FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Geotab Inc./
  3. 2AV57GATBA1

2AV57GATBA1Asset Tracker

Geotab Inc.

Application Details

Equipment Class
PCB - PCS Licensed Transmitter
Date of Grant
May 28, 2026
Application Purpose
Original Equipment
Equipment Note
Asset Tracker
Frequency Range
698.20000000 - 715.80000000
Company
Geotab Inc.
Country
Canada

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗
↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Test Report

www.nemko.com Nemko Canada Inc., a testing laboratory, is accredited by ANSI National Accreditation Board (ANAB). The tests included in this report are within the scope of this accreditation. The ANAB symbol is an official symbol of the ANSI National Accreditation Board, used under licence. ANAB File Number: AT-3195 (Ottawa); AT-3193 (Pointe-Claire); AT-3194 (Cambridge) C h o o s e S c a n d i n a v i a n t r u s t RADIO TEST REPORT Report ID Project ID REP151724 PRJ0097083 Type of assessment: Modular transmitter integration Applicant: Geotab Inc. Product: Model: Asset Tracker GATBA1 FCC ID: ISED Certification number: FCC ID: 2AV57GATBA1 IC: 11140A-GATBA1 Specifications:  FCC 47 CFR Part 24, Subpart E  FCC 47 CFR Part 27, Subpart C  RSS-130 Issue 2, February 2019  RSS-133 Issue 7, July 2024 Date of issue: May 25, 2026 Dishant Champaneri, EMC/RF Specialist Tested by Signature Jagrut Vaishnav, EMC/RF Specialist Reviewed by Signature Dhara Patel, EMC/RF Specialist Reviewed by Signature Report reference ID: REP151724 Page 2 of 14 Lab and test locations Company name Nemko Canada Inc. Facilities Ottawa site: 303 River Road, Ottawa, ON, Canada, K1V 1H2 Tel: +1 613 737 9680 Test site registration number: CA2040 Montréal site: 292 Labrosse Avenue, Pointe-Claire, QC, Canada, H9R 5L8 Tel: +1 514 694 2684 Test site registration number: CA2041 Cambridge site: 1-130 Saltsman Drive, Cambridge, ON, Canada, N3E 0B2 Tel: +1 519 650 4811 Test site registration number: CA0101 Website www.nemko.com Limits of responsibility Note that the results contained in this report relate only to the items tested and were obtained in the period between the date of initial receipt of samples and the date of issue of the report. This test report has been completed in accordance with the requirements of ISO/IEC 17025. All results contained in this report are within Nemko Canada’s ISO/IEC 17025 accreditation. Copyright notification Nemko Canada Inc. authorizes the applicant to reproduce this report provided it is reproduced in its entirety and for use by the company’s employees only. Any use which a third party makes of this report, or any reliance on or decisions to be made based on it, are the responsibility of such third parties. Nemko Canada Inc. accepts no responsibility for damages, if any, suffered by any third party as a result of decisions made or actions based on this report. © Nemko Canada Inc. Report reference ID: REP151724 Page 3 of 14 Table of Contents Table of Contents ......................................................................................................................................................................................................... 3 Report summary ................................................................................................................................................................................. 4 1.1 Test specifications .................................................................................................................................................................................................... 4 1.2 Test methods ............................................................................................................................................................................................................ 4 1.3 Exclusions ................................................................................................................................................................................................................. 4 1.4 Statement of compliance .......................................................................................................................................................................................... 4 1.5 Test report revision history ....................................................................................................................................................................................... 4 Engineering considerations ................................................................................................................................................................. 5 2.1 Modifications incorporated in the EUT for compliance ............................................................................................................................................ 5 2.2 Technical judgment .................................................................................................................................................................................................. 5 2.3 Model variant declaration ........................................................................................................................................................................................ 5 2.4 Deviations from laboratory tests procedures ........................................................................................................................................................... 5 Test conditions ................................................................................................................................................................................... 6 3.1 Atmospheric conditions ............................................................................................................................................................................................ 6 3.2 Power supply range .................................................................................................................................................................................................. 6 Information provided by the applicant ................................................................................................................................................ 7 4.1 Disclaimer ..............................................................................................................................…

Text truncated - open the document above for the full version.

Test Report

www.nemko.com Nemko Canada Inc., a testing laboratory, is accredited by ANSI National Accreditation Board (ANAB). The tests included in this report are within the scope of this accreditation. The ANAB symbol is an official symbol of the ANSI National Accreditation Board, used under licence. ANAB File Number: AT-3195 (Ottawa); AT-3193 (Pointe-Claire); AT-3194 (Cambridge) RSS-130, RSS-132, RSS-133, RSS-139; Date: Sep 16, 2025 Choose Scandinavian trust RADIO TEST REPORT Report ID: Project number: REP166767 PRJ0100103 Type of assessment: Final product testing, Partial assessment Applicant: Geotab Inc. Product marketing name (PMN): HVIN(s): GO Anywhere GATBA1 ISED certification number: Contains ISED module number: 11140A-GATBA1 4441A-DLSAWI13WW Specifications: • RSS-130, Issue 2, February 2019 • RSS-132, Issue 4, January 2023 • RSS-133, Issue 7, July 2024 • RSS-139, Issue 4, October 2022 • FCC 47 CFR Part 24, Subpart E • FCC 47 CFR Part 27, Subpart C Date of issue: May 26, 2026 Dishant Champaneri, EMC/RF Engineer Tested by Signature Inas Bahadori, EMC/RF Specialist Tested by Signature Andrey Adelberg, Senior RF/EMC Specialist Reviewed by Signature Report reference ID: REP166767 Page 2 of 19 Lab locations Company name Nemko Canada Inc. Facilities Ottawa site: 303 River Road, Ottawa, ON, Canada, K1V 1H2 Tel: +1 613 737 9680 Test site registration number: CA2040 Montréal site: 292 Labrosse Avenue, Pointe-Claire, QC, Canada, H9R 5L8 Tel: +1 514 694 2684 Test site registration number: CA2041 Cambridge site: 1-130 Saltsman Drive, Cambridge, ON, Canada, N3E 0B2 Tel: +1 519 650 4811 Test site registration number: CA0101 Website www.nemko.com Limits of responsibility Note that the results contained in this report relate only to the items tested and were obtained in the period between the date of initial receipt of samples and the date of issue of the report. This test report has been completed in accordance with the requirements of ISO/IEC 17025. All results contained in this report are within Nemko Canada’s ISO/IEC 17025 accreditation. Copyright notification Nemko Canada Inc. authorizes the applicant to reproduce this report provided it is reproduced in its entirety and for use by the company’s employees only. Any use which a third party makes of this report, or any reliance on or decisions to be made based on it, are the responsibility of such third parties. Nemko Canada Inc. accepts no responsibility for damages, if any, suffered by any third party as a result of decisions made or actions based on this report. © Nemko Canada Inc. Report reference ID: REP166767 Page 3 of 19 Table of Contents Table of Contents ......................................................................................................................................................................................................... 3 Report summary ................................................................................................................................................................................. 4 1.1 Test specifications .................................................................................................................................................................................................... 4 1.2 Test methods ............................................................................................................................................................................................................ 4 1.3 Exclusions ................................................................................................................................................................................................................. 4 1.4 Statement of compliance .......................................................................................................................................................................................... 4 1.5 Test report revision history ....................................................................................................................................................................................... 4 Engineering considerations ................................................................................................................................................................. 5 2.1 Modifications incorporated in the EUT for compliance ............................................................................................................................................ 5 2.2 Technical judgment .................................................................................................................................................................................................. 5 2.3 Model variant declaration ........................................................................................................................................................................................ 5 2.4 Deviations from laboratory tests procedures ........................................................................................................................................................... 5 Test conditions ................................................................................................................................................................................... 6 3.1 Atmospheric conditions ............................................................................................................................................................................................ 6 3.2 Power supply range .................................................................................................................................................................................................. 6 Information provided by the applicant ..........................................................................................................................................…

Text truncated - open the document above for the full version.

Attestation Statements

Dated: March 12, 2026 Nemko North America, Inc. 303 River Road Ottawa ON K1V 1H2 Canada Covered Equipment Certification Attestation Letter Applicant: Geotab Inc. FCC ID: 2AV57GATBA1 The applicant certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section §2.903 of the FCC rules. This includes certifying that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Note: If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current FCC Covered List, the applicant should include an explanation on why the equipment is not “covered” equipment. The applicant certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, Signature: Name: Benjamin Jull Title: Manager, Product Certification Company: Geotab Inc. Address: 2440 Winston Park Drive, Oakville, Ontario, L6H 7V2, Canada Phone: +1 (877) 436-8221 Email: [email protected]

RF Exposure Info

www.nemko.com Nemko Canada Inc., a testing laboratory, is accredited by ANSI National Accreditation Board (ANAB). The test results included in this report are within the scope of this accreditation. The ANAB symbol is an official symbol of the ANSI National Accreditation Board, used under licence. FCC and ISED RSS-102– MPE Calculation; Date: January 2026 RF Exposure Compliance – MPE Calculation Report C h o o s e S c a n d i n a v i a n t r u s t Applicant company: Geotab Inc. Model number (HVIN): GATBA1 Model name (PMN): GATBA1 FCC Identification: FCC ID: 2AV57GATBA1 ISED certification number: IC: 11140A-GATBA1 Product type: Mobile Device Device category Consumer Device for General Population/Uncontrolled Exposure Date of issue: April 16, 2026 Compliance Specifications: FCC 47 CFR Part 1 Subpart I, §§1.1307, 1.1310 FCC 47 CFR Part 2 Subpart J, §§2.1091, 2.1093 FCC KDB 447498 D01 General RF Exposure Guidance v06 FCC KDB 865664 D01 RF Exposure Procedures and Equipment Authorization Policies ISED Canada RSS-102 Issue 6 December 15, 2023 MPE calculation report Product info: FCC ID: 2AV57GATBA1 IC: 11140A-GATBA1 Model: GATBA1 Page 2 of 8 Test locations of Nemko Canada Inc. Ottawa site Montréal site GTA Cambridge site Facility address 303 River Road Ottawa, Ontario Canada K1V 1H2 Tel: +1 613 737 9680 Fax: +1 613 737 9691 292 Labrosse Avenue Pointe-Claire, Québec Canada H9R 5L8 Tel: +1 514 694 2684 Fax: +1 514 694 3528 1-130 Saltsman Drive Cambridge, Ontario Canada N3E 0B2 Tel: +1 519 650 4811 Test site identifier - FCC CA2040 CA2041 CA0101 Test site identifier – ISED Canada 2040A-4 2040G-5 24676 ANAB File Number AT-3195 AT-3193 AT-3194 Andrey Adelberg Senior EMC/Wireless Specialist Prepared by Signature Limits of responsibility The results presented in this report apply solely to the specific device model tested and are valid only for the operating conditions and installation requirements specified herein. Testing was conducted in accordance with ISO/IEC 17025:2017 requirements, and all results fall within the scope of Nemko Canada's accreditation. This MPE evaluation is based on the maximum power levels and operating conditions specified. Any modifications to the device hardware, software, or installation that could affect RF output power or antenna characteristics may invalidate this compliance demonstration. Copyright notification This report may be reproduced by the applicant in its entirety for regulatory submission and internal use. Any use of this report by third parties, including reliance on its contents or decisions made based on it, is solely at the risk of those third parties. Nemko Canada Inc. assumes no responsibility for any damages incurred by third parties as a result of actions taken based on this report. © Nemko Canada Inc. All rights reserved. MPE calculation report Product info: FCC ID: 2AV57GATBA1 IC: 11140A-GATBA1 Model: GATBA1 Page 3 of 8 1. Executive Summary This report presents the Maximum Permissible Exposure (MPE) analysis to demonstrate compliance with FCC and ISED RF exposure requirements. The evaluation considers both single transmitter operation and simultaneous multi-transmitter scenarios where applicable. 2. Key Findings Compliance status Complies Critical separation distances 20 cm Special conditions or limitations N/A MPE calculation report Product info: FCC ID: 2AV57GATBA1 IC: 11140A-GATBA1 Model: GATBA1 Page 4 of 8 MPE calculations for stand-alone transmission Device Classification Requirements Portable Device Definition (§2.1093) Devices designed for use by a person where the radiating structure is within 20 cm of the user's body require SAR evaluation rather than MPE calculation. Mobile Device Definition Devices installed in vehicles or with permanently installed antennas may use MPE calculations if minimum separation distances can be established. Fixed/Base Station Definition Stationary transmitters with controlled access to antenna locations may use MPE calculations for both occupational and general population exposure scenarios. 3. References, definitions and limits for FCC FCC §2.1091(d) (2) For operations within the frequency range of 300 kHz and 6 GHz (inclusive), the limits for maximum permissible exposure (MPE), derived from whole-body SAR limits and listed in Table 1 in paragraph (e)(1) of this section, may be used instead of whole-body SAR limits as set forth in paragraphs (a) through (c) of this section to evaluate the environmental impact of human exposure to RF radiation as specified in §1.1307(b) of this part, except for portable devices as defined in §2.1093 of this chapter as these evaluations shall be performed according to the SAR provisions in §2.1093. Table 1: §1.1310(e)(1)—Power Density Limits for Maximum Permissible Exposure (MPE) Frequency range (MHz) Power density (mW/cm 2 ) Averaging time (minutes) (i) Limits for Occupational/Controlled Exposure 0.3–3.0 *(100) ≤6 3.0–30 *(900 / f 2 ) <6 30–300 1.0 <6 300–1500 f / 300 <6 1500–100000 5 <6 (ii) Limits for General Population/Uncontrolled Exposure 0.3–1.34 *(100) <30 1.34–30 *(180 / f 2 ) <30 30–300 0.2 <30 300–1500 f / 1500 <30 1500–100000 1.0 <30 Notes: f = frequency in MHz. * = Plane-wave equivalent power density. MPE calculation report Product info: FCC ID: 2AV57GATBA1 IC: 11140A-GATBA1 Model: GATBA1 Page 5 of 8 4. References, definitions and limits for ISED RSS-102 Section 5.3.2 The power density reference levels, and associated reference period for devices employed by the general public (uncontrolled environment) and controlled-use devices (controlled environment) are specified in table below. Note that the power density limits specified in this table apply to whole body exposure conditions. Table 2: RSS-102— Power density limits Frequency range (MHz) Power density (W/m 2 ) Power density (mW/cm 2 ) Reference Period (minutes) Limits for controlled-use devices (controlled environment) 10–20 10 1 6 20–48 44.72 / ƒ 0.5 4.472 / ƒ 0.5 6 48–100 6.455 0.6455 6 100–6000 0.6455 ƒ 0.5 0.0…

Text truncated - open the document above for the full version.

ID Label/Location Info

Label and Label Location Exhibit

Cover Letter(s)

CONFIDENTIALITY AND NON-DISCLOSURE AGREEMENT This Confidentiality and Non-Disclosure Agreement (the "Agreement"), effective as of the date of last signature hereto (the "Effective Date"), is entered into by and between GEOTAB INC., an Ontario corporation, having its principal place of business at 2440 Winston Park Drive, Oakville, Ontario L6H 7V2 Canada (the "Disclosing Party") and the entity identified in the signature blocks at the end of this Agreement (the "Recipient", and together with the Disclosing Party, the "Parties", and each a "Party"). CONTEXT: A. In connection with the facilitation of discussions, negotiations, and potential business collaboration between the Parties (the "Purpose"), the Recipient desires to receive Confidential Information from the Disclosing Party; B. The Disclosing Party desires to disclose such Confidential information to the Recipient, subject to the terms and conditions of this Agreement; and C. The Disclosing Party wishes to protect and preserve the confidentiality of such information. NOW, THEREFORE, in consideration of the mutual covenants, terms and conditions set forth herein, and for other good and valuable consideration, the receipt and sufficiency of which are hereby acknowledged, the Parties agree as follows: 1. Definitions. For purposes of this Agreement, the following terms have the following meanings: (a) "Confidential Information" means all information, data, documents, agreements, files and other materials regarding or concerning the Disclosing Party or its affiliates, whether disclosed orally or disclosed or stored in written, electronic or other form or media, which is disclosed or otherwise furnished by the Disclosing Party or its Representatives before, on or after the date hereof, including all analyses, notes, compilations, reports, forecasts, studies, samples, statistics, summaries, interpretations and other documents prepared by or for the Recipient or its Representatives which contain or otherwise reflect or are generated from such information, data, documents, agreements, files or other materials, whether or not marked, designated or otherwise identified as "confidential". The term "Confidential Information" as used herein shall not include information that: (i) is or becomes generally available to and known by the public (other than as a result of its disclosure directly or indirectly by the Recipient or its Representatives in violation of this Agreement); (ii) is or becomes available to the Recipient from a source other than the Disclosing Party or its Representatives, provided that such source, to the best of the Recipient's knowledge after reasonable inquiry, was not and is not bound by a confidentiality agreement regarding the Disclosing Party or its affiliates, or otherwise prohibited from disclosing such information by a legal, contractual or fiduciary obligation; (iii) was already known by or in the possession of the Recipient as established by documentary evidence, prior to being disclosed by or on behalf of the Disclosing Party pursuant to this Agreement; (iv) has been independently developed by the Recipient as established by documentary evidence, without violating any of its obligations under this agreement/use of or reference to, in whole or in part, the Confidential Information. (b) "Person" means any individual, partnership (whether general, limited or limited liability), corporation, association, trust or other entity. (c) "Personal Information" means information that: (i) relates to an individual person; and (ii) identifies or can be used to identify, locate or contact that individual alone or when combined with other personal or identifying information that is or can be associated with that specific individual. (d) "Representatives" means, as to any Person, such Person's affiliates, and its and their respective directors, officers, employees, general partners, shareholders, agents and consultants (including lawyers, financial advisors and accountants). Other terms not specifically defined in this Section 1 shall have the meanings given to them elsewhere in this Agreement. 2. Recipient's Obligations. The Recipient shall: (a) keep the Confidential Information strictly confidential and protect and safeguard the confidentiality of all such Confidential Information with at least the same degree of care as the Recipient would protect its own 2 Confidential Information, but in no event with less than a commercially reasonable degree of care; (b) not use the Confidential Information, or permit it to be accessed or used, for any purpose other than the Purpose, or otherwise in any manner to the Disclosing Party's detriment, including without limitation, to reverse engineer, disassemble, decompile or design around the Disclosing Party's proprietary services, products and/or confidential intellectual property; (c) without the prior written consent of the Disclosing Party, not disclose or permit its Representatives to disclose any Confidential Information to any Person except: (i) if required by law or regulation, rule or valid court order or pursuant to any requirement, request or process of any legal or, regulatory, supervisory or governmental authority, but only in accordance with Section 5; or (ii) to its Representatives, to the extent necessary to permit such Representatives who need to know the Confidential Information to assist the Recipient in relation to the Purpose and for no other purpose provided, the Recipient shall: (A) inform the Recipient's Representatives of the confidential nature of the Confidential Information; (B) be responsible for any breach of this Agreement by any of its Representatives; (C) use reasonable controls to prevent unauthorized use or disclosure of the Confidential Information (but in any event no less than the degree of care and control that the Recipient uses to protect its own confidential information of similar importance); (D) promptly notify the Disclosing Party of any unauthorized …

Text truncated - open the document above for the full version.

Cover Letter(s)

Geotab Inc. 2440 Winston Park Drive Oakville, Ontario L6H 7V2, Canada March 12, 2026 Nemko North America, Inc. 303 River Road, Ottawa, Ontario, Canada K1V 1H2 Attn: Director of Certification Request for Special Confidentiality – FCC FCC ID: 2AV57GATBA1 Pursuant to FCC 47 CFR 0.457(d)(1)(ii) and 0.459 and FCC guidance published in KDB 726920, we hereby request confidential treatment of information accompanying this application as outlined below. We request the exhibits selected below as long term confidential (LTC) be withheld from public view permanently: Selection of exhibits for LTC (with NDA) 1 Exhibit name ☒ Permanent (Long Term) Internal Photos The circuit board and internal components are inaccessible to users and are serviceable only by designated professional technicians under NDA. All sales of these devices must be subject to an NDA that restricts the disclosure of proprietary information, including internal photographs. Sample NDA is attached with this application. Our company has invested significant resources in developing this innovative product, which is one of the industry's first of its kind. Public disclosure of the subject information could undermine our competitive advantage and lead to financial loss. Protecting the details of our design is essential to safeguarding our intellectual property. The information provided contains trade secrets and proprietary information that is not typically disclosed to the public. Public disclosure of this information could harm the applicant and provide an unfair advantage to competitors. The applicant understands that, pursuant to Rule 0.457 (d)(1)(ii), disclosure of this application and all accompanying materials will not occur before the grant date. Sincerely, Signed by: Benjamin Jull Signature Print name Manager, Product Certification Title +1 (877) 436-8221 Phone 1 - These items require further information to be provided to TCB before permanent confidentiality will be extended to these exhibits. Please refer to FCC KDB 726920 and review section II, 3) regarding specific information (NDA) that must accompany these requests. Geotab Inc. 2440 Winston Park Drive Oakville, Ontario L6H 7V2, Canada Geotab Inc. Company 2440 Winston Park Drive, Oakville, Ontario, L2H 7V2, Canada Address

Cover Letter(s)

Geotab Inc. 2440 Winston Park Drive Oakville, Ontario L6H 7V2, Canada March 12, 2026 Nemko North America, Inc. 303 River Road, Ottawa, Ontario, Canada K1V 1H2 Attn: Director of Certification Request for Confidentiality – FCC FCC ID: 2AV57GATBA1 Pursuant to FCC 47 CFR 0.457(d)(1)(ii) and 0.459 and FCC guidance published in KDB 726920, we hereby request confidential treatment of information accompanying this application as outlined below. We request the exhibits selected below as long term confidential (LTC) be withheld from public view permanently: Selection of exhibits for LTC - general Exhibit name ☒ Permanent (Long Term) Block Diagrams ☒ Permanent (Long Term) Operation Description / Theory of Operation ☒ Permanent (Long Term) Parts List & Placement / BOM ☒ Permanent (Long Term) Schematics Selection of exhibits for LTC - specific 1 Exhibit name ☒ Permanent (Long Term) Tune-Up Procedure We also request the exhibits selected below as short term confidential (STC) be withheld from public view for a period of 180 days 2 from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public: Selection of exhibits for STC 3 Exhibit name ☒ Short Term User’s Manual ☒ Short Term External Photos ☒ Short Term Test Setup Photos Our company has spent a substantial effort in developing this product and it is one of the first of its kind in the industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. When the device is marketed before the requested number of days listed above, the grantee will inform the TCB to release the Short-Term Confidentiality information withheld on the FCC equipment authorization website. 1 - Tune up procedure is applicable only for licensed equipment. 2 - Number of days can be listed up to 180 but should not go past the date of beginning of product marketing/sale. 3 - Any exhibits that may have already been requested to have “Permanent” confidentiality need not be repeated under Short-Term confiden…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Benjamin Jull(Manager, Product Certification)
[email protected]Fax: 1-877-436-8221

Technical Contact

Geotab USA IncBenjamin Jull
[email protected]

6543 S. Las Vegas Blvd Suite 200 · Las Vegas, 89119 · United States

Test Firm

Bureau Veritas CPS (H.K.) Ltd., Taoyuan BranchRichard Chen
[email protected]Fax: +886-3-211-5834

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
124E1.86 GHz - 1.90 GHz250.00 mW1M08G7D0.002688ppm
224E1.86 GHz - 1.90 GHz241.00 mW1M08D7W0.002688ppm
3271.71 GHz - 1.75 GHz237.00 mW1M08D7W0.00292ppm
4271.72 GHz - 1.75 GHz248.00 mW1M08G7D0.002907ppm
522H824.7 MHz - 848.3 MHz218.00 mW1M08D7W0.006063ppm
622H829 MHz - 844 MHz237.00 mW1M08G7D0.006031ppm
727899 MHz - 899 MHz227.00 mW1M09G7D0.005562ppm
827899 MHz - 899 MHz201.00 mW1M10D7W0.005562ppm
927701.5 MHz - 713.5 MHz213.00 mW1M08D7W0.007128ppm
127704 MHz - 711 MHz237.00 mW1M08G7D0.007032ppm
1127782 MHz - 782 MHz232.00 mW1M08G7D0.006394ppm
1227782 MHz - 782 MHz227.00 mW1M08D7W0.006394ppm
1324E1.86 GHz - 1.91 GHz234.00 mW1M08D7W0.002692ppm
1424E1.86 GHz - 1.91 GHz239.00 mW1M08G7D0.002688ppm
1522H831.5 MHz - 841.5 MHz261.00 mW1M08G7D0.006013ppm
1622H831.5 MHz - 841.5 MHz233.00 mW1M08D7W0.006013ppm
179819 MHz - 819 MHz235.00 mW1M08G7D0.006105ppm
189819 MHz - 819 MHz232.00 mW1M08D7W0.006105ppm
19271.72 GHz - 1.77 GHz234.00 mW1M08D7W0.002911ppm
2271.72 GHz - 1.77 GHz239.00 mW1M09G7D0.002907ppm
2127703 MHz - 711 MHz237.00 mW1M08G7D0.005044ppm
2227703 MHz - 711 MHz213.00 mW1M08D7W0.005044ppm
2324E1.85 GHz - 1.91 GHz231.00 mW189KG7D0.002702ppm
24271.71 GHz - 1.75 GHz229.00 mW189KG7D0.002924ppm
2522H824.2 MHz - 848.8 MHz232.00 mW189KG7D0.006066ppm
2627897.7 MHz - 900.3 MHz223.00 mW189KG7D0.00557ppm
2727699.2 MHz - 715.8 MHz234.00 mW188KG7D0.007151ppm
2827777.2 MHz - 786.8 MHz232.00 mW188KG7D0.006433ppm
2927704.2 MHz - 715.8 MHz212.00 mW188KG7D0.0071ppm
324E1.85 GHz - 1.91 GHz229.00 mW189KG7D0.002702ppm
3122H824.2 MHz - 848.8 MHz241.00 mW106KG7D0.006066ppm
3222H824.2 MHz - 848.8 MHz235.00 mW188KG7D0.006066ppm
339814.7 MHz - 823.3 MHz237.00 mW106KG7D0.006141ppm
349814.7 MHz - 823.3 MHz236.00 mW188KG7D0.006141ppm
35271.71 GHz - 1.78 GHz237.00 mW190KG7D0.002924ppm
3627698.2 MHz - 715.8 MHz237.00 mW188KG7D0.006985ppm
Confidentiality
Long Term
Grant Notes
Output power listed is average conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device contains a single LTE-M/NB-IoT transmitter (FCC ID: NKR-DLSAWI13WW). This device supports LTE-M Bands 2/4/5/8/12/13/25/26/66/85 and NB-IoT Bands 2/4/5/8/12/13/25/26/66/85. This device contains functions that are not operational in U.S Territories. This filling is only applicable for US operations.