Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Applicant Declaration QSF27-14-04 Rev 1.4 April 25, 2025 Page 1 of 1 Original Issue: Jan. 4, 2021 SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia 30024 United States Applicant Legal Business Name NIDEC MOBILITY KOREA CORPORATION Address 790-12, Bogaewonsam-ro, Bogae-myeon, Anseong-si, Gyeonggi-do, Korea, 17507 FRN 0029489630 Grantee Code 2AV76 FCC ID: 2AV76-NMOK-370W Authorized Contact Name Sang-il Nam Contact Phone +82-2-850-5789 Contact Email [email protected] I, the undersigned, certify that I am an authorized signatory for the Applicant and therefore declare; a) in accordance with 47CFR2.911(d), all of the statements herein and the exhibits attached hereto are true and correct to the best of my knowledge and belief. b) in accepting a Grant of Equipment Authorization issued by a TCB, under the authority of the FCC, as a result of the representations made in this application, the Applicant is responsible for: (1) labeling the equipment with the exact FCC ID as specified in this application, (2) compliance statement labeling pursuant to the applicable rules, (3) compliance of the equipment with the applicable technical rules, c) if the Applicant is not the actual manufacturer of the equipment, appropriate arrangements have been made with the manufacturer to ensure that production units of this equipment will continue to comply with the FCC’s technical requirements. d) in accordance with 47 CFR 2.909 and KDB394321, the Applicant has read, understood and agrees to accept that they are the responsible party and agree to abide by their responsibilities as specified under 47 CFR 2.909 and KDB394321. e) in accordance with ISO 17065, FCC KDB641163, FCC KDB610077, KDB394321 and RSP-100, the Applicant has read, understood, accepts and agrees to abide by the post market surveillance requirements. (1) the Applicant understands, accepts and agrees that a sample may be requested for surveillance testing. (2) the Applicant shall make provisions to always have a production sample available upon request by SGS, FCC and/or ISED. (3) the Applicant shall, upon request by SGS, at the Applicant’s expense, provide a production sample of the requested product to SGS, FCC and/or ISED as instructed. The sample shall include all support devices, cables, software, accessories or other hardware or software required for evaluation, review, certification and audit surveillance of products certified by SGS. f) neither the Applicant nor any party to the application is subject to a denial of Federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. §862 because of a conviction for possession or distribution of a controlled substance. See 47CFR 1.2002(b) for the definition of a “party” for these purposes. g) the Applicant has read, understood, accepts and agrees to abide by the SGS North America, Inc. terms and conditions as specified in the TCB Application Form 731 (QSF27-14-01). Link to CFRs: https://www.fcc.gov/wireless/bureau-divisions/technologies-systems-and-innovation-division/rules-regulations-title-47 Link to KDBs: https://apps.fcc.gov/oetcf/kdb/index.cfm Link to RSP-100: https://www.ic.gc.ca/eic/site/smt-gst.nsf/eng/sf01130.html Link to the Covered List: Covered List Applicant Signature: Date: JUN 12, 2026 Print Name: Sang-il Nam Title: Senior Manager *NOTE: This declaration cannot be signed by an Agent, it shall be signed by an authorized person listed in the FCC database
FCC COVERED LIST DECLARATION LETTER Page 1 of 1 Revision 1.0 SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia 30024 United States Applicant Legal Business Name NIDEC MOBILITY KOREA CORPORATION Address 790-12, Bogaewonsam-ro, Bogae-myeon, Anseong-si, Gyeonggi-do, Korea, 17507 FRN 0029489630 Grantee Code 2AV76 FCC ID: 2AV76-NMOK-370W Authorized Contact Name Sang-il Nam Contact Phone 82-2-850-5789 Contact Email [email protected] NIDEC MOBILITY KOREA CORPORATION (“the applicant”) certifies: - the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. - as of the date of the filing of the application, the applicant is not identified on the Covered list, established pursuant to §1.50002, as an entity producing “covered” equipment. - the software to be loaded prior to marketing of the equipment identified above is not “covered” software manufactured by any entity including predecessors, successors, parents, subsidiaries, affiliates or any entity which has rebranded or relabeled the software produced by the entity(ies) identified on the “Covered List”. - the device is not capable of storing or running software listed on the covered list and therefore is not inherently compliant. NOTE: Justification/evidence explaining how compliance is met must accompany this letter Link to the Covered List: Covered List Applicant Signature: Date: JUN 12, 2026 Print Name: Sang-il Nam Title: Senior Manager *NOTE: This declaration cannot be signed by an Agent, it shall be signed by an authorized person listed in the FCC database
V01222025 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 United States Date: 06/12/2026 Ref: Attestation Statement Part 2.911(d)(7) Filing FCC ID:2AV76-NMOK-370W NIDEC MOBILITY KOREA CORPORATION certifies that, as of the dates of this application, Americas Compliance Consulting LLC dba iCertifi “iCertifi” is our designated U.S. agent for service of process for the above referenced FCC ID. NIDEC MOBILITY KOREA CORPORATION accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any commission-related proceeding involving the equipment. iCertifi accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service process for the above referenced FCC ID. Designated U.S. Agent Information: Name Americas Compliance consulting, LLC dba iCertifi FCC FRN 0033399411 Address 5809 US-2, Suite B Albeni Plaza Priest River, ID 83856,United States Contact Person Paul Preston Telephone +1-866-885-4575 Email [email protected] Sincerely, NIDEC MOBILITY KOREA CORPORATION Americas Compliance Consulting LLC dba iCertifi 0029489630 0033399411 Sang-il Nam Paul Preston Senior Manager President/CEO Signature Signature
Date: 2026-06-12 TO : Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Regarding: 2AV76-NMOK-370W To whom it may concern: We, the undersigned, hereby authorize SGS KOREA Co., Ltd. to act on our behalf in all manners relating to application for equipment authorization with respect to the FCC ID above, including signing of all documents relating to these matters. Any and all acts carried out by the agent on our behalf shall have the same effect as acts of our own. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). Where our agent signs the application for certification on our behalf, I acknowledge that all r esponsibility for complying with the terms and conditions for Certification, as specified by SGS North America, Inc., s till resides with << NIDEC MOBILITY KOREA CORPORATION>>. This authorization is valid until further written notice from the applicant. N ame (P rinted) :Sang-il Nam T itle:Senior Manager Signature: On behalf of Company: N IDEC MOBILITY KOREA CORPORATION T elephone: +82-2-850-5789
NIDEC MOBILITY KOREA CORPORATION 790-12, Bogaewonsam-ro, Bogae-myeon, Anseong-si, Gyeonggi-do, Republic of Korea Date : JUN 12, 2026 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road, Columbia, MD 21046 REQUEST FOR CONFIDENTIALITY FCC ID: 2AV76-NMOK-370W Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules (CFR 47), and Section 552 (b) (4) of the Freedom of Information Act, NIDEC MOBILITY KOREA CORPORATION hereby requests confidentiality and treatment of certain information accompanying this application. The materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. We are also hereby request Short-Term Confidentiality for 180 days after the grant as outlined in Public Notice DA 04-1705. This provision will give , NIDEC MOBILITY KOREA CORPORATION temporary confidentiality of commercially sensitive information prior to product release. The requested Permanent and Temporary Confidential exhibits are listed as follows: CONFIDENTIAL LIST Permanent 1 Block Diagram 2 Operational Descriptions 3 Schematics Short-Term 4 External Photos 5 Internal Photos 6 Test-Setup Photos 7 User Manual The Applicant understands that pursuant to Rule 0.457, disclosure of this application and all accompanying documentations, where applicable, will not be made public before the date of the Grant for this application. Sincerely Yours, Name / Title : Sang-il, Nam / Senior Manager Company Name : NIDEC MOBILITY KOREA CORPORATION
NIDEC MOBILITY KOREA CORPORATION Model: NMOK-370W 790-12, Bogaewonsam-ro, Bogae-myeon, Anseong- si, Gyeonggi-do, Korea Made in Korea 2.Label Location Bottom view of EUT 4.5 cm 3.0 cm FCC/ICLabel 1.FCC/ICLabelDrawing This device complies with part 15 of the FCC rules Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. FCCID:2AV76-NMOK-370W
SGS Korea Co., Ltd. 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 Tel. +82 31 428 5700 / Fax. +82 31 427 2370 http://www.sgsgroup.kr Report Number: F690501-RF-RTL007037 Page: 2 of 17 RTT7081-02(2020.10.05)(0) A4(210 mm * 297 mm) INDEX Table of Contents 1. General Information -------------------------------------------------------------------------------------- 3 2. Electronic Field and Magnetic Field------------------------------------------------------------------ 6 SGS Korea Co., Ltd. 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 Tel. +82 31 428 5700 / Fax. +82 31 427 2370 http://www.sgsgroup.kr Report Number: F690501-RF-RTL007037 Page: 3 of 17 RTT7081-02(2020.10.05)(0) A4(210 mm * 297 mm) 1. General Information 1.1. Testing Laboratory SGS Korea Co., Ltd. (Gunpo Laboratory) - 10-2, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 - 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 - Designation number: KR0150 All SGS services are rendered in accordance with the applicable SGS conditions of service available on request and accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx. Phone No. : +82 31 688 0901 Fax No. : +82 31 688 0921 1.2. Details of Applicant Applicant : NIDEC MOBILITY KOREA CORPORATION Address : 790-12, Bogaewonsam-ro, Bogae-myeon, Anseng-si, Gyeonggi-do, South Korea, 17507 Contact Person : Nam, Sang-il Phone No. : +82 2 850 5789 1.3. Details of Manufacturer Company : Same as applicant Address : Same as applicant 1.4. Description of EUT Kind of Product WIRELESS POWER CHARGING SYSTEM Model Name NMOK-370W Serial Number 96560-BQ010 Power Supply DC 12.0 V Operation Mode 5 W, 10 W, Idle Frequency Range 5 W 127.7 ㎑ 10 W 127.7 ㎑ Idle 127.7 ㎑ Antenna Type Coil Antenna Antenna Part Number 95560-L1410 H/W Version 1.00 S/W Version 1.00 SGS Korea Co., Ltd. 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 Tel. +82 31 428 5700 / Fax. +82 31 427 2370 http://www.sgsgroup.kr Report Number: F690501-RF-RTL007037 Page: 4 of 17 RTT7081-02(2020.10.05)(0) A4(210 mm * 297 mm) 1.5. Test Equipment List Equipment Manufacturer Model S/N Cal. Date Cal. Interval Cal. Due Electric and Magnetic field Probe analyzer NARDA EHP 200AC 170WX91017 04/16/2026 Annual 04/16/2027 DC Power Supply Agilent U8002A MY53150029 11/28/2025 Annual 11/28/2026 Anechoic Chamber SY Corporation L × W × H (9.6 m × 6.4 m × 6.6 m) N/A N.C.R. N/A N.C.R. ▶ Support Equipment Description Manufacturer Model FCC ID SAMSUNG Mobile Phone Samsung Electronics Co., Ltd. SM-N950N A3LSMN950KOR Lap top Lenovo T430 - 1.6. Summary of Test Results The EUT has been tested according to the following specifications: APPLIED STANDARD: FCC Part 1 Subpart I Section Test Item(s) Result 1.1307(b) 1.1310(e)(1) Electronic Field and Magnetic Field Pass 1.7. Test Report Revision Revision Report Number Date of Issue Description 0 F690501-RF-RTL007037 2026.06.04 Initial SGS Korea Co., Ltd. 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 Tel. +82 31 428 5700 / Fax. +82 31 427 2370 http://www.sgsgroup.kr Report Number: F690501-RF-RTL007037 Page: 5 of 17 RTT7081-02(2020.10.05)(0) A4(210 mm * 297 mm) 1.8. Measurement Uncertainty Where relevant, the following measurement uncertainty levels have been estimated for tests performed on the apparatus: Parameter Uncertainty Electric Field 19.22 % Magnetic Field 19.08 % All measurement uncertainty values are shown with a coverage factor of k=2 to indicate a 95 % level of confidence. 1.9. Worst Case of Test Configurations In order to check all kinds of possible configurations, EUT was evaluated with appropriate client and under each charging condition as below table. Charging mode With client device Mode Description Model FCC ID SM-N950N A3LSMN950KOR 5 W, 10 W 126.7 ㎑ ~ 128.7 ㎑ 1 % of battery 50 % of battery 99 % of battery Mode Battery Frequency (㎑) E-field Strength (V/m) H-field Strength (A/m) 5 W 1 % 127.7 52.927 1.381 50 % 52.271 1.280 99 % 52.082 1.301 10 W 1 % 63.210 1.331 50 % 61.536 1.305 99 % 61.885 1.104 Note; - EUT was investigated with client device under normal charging condition as above then worst value was only reported. SGS Korea Co., Ltd. 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 Tel. +82 31 428 5700 / Fax. +82 31 427 2370 http://www.sgsgroup.kr Report Number: F690501-RF-RTL007037 Page: 6 of 17 RTT7081-02(2020.10.05)(0) A4(210 mm * 297 mm) 2. Electronic Field and Magnetic Field 2.1. Isotropic Probe Test Setup The measurement probe (EHP-200AC) is a regular hexahedron and supports 3-axis isotropic probe. A: Front of measurement probe B: Right of measurement probe C: Rear of measurement probe D: Left of measurement probe E: Top of measurement probe *Bottom of measurement probe is not used to measure RF exposure condition owing to connection with a stick. - measurement isotropic probe was investigated by rotating the probe through various angles for one of the EUT’s sides as below. Measurement Point A B C D E Direction Front Right Rear Left Top Measurement Point A to B B to C C to D D to A N/A Direction Front to Right Right to Rear Rear to Left Left to Front - Measurement Point A to E B to E C to E D to E N/A Direction Front to Top Right to Top Rear to Top Left to Top - - When the worst angle among all angles was found, RF exposure measurement should be adjusted from worst angle. - Worst Case Mode Condition Isotropic Probe position 5W E-Field Side D H-Field Side A 10W E-Field Side D H-Field Side A SGS Korea Co., Ltd. 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 Tel. +82 31 428 5700 / Fax. +82 31 427 2370 http://www.sgsgroup.kr Report Number: F690501-RF-RTL007037 Page: 7 of 17 RTT7081-02(2020.10.05)(0) A4(210 mm * 297 mm) 2.2. EUT Test Setup 2.3. Measurement procedure a) The RF exposure test was performed in anechoic chamber. b) The measurement probe was placed at test distance (4, 6, 8, 10, 15 ㎝) which is between the edge of the charger and the geometric center of probe. c) Measurement was performed on each side of th…
Text truncated - open the document above for the full version.
Item Contents Antenna Type Coil Antenna Antenna peak gain - ㏈i Manufacturer YS Mobility #1105, Ace Techno 10th, 196 Gasan Digital 1-ro, Geumcheon-gu, Seoul, South Korea, 08502 Model name N/A Test laboratory - Size Information Length : 5.3 cm / Width : 4.7 cm Antenna Information coil antenna Width Length
SGS Korea Co., Ltd. 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 Tel. +82 31 428 5700 / Fax. +82 31 427 2370 http://www.sgsgroup.kr Report Number: F690501-RF-RTL007038 Page: 2 of 26 RTT7081-02(2020.10.05)(0) A4(210 mm * 297 mm) INDEX Table of Contents Page 1. General Information ----------------------------------------------------------------------- 3 2. Field Strength of Fundamental and Spurious Emission--------------------------- 7 3. 20 ㏈ Bandwidth -------------------------------------------------------------------------- 22 4. Antenna Requirement --------------------------------------------------------------------- 26 SGS Korea Co., Ltd. 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 Tel. +82 31 428 5700 / Fax. +82 31 427 2370 http://www.sgsgroup.kr Report Number: F690501-RF-RTL007038 Page: 3 of 26 RTT7081-02(2020.10.05)(0) A4(210 mm * 297 mm) 1. General Information 1.1. Testing Laboratory SGS Korea Co., Ltd. (Gunpo Laboratory) - 10-2, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 - 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 - Designation number: KR0150 All SGS services are rendered in accordance with the applicable SGS conditions of service available on request and accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx. Phone No. : +82 31 688 0901 Fax No. : +82 31 688 0921 1.2. Details of Applicant Applicant : NIDEC MOBILITY KOREA CORPORATION Address : 790-12, Bogaewonsam-ro, Bogae-myeon, Anseng-si, Gyeonggi-do, South Korea, 17507 Contact Person : Nam, Sang-il Phone No. : +82 2 850 5789 1.3. Details of Manufacturer Company : Same as applicant Address : Same as applicant 1.4. Description of EUT Kind of Product WIRELESS POWER CHARGING SYSTEM Model Name NMOK-370W Serial Number 96560-BQ010 Power Supply DC 12.0 V Operation Mode 5 W, 10 W, Idle Frequency Range 5 W 127.7 ㎑ 10 W 127.7 ㎑ Idle 127.7 ㎑ Antenna Type Coil Antenna H/W Version 1.00 S/W Version 1.00 SGS Korea Co., Ltd. 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 Tel. +82 31 428 5700 / Fax. +82 31 427 2370 http://www.sgsgroup.kr Report Number: F690501-RF-RTL007038 Page: 4 of 26 RTT7081-02(2020.10.05)(0) A4(210 mm * 297 mm) 1.5. Test Equipment List Equipment Manufacturer Model S/N Cal. Date Cal. Interval Cal. Due Signal Generator R&S SMA100B 106887 10/20/2025 Annual 10/20/2026 Spectrum Analyzer R&S FSV30 103454 12/17/2025 Annual 12/17/2026 DC Power Supply Agilent U8002A MY48490027 12/02/2025 Annual 12/02/2026 Loop Antenna Schwarzbeck Mess-Elektronik FMZB 1519 1519-039 10/01/2025 Biennial 10/01/2027 Bilog Antenna Schwarzbeck Mess-Elektronik VULB 9163 01126 03/05/2025 Biennial 03/05/2027 EMI Test Receiver R&S ESU26 100109 01/21/2026 Annual 01/21/2027 Spectrum Analyzer Agilent N9020A MY53421758 09/10/2025 Annual 09/10/2026 Preamplifier H.P. 8447F 2944A03909 08/07/2025 Annual 08/07/2026 Turn Table Innco systems GmbH DS 1200 S N/A N.C.R. N/A N.C.R. Controller Innco systems GmbH CONTROLLER CO3000-4P CO3000/963/38 330516/L N.C.R. N/A N.C.R. Antenna Mast Innco systems GmbH MA4640-XP-ET MA4640/536/38 330516/L N.C.R. N/A N.C.R. Anechoic Chamber SY Corporation L × W × H (9.6 m × 6.4 m × 6.6 m) N/A N.C.R. N/A N.C.R. Coaxial Cable 1) SENSORVIEW NMST-13A26-NMST-5 m TPC240219000 4 10/13/2025 Semi- Annual 04/13/2026 04/17/2026 10/17/2026 Coaxial Cable 1) SENSORVIEW NMST-13A26-NMST-10 m TPC240219000 1 10/13/2025 Semi- Annual 04/13/2026 04/17/2026 10/17/2026 Coaxial Cable 2) Qualwave QT50P-40-KK-1.5 24270074 10/10/2025 Semi- Annual 04/10/2026 04/10/2026 10/10/2026 ▶ Support equipment Description Manufacturer Model FCC ID Samsung Mobile phone Samsung Electronics Co., Ltd. SM-N950N A3LSMN950U Note; 1) The equipment was not used for testing during the period from 04/12/2026 to 04/17/2026 2) The equipment was not used for testing during the period from 04/09/2026 to 04/10/2026 SGS Korea Co., Ltd. 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 Tel. +82 31 428 5700 / Fax. +82 31 427 2370 http://www.sgsgroup.kr Report Number: F690501-RF-RTL007038 Page: 5 of 26 RTT7081-02(2020.10.05)(0) A4(210 mm * 297 mm) 1.6. Summary of Test Results The EUT has been tested according to the following specifications: Applied standard: FCC Part 15 Subpart C Section Test Item(s) Result 15.209 Radiated emission, Spurious Emission and Field Strength of Fundamental Pass 2.1049 20 ㏈ Bandwidth Pass 15.207 AC Power Line Conducted Emission N/A 1) Note; 1) The AC power line test was not performed because the EUT use battery power for operation and which do not operate from the AC power lines. 1.7. Test Procedure(s) The measurement procedures described in the American National Standard of Procedure for Compliance Testing of unlicensed Wireless Devices (ANSI C63.10-2020). 1.8. Sample Calculation Where relevant, the following sample calculation is provided: Field strength level (㏈㎶/m) = Measured level (㏈㎶) + Antenna factor (㏈/m) + Cable loss (㏈) + (AMP (㏈)) SGS Korea Co., Ltd. 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 Tel. +82 31 428 5700 / Fax. +82 31 427 2370 http://www.sgsgroup.kr Report Number: F690501-RF-RTL007038 Page: 6 of 26 RTT7081-02(2020.10.05)(0) A4(210 mm * 297 mm) 1.9. Measurement Uncertainty Where relevant, the following measurement uncertainty levels have been estimated for tests performed on the apparatus: Parameter Uncertainty 20 ㏈ Bandwidth 0.01 ㎑ Occupied Bandwidth 0.01 ㎑ Radiated Emission, 9 ㎑ to 30 ㎒ H 3.60 ㏈ V 3.60 ㏈ Radiated Emission, below 1 ㎓ H 5.50 ㏈ V 5.10 ㏈ All measurement uncertainty values are shown with a coverage factor of k=2 to indicate a 95 % level of confidence. 1.10. Test Report Revision Revision Report Number Date of Issue Description 0 F690501-RF-RTL007038 2026.06.04 Initial 1.11. Worst Case of Test Configurations Charging mode with client device Mode Description Model: SM-N950N FCC ID: A3LSMN950U 5 W 10 W 1 % of battery 50 % of battery 99 % of battery 127.7 ㎑ 127.7 ㎑ Mode Battery Frequency (㎑) Detect Mode Reading (㏈㎶) 5 W 1 % 127.7 ㎑ Average 63.20 50 % 6…
Text truncated - open the document above for the full version.
5809 US-2, Suite B, Albeni Plaza · Priest River, 83856 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.1277 MHz - 0.1277 MHz | - |
WIRELESS POWER CHARGING SYSTEM
Equipment Class
DXX - Part 15 Low Power Communication Device TransmitterWIRELESS POWER CHARGING SYSTEM
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
WIRELESS POWER CHARGING SYSTEM
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
WIRELESS POWER CHARGING SYSTEM
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
WIRELESS POWER CHARGING SYSTEM
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz