FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Guangdong Bekey Technology Co.,Ltd./
  3. 2AVCH-AT1502

2AVCH-AT1502Atomi cell Phone UV sanitizer(Qi Charger)

Guangdong Bekey Technology Co.,Ltd.
Atomi cell Phone UV sanitizer(Qi Charger) - FCC ID 2AVCH-AT1502 - Guangdong Bekey Technology Co.,Ltd.
Click to zoom

Application Details

Equipment Class
8CC - Part 18 Consumer Device
Date of Grant
Jul 20, 2020
Application Purpose
Original Equipment
Date of Application
Jul 20, 2020
Equipment Note
Atomi cell Phone UV sanitizer(Qi Charger)
Frequency Range
0.11000000 - 0.20500000
Company
Guangdong Bekey Technology Co.,Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

FCC Statement This device complies with part 15 and part 18 of the FCC Rules. Operation is Subject To the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not explicitly approved by the party responsible for compliance could void the user's authority to operate this equipment. Note: this equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 and part 18 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and candidate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: · Reorient or relocate the receiving antenna. · Increase the separation between the equipment and receiver. · Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. · Consult the dealer or an experienced radio/TV technician for help. The equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. During the operation of device a distance of 15 cm surrounding the device and 20 cm above the top surface of the device must be respected. This device complies with Part 18 of the FCC Rules. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ● Increase the separation between the equipment and any other radio device. ● Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Cover Letter(s)

Guangdong Bekey Technology Co.,Ltd. Add: R building, Dong Yuan Reservoir Region Immigration base, Butterfly Lodge Ind District, Dongyuan, Heyuan city, GuangDong, China Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Dear Sir/Madam, We, Guangdong Bekey Technology Co.,Ltd. Hereby declares the following statement for FCC, PCB board, circuit, structure and internal of these model(s) are the same, Only model number is different for these model: Product Name: Atomi cell Phone UV sanitizer(Qi Charger) FCC ID: 2AVCH-AT1502 Model Number(s): AT1502, AT1524, AT1531 Sincerely, Name: Jiasheng Jiang/General Manager Company: Guangdong Bekey Technology Co.,Ltd. Address: R building, Dong Yuan Reservoir Region Immigration base, Butterfly Lodge Ind District, Dongyuan, Heyuan city, GuangDong, China Phone: 86-13554912019 Fax: 0760-23131376 E-Mail: [email protected]

Cover Letter(s)

CONFIDENTIALITY REQUEST for Certification Service in USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21046 <2020-07-16> TO WHOM IT MAY CONCERN Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we requests confidentiality for the following products: FCC ID Model name 2AVCH-AT1502 AT1502, AT1524, AT1531 For the product stated above, we request that the following information be held confidential; Exhibits Long-Term Confidentiality Short-Term Confidentiality Short-Term Confidentiality Days External Photos Internal Photos Block Diagram Schematics Test Setup Photos User’s Manual Parts List Tune Up Operational Descriptions The long-term confidentiality exhibits contain our trade secrets and proprietary information that could be of benefit to our competitors. The short-term confidentiality on the basis of ensuring that business sensitive information remains confidential until the actual marketing of our new device. If you have any questions, please feel free to contact me at the address shown below. Sincerely, Name: Jiasheng Jiang/General Manager Company: Guangdong Bekey Technology Co.,Ltd. Address: R building, Dong Yuan Reservoir Region Immigration base, Butterfly Lodge Ind District, Dongyuan, Heyuan city, GuangDong, China Phone: 86-13554912019 Fax: 0760-23131376 E-Mail: [email protected]

Cover Letter(s)

Guangdong Bekey Technology Co.,Ltd. Add: R building, Dong Yuan Reservoir Region Immigration base, Butterfly Lodge Ind District, Dongyuan, Heyuan city, GuangDong, China Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2020/07/16 To whom it may concern: We, Guangdong Bekey Technology Co.,Ltd.the undersigned, hereby authorize Eurofins Product Service GmbH to act on our behalf in all matters relating to applications for equipment authorization FCC ID: 2AVCH-AT1502 including the signing of all documents related to these matters. Any and all acts carried out by Eurofins Product Service GmbH on our behalf shall have the same effect as acts of our own. We also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Sincerely, Name: Jiasheng Jiang/General Manager Company: Guangdong Bekey Technology Co.,Ltd. Address: R building, Dong Yuan Reservoir Region Immigration base, Butterfly Lodge Ind District, Dongyuan, Heyuan city, GuangDong, China Phone: 86-13554912019 Fax: 0760-23131376 E-Mail: [email protected]

External Photos

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AVCH-AT1502 ________________________________________________________________________________ _________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 1 of 5 External Photos of the EUT Fig.1 Fig.2 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AVCH-AT1502 ________________________________________________________________________________ _________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 2 of 5 Fig.3 Fig.4 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AVCH-AT1502 ________________________________________________________________________________ _________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 3 of 5 Fig.5 Fig.6 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AVCH-AT1502 ________________________________________________________________________________ _________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 4 of 5 Fig.7 Fig.8 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AVCH-AT1502 ________________________________________________________________________________ _________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 5 of 5 Fig.9 Fig.10

ID Label/Location Info

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AVCH-AT1502 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 1 Label and Location Size: L: 3.5cm*W: 3.0cm Label Location Atomi cell Phone UV sanitizer(Qi Charger) Model No.: AT1502 FCC ID : 2AVCH-AT1502 This device complies with part 15 and part 18 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Made In China

Internal Photos

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AVCH-AT1502 ________________________________________________________________________________ _________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 1 of 6 Internal Photos of the EUT Fig.1 Fig.2 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AVCH-AT1502 ________________________________________________________________________________ _________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 2 of 6 Fig.3 Fig.4 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AVCH-AT1502 ________________________________________________________________________________ _________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 3 of 6 Fig.5 Fig.6 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AVCH-AT1502 ________________________________________________________________________________ _________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 4 of 6 Fig.7 Fig.8 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AVCH-AT1502 ________________________________________________________________________________ _________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 5 of 6 Fig.9 Fig.10 Coil Antenna SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AVCH-AT1502 ________________________________________________________________________________ _________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 6 of 6 Fig.11 Fig.12

RF Exposure Info

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AVCH-AT1502 ___________________________________________________________________________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 10 RF Exposure Evaluation Report 1. Product Information FCC ID: 2AVCH-AT1502 Number of tested samples 1 Sample number 200630107A Product Name Atomi cell Phone UV sanitizer(Qi Charger) Model Number AT1502 Power Supply Input: 5Vdc/3A, 9Vdc/2A, 12Vdc/1.5A; USB Output: 5Vdc/1A; Wireless Charge Pad :10W; Total Output: 15W Max Modulation Type CW (Continuous Wave) Frequency Range 110 KHz - 205 KHz Operation Frequency 128.0 KHz Antenna Type Coil Antenna Hardware version / Software version / Accessories Mobile phone Exposure category General population/uncontrolled environment EUT Type Production Unit Device Type Mobile Device 2. Evaluation Method Per KDB 680106 D01 Section 3. RF Exposure Requirements; 1) Consumer wireless power transfer devices approved under Part 18 in some cases have to demonstrate compliance with RF exposure requirements. The potential for exposure must be assessed according to the operating configurations of the wireless system and the exposure conditions of users and bystanders. RF exposure must be evaluated with the client device(s) being charged by the primary at maximum output power. The RF exposure requirements must be determined in conjunction with the device operating characteristics, according to the mobile and portable exposure requirements in Section 2.1091 and Section 2.1093 of the rules. SAR and MPE limits do not cover the frequency range for wireless power transfer applications which operate below 100 kHz and 300 kHz respectively; therefore, RF exposure compliance needs to be determined with respect to 1.1307 (c) and (d) of the FCC rules. 2) Based on the design and implementation of the power transfer application, it must be clearly identified if mobile or portable RF exposure conditions apply. Devices that are installed to provide separation of at least 20 cm from users and bystanders may qualify for mobile exposure conditions. For some conditions where users and bystanders may be exposed at closer than 20 cm, section 2.1091(d) (4) of the rules may apply. 3) For devices designed for typical desktop applications, such a wireless charging pads, RF exposure evaluation should be conducted assuming a user separation distance of 15 cm. E and H field strength measurements or numerical modeling may be used to demonstrate compliance. Measurements should be made from all sides and the top of the primary/client pair, with the 15 cm measured from the center of the probe(s) to the edge of the device. Emissions between 100 kHz to 300 kHz should be SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AVCH-AT1502 ___________________________________________________________________________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 2 of 10 assessed versus the limits at 300 kHz in Table 1 of Section 1.1310: 614 V/m and 1.63 A/m. A KDB inquiry is required to determine the applicable exposure limits below 100 kHz. 4) Portable exposure conditions from 100 kHz to 6 GHz are determined with respect to SAR requirements. Existing SAR systems and test procedures are generally intended for measurements above 100 MHz. While numerical modeling can be an alternative, the constraints of substantial computational resources at low frequencies could introduce further limitations. Under these circumstances, including operations below 100 kHz, the Commission may consider a combination of analytical analysis, field strength, radiated and conducted power measurements, in conjunction with some limited numerical modeling to assess compliance. 5) Depending on the operating frequency, existing SAR and MPE measurement procedures may be adapted to evaluate wireless power transfer devices for compliance with respect to mobile or portable exposure conditions. If the grantee or its test lab have any questions regarding RF exposure evaluation they should contact the FCC Laboratory with sufficient system operating configuration details to determine if RF exposure evaluation is necessary and, if required, how to apply specific test procedures. Below 100 MHz, when SAR testing is required and the device is operating at close proximity to persons, information on device design, implementation, operating configurations, exposure conditions of users and bystanders are needed to determine the evaluation and testing requirements. In addition, the influence of nearby objects may also need consideration according to the wireless power transfer system implementation; for example, the effects of placing the device, its coils or radiating elements on or near metallic surfaces 3. Evaluation Limit 3.1 Refer evaluation method ANSI C95.1–2019: IEEE Standard for Safety Levels with Respect to Human Exposure to Electric, Magnetic, and Electromagnetic Fields, 0 Hz to 300 GHz. FCC KDB publication 680106 D01 RF Exposure Wireless Charging Apps v03: RF Exposure Considerations for Low Power Consumer Wireless Power Transfer Applications FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1091: Radiofrequency radiation exposure evaluation: mobile devices FCC CFR 47 part 18.107:Indusial, Scientific, and Medical Equipment 3.2 Limit Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3-3.0 614 1.63 *100 6 3.0-30 1842/f 4.89/f *900/f 2 6 30-300 61.4 0.163 1.0 6 300-1,500 / / f/300 6 1,500-100,000 / / 5 6 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AVCH-AT1502 ___________________________________________________________________________ Thi…

Text truncated - open the document above for the full version.

Test Report

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AVCH-AT1502 Report No.: LCS200630107AEA This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 23 FCC TEST REPORT For Guangdong Bekey Technology Co., Ltd. Atomi cell Phone UV sanitizer(Qi Charger) Test Model: AT1502 Additional Model No.: Please Refer to Page 6 Prepared for : Guangdong Bekey Technology Co., Ltd. Address : R building, Dong Yuan Reservoir Region Immigration base, Butterfly Lodge Ind District, Dongyuan, Heyuan city, GuangDong, China Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Shajing Street, Baoan District, Shenzhen, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : July 03, 2020 Number of tested samples : 1 Sample number 200630107A Serial number : Prototype Date of Test : July 03, 2020 ~ July 10, 2020 Date of Report : July 13, 2020 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AVCH-AT1502 Report No.: LCS200630107AEA This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 2 of 23 FCC TEST REPORT FCC CFR 47 PART 18 Report Reference No. ................ : LCS200630107AEA Date Of Issue ................................. : July 13, 2020 Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd. Address .......................................... : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Shajing Street, Baoan District, Shenzhen, China Testing Location/ Procedure .......... : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name ......................... : Guangdong Bekey Technology Co., Ltd. Address .......................................... : R building, Dong Yuan Reservoir Region Immigration base, Butterfly Lodge Ind District, Dongyuan, Heyuan city, GuangDong, China Test Specification Standard ......................................... : FCC CFR 47 PART 18 Test Report Form No. .................... : LCSEMC-1.0 TRF Originator................................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF .................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test Item Description. .................. : Atomi cell Phone UV sanitizer(Qi Charger) Trade Mark ..................................... : Atomi Test Model ...................................... : AT1502 Power Supply ................................. : Please Refer To Page 6 Result ........................................... : Positive Compiled by: Supervised by: Approved by: Linda He/ Administrators Jin Wang/ Technique principal Gavin Liang/ Manager SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AVCH-AT1502 Report No.: LCS200630107AEA This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 3 of 23 FCC TEST REPORT Test Result Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Test Report No. : LCS200630107AEA July 13, 2020 Date of issue Test Model.............................. : AT1502 EUT......................................... : Atomi cell Phone UV sanitizer(Qi Charger) Applicant............................... : Guangdong Bekey Technology Co., Ltd. Address.................................. : R building, Dong Yuan Reservoir Region Immigration base, Butterfly Lodge Ind District, Dongyuan, Heyuan city, GuangDong, China Telephone............................... : / Fax.......................................... : / Manufacturer........................ : Guangdong Bekey Technology Co., Ltd. Address................................... : R building, Dong Yuan Reservoir Region Immigration base, Butterfly Lodge Ind District, Dongyuan, Heyuan city, GuangDong, China Telephone............................... : / Fax.......................................... : / Factory................................... : Guangdong Bekey Technology Co., Ltd. Address................................... : R building, Dong Yuan Reservoir Region Immigration base, Butterfly Lodge Ind District, Dongyuan, Heyuan city, GuangDong, China Telephone............................... : / Fax.......................................... : / SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AVCH-AT1502 Report No.: LCS200630107AEA This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 4 of 23 Revision History Revision Issue Date Revisions Revised By 000 July 13, 2020 Initial Issue Gavin Liang SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AVCH-AT1502 Report No.: LCS200630107AEA This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 5 of 23 TABLE OF CONTENTS 1. GENERAL INFORMATION ......................................................................................................... 6 1.1 Description of Device (EUT) .............................................................................................................. 6 1.2 Support equipment List ..................…

Text truncated - open the document above for the full version.

Test Setup Photos

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AVCH-AT1502 _______________________________________________________________________________________________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 2 Appendix A Photographs of Test Setup Conducted Emission-AC adapter charge mode Radiated Emission below 30MHz-AC adapter charge mode SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AVCH-AT1502 _______________________________________________________________________________________________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 2 of 2 Radiated Emission Below 1 GHz

Contact Information

Applicant

Jiasheng Jiang(General Manager)
[email protected]86-13554912019Fax: 33933291

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
1180.11 MHz - 0.205 MHz-
Confidentiality
Long Term

Other Applications from Guangdong Bekey Technology Co.,Ltd.

Shower Head Speaker - FCC ID 2AVCH-AT1817 - Guangdong Bekey Technology Co.,Ltd.
2AVCH-AT1817

Shower Head Speaker

Sep 18, 2022

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Shower Head Speaker - FCC ID 2AVCH-AT1490B - Guangdong Bekey Technology Co.,Ltd.
2AVCH-AT1490B

Shower Head Speaker

Aug 15, 2022

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Smart Outdoor Plug - FCC ID 2AVCH-AT2010 - Guangdong Bekey Technology Co.,Ltd.
2AVCH-AT2010

Smart Outdoor Plug

Jul 09, 2022

Equipment Class

DTS - Digital Transmission System
Vanity Mirror Speaker - FCC ID 2AVCH-AT1653 - Guangdong Bekey Technology Co.,Ltd.
2AVCH-AT1653

Vanity Mirror Speaker

Jun 05, 2022

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
wireless charging stand - FCC ID 2AVCH-STG-6761-KB - Guangdong Bekey Technology Co.,Ltd.
2AVCH-STG-6761-KB

wireless charging stand

Jul 25, 2021

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz