Installation & Pairing Manual Smarter Control Solutions. i FCC This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/ TV technician for help. FCC AND INDUSTRY CANADA RF Radiation Exposure statement: This equipment complies with FCC and Industry Canada RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters between the antenna and all persons. Cet appareil est conforme aux limites d’exposition au rayonnement FR du FCC et d’Industrie Canada pour un environnement non contrôlé. Cet appareil devrait être installé et devrait fonctionner de sorte qu’il se trouve à une distance d’au moins 20 cm entre l’antenne et toute personne. INDUSTRY CANADA This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. ii Safety Instructions Please read these instructions carefully BEFORE INSTALLING and using the HTE-01 Thermostat. Keep this guide in a safe place for future reference. • Installation and repairs are to be performed by a qualified contractor in strict accordance with the requirements of state and local regulating agencies. In the absence of local requirements, follow ANSI/NFPA 70, National Electric Code. • The HTE-01 Thermostat may be used with a 24 VAC power source or battery power only. DO NOT APPLY supply voltage above 30 VAC. • DO NOT expose the HTE-01 Thermostat to voltage fluctuations of more than ±2.4 VAC (±10% of nominal power rating). • DO NOT install the HTE-01 Thermostat in a bathroom or area of excessive moisture. • DO NOT expose the HTE-01 Thermostat or HTM-01 Base Module to water. • DO NOT store the HTE-01/HTM-01 where temperatures drop below -20°F (-4°C) or exceed 122°F (60°C). • DO NOT operate the HTE-01/HTM-01 in temperatures below 32°F (0°C) or above 113°F (45°C). • DO NOT use solvents or aggressive cleaning agents to clean these devices. A dry, soft cloth is recommended. iii iii About This Manual This manual uses special attention icons to alert the reader of important safety concerns, information important to reliable operation of the controls or helpful installation/setup information. Safety: Indicates a condition which may cause severe personal injury, death, or major property damage. Important Information: Indicates information which requires special attention for correct operation of the control. Your Benefit: Indicates helpful installation or setup information. For operating instructions, refer to the Operation Manual. For programming instructions, refer to the Programming Guide. Documentation iv Habitat Technologies 330 East 38th Street, Suite 530 New York, NY 10016-0444 Customer Service Toll Free: 1-800-717-1682 Web Site: www.habitattechnologies.com [email protected] Manual Table of Contents FCC/Industry Canada Certifications i Safety Instructions ii About This Manual iii What’s in the Box 1 Device Overview 2 System Dip Switch Configuration 3 HTM-01 Base Module Installation 4-6 LED Status Indication 7 HTE-01 Thermostat Installation 8 Power Installation 9 Boot Screen Display 10 Device Pairing 11-12 Home Screen 13-14 Appendix A - Wiring Diagrams 15-19 Appendix B - Warranty Information 20-21 Appendix C - Specifications 22 Designed and Engineered in New York U.S. registered Trademark, Patents pending Copyright 2020, All Rights Reserved. Thermostat HTE-01 Module HTM-01 1 What’s In The Box BEFORE BEGINNING installation, confirm that all parts are present in the package: HTE-01 Thermostat with Mounting Plate (2) AA Alkaline Batteries HTM-01 Base Module Wiring Harness (2) Mounting Screws (2) Wall Anchors HTM-01 Base Module with Double-sided Mounting Tape HTM-01 Base Module Water Leak Sensor Cable 2 Device Overview A single Model HTE-01 thermostat can control up to eight air conditioning units equipped with Model HTM-01 base modules. The range between the thermostat and the base modules can be up to approximately 50 feet through standard buildin…
Text truncated - open the document above for the full version.
Differences Declaration To whom concern, We company Habitat Technologies LLC. hereby declares: The product models SAUPTT1, HTE-01 are identical in the same PCB layout, interior structure and electrical circuits. The only differenceis model name for commercial purpose. Authorized signature: Date: 2019-10-31
Habitat Technologies LLC. Letter of Authorization Company: Habitat Technologies LLC. Address: 330 East 38th Street, Suite 530, New York 10016, United States Product Name: PTAC Thermostat Model Number(s): SAUPTT1, HTE-01 Product Description: PTAC Thermostat We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: 2019/10/31 Name: Clifton Botelho Title: Chief Development Officer Company: Habitat Technologies LLC.
< Habitat Technologies LLC. > Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD21046 Date: 10-31-2019 Subject; Request for Long Term Confidentiality FCC ID: 2AUYL-HTE01 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Operational Description It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Clifton Botelho Title: Chief Development Officer
Test model number: SAUPTT1
Label location
Model SAUPTT1 RF Frequency: 915MHz AC Power: 18-30V AC Batteries: 3V --- AA x 2 FCC ID: 2AUYL-HTE01 IC: 25666-HTE01 Designed and Engineered in New York U.S. Registered Trademark. Patents pending Made in China Label size: 20.5mm H x 32.5mm W Font: Trebuchet MS 4pt except: 3mm PTAC Thermostat Rating Label Model SAUPTT1 which is 8pt Bold Habitat logo: 12mm W, in color “Dark Blue”: Hex: #143666, Pantone: 7463 C RGB: 20, 54, 102, CMYK: 100, 86, 33, 21 “Leaf Green” Hex: #8fb17e, Pantone:7494C RGB: 143, 177, 126, CMYK: 48, 16, 62, 0 Model HTE-01 RF Frequency: 915MHz AC Power: 18-30V AC Batteries: 3V --- AA x 2 FCC ID: 2AUYL-HTE01 IC: 25666-HTE01 Designed and Engineered in New York U.S. Registered Trademark. Patents pending Made in China Label size: 20.5mm H x 32.5mm W Font: Trebuchet MS 4pt except: Model HTE-01 which is 8pt Bold 3mm PTAC Thermostat Rating Label Habitat logo: 12mm W, in color “Dark Blue”: Hex: #143666, Pantone: 7463 C RGB: 20, 54, 102, CMYK: 100, 86, 33, 21 “L eaf Green” Hex: #8fb17e, Pantone:7494C RGB: 143, 177, 126, CMYK: 48, 16, 62, 0
FCC ID: 2AUYL-HTE01 RF Exposure Evaluation Limits The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b) Limits for Maximum Permissible Exposure (MPE) Frequency range (MHz) Electric field strength (V/m) Magnetic field strength (A/m) Power density (mW/cm 2 ) Averaging time (minutes) (A) Limits for Occupational/Controlled Exposures 0.3–3.0 614 1.63 *(100) 6 3.0–30 1842/f 4.89/f *(900/f 2 ) 6 30–300 61.4 0.163 1.0 6 300–1500 f/300 6 1500–100,000 5 6 (B) Limits for General Population/Uncontrolled Exposure 0.3–1.34 614 1.63 *(100) 30 1.34–30 824/f 2.19/f *(180/f 2 ) 30 30–300 27.5 0.073 0.2 30 300–1500 f/1500 30 1500–100,000 1.0 30 f = frequency in MHz Friis transmission formula: Pd = (Pout*G)/(4*pi*r 2 ) Where Pd = power density in mW/cm 2 , Pout = output power to antenna in mW; G = gain of antenna in linear scale, Pi = 3.1416; R = distance between observation point and center of the radiator in cm Pd id the limit of MPE, 1 mW/cm 2 . If we know the maximum gain of the antenna and the total power input to the antenna, through the calculation, we will know the distance r where the MPE limit is reached. Test Procedure Software provided by client enabled the EUT to transmit and receive data at lowest, middle and highest channel individually. Test Result of RF Exposure Evaluation Test Frequency Output power to antenna (mW) Power Density at R=20cm (mW/cm 2 ) Limit (mW/cm 2 ) Result 915MHz 42.56 0.0085 1.0 PASS Remark: antenna gain=0dBi
Global United Technology Services Co., Ltd. Report No.: GTS201910000136-01 Test Report Applicant: Habitat Technologies LLC. Address of Applicant: 330 East 38th Street, Suite 530, New York 10016, United States Manufacturer/Factory: COMPUTIME ELECTRONICS (SHENZHEN) CO., LTD. Address of Manufacturer/Factory: Computime Technology Pk, Dan Zhu Tou Cun Buji, Longgang Region Shenzhen China Equipment Under Test (EUT) Product Name: PTAC Thermostat Model No.: SAUPTT1, HTE-01 Trade Mark: Habitat FCC ID: 2AUYL-HTE01 IC: 25666-HTE01 Applicable standards: FCC CFR Title 47 Part 15 Subpart C Section 15.247 RSS-247 Issue 2: February 2017 RSS-Gen Issue 5: March 2019 Date of sample receipt: October 25, 2019 Date of Test: October 25-31, 2019 Date of report issued: October 31, 2019 Test Result : PASS * * In the configuration tested, the EUT complied with the standards specified above. Authorized Signature: Robinson Lo Laboratory Manager This results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Page 1 of 28 Report No.: GTS201910000136-01 2 Version Version No. Date Description 00 October 31, 2019 Original Prepared By: Date: October 31, 2019 Project Engineer Check By: Date: October 31, 2019 Reviewer Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 2 of 28 Report No.: GTS201910000136-01 3 Contents Page 1 COVER PAGE ........................................................................................................................................... 1 2 VERSION .................................................................................................................................................. 2 3 CONTENTS .............................................................................................................................................. 3 4 TEST SUMMARY ..................................................................................................................................... 4 4.1 MEASUREMENT UNCERTAINTY ............................................................................................................ 4 5 GENERAL INFORMATION ...................................................................................................................... 5 5.1 GENERAL DESCRIPTION OF EUT ......................................................................................................... 5 5.2 TEST MODE ........................................................................................................................................ 6 5.3 DESCRIPTION OF SUPPORT UNITS ....................................................................................................... 6 5.4 DEVIATION FROM STANDARDS ............................................................................................................. 6 5.5 ABNORMALITIES FROM STANDARD CONDITIONS ................................................................................... 6 5.6 TEST FACILITY .................................................................................................................................... 6 5.7 TEST LOCATION ................................................................................................................................. 6 5.8 ADDITIONAL INSTRUCTIONS ................................................................................................................. 6 6 TEST INSTRUMENTS LIST ..................................................................................................................... 7 7 TEST RESULTS AND MEASUREMENT DATA ...................................................................................... 9 7.1 ANTENNA REQUIREMENT ..................................................................................................................... 9 7.2 CONDUCTED EMISSIONS ................................................................................................................... 10 7.3 CONDUCTED OUTPUT POWER ........................................................................................................... 13 7.4 CHANNEL BANDWIDTH & 99% OCCUPY BANDWIDTH .......................................................................... 14 7.5 POWER SPECTRAL DENSITY ............................................................................................................. 16 7.6 BAND EDGES .................................................................................................................................... 17 7.6.1 Conducted Emission Method ..................................................................................................... 17 7.7 SPURIOUS EMISSION ......................................................................................................................... 18 7.7.1 Conducted Emission Method ..................................................................................................... 18 7.7.2 Radiated Emission Method ........................................................................................................ 20 7.8 FREQUENCY STABILITY ..................................................................................................................... 26 8 TEST SETUP PHOTO ............................................................................................................................ 28 9 EUT CONSTRUCTIONAL DETAILS ..................................................................................................... 28 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial …
Text truncated - open the document above for the full version.
Test model number: SAUPTT1 Radiated Emission Conducted Emission
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 915 MHz - 915 MHz | 42.56 mW |