Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Enbrighten VIBE Spectrum Tape Lights – Manual – 85822 [Insert Thank you for your purchase info] Overview 1. This product is our company's latest design product. It adopts the control method of infrared remote control plus WiFi graffiti. 2. It can quickly and conveniently realize full-color adjustment and brightness adjustment, and can meet the application needs of our customers. INSTALLING BATTERY (REMOTE) 1. Simultaneously push in the tab as you pull out the battery drawer. 2. Place a new CR2025 battery in the drawer with (+) side of the battery facing up (see diagram on back of remote). 3. Push the battery drawer into the remote until it snaps into place. TEST YOUR TAPE LIGHTS Test your tape lights before you begin installation. 1. Fully extend the tape light. 2. Connect the power adapter to a 120VAC 60Hz wall outlet. 3. Press the ON/OFF button on the in-line controller to ensure tape lights work properly. CAUTION: Do not plug in the tape light until it is removed from the reel and fully extended, as it can get hot and damage the product. SETUP Remotely operate your smart tape lights with the easy-to-use Enbrighten app. Follow the available instructions and resources to set up your smart device. [Insert standard 4-square design with the following text] Download the app Scan the QR code or search Enbrighten on the Apple App Store or on Google Play Setup and installation 1. Create an account in the Enbrighten app 2. Assemble the smart tape lights according to the provided instructions Setup and installation 3. Plug the smart tape lights into a wall outlet 4. Add devices, control the tape lights from anywhere and create schedules Voice control Voice control works with Amazon Alexa or Google Assistant Select "Support" in the Enbrighten app or follow the steps in the Amazon Alexa or Google Home app to connect your Enbrighten account INSIDE THE BOX [Images of each item with corresponding letter and text shown below. Be sure to point out programming button on power cord, as well.] A. RGBIC LED tape lights (10ft.) x1 B. Power adapter with 5ft. cord, pairing button and mic for MusicSync C. IR remote control with CR2025 battery INSTALLATION • CAUTION: Do not connect the power supply while installing the tape lights. 1. Determine the best placement for your tape lights, making sure to adhere to the following: • Remove any nails, metal or other conductive objects from the installation surface before attaching tape lights, as it could cause the lights to short circuit. • Do not stick the tape lights to a glass surface. • Avoid installing lights near heat sources or potentially dangerous sources, such as sharp objects, candles, liquids, corrosive chemicals, etc. • Select a location within reach of the nearest wall outlet. 2. Clean the mounting surface. 3. Connect the tape lights to the in-line controller. 4. Remove the adhesive backing from the back of the tape lights, then firmly press the tape lights onto a flat surface. 5. Avoid bending the tape lights where the LEDs and circuits are located, as it could cause damage. If bending the tape lights is required for your chosen location, bend the lights in a loose loop (see Fig. 1). 6. Connect the power adapter to the in-line controller and plug it into a 120VAC 60Hz wall outlet. MANUAL OPERATION ON: Press the button once. OFF: Press the button twice. Change-color mode: Press and release the button to advance through a variety of preset color combinations and effects. Additional options are available through the Enbrighten app. Pairing mode: Press button for 10 seconds for app pairing mode. REMOTE CONTROL OPERATION The remote control uses infrared (IR) technology to communicate with the tape lights. When using the remote control, point it at the tape lights’ IR receiver on the in-line controller, making sure there are no obstructions in the signal path. Use the included IR remote to cycle through the various modes, adjust brightness settings and more. Avoid any extra IR interference by pointing the remote at the in-controller. [Insert image of remote with the following button callouts] 1. ON/OFF: Press to activate or deactivate lights 2. White Select: Press to select warm white (3000K) or cool white (4000K) 3. Modes: Press to change modes 4. Directional Modes: Press to change direction of active mode 5. MusicSync: Press for lights to react to sound 6. Single Color: Press repeatedly to advance through color options 7. Multicolor Modes: Press to select preset multicolor modes 8. Set Mode: Press and hold to enter SET mode. 9. Increase/Decrease: a. In static mode, press to adjust brightness level of single color b. In dynamic mode, press to adjust light speed c. In SET mode, press to increase or decrease the number of ICs WiFi CONTROL OPERATION 1. First connection: Long press button to enter the network configuration mode, click button to switching mode,connect the power controller and light strip, the light flashes and enters the network distribution mode, open the Tuya app. 2. Automatically identify devices and add them. You can confirm whether to add the device by clicking the Add option. 3. Add a device Enter the WiFi name and password to connect to the device and proceed to the next step (WIFI can only use 2.4g, other devices may not be recognized and may not be connected. 4. Enter the WiFi name and password to directly proceed to the next step of adding the device, wait a few seconds and then add it successfully. 5. After adding successfully, click Finish to proceed to the next step. 6. After clicking Finish, you can adjust the color, brightness, dynamic mode, dynamic mode speed and timing function of the light strip according to your direct preferences. TROUBLESHOOTING PROBLEM CORRECTIVE ACTION Cannot pair to the Enbrighten app • Confirm the tape lights are powered. • Enable Bluetooth on your smartphone. • Position the tape lights and smartphone within 6ft. of the Wi-Fi router. • Ensure your smartphone is connected to a 2.4GHz Wi-Fi network – 5GHz n…
Text truncated - open the document above for the full version.
1/1 US Agent for Service of Process LETTER OF ATTESTATION TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 US Agent for Service of Process: Company Name: Jasco Products Company LLC FRN: 0017309360 Contact Name: Mr Mark W Simpkins Address: 10 E. Memorial Rd., Oklahoma City, OK 73114 Telephone No: (405)302-2370 Email: [email protected] EIN:80-0529660 Applicant: Company name: GUANGDONG OML TECHNOLOGYCO.,LTD Product Description: Tuya controller Grantee code: 2AVBD FCC ID: 2AVBD-TUYA5-24V FRN: 0029028016 Contact Name: Yong Hua Duan Address: NO.38 HETONG ROAD, DONGFENG TOWN ZHONGSHAN Guangdong, china Telephone No: 0086 760-66181888 Fax No: 0086760-28132190 Email: [email protected] [GUANGDONG OML TECHNOLOGYCO.,LTD] certifies that, as of the date of this filing of the application with the TCB, [Jasco Products Company LLC] is our designated US agent for service of process for the above referenced FCC ID. [GUANGDONG OML TECHNOLOGYCO.,LTD] accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any commission related proceeding involving equipment. [Jasco Products Company LLC] accepts, as of the date of the filing of the application, the obligation of the designated US agent for service of process for the above reference FCC ID. The US Agent for Service of Process is aware of and agrees to comply with the requirements outlined in the FCC Equipment Authorization Program, Report and Order FCC 22-84, and clause § 2.911. The Applicant is aware of and agrees to comply with the requirements outlined in the FCC Equipment Authorization Program, Report and Order FCC 22-84, and clause § 2.911. Date: 2024/12/20 Applicant’s Name: Yong Hua Duan US Agent’s Name: Mr Mark W Simpkins Title: Quality engineer Title: Technical Manager Signature Signature
Attestation Statement. Old Code: C5266091 24 New Code: 00015544 Ed.3 Change reason: FRN is added to the Applicant information section. 1/1 TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 The Commission adopted rules that prohibit equipment authorization for “covered” telecommunications equipment and video surveillance equipment produced by entities identified on the Commission’s Covered List 1 , which is periodically updated. See the Covered List for more details. This Attestation Statement is to confirm that we follow the Section 2.911(d)(5)(i)-(ii) Applicant Company name: GUANGDONG OML TECHNOLOGYCO.,LTD Grantee code: 2AVBD FCC ID: 2AVBD-TUYA5-24V FRN: 0029028016 Contact Name: Yong Hua Duan Address: NO.38 HETONG ROAD, DONGFENG TOWN ZHONGSHAN Guangdong, china Telephone No: 0086 760-66181888 Fax No: 0086760-28132190 Email: [email protected] i. [GUANGDONG OML TECHNOLOGYCO.,LTD] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. The applicant must sign this certification. ii. [GUANGDONG OML TECHNOLOGYCO.,LTD] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [is not] (as a specifically named entity or any of its subsidiaries or affiliates) identified on the Covered List as an entity producing “covered” equipment. The applicant must sign this certification. Date: 2024/12/ [GUANGDONG OML TECHNOLOGYCO.,LTD] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [is not] identified on the Covered List as an entity producing “covered” equipment . 20 Applicant’s Name: Yong Hua Duan Title: Quality engineer Signature 1 The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist
C5266091_X8_Ed.1 1/1 Letter of Authorization Company: GUANGDONG OML TECHNOLOGYCO.,LTD Address: NO.38 HETONG ROAD, DONGFENG TOWN ZHONGSHAN Guangdong, china Product Name: Tuya controller Model Number: Tuya 5-24V FCC Identifier: 2AVBD-TUYA5-24V We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: Yong Hua Duan 2024-12-20 Title: Quality engineer Signature of applicant:
C5266091_X10_Ed.2 1/1 GUANGDONG OML TECHNOLOGYCO.,LTD Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046w Date: 2024-12-20 Subject: Request for Confidentiality FCC ID: 2AVBD-TUYA5-24V To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual ☐ NOTE 1 ☐ Internal Photos ☐ NOTE 1 ☐ Parts List / Tune Up ☐ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No NOTE 1: Long-Term Confidentiality may be permitted under special conditions (See II. LONG-TERM CONFIDENTIALITY, Section 3 of KDB 726920, use last in force) NOTE 2: Short-Term Confidentiality can be requested for a maximum of 180 days from the date of the grant. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In case of short-term Confidentiality, the applicant requests the exhibits selected above are withheld from public view for a period of ______ days from the date of the Grant of Equipment Authorization and prior to marketing. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Yong Hua Duan Title: Quality engineer
Shenzhen QC Testing Laboratory Co., Ltd. Page 1 of3 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 http://www.qctest.com.cn Product Name: Tuya controller Test Model No.: Tuya 5-24V EUT Constructional Details Shenzhen QC Testing Laboratory Co., Ltd. Page 2 of3 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 http://www.qctest.com.cn Shenzhen QC Testing Laboratory Co., Ltd. Page 3 of3 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 http://www.qctest.com.cn ------End------
Model: Tuya 5-24V FCC ID: 2AVBD-TUYA5-24V
Shenzhen QC Testing Laboratory Co., Ltd. Page 1 of3 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 http://www.qctest.com.cn Product Name: Tuya controller Test Model No.: Tuya 5-24V EUT Constructional Details: Shenzhen QC Testing Laboratory Co., Ltd. Page 2 of3 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 http://www.qctest.com.cn Antenna Shenzhen QC Testing Laboratory Co., Ltd. Page 3 of3 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 http://www.qctest.com.cn ------End------
Shenzhen QC Testing Laboratory Co., Ltd. Page 1 of 2 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 http://www.qctest.com.cn FCC ID: 2AVBD-TUYA5-24V RF Exposure Evaluation FCC KDB publication 447498 D01 General RF Exposure Guidance v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies. Limits The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b) Limits for Maximum Permissible Exposure (MPE) Frequency range (MHz) Electric field strength (V/m) Magnetic field strength (A/m) Power density (mW/cm 2 ) Averaging time (minutes) (A) Limits for Occupational/Controlled Exposures 0.3–3.0 614 1.63 *(100) 6 3.0–30 1842/f 4.89/f *(900/f 2 ) 6 30–300 61.4 0.163 1.0 6 300–1500 f/300 6 1500–100,000 5 6 (B) Limits for General Population/Uncontrolled Exposure 0.3–1.34 614 1.63 *(100) 30 1.34–30 824/f 2.19/f *(180/f 2 ) 30 30–300 27.5 0.073 0.2 30 300–1500 f/1500 30 1500–100,000 1.0 30 f = frequency in MHz Friis transmission formula: Pd = (Pout*G)/(4*pi*r 2 ) Where Pd = power density in mW/cm 2 , Pout = output power to antenna in mW; G = gain of antenna in linear scale, Pi = 3.1416; R = distance between observation point and center of the radiator in cm Pd id the limit of MPE, 1 mW/cm 2 . If we know the maximum gain of the antenna and the total power input to the antenna, through the calculation, we will know the distance r where the MPE limit is reached. Test Procedure Software provided by client enabled the EUT to transmit and receive data at lowest, and highest channel individually. Shenzhen QC Testing Laboratory Co., Ltd. Page 2 of 2 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 http://www.qctest.com.cn Test Result of RF Exposure Evaluation Antenna Gain: 2.499dBi For 2.4G Wi-Fi worst case Test Frequency (MHz) Minimum Separation Distance (cm) Output Power (dBm) Target power (dBm) Target power (mW) Antenna Gain (Numeric) Power Density Limit (mW/cm 2 ) Power Density At 20 cm (mW/cm 2 ) Test Results 2412 20.00 18.53 18±1 79.433 1.78 1 0.0281 Pass 2422 20.00 18.1 18±1 79.433 1.78 1 0.0281 Pass 2437 20.00 17.5 17±1 63.096 1.78 1 0.0223 Pass 2452 20.00 16.62 16±1 50.119 1.78 1 0.0177 Pass 2462 20.00 16.99 17±1 63.096 1.78 1 0.0223 Pass The measurement results comply with the FCC Limit per 47 CFR 2.1091 for the uncontrolled RF Exposure.
Shenzhen QC Testing Laboratory Co., Ltd. Report No.: QCT24LR-2439E-01 Page 1 of 67 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 http://www.qctest.com.cn FCC PART 15.247 TEST REPORT On Behalf of GUANGDONG OML TECHNOLOGY CO., LTD. No. 38 HETONG ROAD, DONGFENG TOWN ZHONGSHAN Guangdong, china FCC ID: 2AVBD-TUYA5-24V Model: Tuya 5-24V December 13, 2024 T his Repo rt Co nc erns: Original Report Equip men t T ype: Tuya controller Test Engineer: LBi Li / Report Number: QCT24LR-2439E-01 Test Date: December 11~12, 2024 Reviewed By: Vincent Yang/ Approved By: Kendy Wang / Prepared By: Shenzhen QC Testing Laboratory Co., Ltd. East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 Shenzhen QC Testing Laboratory Co., Ltd. Report No.: QCT24LR-2439E-01 Page 2 of 67 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 http://www.qctest.com.cn Table of Contents 1. GENERAL INFORMATION ................................................................................................. 5 1.1 Product Description for Equipment under Test (EUT) ............................................................5 1.2 System Test Configuration .....................................................................................................6 1.3 Test Facility ............................................................................................................................7 1.4 Measurement Uncertainty ......................................................................................................7 2. SUMMARY OF TEST RESULTS ........................................................................................ 8 3. LIST OF TEST AND MEASUREMENT INSTRUMENTS .................................................... 9 3.1 Conducted Emission Test ......................................................................................................9 3.2 Radiated Emission Test .........................................................................................................9 3.3 RF Conducted test ............................................................................................................... 10 4. ANTENNA REQUIREMENT .............................................................................................. 11 5. CONDUCTED EMISSIONS ............................................................................................... 12 5.1 Applicable Standard ............................................................................................................. 12 5.2 Limit ..................................................................................................................................... 12 5.3 Test setup ............................................................................................................................ 12 5.4 EMI Test Receiver Setup ..................................................................................................... 12 5.5 Test procedure ..................................................................................................................... 12 5.6 Test Data ............................................................................................................................. 12 6. CONDUCTED PEAK OUTPUT POWER........................................................................... 15 6.1 Applicable Standard ............................................................................................................. 15 6.2 Limit ..................................................................................................................................... 15 6.3 Test setup ............................................................................................................................ 15 6.4 Test Procedure .................................................................................................................... 15 6.5 Test Data ............................................................................................................................. 16 7. CHANNEL BANDWIDTH & 99% OCCUPIED BANDWIDTH ........................................... 17 7.1 Applicable Standard ............................................................................................................. 17 7.2 Limit ..................................................................................................................................... 17 7.3 Test setup ............................................................................................................................ 17 7.4 Test Procedure .................................................................................................................... 17 7.5 Test Data ............................................................................................................................. 17 8. POWER SPECTRAL DENSITY ........................................................................................ 31 8.1 Applicable Standard ............................................................................................................. 31 8.2 Limit ..................................................................................................................................... 31 8.3 Test setup ............................................................................................................................ 31 8.4 Test Procedure .................................................................................................................... 31 8.5 Test Data .........................................................…
Text truncated - open the document above for the full version.
Antenna Specification Summary: ITEM ANT SPEC Model Name Plannar Inverted F Antenna on board Manufacture Shenzhen Xinyu lntelligent Electronic Technology Co.,Ltd. Address 3rd floor, Building 1, Tianhao Industrial Park, No. 2852 Songbai Road, Longteng Community, Shiyan Street, Baoan District, Shenzhen Polarization Horizontal and Vertical Azimuth Beam Pattern Omni-directional Impedance 50 Ohm Frequency(MHz) 2400-2450 MAX. Gain 2.78dBi Antenna Photo & Length (mm) 2.4G- antenna
Shenzhen QC Testing Laboratory Co., Ltd. Page 1 of 2 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 http://www.qctest.com.cn Product Name: Tuya controller Test Model No.: Tuya 5-24V Photograph of Test Setup Conducted Emissions Radiated Emissions (30 MHz - 1 GHz) Shenzhen QC Testing Laboratory Co., Ltd. Page 2 of 2 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 http://www.qctest.com.cn Radiated Emissions (Above 1 GHz)
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 71.00 mW |