FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Apex Biotechnology Corp./
  3. 2AV24-BGM039

2AV24-BGM039BGM039 Link Blood Glucose Monitoring System

Apex Biotechnology Corp.

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 08, 2024
Application Purpose
Original Equipment
Date of Application
Jul 07, 2024
Equipment Note
BGM039 Link Blood Glucose Monitoring System
Frequency Range
2402.00000000 - 2480.00000000
Company
Apex Biotechnology Corp.
Country
Taiwan

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

ID Label/Location Info

BGM039 Link 59106001077 Blood Glucose Monitoring Syst em BGM039 Link P/N 59106001077 Rev.1/22 S70463 S70464 Manufactured by APEX BIOTECHNOLOGY CORP. No. 7, Li-Hsin Rd. V, Hsinchu Science Park, Hsinchu, Taiwan, R.O.C. Tel:1-877-979-5454 (Monday through Friday from 8am to 5pm EST) E-mail:[email protected] For In Vitro Diagnostic Use GTIN: (01)XXXXXXXXXXXXX SN: (21)XX00001 FCC ID: 2AV24-BGM039 Label location FCC ID:2AV24-BGM039

RF Exposure Info

Report No.: FA3D0601 Page : 1 of 6 Report Version: Rev. 01 FCC RF Exposure Report FCC ID : 2AV24-BGM039 Equipment : BGM039 Link Blood Glucose Monitoring System Model No. : BGM039 Brand Name : ApexBio Applicant : Apex Biotechnology Corp. Address : No. 7, Li-Hsin Rd. V, Hsinchu Science Park, Hsinchu, Taiwan, R.O.C. Standard : 47 CFR FCC Part 2.1093 Received Date : Dec. 06, 2023 Tested Date : Mar. 14 ~ Mar. 18, 2024 We, International Certification Corporation, would like to declare that the tested sample has been evaluated and in compliance with the requirement of the above standards. The test results contained in this report refer exclusively to the product. It shall not be reproduced except in full without the written approval of our laboratory. Reviewed by: Approved by: Along Chen / Assistant Manager Gary Chang / Manager Report No.: FA3D0601 Page : 2 of 6 Report Version: Rev. 01 Table of Contents 1 RF EXPOSURE TEST EXEMPTIONS ................................................................................................... 4 1.1 1-mW TEST EXEMPTION ..................................................................................................................... 4 1.2 SAR-BASED EXEMPTION .................................................................................................................... 4 1.3 MPE-BASED EXEMPTION .................................................................................................................... 4 1.4 REFERENCE GUIDANCE ..................................................................................................................... 5 1.5 DEVIATION FROM TEST STANDARD AND MEASUREMENT PROCEDURE ................................... 5 1.7 EXEMPTION CALCULATION ................................................................................................................ 5 2 TEST LABORATORY INFORMATION ................................................................................................. 6 Report No.: FA3D0601 Page : 3 of 6 Report Version: Rev. 01 Release Record Report No. Version Description Issued Date FA3D0601 Rev. 01 Initial issue May 02, 2024 Report No.: FA3D0601 Page : 4 of 6 Report Version: Rev. 01 1 RF Exposure Test Exemptions 1.1 1-mW TEST EXEMPTION Available maximum time-averaged power is no more than 1 mW. 1.2 SAR-BASED EXEMPTION This exemption is applicable to the frequency range between 300 MHz and 6 GHz, with test separation distances between 0.5 cm and 40 cm, and for all RF sources in fixed, mobile, and portable device exposure conditions. The maximum time-averaged power or effective radiated power (ERP), whichever is greater, ≤ Pth Pth (mW) = ERP 20cm (d/20) x d≤20cm Pth (mW) = ERP 20cm 20 cm < d ≤40cm Where = - log 10 Pth (mW) = ERP 20cm (mW) = 2040f 0.3GHz ≤ f < 1.5 GHz Pth (mW) = ERP 20cm (mW) = 3060 1.5GHz ≤ f < 6 GHz Power Thresholds (mW) Frequency (MHz) Distance (mm) 5 10 15 20 25 30 35 40 45 50 300 39 65 88 110 129 148 166 184 201 217 450 22 44 67 89 112 135 158 180 203 226 835 9 25 44 66 90 116 145 175 207 240 1900 3 12 26 44 66 92 122 157 195 236 2450 3 10 22 38 59 83 111 143 179 219 3600 2 8 18 32 49 71 96 125 158 195 5800 1 6 14 25 40 58 80 106 136 169 1.3 MPE-BASED EXEMPTION For a much wider frequency range, from 300 kHz to 100 GHz, applicable for separation distances greater or equal to λ/2π, where λ is the free-space operating wavelength in meters. Radio Source Frequency Minimum Distance Threshold ERP F L MHz F H MHz λ L / 2π λ H / 2π W 0.3 - 1.34 159 m - 35.6 m 1920 R 2 1.34 - 30 35.6 m - 1.6 m 3450 R 2 /f 2 30 - 300 1.6 m - 159 mm 3.83 R 2 300 - 1500 159 mm - 31.8 mm 0.0128 R 2 f 1500 - 100000 31.8 mm - 0.5 mm 19.2 R 2 Note: R is the antenna-person separation distance. Report No.: FA3D0601 Page : 5 of 6 Report Version: Rev. 01 1.4 REFERENCE GUIDANCE 447498 D04 Interim General RF Exposure Guidance v01 1.5 DEVIATION FROM TEST STANDARD AND MEASUREMENT PROCEDURE None 1.6 MEASUREMENT UNCERTAINTY The measurement uncertainties given below are based on a 95% confidence level (based on a coverage factor (k=2)). Parameters Uncertainty Conducted power ±0.808 dB Declaration of Conformity: The test results with all measurement uncertainty excluded are presented in accordance with the regulation limits or requirements declared by manufacturers. Comments and Explanations: The declared of product specification for EUT presented in the report are provided by the manufacturer, and the manufacturer takes all the responsibilities for the accuracy of product specification. 1.7 EXEMPTION CALCULATION Frequency Range (MHz) Maximum Conducted Power (dBm) Maximum Tune Up Limit Antenna Gain (dBi) EIRP (dBm) ERP (dBm) SAR-Based Exemption Thresholds (mW) Pass/ Fail (dBm) (mW) (dBm) (mW) 2402 ~ 2480 -5.87 -4 0.398 -7.09 -11.09 -13.24 0.047 3 Pass Report No.: FA3D0601 Page : 6 of 6 Report Version: Rev. 01 2 Test laboratory information Established in 2012, ICC provides foremost EMC & RF Testing and advisory consultation services by our skilled engineers and technicians. Our services employ a wide variety of advanced edge test equipment and one of the widest certification extents in the business. International Certification Corporation (EMC and Wireless Communication Laboratory), it is our definitive objective is to institute long term, trust-based associations with our clients. The expectation we set up with our clients is based on outstanding service, practical expertise and devotion to a certified value structure. Our passion is to grant our clients with best EMC / RF services by oriented knowledgeable and accommodating staff. Our Test sites are located at Linkou District and Kwei Shan District. Location map can be found on our website http://www.icertifi.com.tw. Linkou Kwei Shan Kwei Shan Site II Tel: 886-2-2601-1640 Tel: 886-3-271-8666 Tel: 886-3-271-8640 No.30-2, Ding Fwu Tsuen, Lin Kou District, New Taipei City, Taiwan (R.O.C.) No.3-1, Lane 6, Wen San 3rd St., Kwei Shan Dist., Tao Yuan City 33381, Taiwan (R.O.C.) No.2-1, La…

Text truncated - open the document above for the full version.

Test Report

Report No.: AP3D0601 Page : 1 of 8 Report Version: Rev. 02 The previous version of the test report has been cancelled and replaced by new version. Antenna Pattern Report Equipment : PCB antennam Model No. : APEX_BGM039 onboard PCB ANT Brand : ApexBio Applicant : Apex Biotechnology Corp. Address : No. 7, Li-Hsin Rd. V, Hsinchu Science Park, Hsinchu, Taiwan, R.O.C. Received Date : Jan. 02, 2024 Tested Date : Jan. 19, 2024 We, International Certification Corporation, would like to declare that the tested sample has been evaluated and in compliance with the requirement of the above standards. The test results contained in this report refer exclusively to the product. It may be duplicated completely for legal use with the approval of the applicant. It shall not be reproduced except in full without the written approval of our laboratory. Approved & Reviewed by: Gary Chang / Manager Ty: XXX Report No.: AP3D0601 Page : 2 of 8 Report Version: Rev. 02 The previous version of the test report has been cancelled and replaced by new version. Table of Contents 1 GENERAL DESCRIPTION .................................................................................................................... 4 1.1 Information.............................................................................................................................................. 4 1.2 The Equipment List ................................................................................................................................ 4 1.3 Measurement Uncertainty ...................................................................................................................... 4 1.4 Reference Standard ............................................................................................................................... 4 2 TEST CONFIGURATION ....................................................................................................................... 5 2.1 Testing Facility ....................................................................................................................................... 5 2.2 Testing Condition and Location Information ........................................................................................... 5 2.3 Test Modes and Frequency Details ....................................................................................................... 5 3 TEST RESULTS .................................................................................................................................... 6 3.1 Test Procedures ..................................................................................................................................... 6 3.2 Test Setup .............................................................................................................................................. 6 3.3 Test Results............................................................................................................................................ 7 4 TEST LABORATORY INFORMATION ................................................................................................. 8 Report No.: AP3D0601 Page : 3 of 8 Report Version: Rev. 02 The previous version of the test report has been cancelled and replaced by new version. Release Record Report No. Version Description Issued Date AP3D0601 Rev. 01 Initial issue Apr. 30, 2024 AP3D0601 Rev. 02 Remove test setup and internal photo Jun. 18, 2024 Report No.: AP3D0601 Page : 4 of 8 Report Version: Rev. 02 The previous version of the test report has been cancelled and replaced by new version. 1 General Description 1.1 Information Brand Model Product name Type / Connector ApexBio APEX_BGM039 onboard PCB ANT PCB antenna PCB / NA 1.2 The Equipment List Test Item Radiated Emissions Test Site Fully-anechoic chamber 1 / (05CH01-WS) Test Date Jan. 19, 2024 Instrument Manufacturer Model No. Serial No. Calibration Date Calibration Until Spectrum Analyzer Agilent N9010A MY52221474 Nov. 14, 2023 Nov. 13, 2024 Horn Antenna 1G-18G SCHWARZBECK BBHA 9120 D 9120D-1205 Feb. 03, 2023 Feb. 02, 2024 Preamplifier Agilent 83017A MY53270013 Feb. 04, 2023 Feb. 03, 2024 Preamplifier EMC EMC02325 980188 Jan. 02, 2024 Jan. 01, 2025 RF Cable-1M EMC EMC104-35M-35M-1000 S/N:210926 Oct. 11, 2023 Oct. 10, 2024 RF Cable-1M EMC EMC104-35M-35M-1000 S/N:210927 Oct. 11, 2023 Oct. 10, 2024 RF cable-3M HUBER+SUHNER SUCOFLEX104 MY22621/4 Oct. 11, 2023 Oct. 10, 2024 RF cable-4M HUBER+SUHNER SUCOFLEX104 MY32489/4 Oct. 11, 2023 Oct. 10, 2024 LF cable-0.8M EMC EMC8D-NM-NM-800 EMC8D-NM-NM-800-002 Oct. 11, 2023 Oct. 10, 2024 LF cable-3M EMC EMC8D-NM-NM-3000 131102 Oct. 11, 2023 Oct. 10, 2024 LF cable-10M EMC EMC8D-NM-NM-10000 131101 Oct. 11, 2023 Oct. 10, 2024 Measurement Software AUDIX e3 6.120210g NA NA Note: Calibration Interval of instruments listed above is one year. 1.3 Measurement Uncertainty The measurement uncertainties given below are based on a 95% confidence level (based on a coverage factor (k=2)). Measurement Uncertainty Parameters Uncertainty Antenna gain ±2.787 dB 1.4 Reference Standard FCC KDB 412172 D01 Report No.: AP3D0601 Page : 5 of 8 Report Version: Rev. 02 The previous version of the test report has been cancelled and replaced by new version. 2 Test Configuration 2.1 Testing Facility Test Laboratory International Certification Corporation Test Site 05CH01-WS Address of Test Site No.14-1, Lane 19, Wen San 3rd St., Kwei Shan Dist., Tao Yuan City 33381, Taiwan (R.O.C.) 2.2 Testing Condition and Location Information Test Item Test Site Ambient Condition Tested By Antenna Pattern 05CH01-WS 22°C / 69% Hugo Zheng 2.3 Test Modes and Frequency Details Test item Test Frequency (GHz) Antenna Pattern 2.402 / 2.44 / 2.48 Report No.: AP3D0601 Page : 6 of 8 Report Version: Rev. 02 The previous version of the test report has been cancelled and replaced by new version. 3 Test Results 3.1 Test Procedures 1. c Use a calibrated antenna to get reference value.Put t…

Text truncated - open the document above for the full version.

Test Report

Report No.: FR3D0601AE Page : 1 of 17 Report Version: Rev. 01 FCC Test Report FCC ID : 2AV24-BGM039 Equipment : BGM039 Link Blood Glucose Monitoring System Model No. : BGM039 Brand Name : ApexBio Applicant : Apex Biotechnology Corp. Address : No. 7, Li-Hsin Rd. V, Hsinchu Science Park, Hsinchu, Taiwan, R.O.C. Standard : 47 CFR FCC Part 15.247 Received Date : Dec. 06, 2023 Tested Date : Mar. 14 ~ Mar. 18, 2024 We, International Certification Corporation, would like to declare that the tested sample has been evaluated and in compliance with the requirement of the above standards. The test results contained in this report refer exclusively to the product. It shall not be reproduced except in full without the written approval of our laboratory. Reviewed by: Approved by: Along Chen / Assistant Manager Gary Chang / Manager Report No.: FR3D0601AE Page : 2 of 17 Report Version: Rev. 01 Table of Contents 1 GENERAL DESCRIPTION .................................................................................................................... 5 1.1 Information.............................................................................................................................................. 5 1.2 Local Support Equipment List ................................................................................................................ 7 1.3 Test Setup Chart .................................................................................................................................... 7 1.4 Test Equipment List and Calibration Data .............................................................................................. 8 1.5 Test Standards ....................................................................................................................................... 9 1.6 Reference Guidance .............................................................................................................................. 9 1.7 Deviation from Test Standard and Measurement Procedure ................................................................. 9 1.8 Measurement Uncertainty ...................................................................................................................... 9 2 TEST CONFIGURATION ..................................................................................................................... 10 2.1 Testing Facility ..................................................................................................................................... 10 2.2 The Worst Test Modes and Channel Details ....................................................................................... 10 3 TRANSMITTER TEST RESULTS ....................................................................................................... 11 3.1 6dB and Occupied Bandwidth .............................................................................................................. 11 3.2 Conducted Output Power ..................................................................................................................... 12 3.3 Power Spectral Density ........................................................................................................................ 13 3.4 Unwanted Emissions in Restricted Frequency Bands ......................................................................... 14 3.5 Emissions in non-restricted Frequency Bands ..................................................................................... 16 4 TEST LABORATORY INFORMATION ............................................................................................... 17 Appendix A. 6dB and Occupied Bandwidth Appendix B. Conducted Output Power Appendix C. Power Spectral Density Appendix D. Unwanted Emissions into Restricted Frequency Bands Appendix E. Emissions in Non-Restricted Frequency Bands Report No.: FR3D0601AE Page : 3 of 17 Report Version: Rev. 01 Release Record Report No. Version Description Issued Date FR3D0601AE Rev. 01 Initial issue May 02, 2024 Report No.: FR3D0601AE Page : 4 of 17 Report Version: Rev. 01 Summary of Test Results FCC Rules Test Items Measured Result 15.207 AC Power Line Conducted Emissions Note 1 N/A 15.247(d) 15.209 Unwanted Emissions [dBuV/m at 3m]: 12400.00MHz 52.99 (Margin -1.01dB) - AV Pass 15.247(b)(3) Conducted Output Power Power [dBm]: -5.28 Pass 15.247(a)(2) 6dB Bandwidth Meet the requirement of limit Pass 15.247(e) Power Spectral Density Meet the requirement of limit Pass 15.203 Antenna Requirement Meet the requirement of limit Pass N/A means Not Applicable. Note 1 : The EUT consumes DC power from battery, so the test is not required Declaration of Conformity: The test results with all measurement uncertainty excluded are presented in accordance with the regulation limits or requirements declared by manufacturers. Comments and Explanations: The declared of product specification for EUT presented in the report are provided by the manufacturer, and the manufacturer takes all the responsibilities for the accuracy of product specification. Report No.: FR3D0601AE Page : 5 of 17 Report Version: Rev. 01 1 General Description 1.1 Information 1.1.1 Specification of the Equipment under Test (EUT) RF General Information Frequency Range (MHz) Bluetooth Mode Ch. Freq. (MHz) Channel Number Data Rate 2400-2483.5 LE 2402-2480 0-39 [40] 1 Mbps 2 Mbps Note: Bluetooth LE (Low energy) uses GFSK modulation. 1.1.2 Antenna Details Ant. No. Brand Model Type Connector Gain (dBi) 1 ApexBio APEX_BGM039 onboard PCB ANT PCB antenna No -7.09 1.1.3 Power Supply Type of Equipment under Test (EUT) Power Supply Type 6Vdc from batteries (3Vdc x2) 1.1.4 Accessories Accessories No. Equipment Description 1 Battery(x2) Brand: TOSHIBA Model: CR2032 Rating: 3Vdc Report No.: FR3D0601AE Page : 6 of 17 Report Version: Rev. 01 1.1.5 Channel List Frequency band (MHz) 2400~2483.5 Channel Frequency (MHz) Channel Frequency (MHz) Channel Frequency (MHz) Channel Frequency (MHz) 37 2402 …

Text truncated - open the document above for the full version.

Contact Information

Applicant

Shane Chu(R&D Instrument Section Leader)
[email protected]886-3-5641952Fax: 886-3-5678302

Test Firm

International Certification Corp.Fu-Cheng Chuang
[email protected]886-3-271-8666Fax: 886-3-318-0155

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz300.00 µW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. This device meets the SAR test exemption threshold listed in KDB 447498 and is authorized for portable operation.

Other Applications from Apex Biotechnology Corp.

GlucoSure Link Blood Glucose Monitoring System - FCC ID 2AV24BGM024 - Apex Biotechnology Corp.
2AV24BGM024

GlucoSure Link Blood Glucose Monitoring System

May 19, 2021

Equipment Class

DTS - Digital Transmission System
MultiSure GK Link Blood Glucose and Ketone Monitoring System - FCC ID 2AV24MTM309 - Apex Biotechnology Corp.
2AV24MTM309

MultiSure GK Link Blood Glucose and Ketone Monitoring System

Apr 15, 2020

Equipment Class

DTS - Digital Transmission System