1 Input: •Micro-USB •5 Volt •min. 0.8 A Output: •5 Volt •≤ 1A Patent pending Design patents pending ROHS compliant ← 6 cm→ ← 30cm → ← 2 in → ← 12in → 1 mm 0.04 inch Sensitive surfaces / Empfindliche Oberflächen / Eurfaces ensibles Superficies sensibles / Superfici sensibili Removable / Wiederablösbar / Rachetable / Rescatable / Riscattabile IoT Changes or modifications not expressly approved by the manufacturer could void the user‘s authority to operate the equipment. During operation, a distance of at least 20 cm must be maintained between the charging coil and the operator / bystander. FCC ID: 2AV3O-V-JUICE1 www.V-Juice.xyz –V-Juice –Emil-Geis-Strasse 33 –81379 Munich –Germany –www.V-Juice.xyz V-Juice Model 1.0 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The LED indicate different working modes and functions. On power-up with no Qi device placed on the charger, the green and red indicators blink three times. Once a charging device, like a phone is placed on the pad, a blinking green indicates the ongoing charging process. Once the charging is completed, the green indicator stays on. A blinking red indicator might show an error or the charging device is not correctly or centered placed on the charging pad/coil. www.V-Juice.xyz –V-Juice –Emil-Geis-Strasse 33 –81379 Munich –Germany –www.V-Juice.xyz V-Juice Model 1.0
U2 32.768 kHz
STC Germany GmbH Ohmstrasse 1 84160 Frontenhausen 2020-Sep-29 Long/Short-term Confidentiality Request FCC ID: 2AV3O-V-JUICE1 To Whom It May Concerns, Pursuant to sections 0.457(d) and 0.459 of CFR 47 and to avoid premature release of sensitive information prior to marketing or release of the product to the public, we hereby request long- term confidential treatment of information accompanying this application as outlined below: ☒ Schematics ☒ Parts List ☐ Block Diagram ☐ Tune-Up Info ☐ Operational Description In addition, we hereby request the following exhibits contained in this application to be temporarily (short-term confidentiality) withheld from the public disclosure ☐ for an initial period of days ☐ until: ☒ not applicable ☐ External Photos ☐ Test Setup Photos ☐ Internal Photos ☐ Users Manual The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to rule 0.457(d), disclosure of this application and all accompanying documentation will not be made before the date of the GRANT for this application. If you have any questions, please feel free to contact me. Yours sincerely, Tropmann Anton Authorised Agent Head of Laboratory STC Germany (formerly PKM electronic GmbH) DerMissingLink - V-Juice Tilman Röder Emil-Geis-Straße 33 81379 München Germany Tel.: +49 172 1083212 [email protected] VAT-ID: DE815646780
Attachment to Test-Report-No.: 20/04-0002 Product: Battery Charger STC Germany GmbH, Ohmstrasse 1, 84160 Frontenhausen Tel.: + 49 (0) 8732 6381 - Fax: + 49 (0) 8732 2345 - E-mail: [email protected] - Website: www.pkm.eu.com o:\funk\20-04-0002\20-04-0002-fcc-ext-photos.docx page 1 of 3 Photos of tested sample Attachment to Test-Report-No.: 20/04-0002 Product: Battery Charger STC Germany GmbH, Ohmstrasse 1, 84160 Frontenhausen Tel.: + 49 (0) 8732 6381 - Fax: + 49 (0) 8732 2345 - E-mail: [email protected] - Website: www.pkm.eu.com o:\funk\20-04-0002\20-04-0002-fcc-ext-photos.docx page 2 of 3 Attachment to Test-Report-No.: 20/04-0002 Product: Battery Charger STC Germany GmbH, Ohmstrasse 1, 84160 Frontenhausen Tel.: + 49 (0) 8732 6381 - Fax: + 49 (0) 8732 2345 - E-mail: [email protected] - Website: www.pkm.eu.com o:\funk\20-04-0002\20-04-0002-fcc-ext-photos.docx page 3 of 3
Label Location Info FCC ID: 2AV3O-V-JUICE1 FCC ID of the Devices is located on the bottom side of the housing. FCC ID: 2AV3O-V-JUICE1
Attachment to Test-Report-No.: 20/04-0002 Product: Battery Charger STC Germany GmbH, Ohmstrasse 1, 84160 Frontenhausen Tel.: + 49 (0) 8732 6381 - Fax: + 49 (0) 8732 2345 - E-mail: [email protected] - Website: www.pkm.eu.com o:\funk\20-04-0002\20-04-0002-fcc-int-photos.docx page 1 of 2 Photos of tested sample Attachment to Test-Report-No.: 20/04-0002 Product: Battery Charger STC Germany GmbH, Ohmstrasse 1, 84160 Frontenhausen Tel.: + 49 (0) 8732 6381 - Fax: + 49 (0) 8732 2345 - E-mail: [email protected] - Website: www.pkm.eu.com o:\funk\20-04-0002\20-04-0002-fcc-int-photos.docx page 2 of 2
Description of Operation for Wireless Charger V-Juice FCC ID: 2AV3O-V-JUICE1 The device is an inductive charger for mobile devices like Smartphones, based on the QI technology. It uses electromagnetic induction to provide electricity to portable devices. Energy is transferred through inductive coupling. An alternating current is run through an induction coil in the charging pad. This makes an alternating electric current in the induction coil embedded in the portable device. The operating frequency range is 110 kHz - 205 kHz (depending on the load and load position). The device is able to detect foreign objects like keys or other metallic parts that have been placed on the transmitter coil. In case of a detected foreign object, the transmitter reduces its power or switches its magnetic field completely off.
Test report according to ISO/IEC 17025:2017 FCC (Federal Communications Commission) Test Firm Registration Number: 768032 Designation Number DE0022 RF Exposure e-CFR Title 47 Chapter I Subchapter A §1.1310 FCC KDB 680106 D01 RF Exposure Wireless Charging App v03 STC Germany GmbH Ohmstrasse 1 84160 Frontenhausen, Germany Tel.: + 49 (0) 8732 6381 Fax: + 49 (0) 8732 2345 E-mail: [email protected] Test report no.: 20/04-0002 Page 1 of 14 pages Test report no.: 20/04-0002 Page 2 of 14 pages Table of contents 1. Client information ................................................................................................................................................... 3 2. Equipment under test (EUT) ................................................................................................................................... 3 3. Description of the Equipment under test and test conditions .................................................................................. 4 4. Performed measurements and results.................................................................................................................... 5 5. RF Exposure .......................................................................................................................................................... 6 6. Test equipment ....................................................................................................................................................... 9 7. Test Setups .......................................................................................................................................................... 10 8. Measurement uncertainthy ................................................................................................................................... 11 9. Photos setup ........................................................................................................................................................ 12 10. Conclusions .......................................................................................................................................................... 13 11. Photos of tested samble ....................................................................................................................................... 14 Location of test facility: STC Germany GmbH Ohmstrasse 1 84160 Frontenhausen Germany Test report no.: 20/04-0002 Page 3 of 14 pages 1. Client information Name: V-Juice Address: Emil-Geis-Straße 33 Name of contact: Tilman Roeder Telephone: +49 172 1083212 Fax: -/- E-mail: E-Mail: [email protected] 2. Equipment under test (EUT) 2.1 Identification of the EUT Equipment: Inductive Charger Model: 1.0 Brand name: V-Juice Serial no.: -/- Manufacturer: V-Juice Country of origin: Germany Power rating: 5 V ⎓ ; min 0.8 A Highest frequency generated or used in the device or on which the device operates or tunes: 205 kHz Date Sample Received: 03.04.2020 Tests were performed: 15.06.2020 2.2 Additional information about the EUT: -/- To duplicate parts of this test report needs the written confirmation of the test laboratory. The test results relate only to the above mentioned test sample(s). Test report no.: 20/04-0002 Page 4 of 14 pages 3. Description of the Equipment under test and test conditions FCC-ID: 2AV3O-V-JUICE1 Cables: -/- Approx. Size (l x w x h): (41.5 x 6.0 x 1.0) cm Test conditions: The “Inductive Charger - 1.0” (=equipment under test – EUT) had been tested, with a host AC-Adaptor and an input voltage of 120 V / 60 Hz in the following modes: 1. EUT active – Output: with artificial max. load 500mA; direct contacted 2. EUT active – Output: with artificial max. load 500mA; with distance (2mm) contacted 3. EUT active – Output: with normal load (Battery Pack); direct contacted 4. EUT active – Output: with normal load (Battery Pack); with distance (2mm) contacted The tested configuration represents (based on the product specification) with the tested operation modes the worst case. Additional information: -/- Operating frequencies: 110 kHz – 205 kHz Max. field strength of fundamental: QP 71.3 dBμV/m @ 3m Spurious Emissions: (radiated lowest margin to limit) QP 38.6 dBμV/m (1.4 dB) @ 3m Environmental conditions during tests: Ambient temperature: 20 °C Relative humitity 42 % Atmospheric pressure 955 mbar Antenna Transmitter: Model: Type: External (coil) fixed Internal Test report no.: 20/04-0002 Page 5 of 14 pages 4. Performed measurements and results The complete list of measurements required in e-CFR Title 47 Chapter I Subchapter A Part 1, § 1.1310 is given below. Standard: Test Method: Test requirements: applicable: fulfilled: Yes No Yes No § 1.1310 KDB 680106 RF Exposure All required / applicable tests according to the following standards were performed under Ref-No. 20/04-0002. - e-CFR Title 47 Chapter I Subchapter A Part 1 Subpart I, § 1.1310 - e-CFR data is current as of August 12, 2020 Remark: -/- Test report no.: 20/04-0002 Page 6 of 14 pages 5. RF Exposure Applied standards - e-CFR Title 47 Chapter I Subchapter A Part 1 Subpart I, § 1.1310 - FCC KDB 680106 D01 RF Exposure Wireless Charging Apps v03 Section 5 b) Requirement Inductive wireless power transfer applications with supporting field strength results and meeting all of the following requirements are not required to submit a KDB inquiry for devices approved using SDoC or a PAG for equipment approved using certification to address RF exposure compliance. However, the responsible party is required to keep a copy of the test report in accordance with KDB 865664 D02. A copy of the test report is to be submitted with the application if the device is approved using certification. 1) Power transfer frequency is less than 1 MHz. 2) Output power from each primary coil is less than or equal to 15 watts. 3) The transfer system includes only single primary and secondary coils. This includes charging systems that may have multiple primary coils and …
Text truncated - open the document above for the full version.
Test report according to ISO/IEC 17025:2017 FCC (Federal Communications Commission) Test Firm Registration Number: 768032 Designation Number DE0022 Electromagnetic compatibility Intentional Radiators STC Germany GmbH Ohmstrasse 1 84160 Frontenhausen, Germany Tel.: + 49 (0) 8732 6381 Fax: + 49 (0) 8732 2345 E-mail: [email protected] Test report no.: 20/04-0002 Page 1 of 65 pages Test report no.: 20/04-0002 Page 2 of 65 pages Table of contents 1. Client information ................................................................................................................................................... 3 2. Equipment under test (EUT) ................................................................................................................................... 3 3. Description of the Equipment under test and test conditions .................................................................................. 4 4. Performed measurements and results.................................................................................................................... 5 5. AC Mains conducted emissions ............................................................................................................................. 6 6. Radiated emission measurements ....................................................................................................................... 24 7. Fundamental Emission ......................................................................................................................................... 55 8. Test equipment ..................................................................................................................................................... 57 9. Test Setups .......................................................................................................................................................... 59 10. Measurement uncertainthy ................................................................................................................................... 62 11. Photos setup ........................................................................................................................................................ 63 12. Conclusions .......................................................................................................................................................... 64 13. Photos of tested sample ....................................................................................................................................... 65 Location of test facility: STC Germany GmbH Ohmstrasse 1 84160 Frontenhausen Germany Test report no.: 20/04-0002 Page 3 of 65 pages 1. Client information Name: V-Juice Address: Emil-Geis-Straße 33 Name of contact: Tilman Roeder Telephone: +49 172 1083212 Fax: -/- E-mail: E-Mail: [email protected] 2. Equipment under test (EUT) 2.1 Identification of the EUT Equipment: Inductive Charger Model: 1.0 Brand name: V-Juice Serial no.: -/- Manufacturer: V-Juice Country of origin: Germany Power rating: 5 V ⎓ ; min 0.8 A Highest frequency generated or used in the device or on which the device operates or tunes: 205 kHz Date Sample Received: 03.04.2020 Tests were performed: 29.05.2020 – 12.10.2020 2.2 Additional information about the EUT: -/- To duplicate parts of this test report needs the written confirmation of the test laboratory. The test results relate only to the above mentioned test sample(s). Test report no.: 20/04-0002 Page 4 of 65 pages 3. Description of the Equipment under test and test conditions FCC-ID: 2AV3O-V-JUICE1 Cables: -/- Approx. Size (l x w x h): (41.5 x 6.0 x 1.0) cm Test conditions: The “Inductive Charger - 1.0” (=equipment under test – EUT) had been tested, with a host AC-Adaptor and an input voltage of 120 V / 60 Hz in the following modes: 1. EUT active – Output: with artificial max. load 500mA; direct contacted 2. EUT active – Output: with artificial max. load 500mA; with distance (2mm) contacted 3. EUT active – Output: with normal load (Battery Pack); direct contacted 4. EUT active – Output: with normal load (Battery Pack); with distance (2mm) contacted The tested configuration represents (based on the product specification) with the tested operation modes the worst case. Additional information: -/- Operating frequencies: 110 kHz – 205 kHz Max. field strength of fundamental: AV 68.18 dBμV/m @ 3m Spurious Emissions: (radiated lowest margin to limit) QP 38.6 dBμV/m (1.4 dB) @ 3m Environmental conditions during tests: Ambient temperature: 20 °C Relative humitity 42 % Atmospheric pressure 955 mbar Antenna Transmitter: Model: Type: External (coil) fixed Internal Test report no.: 20/04-0002 Page 5 of 65 pages 4. Performed measurements and results The complete list of measurements required in e-CFR Title 47 Chapter I Subchapter A Part 15 Subpart C is given below. Standard: Test Method: Test requirements: applicable: fulfilled: Yes No Yes No § 15.207 ANSI 63.10 Section 6.2 AC Mains Conducted Emissions § 15.209 ANSI 63.10 Section 6.3 - 6.6 Radiated Emissions All required / applicable tests according to the following standards were performed under Ref-No. 20/04-0002. - e-CFR Title 47 Chapter I Subchapter A Part 15 Subpart C with test Method according to ANSI C63.10-2013 - e-CFR data is current as of August 12, 2020 Remark: -/- Test report no.: 20/04-0002 Page 6 of 65 pages 5. AC Mains conducted emissions Applied standards -e-CFR Title 47 Chapter I Subchapter A Part 15 Subpart C, § 15.207 Conducted limits Test site Measurements of conducted emission from EUT was made in the shielded chamber (DC - 10GHz) located in the test facility. Test equipment and test set up Test equipment used for conducted measurements on Mains as given in clause Test equipment of this report. Test setup used for conducted measurements on Mains as given in clause Test setups of this report. Detector function selection and bandwidth In conducted emissions measurement CISPR…
Text truncated - open the document above for the full version.
Attachment to Test-Report-No.: 20/04-0002 Product: Battery Charger STC Germany GmbH, Ohmstrasse 1, 84160 Frontenhausen Tel.: + 49 (0) 8732 6381 - Fax: + 49 (0) 8732 2345 - E-mail: [email protected] - Website: www.pkm.eu.com o:\funk\20-04-0002\20-04-0002-fcc-rep-photos test setup.docx page 1 of 6 Photos Test Setup Test configuration Conducted Mains emissions coil EUT Battery pack Artifical load USB detector Ancillary AC adaptor Attachment to Test-Report-No.: 20/04-0002 Product: Battery Charger STC Germany GmbH, Ohmstrasse 1, 84160 Frontenhausen Tel.: + 49 (0) 8732 6381 - Fax: + 49 (0) 8732 2345 - E-mail: [email protected] - Website: www.pkm.eu.com o:\funk\20-04-0002\20-04-0002-fcc-rep-photos test setup.docx page 2 of 6 Attachment to Test-Report-No.: 20/04-0002 Product: Battery Charger STC Germany GmbH, Ohmstrasse 1, 84160 Frontenhausen Tel.: + 49 (0) 8732 6381 - Fax: + 49 (0) 8732 2345 - E-mail: [email protected] - Website: www.pkm.eu.com o:\funk\20-04-0002\20-04-0002-fcc-rep-photos test setup.docx page 3 of 6 Radiated emissions Tested frequency range 9 kHz – 30 MHz Attachment to Test-Report-No.: 20/04-0002 Product: Battery Charger STC Germany GmbH, Ohmstrasse 1, 84160 Frontenhausen Tel.: + 49 (0) 8732 6381 - Fax: + 49 (0) 8732 2345 - E-mail: [email protected] - Website: www.pkm.eu.com o:\funk\20-04-0002\20-04-0002-fcc-rep-photos test setup.docx page 4 of 6 Tested frequency range 30 MHz - 1000 MHz Attachment to Test-Report-No.: 20/04-0002 Product: Battery Charger STC Germany GmbH, Ohmstrasse 1, 84160 Frontenhausen Tel.: + 49 (0) 8732 6381 - Fax: + 49 (0) 8732 2345 - E-mail: [email protected] - Website: www.pkm.eu.com o:\funk\20-04-0002\20-04-0002-fcc-rep-photos test setup.docx page 5 of 6 Attachment to Test-Report-No.: 20/04-0002 Product: Battery Charger STC Germany GmbH, Ohmstrasse 1, 84160 Frontenhausen Tel.: + 49 (0) 8732 6381 - Fax: + 49 (0) 8732 2345 - E-mail: [email protected] - Website: www.pkm.eu.com o:\funk\20-04-0002\20-04-0002-fcc-rep-photos test setup.docx page 6 of 6 RF-Exposure measurement
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.11 MHz - 0.205 MHz | - |