FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. SYBER SENSE IOT COMPANY LIMITED/
  3. 2AVDC-XOC01B2433

2AVDC-XOC01B2433EZ-BCam

SYBER SENSE IOT COMPANY LIMITED
EZ-BCam - FCC ID 2AVDC-XOC01B2433 - SYBER SENSE IOT COMPANY LIMITED
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
May 05, 2023
Application Purpose
Original Equipment
Date of Application
May 05, 2023
Equipment Note
EZ-BCam
Frequency Range
2412.00000000 - 2462.00000000
Company
SYBER SENSE IOT COMPANY LIMITED
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

ConfidentialforSyberSenseInternalUseOnly 1 EZ-BCamIndoor&OutdoorCameraUserGuide 1.Introduction AddsecuritytoyourhomeIndoororoutdoorwiththenewEZ-BCamBatteryCamera.Itcanbe BatteryorCablepoweredforindooruse,orpoweredwithanextensioncableforoutdooruse. Magneticbasesimplifiesthecamerainstallationprocesstojustaminute.Attachandpluginto hugyourseamlesslysecurevideolife. 2.Includedmaterials EZ-BCamCamera*1 Magneticbase*1 Type-CUSBCable*1 Fixingscrew*3 Expansiverubbersleeve*3 3.ProductAppearance ConfidentialforSyberSenseInternalUseOnly 2 4.ProductFeatures AmazonShadowandMQTTProtocol,fasterandsaferCommunicationwithserver. Themagneticmountallowseasyinstallationandadjustments Built-inrechargeablebatteryallowswire-freeandeasysetupalmostanywhere CompatiblewithD3panelsandthepanelisastheChimeofthecamera ReportsCameraonlineofflinestatus,lowbatteryandalleventstothepanel&mobileApp AIenhancedHumanbodydetectionandautolaunchthedeviceforrecording CustomMotionZoneplustheNNalgorithmtoreducethefalsetriggers Longbatterylife,aslongas4monthsandrechargeablewithcableorSolarPanel 5.ProductSpecification  ModelName: EZ-BCamV1(XOC01)  Videocompressionformat H.264+AACForVideoClipandVideostreaming  Memory: 2GBitEmbeddedDDR3  Networkprotocol P2PVideostreaming AWSIOTCameraconfiguration  Imagesensor: 1/2.9"FHD(1080P)sensor  NightVision B&WNightVision/850nm@5M Streamingresolution: HD(720P)/FHD(1080P) LED RGBcolorstatusLED  Videoframerate Variableframerate10-15fps  Chime  SecurityPanelasChime OS: DualOS(RTOS+Linux4.9) Storage: CloudStorage:AmazonKVSVideostorage  FieldofView: 124(H)*67(V)  Power 5V1ADCType-CUSB Battery:Built-in6500mAhbattery SolarPaneloptionalforcharging  WIFI/SubGRFradio WIFI:802.11b/g/n2.4GHz SubGRF:433MHz  OperationTemperature -20 ° C~50 ° C(Chargingfunction0 ° C~45 ° C)  MotionDetect Motionsensor/100°@5M AIHumandetectionalgorithmtoreducefalsetrigger  Waterproof IPX4 Video/AudioStreaming Full-duplextwowaycall Certification FCC/IC ConfidentialforSyberSenseInternalUseOnly 3 Warning: Thisdevicecomplieswithpart15oftheFCCRules.Operationissubjecttothefollowingtwo conditions:(1)Thisdevicemaynotcauseharmfulinterference,and(2)thisdevicemust acceptanyinterferencereceived,includinginterferencethatmaycauseundesiredoperation. FCCwarning: AnyChangesormodificationsnotexpresslyapprovedbythepartyresponsiblefor compliancecouldvoidtheuser'sauthoritytooperatetheequipment. Note:ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigital device,pursuanttopart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonable protectionagainstharmfulinterferenceinaresidentialinstallation.Thisequipmentgenerates usesandcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewith theinstructions,maycauseharmfulinterferencetoradiocommunications.However,thereis noguaranteethatinterferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoes causeharmfulinterferencetoradioortelevisionreception,whichcanbedeterminedby turningtheequipmentoffandon,theuserisencouragedtotrytocorrecttheinterferenceby oneormoreofthefollowingmeasures: -Reorientorrelocatethereceivingantenna. -Increasetheseparationbetweentheequipmentandreceiver. -Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiveris connected. -Consultthedealeroranexperiencedradio/TVtechnicianforhelp. ThisequipmentcomplieswithFCCradiationexposurelimitssetforthforanuncontrolled environment.Thisequipmentshouldbeinstalledandoperatedwithminimumdistance20cm betweentheradiator&yourbody. ThisdevicecomplieswithIndustryCanadalicence-exemptRSSstandard(s).Operationis subjecttothefollowingtwoconditions: (1)Thisdevicemaynotcauseinterference,and(2)Thisdevicemustacceptanyinterference, includinginterferencethatmaycauseundesiredoperationofthedevice. LeprésentappareilestconformeauxCNRd'IndustrieCanadaapplicablesauxappareilsradio exemptsdelicence. L'exploitationestautoriséeauxdeuxconditionssuivantes: (1)l'appareilnedoitpasproduiredebrouillage,et (2)l'utilisateurdel'appareildoitacceptertoutbrouillageradioélectriquesubi,mêmesile brouillageestsusceptibled'encompromettrelefonctionnement. ThisequipmentcomplieswithICRSS-102radiationexposurelimitssetforthforan uncontrolledenvironment.Thisequipmentshouldbeinstalledandoperatedwithminimum distance20cmbetweentheradiator&yourbody. Cetéquipementestconformeauxlimitesd'expositionauxrayonnementsICétabliespourun environnementnoncontrôlé.Cetéquipementdoitêtreinstalléetutiliséavecunminimumde 20cmdedistanceentrelasourcederayonnementetvotrecorps. Thedistancebetweenuserandproductsshouldbenolessthan20cm.

Attestation Statements

。 Sybe「senseloT company Limted 智天物耳带有限公司 Federal Communications Commission Autho「ization and Evaluation Division 7435 Oakland Mills Road Columbia , MD 21046 USA Date: 2/16/2023 Ref: Attestation Statements Part 2.911{d)(7) Filing FCC ID: {2AVDC-XOC01B2433) [SYBER SENSE IOT COMPANY LIMITED] {气he applicant ” ) cer tifies that, as of the date of the filing of the ap plication, Syber Sense Corp. is our designated U.S. agent for service of process fo「 the above re ferenced FCC ID. [SYBER SENSE IOT COMPANY LIMITED] accepts to maintain an agent for no less than one y ear after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Syber Sense Corp. accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: N ame: Sybe「 Sense Corp. Address: 1640 Millcreek Way, Millcreek Utah 84106 Contact Pe rson: Barrett Mo「gan Tel.: 8 01-450-6613 Email: s [email protected] FRN: 0033462821 Sincerely , [Insert applicant name] SYBER SENSE IOT COMPANY LIMITED (Applicant printed name) Simon Lee (Applicant signatu「eJ Rev 1 /26/2023 SYBERSENSE CORP Barrett Morgan

External Photos

ExternalPhotos EUTView1 EUTView2 EUTView3 EUTView4 EUTView5 EUTView6 EUTView7 EUTView8 EUTView9

Internal Photos

InternalPhotos EUTView8 433MHzAntenna EUTView9 EUTView10 i WiFiantenna EUTView11 EUTView12 EUTView13 EUTView14 EUTView15 EUTView16 EUTView17

RF Exposure Info

FCCID:2AVDC-XOC01B2433 RFEXPOSUREEVALUATION AccordingtoFCC1.1310:Thecriterialistedinthefollowingtableshallbeusedtoevaluatetheenvironmentimpactofhuman exposuretoradiofrequency(RF)Radiationasspecifiedin§1.1307(b) LimitsforMaximumPermissibleExposure(MPE) Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) Power Density(mW/cm 2 ) AverageTime (A)LimitsforOccupational/ControlExposures 300-1500----F/3006 1500-100000----56 (B)LimitsforGeneralPopulation/UncontrolExposures 300-1500----F/15006 1500-100000----130 11.1Friistransmissionformula:Pd=(Pout*G)\(4*pi*R 2 ) Where Pd=PowerdensityinmW/cm 2 Pout=outputpowertoantennainmW G=Numericgainoftheantennarelativetoisotropicantenna Pi=3.1416 R=distancebetweenobservationpointandcenteroftheradiatorincm PdthelimitofMPE,1mW/cm 2 ,Ifweknowthemaximumgainofthendtotalpowerinputtotheantenna,throughthecalculation,we willknowthedistancewheretheMPElimitisreached. RFExposureInformation:TheradiatedoutputpowerofthisdevicemeetsthelimitsofFCC/ICradiofrequencyexposurelimits.This deviceshouldbeoperatedwithaminimumseparationdistanceof20cm(8inches)betweentheequipmentandaperson'sbody. the433MHzdoesnoteffecttheoverallRFExposureandtherewasnoneedtoevaluateforthesebands. 11.2MeasurementResult Wifi2.4G-- Antennagain:2.75dBi modulation Channel Freq. (MHz) Max. Measured power (dBm) Tune-uppower (dBm) Maxtune-up power (dBm) Antenna Gain Numeric Evaluation result (mW/cm2) Powerdensity Limits (mW/cm2) 802.11b2462 10.12 10to12121.8840.00591 802.11g24627.817to991.8840.00301 802.11n2452 8.68 8to10101.8840.00371 433MHz modulation Channel Freq. (MHz) Max. Measured power (dBuV/m) Max. EIRP (dBm) Tune-uppower (dBm) Maxtune-up power (dBm) Evaluation result (mW/cm2) Powerdensity Limits (mW/cm2) ASK433.9788.31-6.92-7to-5-50.0000631 Note:EIRP[dBm]=E[dBμV/m]+20log(d[meters])-104.77 SimultaneousTransmission: Mode∑maxratiosLimitResults WIFI2.4G+433MHz0.0059631.0PASS

Test Report

Advanced Technology & Communications Test Report Model Information: Customer Rui Chuang Ke Model Name XOC01 Engineer Yang Guochang BAND 433MHz/2400MHz Date 2023/5/4 Antenna Version: Match Circuit: product picture: Measurement procedure 1. In the darkroom,put EUT on platform. 2. Use ROHDE&SCHWARZ CMW-500 to active test. 3. Use Agilent Technologies 5071B to passive test. 4. Record test data. Antenna Information: WIFI Antenna 433MHz Antenna Antenna Test The Information: WIFI433MHz S11/VSWR: WIFI S11/VSWR433MHz S11/VSWR WIFI Data of conduction: CHBANDTXRX WIFI B/11M 2412118.5-88 2437618.5-88 24621119-88 WIFI G/54M 2412117-75 2437617-75 24621117-75 WIFI N/MCS2 2412118-86 2437618-86 24621118-86 TX EVM 16 11 Requirements(EVM Limit) 802.11n802.11n802.11n MCS0/BPSK/1/2-8-8-9MCS0/BPSK/1/2802.11n(dB):-6/802.11ac(dB):-8 MCS1/QPSK/1/2-12-12-13MCS1/QPSK/1/2802.11n(dB):-11/802.11ac(dB):-12 MCS2/QPSK/3/4-15-15-16MCS2/QPSK/3/4802.11n(dB):-12/802.11ac(dB):-15 MCS3/16-QAM/1/2-17-18-19MCS3/16-QAM/1/2802.11n(dB):-15/802.11ac(dB):-18 MCS4/16-QAM/4/4-20-20-21MCS4/16-QAM/4/4802.11n(dB):-19/802.11ac(dB):-20 MCS5/64-QAM/2/3-22-23-23MCS5/64-QAM/2/3802.11n(dB):-21/802.11ac(dB):-23 MCS6/64-QAM/3/4-25-26-26MCS6/64-QAM/3/4802.11n(dB):-26/802.11ac(dB):-26 MCS7/64-QAM/3/4-28-28-29MCS7/64-QAM/3/4802.11n(dB):-28/802.11ac(dB):-28 X Y Z X Y Z X OTA: Active Test Results CHCHTRPTIS WIFI B/11M 2412115.02-84.03 2437615.37-85.09 24621116.03-85.11 WIFI G/54M 2412113.7-72.14 2437613.91-72.1 24621114.06-72.12 WIFI N/MCS2 2412114.84-82.55 2437615.1-83.06 24621115.05-83.01 Efficiency & Gain: WIFI433MHz Frequency/MHz Efficiency/% Gain.dBiFrequency/MHz Efficiency/% Gain.dBi 240051%1.76 42813%-5.18 241051%1.94 42913%-4.93 242052%2.07 43014%-4.66 243054%2.15 43114%-4.42 244056%2.67 43215%-4.24 245056%2.75 43315%-3.99 246056%2.60 43415%-4.02 247055%2.57 43515%-4.08 248054%2.33 43614%-4.04 249053%2.58 43714%-4.02 250054%2.48 43814%-3.99 WIFI Radiation Pattern: Theta=90 deg Phi=0 degPhi=90 deg 433MHz Radiation Pattern: Theta=90 deg Phi=0 degPhi=90 deg Antenna Summary 1.433MHz and WIFI test is OK; 2.433MHz Antenna Free air 130m-150m; 3.Please let me know if there is a change in the device.And if have any questions, please communicate promptly;

Test Report

ReportNo.ENS2212060136W00101RPage1of63Ver.1.0 TESTREPORT ProductName:EZ-BCam ModelNumber:EZ-BCamV1 FCCID:2AVDC-XOC01B2433 Preparedfor:SYBERSENSEIOTCOMPANYLIMITED Address:FLAT/RM10BLKA16/FHITECHINDUSTRIALCENTRE 5-21PAKTINPARSTREETTSUENWANHongKong China Preparedby:EMTEK(SHENZHEN)CO.,LTD. Address:Building69,MajialongIndustryZone,NanshanDistrict, Shenzhen,Guangdong,China Tel:(0755)26954280 Fax:(0755)26954282 ReportNumber:ENS2212060136W00101R Date(s)ofTests:December6,2022toJanuary13,2023 Dateofissue:January16,2023 $二维码$ ReportNo.ENS2212060136W00101RPage2of63Ver.1.0 TESTRESULTCERTIFICATION Applicant:SYBERSENSEIOTCOMPANYLIMITED Address: FLAT/RM10BLKA16/FHITECHINDUSTRIALCENTRE5-21PAKTINPAR STREETTSUENWANHongKongChina Manufacturer:SYBERSENSEIOTCOMPANYLIMITED Address: FLAT/RM10BLKA16/FHITECHINDUSTRIALCENTRE5-21PAKTINPAR STREETTSUENWANHongKongChina EUT:EZ-BCam ModelName:EZ-BCamV1 Trademark:N/A MeasurementProcedureUsed: APPLICABLESTANDARDS STANDARDTESTRESULT FCC47CFRPart2,SubpartJ FCC47CFRPart15,SubpartC PASS TheaboveequipmentwastestedbyEMTEK(SHENZHEN)CO.,LTD.Thetestdata,dataevaluation, testprocedures,andequipmentconfigurationsshowninthisreportweremadeinaccordancewiththe proceduresgiveninANSIC63.10(2013)andtheenergyemittedbythesampleEUTtestedasdescribed inthisreportisincompliancewiththerequirementsofFCCRulesPart2andPart15.247 Thetestresultsofthisreportrelateonlytothetestedsampleidentifiedinthisreport. DateofTest:December6,2022toJanuary13,2023 Preparedby: UnaYu//Editor Reviewer: JoeXia/Supervisor Approve&AuthorizedSigner: LisaWang/Manager ReportNo.ENS2212060136W00101RPage3of63Ver.1.0 ModifiedHistory VersionReportNo.RevisionDateSummary V1.0ENS2212060136W00101R/OriginalReport ReportNo.ENS2212060136W00101RPage4of63Ver.1.0 TABLEOFCONTENTS 1EUTTECHNICALDESCRIPTION....................................................................................................................5 2SUMMARYOFTESTRESULT...........................................................................................................................6 3TESTMETHODOLOGY......................................................................................................................................7 3.1GENERALDESCRIPTIONOFAPPLIEDSTANDARDS.............................................................................7 3.2MEASUREMENTEQUIPMENTUSED.........................................................................................................7 3.3DESCRIPTIONOFTESTMODES.................................................................................................................8 4FACILITIESANDACCREDITATIONS.............................................................................................................9 4.1FACILITIES......................................................................................................................................................9 4.2EQUIPMENT....................................................................................................................................................9 4.3LABORATORYACCREDITATIONSANDLISTINGS.................................................................................9 5TESTSYSTEMUNCERTAINTY......................................................................................................................10 6SETUPOFEQUIPMENTUNDERTEST.........................................................................................................11 6.1RADIOFREQUENCYTESTSETUP1.........................................................................................................11 6.2RADIOFREQUENCYTESTSETUP2.........................................................................................................11 6.3CONDUCTEDEMISSIONTESTSETUP.....................................................................................................14 6.4BLOCKDIAGRAMCONFIGURATIONOFTESTSYSTEM....................................................................15 6.5SUPPORTEQUIPMENT...............................................................................................................................15 7TESTREQUIREMENTS....................................................................................................................................16 7.1MINIMUM(6DB)OCCUPIEDBANDWIDTH............................................................................................16 7.2MAXIMUMPEAKCONDUCTEDOUTPUTPOWER...............................................................................23 7.3MAXIMUMPOWERSPECTRALDENSITY..............................................................................................31 7.4UNWANTEDSPURIOUSEMISSIONS........................................................................................................39 7.5RADIATEDEMISSION.................................................................................................................................46 7.6CONDUCTEDEMISSIONTEST..................................................................................................................59 7.7ANTENNAAPPLICATION...........................................................................................................................62 ReportNo.ENS2212060136W00101RPage5of63Ver.1.0 1EUTTECHNICALDESCRIPTION CharacteristicsDescription ProductEZ-BCam ModelNumberEZ-BCamV1 SampleNumber2# IEEE802.11WLAN ModeSupported 802.11b 802.11g 802.11n(20MHzchannelbandwidth) 802.11n(40MHzchannelbandwidth) Modulation DSSSwithDBPSK/DQPSK/CCKfor802.11b; OFDMwithBPSK/QPSK/16QAM/64QAMfor802.11g/n; OperatingFrequency Range 2412-2462MHzfor802.11b/g/n(HT20); 2422-2452MHzfor802.11n(HT40); NumberofChannels 11channelsfor802.11b/g/n(HT20); 7Channelsfor802.11n(HT40); TransmitPowerMax10.12dBm AntennaTypeInternalAntenna AntennaGain2.75dBi Powersupply: DC3.7Vfrominternalbattery DC5VfromUSBport Dataofreceived:December6,2022 ReportNo.ENS2212060136W00101RPage6of63Ver.1.0 2SUMMARYOFTESTRESULT FCCPartClauseTestParameterVerdictRemark 15.247(a)(2)DTS(6dB)B…

Text truncated - open the document above for the full version.

Test Report

ReportNo.ENS2212060136W00101RPage34of63Ver.1.0 11B_Ant1_2462 11G_Ant1_2412 ReportNo.ENS2212060136W00101RPage35of63Ver.1.0 11G_Ant1_2437 11G_Ant1_2462 ReportNo.ENS2212060136W00101RPage36of63Ver.1.0 11N20SISO_Ant1_2412 11N20SISO_Ant1_2437 ReportNo.ENS2212060136W00101RPage37of63Ver.1.0 11N20SISO_Ant1_2462 11N40SISO_Ant1_2422 ReportNo.ENS2212060136W00101RPage38of63Ver.1.0 11N40SISO_Ant1_2437 11N40SISO_Ant1_2452 ReportNo.ENS2212060136W00101RPage39of63Ver.1.0 7.4UNWANTEDSPURIOUSEMISSIONS 7.4.1ApplicableStandard AccordingtoFCCPart15.247(d)andKDB558074D0115.247MeasGuidancev05r02 7.4.2ConformanceLimit AccordingtoFCCPart15.247(d): Inany100kHzbandwidthoutsidethefrequencybandinwhichthespreadspectrumordigitally modulateddeviceisoperating,theRFpowerthatisproducedshallbeatleast20dBbelowthatin the100kHzbandwidthwithinthebandthatcontainsthehighestlevelofthedesiredpower,basedon eitheranRFconductedoraradiatedmeasurement,providedthatthetransmitterdemonstrates compliancewiththepeakconductedpowerlimits.Ifthetransmittercomplieswiththeconductedpower limitsbasedontheuseofroot-mean-squareaveragingoveratimeinterval,aspermittedundersection 5.4(d),theattenuationrequiredshallbe30dBinsteadof20dB.Attenuationbelowthegeneralfield strengthlimitsspecifiedinRSS-Genisnotrequired. 7.4.3TestConfiguration Testaccordingtoclause6.1radiofrequencytestsetup 7.4.4TestProcedure Thetransmitteroutput(antennaport)wasconnectedtothespectrumanalyzer Referencelevelmeasurement Establishareferencelevelbyusingthefollowingprocedure: SetinstrumentcenterfrequencytoDTSchannelcenterfrequency. Setthespanto≥1.5timestheDTSbandwidth. SettheRBW=100kHz. SettheVBW≥3xRBW. SetDetector=peak. SetSweeptime=autocouple. SetTracemode=maxhold. Allowtracetofullystabilize. UsethepeakmarkerfunctiontodeterminethemaximumPSDlevel. NotethatthechannelfoundtocontainthemaximumPSDlevelcanbeusedtoestablishthereference level. Emissionlevelmeasurement Setthecenterfrequencyandspantoencompassfrequencyrangetobemeasured. SettheRBW=100kHz. SettheVBW=300kHz. SetDetector=peak Sweeptime=autocouple. Tracemode=maxhold. Allowtracetofullystabilize. Usethepeakmarkerfunctiontodeterminethemaximumamplitudelevel. Ensurethattheamplitudeofallunwantedemissionsoutsideoftheauthorizedfrequencyband(excluding restrictedfrequencybands)areattenuatedbyatleasttheminimumrequirements.Reportthethree highestemissionsrelativetothelimit. 7.4.5TestResults ReportNo.ENS2212060136W00101RPage40of63Ver.1.0 Allmodulationmodesweretested,andtheworstdataisshowninthetablebelow: TestModel PSD(PowerSpectralDensity)RBW=100kHz 802.11b802.11g802.11n(HT20)802.11n(HT40) Channel1:2412MHzChannel3:2422MHz TestModel UnwantedEmissionsinnon-restrictedfrequencybands 802.11b802.11g802.11n(HT20)802.11n(HT40) Channel1:2412MHzChannel3:2422MHz ReportNo.ENS2212060136W00101RPage41of63Ver.1.0 TestModel Bandedge 802.11b802.11g802.11n(HT20)802.11n(HT40) Channel1:2412MHzChannel3:2422MHz ReportNo.ENS2212060136W00101RPage42of63Ver.1.0 TestModel PSD(PowerSpectralDensity)RBW=100kHz 802.11b802.11g802.11n(HT20)802.11n(HT40) Channel6:2437MHz ReportNo.ENS2212060136W00101RPage43of63Ver.1.0 TestModel UnwantedEmissionsInNon-RestrictedFrequencyBands 802.11b802.11g802.11n(HT20)802.11n(HT40) Channel6:2437MHz ReportNo.ENS2212060136W00101RPage44of63Ver.1.0 TestModel PSD(PowerSpectralDensity)RBW=100kHz 802.11b802.11g802.11n(HT20)802.11n(HT40) Channel11:2462MHzChannel9:2452MHz TestModel UnwantedEmissionsInNon-RestrictedFrequencyBands 802.11b802.11g802.11n(HT20)802.11n(HT40) Channel11:2462MHzChannel9:2452MHz ReportNo.ENS2212060136W00101RPage45of63Ver.1.0 TestModel Bandedge 802.11b802.11g802.11n(HT20)802.11n(HT40) Channel11:2462MHzChannel9:2452MHz ReportNo.ENS2212060136W00101RPage46of63Ver.1.0 7.5RADIATEDEMISSION 7.5.1ApplicableStandard AccordingtoFCCPart15.247(d)and15.209andKDB558074D0115.247MeasGuidancev05r02 7.5.2ConformanceLimit AccordingtoFCCPart15.247(d):radiatedemissionswhichfallintherestrictedbands,asdefinedin §15.205(a),mustalsocomplywiththeradiatedemissionlimitsspecifiedin§15.209(a)(see§15.205(c)). AccordingtoFCCPart15.205,Restrictedbands MHzMHzMHzGHz 0.090-0.11016.42-16.423399.9-4104.5-5.15 10.495-0.50516.69475-16.69525608-6145.35-5.46 2.1735-2.190516.80425-16.80475960-12407.25-7.75 4.125-4.12825.5-25.671300-14278.025-8.5 4.17725-4.1777537.5-38.251435-1626.59.0-9.2 4.20725-4.2077573-74.61645.5-1646.59.3-9.5 6.215-6.21874.8-75.21660-171010.6-12.7 6.26775-6.26825123-1382200-230014.47-14.5 8.291-8.294149.9-150.052310-239015.35-16.2 8.362-8.366156.52475-156.525252483.5-250017.7-21.4 8.37625-8.38675156.7-156.92690-290022.01-23.12 8.41425-8.41475162.0125-167.173260-326723.6-24.0 12.29-12.293167.72-173.23332-333931.2-31.8 12.51975-12.52025240-2853345.8-335836.43-36.5 12.57675-12.57725322-335.43600-4400(2) 13.36-13.41 AccordingtoFCCPart15.205thelevelofanytransmitterspuriousemissioninRestrictedbandsshallnot exceedtheleveloftheemissionspecifiedinthefollowingtable Restricted Frequency(MHz) FieldStrength(μV/m)FieldStrength (dBμV/m) Measurement Distance 0.009-0.4902400/F(KHz)20log(uV/m)300 0.490-1.70524000/F(KHz)20log(uV/m)30 1.705-303029.530 30-88100403 88-21615043.53 216-960200463 Above960500543 7.5.3TestConfiguration Testaccordingtoclause6.2radiofrequencytestsetup 7.5.4TestProcedure ThistestisrequiredforanyspuriousemissionthatfallsinaRestrictedBand,asdefinedinSection 15.205.Itmustbeperformedwiththehighestgainofeachtypeofantennaproposedforusewiththe EUT.Usethefollowingspectrumanalyzersettings: ForAbove1GHz: TheEUTwasplacedonaturntablewhichis1.5mabovegroundplane. MaximumprocedurewasperformedonthehighestemissionstoensureEUTcompliance. Span=wideenoughtofullycapturetheemissionbeingmeasured RBW=1MHz VBW  RBW Sweep=auto Detectorfunction=peak Trace=maxhold ForBelow1GHz: ReportNo.ENS2212060136W00101RPage47of63Ver.1.0 TheEUTwasplacedonaturntablewhichis0.8mabovegroundplane. MaximumprocedurewasperformedonthehighestemissionstoensureEUTcompliance. Span=wideenoughtofullycapturetheemissionbeingmeasured RBW=100kHzfor VBW  RBW Sweep=auto Detectorfunction=peak Trace=maxhold ForBelo…

Text truncated - open the document above for the full version.

Test Setup Photos

Setupphotos CONDUCTEDEMISSIONTEST RADIATEDEMISSIONTEST

Contact Information

Applicant

Simon Lee(CEO)
[email protected]90276048Fax: 852-27575199

Test Firm

EMTEK (Shenzhen) Co., Ltd.Lisa Wang
[email protected]8675526954280

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz10.00 mW
Confidentiality
Long Term
Grant Notes
Power listed is conducted. Device must be installed and operated to provide a separation distance of at least 20cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20, and 40 MHz bandwidth modes.

Other Applications from SYBER SENSE IOT COMPANY LIMITED

SS Wall Mount Button - FCC ID 2AVDC-WM01E1433 - SYBER SENSE IOT COMPANY LIMITED
2AVDC-WM01E1433

SS Wall Mount Button

Apr 16, 2023

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
EZ-BBell - FCC ID 2AVDC-XDC03B2433 - SYBER SENSE IOT COMPANY LIMITED
2AVDC-XDC03B2433

EZ-BBell

Apr 12, 2023

Equipment Class

DTS - Digital Transmission System
XPK-01 - FCC ID 2AVDC-XPK-201 - SYBER SENSE IOT COMPANY LIMITED
2AVDC-XPK-201

XPK-01

Apr 27, 2020

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter