FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Dongguan Xintai Instrument Co.,Ltd./
  3. 2AVBO-HTA9

2AVBO-HTA9Thermal imaging camera

Dongguan Xintai Instrument Co.,Ltd.
Thermal imaging camera - FCC ID 2AVBO-HTA9 - Dongguan Xintai Instrument Co.,Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jan 10, 2020
Application Purpose
Original Equipment
Date of Application
Jan 10, 2020
Equipment Note
Thermal imaging camera
Frequency Range
2412.00000000 - 2462.00000000
Company
Dongguan Xintai Instrument Co.,Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Instruction Manual Thermal Imaging Camera Dongguan Xintai Instrument Co.,Ltd. Add: Building F, No. 22 Yuhua Street, Hongye Industrial Zone, Tangxia Town, Dongguan City, Guangdong Province Postcode:523710 Tel:+86-769-82612006 Fax:+86-769-82612005 Website:www.hytechcn.com.cn www.xintest.com.cn www.xintest.en.alibaba.com Email:[email protected] User Manual Version 1.0. September 122019.HT-A8HT-A9 Contents                      Preface Limited Warranty and Limited Responsibility Safety Instruction Preliminary Acquaintance with Infrared Thermal Imager Overview Cleaning of the Products Lens Maintenance Charging of the Battery and Description Performance Index Product Description 1. Instruction to Structure 2. Display Description 3. Key Description Initial Operation Introduction to the Menu 1.“Image Overlapping” Submenu 1.1Description of Image Overlapping 1.2. Application of Image Overlapping 2. Introduction to “Image” Sub-menu 2.1. View Image 2.2. Delete Images                   3. Introduction to “Color Palette” Sub-menu 3.1. Color Palette Description 3.2. Application of Color Palette 4. Introduction to “Emissivity” Sub-menu 4.1. Emissivity Description 4.2. Emissivity Setting 4.3. The Emissivity Value of Common Materials 5. Introduction to “Setting” Sub-menu 5.1. Auto Shutdown Setting 5.2. Intensity Settings 5.3. Language Settings 5.4. Unit Setting 5.5. Time Format Setting 5.6. Time Setting 5.7. Enable/disable of the Highest and Lowest Temperature Cursor 5.8. Wireless WIFI on and off Troubleshooting After-sale Service of the Product www.xintest.com.cnwww.xintest.com.cn Preface Limited warranty and limited responsibility Respected users: How are you! Thank you for purchasing our instrument. In order to use it in a better manner, we remind you to read the instruction for use carefully before use and keep it properly so as to look up in the future use. Xintai Instruments and Apparatus Co., Ltd guarantees that the product enjoys warranty service of one year from the purchase date. But the warranty is not applicable to fuse and disposable battery or the damage caused by improper operation, accidents, negligence, misuse, remodeling, pollution and abnormal condition of the operation environment. The distributor has no right to provide any warranty in the name of Xintai Instruments and Apparatus Co., Ltd. Xintai Instruments and Apparatus Co., Ltd authorizes the retail dealers to provide new products or unused products to final customers but does not authorize them to provide guarantee with wider scope or different contents. Only the products that are purchased through distributors authorized by Xintai Instruments and Apparatus Co., Ltd or products that the purchaser paid according to proper international price can enjoy the warranty support of our company. When the product bought in a country is sent to another country for repair, Xintai Instruments and Apparatus Co., Ltd reserves the right to charge the import fees for the parts and components to be repaired or replaced from the purchasers. When warranty service is repaired, please contact the service center authorized by Xintai Instruments and Apparatus Co., Ltd to obtain the authorization information for return. Then post the product together with problem description to the service center with postage and insurance expenses prepaid. Our company will not undertake any responsibility for any damage occurred during the process of transportation. The product will be posted to the purchaser after repair with the transportation expenses paid by the purchasers. If the product failure is verified by negligence, misuse, pollution, change, accidents or improper operation or handling after inspection, including the over voltage failure caused by use without following the rated value stipulated by the product or daily service wear the of the parts, our company will estimate the repair expenses and carry out repair after obtaining the consent of the purchasers. The product will be posted back to the purchaser after repair with the transportation expenses paid by the purchasers. The guarantee is the only compensation that users can be obtained and does not include other express or implied guarantees. Xintai Instruments and Apparatus Co., Ltd will not undertake any responsibility for any special, indirect, accidental or subsequent damage or loss, including any data loss caused by any reasons or inference. Because some countries or states do not allow implied warranties and incidental or consequential damages.Restrictions, so the above limitation of liability and regulations may not apply to every buyer. The users shall make promise that they familiarize with the application field and occasi on. The purchase indicates that the users are deemed to know the suitability for the products. www.xintest.com.cn 1 www.xintest.com.cn 2 Safety Instruction Considerations Please ensure that you have read and understood the safety precautions described in the following text before using the product so that you can operate it correctly. The safety precautions described in the following text guides you to operate the product and its accessories correctly and safely to avoid damage and loss to you,other people and the device. The warning describes the acts that may cause harm to users. Please observe the following operation in order to avoid electric shock or personal injury. If the product case is damaged, don’t use it continuously. Please contact the local distributors or agents of Xintai under such condition. Warning: Don’t aim the laser pointer at human or animal's eyes. The laser given out by the laser pointer may harm the vision. Please observe the following guide in order not to damage the product: Don’t assemble or dismantle the product without permission. The product is a type of super precise equipment. Don’t try to dismantle, assemble or remodel any part of the product. Repair of the product sho…

Text truncated - open the document above for the full version.

Cover Letter(s)

Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: 2AVBO-HTA9 Product Name: Thermal imaging camera Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commissions rules, we hereby request that the following documents be held confidential: (List here the documents for which you are seeking confidentiality – for example ...) •Schematics •Block diagram •Operation description These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. Dated this 24-12-2019 By: Wang Wei Signature Printed Title: Quality Manager On behalf of : Telephone: +86-769-82612006 Dongguan Xintai Instrument Co.,Ltd. Dongguan Xintai Instrument Co.,Ltd.

Cover Letter(s)

Dongguan Xintai Instrument Co.,Ltd. Building F, No. 13-16, Hongye Industrial Zone, Tangxia Community, Tangxia Town, Dongguan City Guangdong Province, China. TEL: +86-769-82612006 Series Models Description Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 To whom it may concern: Our product (Name: Thermal imaging camera), Models number: HT-A8, HT-A9, HT-H8, proposed certification number FCC ID:2AVBO-HTA9. HT-A8 and HT-H8 only the model’s name and colour are different for marketing requirements. HT-A8 and HT-A9 only different in the Infrared image resolution and Field angle. Except that, they are electrically identical, they have same electrical, PCB and BOM. For more information, please refer to the user’s manual. Sincerely, Signature: Print: Wang Wei Title: Quality Manager Phone number: +86-769-82612006 Email: [email protected]

ID Label/Location Info

FCC ID: 2AVBO-HTA9 Thermal Imaging Camera Temperature Range: -20°C to +450°C -4°F to 842 °F Resolution: 320×240 1.1 丝印 按以上注明 制图 日期 审核 日期 批准 日期 图纸编号 更新说明 HT-A9 面板丝印 FCC ID: 2AVBO-HTA9

Internal Photos

Page 1 of 4 Page 2 of 4 Page 3 of 4 RF Antenna Page 4 of 4

RF Exposure Info

1 / 3 RF EXPOSURE EVALUATION FCC ID: 2AVBO-HTA9 Product Name : Thermal imaging camera Model Name : HT-A9 Serial model : HT-A8,HT-H8 Equipment Type : DTS Specification : 802.11b/g/n (HT20)/n (HT40) Operation Frequency : 2.4G Wi-Fi: 2412-2462MHz for 802.11b/g/n (HT20) 2422-2452MHz for 802.11n (HT40) Number of Channel : 802.11b/g/n(HT20): 11 Channels 802.11n(HT40): 7 Channels Type of Modulation : DSSS with DBPSK/DQPSK/CCK for 802.11b; OFDM with BPSK/QPSK/16QAM/64QAM for 802.11g/n; Antenna installation : PCB Antenna Antenna Gain : 3 dBi Power supply : Battery 4.2V 5000mA Hardware Version : HT-A8-MB-V1.3 Software Version : V2.1.1 2 / 3 Standard Requirement Portable device According to § 15.247(i) and § 1.1307b(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess of the Commission’s guidelines. See KDB 447498 D01 General RF Exposure Guidance v05, section 4. 3. 1. The 1-g and 10-g SAR test exclusion thresholds for 100MHz to 6GHz at test separation distances ≤ 50mm are determined by: [ (max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)]*[ √f(GHz)] ≤3.0 for 1-g SAR and ≤7.5 for 10-g SAR extremity SAR, where ⚫ f(GHz) is the RF channel transmit frequency in GHz ⚫ Power and distance are rounded to the nearest mW and mm before calculation ⚫ The result is rounded to one decimal place for comparison. The test exclusions are applicable only when the minimum test separation distance is ≤ 50mm and for transmission frequencies between 100MHz and 6GHz. When the minimum test separation distance is <5mm, a distance of 5mm is applied to determine SAR test exclusion. Routine SAR evaluation refers to that specifically required by § 2.1093, using measurements or computer simulation. When routine SAR evaluation is not required, portable transmitters with output power greater than the applicable low threshold require SAR evaluation to quality for TCB approval. One antenna is available for the EUT (WIFI product). The minimum separation distance is 5mm. Max output power is Low Channel with 802.11b mode Modulation Maximum Peak Output Power (dBm) Limit Low Channel Middle Channel High Channel 802.11b 12.49 12.18 12.51 1W(30dBm) 802.11g 10.99 10.86 10.84 1W(30dBm) 802.11n-HT20 9.81 9.76 9.78 1W(30dBm) 802.11n-HT40 8.36 8.54 8.35 1W(30dBm) 3 / 3 SAR evaluation Antenna Type :FPCB Antenna Antenna Gain: 3 dBi Modulation Channel Freq. (GHz) Conduct ed power (dBm) Conducte d power (mW) Tune-up power (dBm) Max tune-up power (dBm) Max tune-up power (mW) Distance (mm) Result calculatio n 10g SAR Exclusion threshold SAR test exclusion 2.412 12.49 17.742 12±1 13.00 19.953 <5 6.19753 7.50 YES 2.437 12.18 16.520 12±1 13.00 19.953 <5 6.22957 7.50 YES 2.462 12.51 17.824 12±1 13.00 19.953 <5 6.26144 7.50 YES 2.412 10.99 12.560 10±1 11.00 12.589 <5 3.91038 7.50 YES 2.437 10.86 12.190 10±1 11.00 12.589 <5 3.93059 7.50 YES 2.462 10.84 12.134 10±1 11.00 12.589 <5 3.95070 7.50 YES 2.412 9.81 9.572 9±1 10.00 10.000 <5 3.10612 7.50 YES 2.437 9.76 9.462 9±1 10.00 10.000 <5 3.12218 7.50 YES 2.462 9.78 9.506 9±1 10.00 10.000 <5 3.13815 7.50 YES 2.422 8.36 6.85 8±1 9.00 7.94 <5 2.47239 7.50 YES 2.437 8.54 7.14 8±1 9.00 7.94 <5 2.48003 7.50 YES 2.452 8.35 6.84 8±1 9.00 7.94 <5 2.48766 7.50 YES 802.11b 802.11g 802.11n- HT20 802.11n- HT40 Conclusion: For the max result : 6.26144≤ 7.5 for 10-g SAR, No SAR is required. Signature Chris Du EMC Manager Date:2019-11-30

Test Report

Page 1 of 61 FCC TEST REPORT FCC ID: 2AVBO-HTA9 Product : Thermal imaging camera Model Name : HT-A9 Serial model : HT-A8,HT-H8 Brand : HTI Report No. : PTC19111304001E -FC01 Prepared for Dongguan Xintai Instrument Co.,Ltd Building F, NO. 13-16, Hongye Industrial Zone, Tangxia Community, Tangxia Town, Dongguan City,Guangdong Province,China Prepared by Dongguan Precise Testing & Certification Corp., Ltd. Building D, Baoding Technology Park, Guangming Road 2, Guangming Community, Dongcheng District, Dongguan, Guangdong, China Report No.: PTC19111304001E -FC01 Page 2 of 61 1 TEST RESULT CERTIFICATION Applicant’s name : Dongguan Xintai Instrument Co.,Ltd Address : Building F, NO. 13-16, Hongye Industrial Zone, Tangxia Community, Tangxia Town, Dongguan City,Guangdong Province,China Manufacture's name : Dongguan Xintai Instrument Co.,Ltd Address : Building F, NO. 13-16, Hongye Industrial Zone, Tangxia Community, Tangxia Town, Dongguan City,Guangdong Province,China Product name : Thermal imaging camera Model name : HT-A9 Serial model : HT-A8,HT-H8 Standards Test procedure Test Date Date of Issue Test Result : FCC CFR47 Part 15 Section 15.247 : ANSI C63.10:2013 : December 01, 2019 to December 08, 2019 : December 12, 2019 : Pass This device described above has been tested by PTC, and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of PTC, this document may be altered or revised by PTC, personal only, and shall be noted in the revision of the document. Test Engineer: Leo Yang / Engineer Technical Manager: Chris Du / Manager Report No.: PTC19111304001E -FC01 Page 3 of 61 Contents Page 1 TEST RESULT CERTIFICATION ........................................................................................................................ 2 2 TEST SUMMARY ................................................................................................................................................... 5 3 GENERAL INFORMATION .................................................................................................................................. 6 3.1 GENERAL DESCRIPTION OF E.U.T............................................................................ 6 3.2 CHANNEL LIST ........................................................................................................... 7 3.3 TEST SITE ................................................................................................................ 10 4 EQUIPMENT DURING TEST ............................................................................................................................. 11 4.1 EQUIPMENTS LIST ................................................................................................... 11 4.2 MEASUREMENT UNCERTAINTY................................................................................ 13 4.3 DESCRIPTION OF SUPPORT UNITS .......................................................................... 14 5 CONDUCTED EMISSION ................................................................................................................................... 15 5.1 E.U.T. OPERATION ................................................................................................. 15 5.2 EUT SETUP ............................................................................................................. 15 5.3 TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION) ........................................ 16 5.4 MEASUREMENT PROCEDURE .................................................................................. 16 5.5 CONDUCTED EMISSION LIMIT .................................................................................. 16 5.6 MEASUREMENT DESCRIPTION ................................................................................ 16 5.7 CONDUCTED EMISSION TEST RESULT .................................................................... 16 6 RADIATED SPURIOUS EMISSIONS ............................................................................................................... 19 6.1 EUT OPERATION ..................................................................................................... 19 6.2 TEST SETUP ............................................................................................................ 20 6.3 SPECTRUM ANALYZER SETUP ................................................................................ 21 6.4 TEST PROCEDURE ................................................................................................... 22 6.5 SUMMARY OF TEST RESULTS ................................................................................. 23 7 BAND EDGE MEASUREMENT & UNWANTED EMISSIONS INTO RESTRICTED FREQUENCY BANDS ............................................................................................................................................................................ 28 7.1 TEST PROCEDURE ................................................................................................... 28 7.2 TEST RESULT .......................................................................................................... 29 8 6DB BANDWIDTH MEASUREMENT ............................................................................................................... 39 Report No.: PTC19111304001E -FC01 Page 4 of 61 8.1 TEST PROCEDURE ................................................................................................... 39 8.2 TEST RESULT .......................................................................................................... 39 9 MAXIMUM PEAK OUTPUT POWER ............................................................................................................... 46 9.1 TEST PROCEDURE ....................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Test Setup Conducted Emissions Radiated Spurious Emissions From Below 30MHz Test frequency from Above 1GHz

Contact Information

Applicant

Wang Wei(Quality Manager)
[email protected]+86-769-82612006Fax: +86-769-82612005

Test Firm

Precise Testing & Certification Co., LTD.Chris Du
[email protected]+86-769-38808222

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz17.80 mW
Confidentiality
Long Term
Grant Notes
Power listed is conducted. This device has a 20 MHz and 40 MHz bandwidth mode.

Other Applications from Dongguan Xintai Instrument Co.,Ltd.

Thermal Imagers - FCC ID 2AVBO-HT-S601 - Dongguan Xintai Instrument Co.,Ltd.
2AVBO-HT-S601

Thermal Imagers

Dec 02, 2025

Equipment Class

DTS - Digital Transmission System
2AVBO-HTW1

Thermal Imager Camera

Jan 24, 2024

Equipment Class

DTS - Digital Transmission System
Infrared thermal imager - FCC ID 2AVBO-HT-A2 - Dongguan Xintai Instrument Co.,Ltd.
2AVBO-HT-A2

Infrared thermal imager

Nov 22, 2023

Equipment Class

DTS - Digital Transmission System