FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Yisuma Network Technology Co ., LTD/
  3. 2AUZP-S10C

2AUZP-S10CEasySMX S10 Lite Wireless Controller

Shenzhen Yisuma Network Technology Co ., LTD
EasySMX S10 Lite Wireless Controller - FCC ID 2AUZP-S10C - Shenzhen Yisuma Network Technology Co ., LTD
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Mar 06, 2026
Application Purpose
Original Equipment
Equipment Note
EasySMX S10 Lite Wireless Controller
Frequency Range
2402.00000000 - 2480.00000000
Company
Shenzhen Yisuma Network Technology Co ., LTD
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

After-Sales & Support Customer Support & Warrant Warranty: We provide 1-year warranty. If you experience any issues, please contact us for support Returns & Replacements: If your product is defective or damaged, we offer hassle-after-sale service within the warranty period Contact Us For technical support, warranty claims, or general inquiries, reach out to us Manufacturer: Shenzhen Yisuma Network Technology Co., LTD Email: [email protected] Web: www.easysmx.com/pages/contact--us Add: Jiaxiye Square 1155, Minzhi St. 318, Shenzhen, Guangdong, CN FAQs & Troubleshooting Visit our Discord server: Official EasySMX Server for common questions, troubleshooting guides, and software updates FCC Caution. (1)§ 15.19 Labelling requirements. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. § 15.21 Changes or modification warning Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. § 15.105 Information to the user. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. RF warning for Portable device: The device has been evaluated to meet general RF exposure requirement. The devi ce can be used in portable exposure condition without restriction. According to §15.247(e)(i) and §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines.

Attestation Statements

Covered Equipment Attestation Letter For Certification Service in the USA Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name 2AUZP-S10C S10C We, Applicant Company Name: Shenzhen Yisuma Network Technology Co., LTD Address: Room 808, Minde Building, Xiangnan 3rdZone, Minqiang Community, Minzhi Street, Longhua District, ShenZhen, China Phone: +86-769-8100 0449 certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. This includes the cybersecurity and anti-virus software produced or provided by Kaspersky Lab, Inc. or any of ist successors and assignees. We certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2026-03-05 Signature Date Name / Title: Bin Ou / Manager Company: Shenzhen Yisuma Network Technology Co., LTD Address: Room 808, Minde Building, Xiangnan 3rdZone, Minqiang Community, Minzhi Street, Longhua District, ShenZhen, China Phone: +86-769-8100 0449 Fax: N/A E-Mail: [email protected]

Attestation Statements

Due Diligence Letter For Certification Service in the USA Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern FCC ID Model name 2AUZP-S10C S10C Pursuant to KDB 986446 D01 Covered Equipment Guidance the evaluation of the product above shows compliance for the following reasons: Compliance Evaluation process Results Inherent compliance The chipset(s) used is not capable of running the cybersecurity and/or anti- virus software Compliance The memory used does not allow the running the cybersecurity and/or anti- virus software Compliance The storage capacity does not allow the running the cybersecurity and/or anti-virus software Compliance The operating system used is not capable of running the cybersecurity and/or anti-virus software Compliance No inherent compliance Based on software bill of material Based on scan for running software on the device Based on filesystem scan for cybersecurity and/or anti-virus software The equipment for which authorization is sought complies with the rules and fulfils the requirements as detailed in the above mentioned KDB. Evaluation performed by Company Name: MAXLAB Testing Co., Ltd. Contact Name: Harry Chen Address: 1/F, Building B, Xinshidai GR Park,Shiyan Street, Bao'an District, Shenzhen,Guangdong, 518052, People’s Republic of China Phone: +86-15691418608 Email: [email protected] Signature: Date: 2026-02-27

Cover Letter(s)

Confidentiality Request Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the documentation of the following products: FCC ID Model name 2AUZP-S10C S10C For the products listed above, we request permanent confidentiality for all applicable exhibits as there are: • the Operational Description • the Block Diagram • the Schematics • the Part List • the Tune up Information The above listed exhibits contain trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2026-03-05 Signature Date Name / Title: Bin Ou / Manager Company: Shenzhen Yisuma Network Technology Co., LTD Address: Room 808, Minde Building, Xiangnan 3rdZone, Minqiang Community, Minzhi Street, Longhua District, ShenZhen, China Phone: +86-769-8100 0449 Fax: N/A E-Mail: [email protected]

External Photos

Page1of7 MAXLABTestingCo.,Ltd. ReferencetotheappendixIIfordetails. EUTPHOTO(ExternalPhotos) FCC ID 2AUZP-S10C Page 2 of 7 MAXL AB Testi ng Co.,Ltd . Page 3 of 7 MAXL AB Testi ng Co.,Ltd . Page 4 of 7 MAXL AB Testi ng Co.,Ltd .

ID Label/Location Info

FCCIDLABELINGANDLOCATION FCCIDLabel FCCIDLabelLocation Thelabelshownshallbepermanentlyaffixedataconspicuouslocationonthedeviceandbe readilyvisibletotheuseratthetimepurchase(Labelingrequirementsper2.925) EasySMXS10LiteWirelessController FCCID:2AUZP-S10C

Internal Photos

Page5of7 MAXLABTestingCo.,Ltd. EUTPHOTO(InternalPhotos) FCC ID 2AUZP-S10C Page 6 of 7 MAXL AB Testi ng Co.,Ltd . Page 7 of 7 MAXL AB Testi ng Co.,Ltd . PCB antenna

RF Exposure Info

MAXLAB Testing Co.,Ltd.Report No.: MAX26022711-P01R01RF RF TEST REPORT Report Reference No........................:MAX26022711-P01R01RF FCC ID.................................................:2AUZP-S10C Compiled by ( position+printed name+signature)..: Engineer/ Cindy Zheng Supervised by ( position+printed name+signature)..: Manager/Haley Wen Approved by ( position+printed name+signature)..: RF Manager/ Vivian Jiang Date of issue.........................................:February 27, 2026 Testing Laboratory Name................: MAXLAB Testing Co.,Ltd. Address ................................................. : 1/F, Building B, Xinshidai GR Park,Shiyan Street, Bao'an District, Shenzhen,Guangdong, 518052, People’s Republic of China Applicant’s name...............................: Shenzhen Yisuma Network Technology Co ., LTD Address ................................................. : Room 808, Minde Building, Xiangnan 3rd Zone, Minqiang Community,Minzhi Street,Longhua District, ShenZhen, China Test specification .............................. : Standard................................................:KDB 447498 D01 General RF Exposure Guidance v06 MAXLAB Testing Co.,Ltd.All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the MAXLAB Testing Co.,Ltd. is acknowledged as copyright owner and source of the material. MAXLAB Testing Co.,Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Equipment description.....................: EasySMX S10 Lite Wireless Controller Trade Mark............................................: N/A Manufacturer.........................................:Shenzhen Yisuma Network Technology Co ., LTD Model/Type reference ......................... :S10C Listed Models......................................: N/A Modulation...........................................:GFSK Frequency .............................................. From 2402MHz to 2480MHz Ratings ................................................... :DC 3.7V from battery or DC 5.0V from USB Port Result.....................................................:PASS MAXLAB Testing Co.,Ltd.Report No.: MAX26022711-P01R01RF RF EXPOSURE EVALUATION METHOD According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency(RF) Radiation as specified in §1.1307(b) According to KDB 447498 D01 General RF Exposure Guidance v06, Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition(s), listed below, is (are) satisfied. EUT Specification Frequency band (Operating)WLAN: 2.412GHz ~ 2.462GHz WLAN: 5.150GHz ~ 5.250GHz WLAN: 5.725GHz ~ 5.850GHz Others BT :2402-2480MHz Device categoryPortable (<20cm separation) Mobile (>20cm separation) Others Exposure classificationOccupational/Controlled exposure (S = 5mW/cm 2 ) General Population/Uncontrolled exposure (S=1mW/cm 2 ) Antenna diversitySingle antenna Multiple antennas Tx diversity Rx diversity Tx/Rx diversity Max. output power 6.89dBm (0.00489W) Antenna gain (Max)2.63 dBi Evaluation appliedMPE Evaluation SAR Evaluation MAXLAB Testing Co.,Ltd.Report No.: MAX26022711-P01R01RF RF EXPOSURE EVALUATION METHOD SAR Test Exclusion Thresholds for 100 MHz – 6 GHz and ≤ 50 mm Approximate SAR Test Exclusion Power Thresholds at Selected Frequencies and Test Separation Distances are illustrated in the following Table. The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances≤50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)]·[√f(GHz)]≤3.0 for 1-g SAR and≤7.5 for 10-g extremity SAR,where f(GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation The result is rounded to one decimal place for comparison The test exclusions are applicable only when the minimum test separation distance is≤50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. MAXLAB Testing Co.,Ltd.Report No.: MAX26022711-P01R01RF Maximum measured transmitter power. BLE Operating Mode Frequency Measure d Power max. power Antenna Gain min. test separation distance ResultLimit (MHz)(dBm)(mW)(dBi)(mm) GFSK 24023.582.282.6350.70683 24405.413.482.6351.08573 24806.894.892.6351.53913 The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,mm)] · [√f(GHz)] The test Result is less than 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR. Conclusion: No SAR is required.

Test Report

紾 — l ,泗打胃式匀需习黔陨 ANNEX D EUT PHOTO Antenna J>hoto & Length (mm) 14 / 14

Test Report

Page 1 of31 MAXLABTestingCo.,Ltd. ReportNo.:MAX26022711-P01R01 FCCPART15SUBPARTCTESTREPORT FCCPART15.247 ReportReferenceNo........................:MAX26022711-P01R01 FCCID. ................................................ :2AUZP-S10C Compiledby (position+printedname+signature)..: Engineer/CindyZheng Supervisedby (position+printedname+signature) .. : Manager/HaleyWen Approvedby (position+printedname+signature)..: RFManager/VivianJiang Dateofissue ......................................... :February27,2026 TestingLaboratoryName ................ : MAXLABTestingCo.,Ltd. Address ................................................. : 1/F,BuildingB,XinshidaiGRPark,ShiyanStreet,Bao'anDistrict, Shenzhen,Guangdong,518052,People’sRepublicofChina Applicant’sname ............................... : ShenzhenYisumaNetworkTechnologyCo.,LTD Address.................................................: Room808,MindeBuilding,Xiangnan3rdZone,Minqiang Community,MinzhiStreet,LonghuaDistrict,ShenZhen,China Testspecification..............................: Standard................................................: FCCPart15.247 ANSIC63.10:2020 MAXLABTestingCo.,Ltd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe MAXLABTestingCo.,Ltd.isacknowledgedascopyrightownerandsourceofthematerial.MAXLAB TestingCo.,Ltd.takesnoresponsibilityforandwillnotassumeliabilityfordamagesresultingfromthe reader'sinterpretationofthereproducedmaterialduetoitsplacementandcontext. Equipmentdescription.....................: EasySMXS10LiteWirelessController TradeMark............................................: N/A Manufacturer.........................................:ShenzhenYisumaNetworkTechnologyCo.,LTD Model/Typereference ......................... :S10C ListedModels......................................: N/A Modulation ........................................... :GFSK Frequency..............................................From2402MHzto2480MHz Ratings...................................................:DC3.7VfrombatteryorDC5.0VfromUSBPort Result ..................................................... :PASS MAXLABTestingCo.,Ltd.ReportNo.:MAX26022711-P01R01 Page 2 of31 TESTREPORT EquipmentunderTest:EasySMXS10LiteWirelessController Model/Type:S10C ListedModels:N/A ModelDeclaration:N/A Applicant : ShenzhenYisumaNetworkTechnologyCo.,LTD Address: Room808,MindeBuilding,Xiangnan3rdZone,Minqiang Community,MinzhiStreet,LonghuaDistrict,ShenZhen,China Manufacturer : ShenzhenYisumaNetworkTechnologyCo.,LTD Address: Room808,MindeBuilding,Xiangnan3rdZone,Minqiang Community,MinzhiStreet,LonghuaDistrict,ShenZhen,China TestResult:PASS Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetest laboratory. MAXLABTestingCo.,Ltd.ReportNo.:MAX26022711-P01R01 Page 3 of31 Contents 1TESTSTANDARDS ........................................................................................................................................... 4 2SUMMARY ................................................................................................................................................................ 5 2.1GeneralRemarks.........................................................................................................................................................5 2.2ProductDescription...................................................................................................................................................5 2.3EquipmentUnderTest...............................................................................................................................................5 2.4ShortdescriptionoftheEquipmentunderTest(EUT) ..................................................................................... 5 2.5EUToperationmode ................................................................................................................................................... 6 2.6BlockDiagramofTestSetup ................................................................................................................................... 6 2.7RelatedSubmittal(s)/Grant(s)...............................................................................................................................6 2.8Modifications..............................................................................................................................................................6 3TESTENVIRONMENT.....................................................................................................................................7 3.1Addressofthetestlaboratory ................................................................................................................................. 7 3.2TestFacility ................................................................................................................................................................... 7 3.3Environmentalconditions ......................................................................................................................................... 7 3.4Summaryofmeasurementresults.........................................................................................................................8 3.5Statementofthemeasurementuncertainty........................................................................................................8 3.6EquipmentsUsedduringtheTest..........................................................................................................................9 4TESTCONDITIONSANDRESULTS ................................................................................................ 11 4.1ACPowerConductedEmission ............................................................................................................................ 11 4.2RadiatedEmissionsandBandEdge ....................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Page 1 of 2 MAXLAB Testing Co.,Ltd. Reference to the appendix I for details. EUT TEST PHOTO FCC ID 2AUZP-S10C Page 2 of 2 MAXLAB Testing Co.,Ltd.

Contact Information

Applicant

Ou Bin(Engineer)
[email protected]Fax: 769 - 8107 6135

Technical Contact

Oasis Compliance, Inc.James He
[email protected]

3313 Verdi Dr, San Jose, · California, 95111 · United States

Test Firm

MAXLAB Testing Co., Ltd.Bill Zhao
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz4.90 mW
Confidentiality
Long Term
Grant Notes
Power listed is maximum peak conducted output power. This filing meets the SAR threshold exclusion set forth in KDB 447498 and therefore can be used in mobile/portable configurations. The antenna used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Shenzhen Yisuma Network Technology Co ., LTD

EasySMX Game Controller - FCC ID 2AUZP-D15 - Shenzhen Yisuma Network Technology Co ., LTD
2AUZP-D15

EasySMX Game Controller

Apr 30, 2026

Equipment Class

DTS - Digital Transmission System
EasySMK M15 mobile game controller - FCC ID 2AUZP-M15 - Shenzhen Yisuma Network Technology Co ., LTD
2AUZP-M15

EasySMK M15 mobile game controller

Aug 20, 2024

Equipment Class

DTS - Digital Transmission System
EasySMX 8236 gamepad - FCC ID 2AUZP-8236 - Shenzhen Yisuma Network Technology Co ., LTD
2AUZP-8236

EasySMX 8236 gamepad

Dec 18, 2022

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Wireless earphone - FCC ID 2AUZPEHP-61D - Shenzhen Yisuma Network Technology Co ., LTD
2AUZPEHP-61D

Wireless earphone

Sep 26, 2022

Equipment Class

DTS - Digital Transmission System
wireless 2.4Ghz gaming headset - FCC ID 2AUZP-V07W - Shenzhen Yisuma Network Technology Co ., LTD
2AUZP-V07W

wireless 2.4Ghz gaming headset

Jul 14, 2020

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter