Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a res idential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions,may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Guangzhou Rantin Technology Co., Ltd Nov.11, 2020 Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Subject: Explanation of differences between product types FCC ID : 2AV7N-BRS Model Number: BR1, BR2 To Whom It May Concern: We, The Guangzhou Rantin Technology Co., Ltd hereby declare that the model : BR2 is identical with the model : BR1, except the model name. Except for the different above, no other modification is performed. Sincerely, Signature: Guangzhou Rantin Technology Co., Ltd Contact person: joe huang
Guangzhou Rantin Technology Co., Ltd Agent Authorization Company: Guangzhou Rantin Technology Co., Ltd Address: Building D, Kengkou digital base,No.9,Huaxi Road, Liwan District, Guangzhou,China Product Name: Donner Bluetooth 5.0 Audio Receiver Model Number(s): BR1, BR2 Product Description: Donner Bluetooth 5.0 Audio Receiver We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: 2020-11-11 Name: joe huang Company: Guangzhou Rantin Technology Co., Ltd
Guangzhou Rantin Technology Co., Ltd Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2020-11-05 Subject; Request for Confidentiality FCC ID: 2AV7N-BRS To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely Guangzhou Rantin Technology Co., Ltd Contact person: joe huang
External Photos ALL VIEW-1 OF EUT EXTERNAL VIEW-1 OF EUT EXTERNAL VIEW-2 OF EUT EXTERNAL VIEW-3 OF EUT EXTERNAL VIEW-4 OF EUT EXTERNAL VIEW-5 OF EUT EXTERNAL VIEW-6 OF EUT EXTERNAL VIEW-7 OF EUT EXTERNAL VIEW-8 OF EUT Adapter Series Model--BR2
FCC ID Label Location FCC ID: 2AV7N-BRS
Internal Photos INTERNAL VIEW-1 OF EUT INTERNAL VIEW-2 OF EUT INTERNAL VIEW-3 OF EUT INTERNAL VIEW-4 OF EUT
Report No.: AGC10328201001FE03 Page 50 of 72 EUT Donner Bluetooth 5.0 Audio Receiver Model Name BR1 Temperature 25°C Relative Humidity 55.4% Pressure 960hPa Test Voltage Normal Voltage Test Mode Mode 7 Antenna Vertical PK AV RESULT: PASS Report No.: AGC10328201001FE03 Page 51 of 72 EUT Donner Bluetooth 5.0 Audio Receiver Model Name BR1 Temperature 25°C Relative Humidity 55.4% Pressure 960hPa Test Voltage Normal Voltage Test Mode Mode 9 Antenna Horizontal PK AV RESULT: PASS Report No.: AGC10328201001FE03 Page 52 of 72 EUT Donner Bluetooth 5.0 Audio Receiver Model Name BR1 Temperature 25°C Relative Humidity 55.4% Pressure 960hPa Test Voltage Normal Voltage Test Mode Mode 9 Antenna Vertical PK AV RESULT: PASS Note: The factor had been edited in the “Input Correction” of the Spectrum Analyzer. The 8DPSK modulation is the worst case and recorded in the report. Report No.: AGC10328201001FE03 Page 53 of 72 11. NUMBER OF HOPPING FREQUENCY 11.1. MEASUREMENT PROCEDURE The EUT shall have its hopping function enabled. Use the following spectrum analyzer settings: 1. Span: The frequency band of operation. Depending on the number of channels the device supports, it may be necessary to divide the frequency range of operation across multiple spans, to allow the individual channels to be clearly seen. 2. RBW: To identify clearly the individual channels, set the RBW to less than 30% of the channel spacing or the 20 dB bandwidth, whichever is smaller. 3. VBW ≥ RBW. Sweep: Auto. Detector function: Peak. Trace: Max hold. 4. Allow the trace to stabilize. 11.2. TEST SETUP (BLOCK DIAGRAM OF CONFIGURATION) Same as described in section 8.2 11.3. MEASUREMENT EQUIPMENT USED The same as described in section 6 11.4. LIMITS AND MEASUREMENT RESULT TOTAL NO. OF HOPPING CHANNEL LIMIT (NO. OF CH) MEASUREMENT (NO. OF CH) RESULT >=15 79 PASS TEST PLOT FOR NO. OF TOTAL CHANNELS Note: The GFSK modulation is the worst case and recorded in the report. Report No.: AGC10328201001FE03 Page 54 of 72 12. TIME OF OCCUPANCY (DWELL TIME) 12.1. MEASUREMENT PROCEDURE The EUT shall have its hopping function enabled. Use the following spectrum analyzer settings: 1. Span: Zero span, centered on a hopping channel. 2. RBW shall be≤channel spacing and where possible RBW should be set >> 1 / T, where T is the expected dwell time per channel. 3. Sweep: As necessary to capture the entire dwell time per hopping channel; where possible use a video trigger and trigger delay so that the transmitted signal starts a little to the right of the start of the plot. The trigger level might need slight adjustment to prevent triggering when the system hops on an adjacent channel; a second plot might be needed with a longer sweep time to show two successive hops on a channel. 4. Detector function: Peak. Trace: Max hold. 5. Use the marker-delta function to determine the transmit time per hop. 6. Repeat the measurement using a longer sweep time to determine the number of hops over the period specified in the requirements. The sweep time shall be equal to, or less than, the period specified in the requirements. Determine the number of hops over the sweep time and calculate the total number of hops in the period specified in the requirements, using the following equation: (Number of hops in the period specified in the requirements) = (number of hops on spectrum analyzer) × (period specified in the requirements / analyzer sweep time) 7. The average time of occupancy is calculated from the transmit time per hop multiplied by the number of hops in the period specified in the requirements. 12.2. TEST SETUP (BLOCK DIAGRAM OF CONFIGURATION) Same as described in section 8.2 12.3. MEASUREMENT EQUIPMENT USED The same as described in section 6 12.4. LIMITS AND MEASUREMENT RESULT Channel Time of Pulse for DH5 (ms) Number of hops in the period specified in the requirements Sweep Time (ms) Limit (ms) Low 2.881 26*4 299.665 400 Middle 2.881 27*4 311.193 400 High 2.881 27*4 311.191 400 Note: The 8DPSK modulation is the worst case and recorded in the report. Report No.: AGC10328201001FE03 Page 55 of 72 TEST PLOT OF LOW CHANNEL Report No.: AGC10328201001FE03 Page 56 of 72 TEST PLOT OF MIDDLE CHANNEL Report No.: AGC10328201001FE03 Page 57 of 72 TEST PLOT OF HIGH CHANNEL Report No.: AGC10328201001FE03 Page 58 of 72 13. FREQUENCY SEPARATION 13.1. MEASUREMENT PROCEDURE The EUT shall have its hopping function enabled. Use the following spectrum analyzer settings: 1. Span: Wide enough to capture the peaks of two adjacent channels. 2. RBW: Start with the RBW set to approximately 30% of the channel spacing; adjust as necessary to best identify the center of each individual channel. 3. Video (or average) bandwidth (VBW) ≥ RBW. 4. Sweep: Auto. e) Detector function: Peak. f) Trace: Max hold. g) Allow the trace to stabilize. Use the marker-delta function to determine the separation between the peaks of the adjacent channels. 13.2. TEST SETUP (BLOCK DIAGRAM OF CONFIGURATION) Same as described in section 6.2 13.3. MEASUREMENT EQUIPMENT USED The same as described in section 6.3 13.4. LIMITS AND MEASUREMENT RESULT CHANNEL CHANNEL SEPARATION LIMIT RESULT MHz Pass CH38-CH39 1.001 >= 2/3 20 dB BW TEST PLOT FOR FREQUENCY SEPARATION Note: The GFSK modulation is the worst case and recorded in the report. Report No.: AGC10328201001FE03 Page 59 of 72 14. FCC LINE CONDUCTED EMISSION TEST 14.1. LIMITS OF LINE CONDUCTED EMISSION TEST Frequency Maximum RF Line Voltage Q.P. (dBμV) Average (dBμV) 150kHz~500kHz 66-56 56-46 500kHz~5MHz 56 46 5MHz~30MHz 60 50 Note: 1. The lower limit shall apply at the transition frequency. 2. The limit decreases linearly with the logarithm of the frequency in the range 0.15 MHz to 0.50 MHz. 14.2. BLOCK DIAGRAM OF LINE CONDUCTED EMISSION TEST EUT & Support Units Report No.: AGC10328201001FE03 Page 60 of 72 14.3. PRELIMINARY PROCEDURE OF LINE CONDUCTED EMISSION TEST 1. The equipment was set up as per the test configuration to simulate typical actual usage per the user’s manual. Wh…
Text truncated - open the document above for the full version.
Test Setup Photos RADIATED EMISSION TEST SETUP BELOW 1GHz RADIATED EMISSION TEST SETUP ABOVE 1GHz LINE CONDUCTED EMISSION TEST SETUP CONDUCTED TEST SETUP
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 500.00 µW |
Portable PA Speaker
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterPortable PA Speaker
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterDIGITAL PIANO
Equipment Class
DTS - Digital Transmission SystemMINI DIGITAL KEYBOARD
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterAudio Speaker
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter