeakstoallpoints3dBbelow=8.9mm RatioofSARatM2toSARatM1=46.4% MaximumvalueofSAR(measured)=23.1W/kg 0dB=23.7W/kg=14.11dBW/kg ReportNo.:WT228001726Page7of7 Date/Time:2022-07-21 Dipole2600V2 CommunicationSystem:UID0,CW;CommunicationSystemBand:D2600(2600.0MHz);Frequency: 2600MHz;CommunicationSystemPAR:0dB;PMF:1 Mediumparametersused:f=2600MHz;σ=1.93S/m;ε r =38.24;ρ=1000kg/m 3 Phantomsection:FlatSection MeasurementStand…

Text truncated - open the document above for the full version.

RF Exposure Info

ReportNo.:WT228001726Page 1 of 46 AppendixB.MEASUREMENTSCANS ReportNo.:WT228001726Page 2 of 46 Date/Time:2022-07-13 GSM850HeadRightCheekLow CommunicationSystem:UID10001,GenericGSM;CommunicationSystemBand:GSM850(824.0- 849.0MHz);Frequency:824.2MHz;CommunicationSystemPAR:9.191dB;PMF:2.88104 Mediumparametersused(interpolated):f=824.2MHz;σ=0.88S/m;ε r =41.628;ρ=1000kg/m 3 Phantomsection:RightSection MeasurementStandard:DASY6(IEEE/IEC/ANSIC63.19-2007) DASYConfiguration:  Probe:EX3DV4-SN7623;ConvF(9.9,9.9,9.9)@824.2MHz;Calibrated:2022-01-24  Sensor-Surface:4mm(MechanicalSurfaceDetection),z=31.0 Electronics:DAE4Sn1636;Calibrated:2021-12-30 Phantom:SAM3;Type:QD000P41AA;Serial:2025 DASY5252.10.4(1527);SEMCADX14.6.14(7483) GSM850_RightCheek/Low/AreaScan(61x61x1):Interpolatedgrid:dx=1.500mm,dy=1.500mm ReferenceValue=3.436V/m;PowerDrift=0.11dB FastSAR:SAR(1g)=0.163W/kg;SAR(10g)=0.105W/kg MaximumvalueofSAR(interpolated)=0.175W/kg GSM850_RightCheek/Low/ZoomScan(5x5x7)/Cube0:Measurementgrid:dx=8mm,dy=8mm, dz=5mm ReferenceValue=3.436V/m;PowerDrift=0.11dB PeakSAR(extrapolated)=0.284W/kg SAR(1g)=0.177W/kg;SAR(10g)=0.118W/kg Smallestdistancefrompeakstoallpoints3dBbelow=10.2mm RatioofSARatM2toSARatM1=82.5% MaximumvalueofSAR(measured)=0.187W/kg 0dB=0.175W/kg=-7.14dBW/kg ReportNo.:WT228001726Page 3 of 46 Date/Time:2022-07-13 GSM850BodyFacedownMid10mm CommunicationSystem:UID10001,GenericGSM;CommunicationSystemBand:GSM850(824.0- 849.0MHz);Frequency:836.6MHz;CommunicationSystemPAR:9.191dB;PMF:2.88104 Mediumparametersused(interpolated):f=836.6MHz;σ=0.88S/m;ε r =41.628;ρ=1000kg/m 3 Phantomsection:FlatSection MeasurementStandard:DASY6(IEEE/IEC/ANSIC63.19-2007) DASYConfiguration:  Probe:EX3DV4-SN7623;ConvF(9.9,9.9,9.9)@836.6MHz;Calibrated:2022-01-24  Sensor-Surface:4mm(MechanicalSurfaceDetection),z=1.0,31.0 Electronics:DAE4Sn1636;Calibrated:2021-12-30 Phantom:SAM3;Type:QD000P41AA;Serial:2025 DASY5252.10.4(1527);SEMCADX14.6.14(7483) GSM850_Front/FacedownMid10mm/AreaScan(61x61x1):Interpolatedgrid:dx=1.500mm, dy=1.500mm ReferenceValue=13.88V/m;PowerDrift=0.06dB FastSAR:SAR(1g)=0.304W/kg;SAR(10g)=0.198W/kg MaximumvalueofSAR(interpolated)=0.334W/kg GSM850_Front/FacedownMid10mm/ZoomScan(5x5x7)/Cube0:Measurementgrid:dx=8mm, dy=8mm,dz=5mm ReferenceValue=13.88V/m;PowerDrift=0.06dB PeakSAR(extrapolated)=0.611W/kg SAR(1g)=0.307W/kg;SAR(10g)=0.186W/kg Smallestdistancefrompeakstoallpoints3dBbelow=15.8mm RatioofSARatM2toSARatM1=63.2% MaximumvalueofSAR(measured)=0.327W/kg 0dB=0.334W/kg=-4.76dBW/kg ReportNo.:WT228001726Page 4 of 46 Date/Time:2022-07-13 GSM850BodyFacedownLow15mm CommunicationSystem:UID10001,GenericGSM;CommunicationSystemBand:GSM850(824.0- 849.0MHz);Frequency:824.2MHz;CommunicationSystemPAR:9.191dB;PMF:2.88104 Mediumparametersused(interpolated):f=824.2MHz;σ=0.88S/m;ε r =41.628;ρ=1000kg/m 3 Phantomsection:FlatSection MeasurementStandard:DASY6(IEEE/IEC/ANSIC63.19-2007) DASYConfiguration:  Probe:EX3DV4-SN7623;ConvF(9.9,9.9,9.9)@824.2MHz;Calibrated:2022-01-24  Sensor-Surface:4mm(MechanicalSurfaceDetection),z=1.0,31.0 Electronics:DAE4Sn1636;Calibrated:2021-12-30 Phantom:SAM3;Type:QD000P41AA;Serial:2025 DASY5252.10.4(1527);SEMCADX14.6.14(7483) GSM850_Front/FacedownLow15mm/AreaScan(61x61x1):Interpolatedgrid:dx=1.500mm, dy=1.500mm ReferenceValue=12.71V/m;PowerDrift=0.09dB FastSAR:SAR(1g)=0.220W/kg;SAR(10g)=0.155W/kg MaximumvalueofSAR(interpolated)=0.232W/kg GSM850_Front/FacedownLow15mm/ZoomScan(5x5x7)/Cube0:Measurementgrid:dx=8mm, dy=8mm,dz=5mm ReferenceValue=12.71V/m;PowerDrift=0.09dB PeakSAR(extrapolated)=0.431W/kg SAR(1g)=0.221W/kg;SAR(10g)=0.168W/kg Smallestdistancefrompeakstoallpoints3dBbelow=10.4mm RatioofSARatM2toSARatM1=76.7% MaximumvalueofSAR(measured)=0.233W/kg 0dB=0.232W/kg=-6.34dBW/kg ReportNo.:WT228001726Page 5 of 46 Date/Time:2022-07-17 GSM1900HeadLeftCheekMid CommunicationSystem:UID0,GenericGSM;CommunicationSystemBand:PCS1900(1850.0- 1910.0MHz);Frequency:1880MHz;CommunicationSystemPAR:9.191dB;PMF:2.88104 Mediumparametersused:f=1880MHz;σ=1.45S/m;ε r =39.74;ρ=1000kg/m 3 Phantomsection:LeftSection MeasurementStandard:DASY6(IEEE/IEC/ANSIC63.19-2007) DASYConfiguration:  Probe:EX3DV4-SN7623;ConvF(8.28,8.28,8.28)@1880MHz;Calibrated:2022-01-24  Sensor-Surface:4mm(MechanicalSurfaceDetection),z=31.0 Electronics:DAE4Sn1636;Calibrated:2021-12-30 Phantom:SAM3;Type:QD000P41AA;Serial:2025 DASY5252.10.4(1527);SEMCADX14.6.14(7483) 1900_LeftGSMHead/1900GSMCheek-Mid/AreaScan(61x61x1):Interpolatedgrid:dx=1.500 mm,dy=1.500mm ReferenceValue=0.6770V/m;PowerDrift=0.10dB FastSAR:SAR(1g)=0.063W/kg;SAR(10g)=0.028W/kg MaximumvalueofSAR(interpolated)=0.071W/kg 1900_LeftGSMHead/1900GSMCheek-Mid/ZoomScan(5x5x7)/Cube0:Measurementgrid: dx=8mm,dy=8mm,dz=5mm ReferenceValue=0.6770V/m;PowerDrift=0.10dB PeakSAR(extrapolated)=0.104W/kg SAR(1g)=0.052W/kg;SAR(10g)=0.024W/kg Smallestdistancefrompeakstoallpoints3dBbelow=9.1mm RatioofSARatM2toSARatM1=61.8% MaximumvalueofSAR(measured)=0.066W/kg 0dB=0.071W/kg=-10.47dBW/kg ReportNo.:WT228001726Page 6 of 46 Date/Time:2022-07-17 GSM1900BodyBottomLow10mm CommunicationSystem:UID10001,GenericGSM;CommunicationSystemBand:PCS1900(1850.0 -1910.0MHz);Frequency:1850.2MHz;CommunicationSystemPAR:9.191dB;PMF:2.88104 Mediumparametersused:f=1850.2MHz;σ=1.42S/m;ε r =39.87;ρ=1000kg/m 3 Phantomsection:FlatSection MeasurementStandard:DASY6(IEEE/IEC/ANSIC63.19-2007) DASYConfiguration:  Probe:EX3DV4-SN7623;ConvF(8.28,8.28,8.28)@1850.2MHz;Calibrated:2022-01-24  Sensor-Surface:4mm(MechanicalSurfaceDetection),z=1.0,31.0 Electronics:DAE4Sn1636;Calibrated:2021-12-30 Phantom:SAM3;Type:QD000P41AA;Serial:2025 DASY5252.10.4(1527);SEMCADX14.6.14(7483) 1900_GSM1900/Gsm1900BottomLow/AreaScan(61x61x1):Interpolatedgrid:dx=1.500mm, dy=1.500mm ReferenceValue=19.85V/m;PowerDrift=-0.02dB FastSAR:SAR(1g)=0.501W/kg;SAR(10g)=0.267W/kg MaximumvalueofSAR(interpolated)=0.569W/kg 1900_GSM1900/Gsm1900BottomLow/ZoomScan(5x5x7)/Cube0:Measurementgrid:dx=8mm, dy=8mm,dz=5mm ReferenceValue=19.85V/m;PowerDrift=-0.02dB PeakSAR(extrapola…

Text truncated - open the document above for the full version.

RF Exposure Info

ReportNo.:WT228001726Page1of26 APPENDIXC:RELEVANTPAGESFROMPROBE CALIBRATIONREPORT(S) ReportNo.:WT228001726Page2of26 ReportNo.:WT228001726Page3of26 ReportNo.:WT228001726Page4of26 ReportNo.:WT228001726Page5of26 ReportNo.:WT228001726Page6of26 ReportNo.:WT228001726Page7of26 ReportNo.:WT228001726Page8of26 ReportNo.:WT228001726Page9of26 ReportNo.:WT228001726Page10of26 ReportNo.:WT228001726Page11of26 ReportNo.:WT228001726Page12of26 ReportNo.:WT228001726Page13of26 ReportNo.:WT228001726Page14of26 ReportNo.:WT228001726Page15of26 ReportNo.:WT228001726Page16of26 ReportNo.:WT228001726Page17of26 ReportNo.:WT228001726Page18of26

RF Exposure Info

ReportNo.:WT228001726Page19of26 ReportNo.:WT228001726Page20of26 ReportNo.:WT228001726Page21of26 ReportNo.:WT228001726Page22of26 ReportNo.:WT228001726Page23of26 ReportNo.:WT228001726Page24of26 ReportNo.:WT228001726Page25of26 ReportNo.:WT228001726Page26of26

RF Exposure Info

ReportNo.:WT228001726Page1of46 APPENDIXD:RELEVANTPAGESFROMDAE& DIPOLEVALIDATIONKITREPORT(S) ReportNo.:WT228001726Page2of46 ReportNo.:WT228001726Page3of46 ReportNo.:WT228001726Page4of46 ReportNo.:WT228001726Page5of46 ReportNo.:WT228001726Page6of46 ReportNo.:WT228001726Page7of46 ReportNo.:WT228001726Page8of46 ReportNo.:WT228001726Page9of46 ReportNo.:WT228001726Page10of46 D750V3-SN:1103 750MHz-Head Dateof Measurement Retum- Loss (dB) Delta(%) Real Impedance (Ω) Delta(Ω) Imaginary Impedance (Ω) Delta(Ω) 2020.01.06-26.81753.916-2.673 2021.01.05-27.168-0.01352.1271.789-2.8620.189 2022.01.05-27.632-0.0351.7662.15-3.0130.34 Thereturnlossis<-20dB,within20%ofpriorcalibration;theimpedanceiswithin5 Ω ofprior calibration. Thereforetheverificationresultshouldsupportextendedcalibration. ReportNo.:WT228001726Page11of46 ReportNo.:WT228001726Page12of46 ReportNo.:WT228001726Page13of46 ReportNo.:WT228001726Page14of46 ReportNo.:WT228001726Page15of46 ReportNo.:WT228001726Page16of46 ReportNo.:WT228001726Page17of46 ReportNo.:WT228001726Page18of46 ReportNo.:WT228001726Page19of46 ReportNo.:WT228001726Page20of46 ReportNo.:WT228001726Page21of46 ReportNo.:WT228001726Page22of46 ReportNo.:WT228001726Page23of46 ReportNo.:WT228001726Page24of46 D1750V3-SN:1108 ReportNo.:WT228001726Page25of46 1750MHz-Head Dateof Measurement Retum- Loss (dB) Delta(%) Real Impedance (Ω) Delta(Ω) Imaginary Impedance (Ω) Delta(Ω) 2020.01.03-39.74849.211-0.647 2021.01.02-39.962-0.00548.6330.578-0.6930.046 2022.01.02-40.156-0.0149.1260.085-0.6850.038 Thereturnlossis<-20dB,within20%ofpriorcalibration;theimpedanceiswithin5 Ω ofprior calibration. Thereforetheverificationresultshouldsupportextendedcalibration. ReportNo.:WT228001726Page26of46 ReportNo.:WT228001726Page27of46 ReportNo.:WT228001726Page28of46 ReportNo.:WT228001726Page29of46 ReportNo.:WT228001726Page30of46 ReportNo.:WT228001726Page31of46 ReportNo.:WT228001726Page32of46 ReportNo.:WT228001726Page33of46 ReportNo.:WT228001726Page34of46 ReportNo.:WT228001726Page35of46 ReportNo.:WT228001726Page36of46 ReportNo.:WT228001726Page37of46 ReportNo.:WT228001726Page38of46 ReportNo.:WT228001726Page39of46 ReportNo.:WT228001726Page40of46 ReportNo.:WT228001726Page41of46 ReportNo.:WT228001726Page42of46 ReportNo.:WT228001726Page43of46 ReportNo.:WT228001726Page44of46 ReportNo.:WT228001726Page45of46 ReportNo.:WT228001726Page46of46 D2600V3-SN:1074 2600MHz-Head Dateof Measurement Retum- Loss (dB) Delta(%) Real Impedance (Ω) Delta(Ω) Imaginary Impedance (Ω) Delta(Ω) 2020.01.02-23.10849.118-6.891 2021.12.30-24.566-0.06348.3690.749-7.0230.132 Thereturnlossis<-20dB,within20%ofpriorcalibration;theimpedanceiswithin5 Ω ofprior calibration. Thereforetheverificationresultshouldsupportextendedcalibration.

RF Exposure Info

ReportNo.:WT228001726Page 1 of 120 SARTESTREPORT For MobilePhone ModelNumber:RMX3624 FCCID:2AUYFRMX3624 ReportNumber:WT228001726 TestLaboratory:ShenzhenAcademyofMetrologyandQuality Inspection NationalDigitalElectronicProductTestingCenter SiteLocation:NETCBuilding,No.4TongfaRoad,XiliTown, NanshanDistrict,Shenzhen,Guangdong,China Tel:0086-755-86928965 Fax:0086-755-86009898-31396 Web:www.smq.com.cn Email:[email protected] ReportNo.:WT228001726Page 2 of 120 Testreportdeclaration Applicant:RealmeChongqingMobileTelecommunicationsCorp.,Ltd. Address: No.178YulongAvenue,Yufengshan,YubeiDistrict, Chongqing,China Manufacturer:RealmeChongqingMobileTelecommunicationsCorp.,Ltd. Address: No.178YulongAvenue,Yufengshan,YubeiDistrict, Chongqing,China EUTDescription:MobilePhone ModelNo.:RMX3624 Brand:realme FCCID:2AUYFRMX3624 TestStandards: FCC47CFRPart2(2.1093)IEEEStd1528-2013KDB447498D01v06KDB248227D01v02r02KDB 865664D01v01r04KDB865664D02v01r02KDB648474D04v01r03KDB941225D01v03r01KDB 941225D05v02r05KDB941225D06v02r01 TheEUTdescribedaboveistestedbyShenzhenAcademyofMetrologyandQualityInspectionEMC Laboratorytodeterminethecomplianceoftheapplicablestandardsstatedabove.ShenzhenAcademyof MetrologyandQualityInspectionEMCLaboratoryisassumedfullresponsibilityfortheaccuracyofthetest results. Theresultsdocumentedinthisreportonlyapplytothetestedsample,undertheconditionsandmodesof operationasdescribedherein. Thetestreportshallnotbereproducedinpartwithoutwrittenapprovalofthelaboratory. ProjectEngineer: Date: Jul.23,2022 (ZhangQiang) Checkedby: Date: Jul.23,2022 (ShiChangDa) Approvedby: Date: Jul.23,2022 (LinYiXiang) ReportNo.:WT228001726Page 3 of 120 TABLEOFCONTENTS 1.REPORTEDSARSUMMARY..............................................................................................................5 1.1.StatementofCompliance .......................................................................................................5 1.2.RFexposurelimits(ICNIRPGuidelines)..............................................................................6 1.3.RatingsandSystemDetails ...................................................................................................7 1.4.Testspecification(s) ..................................................................................................................8 1.5.ListofTestandMeasurementInstruments..........................................................................9 2.GENERALINFORMATION .................................................................................................................11 2.1.Reportinformation .................................................................................................................11 2.2.LaboratoryAccreditationandRelationshiptoCustomer .................................................11 3.SARMEASUREMENTSYSTEMCONFIGURATION ....................................................................12 3.1.SARMeasurementSet-up ...................................................................................................12 3.2.Probedescription...................................................................................................................13 3.3.Phantomdescription..............................................................................................................14 3.4.Deviceholderdescription.....................................................................................................15 4.SARMEASUREMENTPROCEDURE..............................................................................................16 4.1.Scanningprocedure..............................................................................................................16 7.SYSTEMVERIFICATIONPROCEDURE .........................................................................................22 7.1.TissueVerification .................................................................................................................22 8.SARMEASUREMENTVARIABILITYANDUNCERTAINTY........................................................26 8.1.SARmeasurementvariability ..............................................................................................26 8.2.SARmeasurementuncertainty............................................................................................26 9.TestConfiguration ................................................................................................................................27 10.ARTESTRESULTS ..........................................................................................................................39 10.1.EUTAntennaLocations......................................................................................................39 11.TUNE-UPLIMIT..................................................................................................................................40 11.1.Tune-upLimit.......................................................................................................................40 12.MEASUREMENTRESULTS............................................................................................................49 12.1.ConductedPower................................................................................................................49 12.2.SARmeasurementResults................................................................................................96 ReportNo.:WT228001726Page 4 of 120 12.16.BTSARresults................................................................................................................112 12.17.2.4GWi-FiSARresults ...................................................................................................113 12.18.RepeatedSARresults ....................................................................................................114 13.EXPOSUREPOSITIONSCONSIDERATION ......................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Mega Huang(Manager)
[email protected]18502096102Fax: 86 76986076999

Test Firm

Shenzhen Academy of Metrology and Quality InspecMs. Alice Hou
[email protected]86-755-86928932

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
35271.71 GHz - 1.78 GHz102.00 mW1M08W7D2.5 ppm
Confidentiality
Long Term
Grant Notes
Output power listed for GSM850, WCDMA Band 5, LTE Band 5/13 are maximum ERP. Output power listed for PCS1900, WCDMA Band 2/4, LTE Band 2/4/7/38/41/66 are maximum EIRP. It supports GSM, WCDMA, LTE (QPSK, 16QAM, 64QAM for downlink and QPSK, 16QAM for uplink) LTE B2, B4, B5, B7, B13, B38, B41, B66. Channel Bandwidth (1.4/3/5/10 MHz) for LTE B5, Channel Bandwidth (1.4/3/5/10/15/20 MHz) for LTE B2, B4, B66 Channel Bandwidth (5/10 MHz) for LTE B13, Channel Bandwidth (5/10/15/20 MHz) for LTE B7, B38, B41; This device contains functions that are not operational in U.S. Territories; this filing is only applicable for U.S. operations. This device has integrated DXX, DTS, DSS and PCE transmitters certified under the same FCC ID. SAR compliance for body-worn operating configurations is limited to the belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 15 mm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for Head, body-worn accessory, hotspot and simultaneous transmission use conditions are 0.26 W/kg, 0.30 W/kg, 0.68 W/kg and 0.94 W/kg, respectively.

Other Applications from Realme Chongqing Mobile Telecommunications Corp., Ltd.

2AUYFRMX3951

Mobile Phone

Jul 15, 2024

Equipment Class

CXX - Communications Rcvr for use w/ licensed Tx and CBs
2AUYFRMW2401

Smart Watch

Jun 27, 2024

Equipment Class

DTS - Digital Transmission System
2AUYFRMX3921

Mobile Phone

Jun 27, 2024

Equipment Class

DTS - Digital Transmission System
2AUYFRMX3939

Mobile Phone with GSM, WCDMA, LTE, WiFi, Bluetooth and NFC

Apr 02, 2024

Equipment Class

DTS - Digital Transmission System
2AUYFRMX3851

Mobile Phone

Mar 27, 2024

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral