FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Gardyn Inc/
  3. 2AVEEGHA02

2AVEEGHA02Gardyn Home

Gardyn Inc
Gardyn Home - FCC ID 2AVEEGHA02 - Gardyn Inc
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Nov 24, 2022
Application Purpose
Original Equipment
Date of Application
Nov 22, 2022
Equipment Note
Gardyn Home
Frequency Range
2412.00000000 - 2462.00000000
Company
Gardyn Inc
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Owner’s manual Manuel utilisateur HOME 2 HOME - OWNER’S MANUAL S AFETY INSTRUCTIONS Read all instructions before installing and operating your device. It is the owner's responsibility to ensure that all users are aware of all warnings and precautions. When using an electrical unit, basic precautions should always be followed, including the following: DANGER – To reduce the risk of electric shock: ● Always unplug the Gardyn Home from the electrical outlet before cleaning or performing maintenance operations. WARNING – To reduce the risk of burns, fire, electric shock, or injury to persons: ● Unplug from outlet before assembling or disassembling parts. ● To disconnect, place the power switch located behind the unit in OFF position, then remove plug from outlet. ● Use this unit only for its intended use as described in these instructions. Use only original parts from the manufacturer. Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. ● If a part is damaged or worn, contact the manufacturer immediately to order the appropriate spare part, then replace the damaged or worn parts. Do not use the unit until the repair is performed. ● Never opera te this unit if it is incomplete, has a damaged cord or plug, is not working properly, has been dropped or damaged, or has been dropped into water. ● Do not try to unscrew any part of the unit or open it using force. ● Keep the cord away from any heat source. ● Never drop or insert any object into any unit opening. ● This unit is for indoor use only. Do not store it outdoors, near water, or in high humidity levels. ● Do not operate where aerosol (spray) products are being used or where oxygen is being administered. ● Do not immerse the unit, cord, or plug in water or any other liquid. ● Make sure there is no water close to the power supply or its cord. ● Never pour water on the lights, on the power supply, on the cord, or on the power outlet. ● Thi s appliance is not inte nded for use by children or persons with reduced physical, sensory or mental capabilities or lack of experience or knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety and understand the hazards involved. ● Cleaning and user maintenance shall not be performed by children without supervision. ● Close supervi sion is necessary when this unit is used by, or near children, invalids, or disabled persons. ● Electrical wiring shall be in accordance with local regulation. ● Make sure that the product is connected to an outlet having the same configuration as the device’s plug. No adapter should be used with this product. Notice & Additional safeguards ● Do not look directly int o the lights when ON. ● The device should be used indoors exclusively, in a dry and temperate environment (65 ° F-80 ° F / 18 ° C – 27 ° C). ● Make sure all packaging material or promotional labels have been removed and safely discarded before using the unit for the first time. ● To operate, the device needs to be connected to WiFi. ● No water connection is necessary. ● No sunli ght is necessary. ● U se the lateral lid locks to secure the lid on the water tank before powering the device. ● Do not touch the lights' enclosure: it can get warm due to the heat dissipated by the lights. ● An opening on the surface of the wooden board makes it possible to fill the tank and add nutrients. When filling the water tank, make sure that the water level stays below the bottom ed ge of the circular open ing. ● Any water that may spill on the device should be promptly wiped off. ● The removable wooden cap, which covers the hole to pour water onto the tank, should remain in position when the device is ON to avoid the development of biofilm in the device. ● Always make sure the water pump is in the lowered position inside the water tank when the device is ON. Safety instructions HOME - MANUEL UTILISATEUR 3 ● When pulling yPods out of the column, use the sleeve provided by the manufacturer to avoid any water spillage. Do not pull the yPods from the column when the pump is working or within the 5 minutes following irrigation by the water pump. ● Do not touch or try to manually adjust the cameras. Cameras can be disabled by adjusting the settings in the App. ● Used electric or electrical product s should not be disposed of with general household waste. Please recycle where facilities exist. Check with your local authority for recycling advice. Disposing of this product correctly will help save valuable resources and prevent any potential negative effects on human health and the environment, which could otherwise arise from inappropriate waste handling. ● The plants growing on the dev ice are of the user's sole responsibility. Do not add any spray or liquid or chemical on the plants. Do not eat any plant if it presents any risk, including food sensitivities and/or allergies. Typically, only some parts of the plants are edible. Non-edible parts should not be consumed. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, purs uant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference w ill not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ● Reorient or relocate the receiving antenna. ● Increase the separation between the equipment and receiv …

Text truncated - open the document above for the full version.

Cover Letter(s)

Gardyn Inc Authority letter FCC Date: 7/29/2022 TO: Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Regarding: FCC ID: 2AVEEGHA02 To whom it may concern: We, the undersigned, hereby authorize SGS-CSTC Standards Technical Services Co., Ltd. (SGS) Guangzhou branch and Kobe Jian in SGS-CSTC Standards Technical Services Co., Ltd. (SGS) Guangzhou branch to act on our behalf in all manners relating to application for equipment authorization with respect to the FCC ID above, including signing of all documents relating to these matters. Any and all acts carried out by the agent on our behalf shall have the same effect as acts of our own. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). Where our agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by SGS North America, Inc., still resides with Gardyn Inc. This authorization is valid until further written notice from the applicant. Name (Printed): Francois-Xavier Rouxel Title: CEO Signature: On behalf of Company: Gardyn Inc

Cover Letter(s)

Gardyn Inc Confidential letter FCC To: SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia United States From: Gardyn Inc 8120 Woodmont Avenue Suite #640 Bethesda, Maryland, 20614, United States Regarding: Confidentiality Request regarding application for FCC ID: 2AVEEGHA02 LONG TERM CONFIDENTIALITY Pursuant to 47 CFR Section 0.459 and 0.457 of the commission’s rules, the applicant hereby request confidential treatment of the documents listed below, associated with the certification application referenced above. Schematic(s) Block Diagrams Operational Descriptions The documents above contain proprietary information not released to the public. Public disclosure of this information may prove harmful to the business of the applicant. Sincerely, Name (Printed): Francois-Xavier Rouxel Title: CEO Signature: On behalf of Company: Gardyn Inc

Cover Letter(s)

SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia 30024 United States Applicant Declaration Applicant Declaration Letter Applicant Legal Business Name Gardyn Inc Address 8120 Woodmont Avenue Suite #640Bethesda, 20614, Maryland, United States Grantee Code 2AVEE FCC ID 2AVEEGHA02 Authorized Contact Name Francois-Xavier Rouxel Contact Email [email protected] Contact Phone 3013324462 I, the undersigned, certify that I am an authorized signatory for the Applicant and therefore declare; a) in accordance with 47CFR2.911(d), all of the statements herein and the exhibits attached hereto are true and correct to the best of my knowledge and belief. b) in accepting a Grant of Equipment Authorization issued by a TCB, under the authority of the FCC, as a result of the representations made in this application, the Applicant is responsible for: (1) labeling the equipment with the exact FCC ID as specified in this application, (2) compliance statement labeling pursuant to the applicable rules, (3) compliance of the equipment with the applicable technical rules, c) if the Applicant is not the actual manufacturer of the equipment, appropriate arrangements have been made with the manufacturer to ensure that production units of this equipment will continue to comply with the FCC’s technical requirements. d) in accordance with 47 CFR 2.909 and KDB394321, the Applicant has read, understood and agrees to accept that they are the responsible party and agree to abide by their responsibilities as specified under 47 CFR 2.909 and KDB394321. e) in accordance with ISO17065, FCC KDB641163, FCC KDB610077, KDB394321 and RSP-100, the Applicant has read, understood, accepts and agrees to abide by the post market surveillance requirements. (1) the Applicant understands, accepts and agrees that a sample may be requested for surveillance testing. (2) the Applicant shall make provisions to always have a production sample available upon request by SGS, FCC and/or ISED. (3) the Applicant shall, upon request by SGS, at the Applicant’s expense, provide a production sample of the requested product to SGS, FCC and/or ISED as instructed. The sample shall include all support devices, cables, software, accessories or other hardware or software required for evaluation, review, certification and audit surveillance of products certified by SGS. f) neither the Applicant nor any party to the application is subject to a denial of Federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. §862 because of a conviction for possession or distribution of a controlled substance. See 47CFR 1.2002(b) for the definition of a “party” for these purposes. g) the Applicant has read, understood, accepts and agrees to abide by the SGS North America, Inc.(TCB) terms and conditions. Link to CFRs: https://www.fcc.gov/wireless/bureau-divisions/technologies-systems-and-innovation-division/rules-regulations-title-47 Link to KDBs: https://apps.fcc.gov/oetcf/kdb/index.cfm Link to RSP-100: https://www.ic.gc.ca/eic/site/smt-gst.nsf/eng/sf01130.html Applicant Signature: Date: 7/29/2022 Print Name: Francois-Xavier Rouxel Title: CEO *NOTE: This declaration cannot be signed by an Agent, it shall be signed by an authorized person listed in the FCC database Applicant Declaration Rev:0.0

External Photos

SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-02 Rev 1.0 Page: 1 of 7 Appendix - External Photos for GZCR2206000847LM Test Model No.: GH-A02 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-02 Rev 1.0 Page: 2 of 7 EUT Constructional Details (EUT Photos) SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-02 Rev 1.0 Page: 3 of 7 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-02 Rev 1.0 Page: 4 of 7 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-02 Rev 1.0 Page: 5 of 7 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-02 Rev 1.0 Page: 6 of 7 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-02 Rev 1.0 Page: 7 of 7

ID Label/Location Info

Location:

Internal Photos

SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-03 Rev 1.0 Page: 1 of 8 Appendix - Internal Photos for GZCR2206000847LM Test Model No.: GH-A02 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-03 Rev 1.0 Page: 2 of 8 EUT Constructional Details (EUT Photos) SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-03 Rev 1.0 Page: 3 of 8 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-03 Rev 1.0 Page: 4 of 8 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-03 Rev 1.0 Page: 5 of 8 RF ANT SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-03 Rev 1.0 Page: 6 of 8 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-03 Rev 1.0 Page: 7 of 8 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-03 Rev 1.0 Page: 8 of 8

RF Exposure Info

SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-03 Rev 1.0 Report No.: GZCR220600084703 Page: 1 of 9 FCC ID: 2AVEEGHA02 Kobe Jian EMC Laboratory Manager RF EXPOSURE EVALUATION REPORT Application No.: GZCR2206000847LM Applicant:Gardyn inc Address of Applicant:8120 Woodmont Avenue, Suite #640 Bethesda, MD 20814, U.S.A. Manufacturer:Gardyn inc Address of Manufacturer:8120 Woodmont Avenue, Suite #640 Bethesda, MD 20814, U.S.A. Factory:VS Industry Berhad Address of Factory:No 161-162 Jalan Murni 12, Taman Perindustrian Murni, Senai, Johor, 81400, Malaysia Equipment Under Test (EUT): EUT Name:Gardyn Home Model No.: GH-A02, GH A02   Please refer to section 2 of this report which indicates which item was actually tested and which were electrically identical. Standard(s) : 47 CFR Part 1.1310 KDB447498D01 General RF Exposure Guidance v06 Date of Receipt: 2022-06-28 Date of Evaluation: 2022-07-04 to 2022-07-22 Date of Issue: 2022-09-08 Evaluation Result: Pass* * In the configuration evaluated, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Report No.: GZCR220600084703 EMC-TRF-03 Rev 1.0 Page: 2 of 9 Revision Record VersionReport No.DateRemark 01GZCR2206000847032022-09-08Original Authorized for issue by: Kevin Zhang/Project Engineer Vico Cui/Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Report No.: GZCR220600084703 EMC-TRF-03 Rev 1.0 Page: 3 of 9 2Evaluation Summary ItemStandardMethodRequirementResult RF Exposure KDB447498D01 General RF Exposure Guidance v06 KDB447498D01 General RF Exposure Guidance v06 47 CFR Part 1.1310Pass Note: E.U.T./EUT means Equipment Under Test. Pass means the test result passed the test standard requirement, please find the detailed decision rule in the report relative section.  Declaration of EUT Family Grouping: Model No.: GH-A02, GH A02 According to the declaration from the applicant, the electrical circuit design, layout, components used and internal wiring were identical for all models, with only difference on model name and outer decoration. Therefore only one model GH-A02 was tested in this report. SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Report No.: GZCR220600084703 EMC-TRF-03 Rev 1.0 Page: 4 of 9 3Contents Page 1Cover Page...............................................................................................................................................1 2Evaluation Summary................................................................................................................................3 3Contents....................................................................................................................................................4 4General Information.................................................................................................................................5 4.1Details of E.U.T.................................................................................................................................5 4.2Evaluating Location...........................................................................................................................5 4.3Facility...............................................................................................................................................6 4.4Deviation from Standards..................................................................................................................6 4.5Abnormalities from Standard Conditions...........................................................................................6 5Technical Requirements Specification..................................................................................................7 5.1General Description of Applied Standards........................................................................................7 5.2RF Exposure Evaluation....................................................................................................................7 5.2.1Limit & Test Method......................................................................................................................7 5.2.2Conclusion....................................................................................................................................8 6EUT Constructional Details (EUT Photos).............................................................................................9 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Report No.: GZCR220600084703 EMC-TRF-03 Rev 1.0 Page: 5 of 9 4General Information 4.1Details of E.U.T. Power Supply:DC 24 V powered by AC/DC adapter as below: Model: FY1802407500 Input: AC 100-240 V, 50/60 Hz, 2.6 A Max Output: DC 24 V, 7500 mA Rated Power:180W Cable:DC input ports for main unit For AC/DC adapter: AC mains (unshielded, 0.8 m) DC output cables (unshielded, 1.5m) For BT Antenna Gain1 dBi Antenna TypePCB Antenna Channel Spacing2MHz Modulation TypeGFSK Number of Channels40 Operation Frequency2402MHz to 2480MHz For Wi-Fi Antenna Gain1 dBi Antenna TypePCB Antenna Channel Spacing5MHz Modulation Type802.11b: DSSS (CCK, DQPSK, DBPSK) 802.11g/n: OFDM (64QAM, 16QAM, QPSK, BPSK) Number of Channels802.11b/g/n(HT20):11 Operation Frequency802.11b/g/n(HT20): 2412MHz to 2462MHz 4.2Evaluating Location All tests were performed at: SGS-CSTC Standards Technical Services Co., Ltd., Guangzhou Branch EMC Laboratory, 198 Kezhu Road, Scientech Park, Guangzhou Economic & Technology Development District, Guangzhou, China 510663 Tel: +86 20 82155555Fax: +86 20 82075059 No tests were sub-contracted. SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Report No.: GZCR220600084703 EMC-TRF-03 Rev 1.0 Page: 6 of 9 4.3Facility The facility is recognized, certified, or accredited by the following organizations: ● NVLAP (Lab Code: 200611-0) SGS-CSTC Standards Technical Services Co., Ltd., Guangzhou EMC Laborat…

Text truncated - open the document above for the full version.

Test Report

SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-01 Rev 1.0 Report No.: GZCR220600084702 Page: 1 of 116 FCC ID: 2AVEEGHA02 Kobe Jian EMC Laboratory Manager TEST REPORT Application No.: GZCR2206000847LM Applicant: Gardyn inc Address of Applicant: 8120 Woodmont Avenue, Suite #640 Bethesda, MD 20814, U.S.A. Manufacturer: Gardyn inc Address of Manufacturer: 8120 Woodmont Avenue, Suite #640 Bethesda, MD 20814, U.S.A. Factory: VS Industry Berhad Address of Factory: No 161-162 Jalan Murni 12, Taman Perindustrian Murni, Senai, Johor, 81400, Malaysia Equipment Under Test (EUT): EUT Name: Gardyn Home Model No.: GH-A02, GH A02   Please refer to section 2 of this report which indicates which item was actually tested and which were electrically identical. Standard(s) : 47 CFR Part 15, Subpart C 15.247 Date of Receipt: 2022-06-28 Date of Test: 2022-07-04 to 2022-07-22 Date of Issue: 2022-09-08 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. EMC-TRF-01 Rev 1.0 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Report No.: GZCR220600084702 Page: 2 of 116 Revision Record Version Report No. Date Remark 01 GZCR220600084702 2022-09-08 Original Authorized for issue by: Kevin Zhang/Project Engineer Vico Cui/Reviewer EMC-TRF-01 Rev 1.0 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Report No.: GZCR220600084702 Page: 3 of 116 2 Test Summary Radio Spectrum Technical Requirement Item Standard Method Requirement Result Antenna Requirement 47 CFR Part 15, Subpart C 15.247 N/A 47 CFR Part 15, Subpart C 15.203 & 15.247(b)(4) Pass Radio Spectrum Matter Part Item Standard Method Requirement Result Conducted Emissions at AC Power Line (150kHz-30MHz) 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 6.2 47 CFR Part 15, Subpart C 15.207 Pass** Conducted Peak Output Power ANSI C63.10 (2013) Section 11.9.2 47 CFR Part 15, Subpart C 15.247(b)(3) Pass Minimum 6dB Bandwidth ANSI C63.10 (2013) Section 11.8.1 47 CFR Part 15, Subpart C 15.247a(2) Pass Power Spectrum Density ANSI C63.10 (2013) Section 11.10.2 47 CFR Part 15, Subpart C 15.247(e) Pass Conducted Band Edges Measurement ANSI C63.10 (2013) Section 11.13.3.2 47 CFR Part 15, Subpart C 15.247(d) Pass Conducted Spurious Emissions ANSI C63.10 (2013) Section 11.11 47 CFR Part 15, Subpart C 15.247(d) Pass Radiated Emissions which fall in the restricted bands ANSI C63.10 (2013) Section 6.10.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions Below 1GHz ANSI C63.10 (2013) Section 6.4,6.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions Above 1GHz ANSI C63.10 (2013) Section 6.6 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Note: E.U.T./EUT means Equipment Under Test. Pass means the test result passed the test standard requirement, please find the detailed decision rule in the report relative section. **: The EUT passed Conducted Emissions at AC Power Line (150kHz-30MHz) test after modifications.  Declaration of EUT Family Grouping: Model No.: GH-A02, GH A02 According to the declaration from the applicant, the electrical circuit design, layout, components used and internal wiring were identical for all models, with only difference on model name and outer decoration. Therefore only one model GH-A02 was tested in this report. EMC-TRF-01 Rev 1.0 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Report No.: GZCR220600084702 Page: 4 of 116 3 Contents Page 1 Cover Page ................................................................................................................................................ 1 2 Test Summary ........................................................................................................................................... 3 3 Contents .................................................................................................................................................... 4 4 General Information .................................................................................................................................. 6 4.1 Details of E.U.T. ................................................................................................................................. 6 4.2 Description of Support Units .............................................................................................................. 6 4.3 Measurement Uncertainty .................................................................................................................. 7 4.4 Test Location ...................................................................................................................................... 7 4.5 Test Facility ........................................................................................................................................ 8 4.6 Deviation from Standards ................................................................................................................... 8 4.7 Abnormalities from Standard Conditions ........................................................................................... 8 5 Equipment List .......................................................................................................................................... 9 6 Radio Spectrum Technical Requirement ............................................................................................. 12 6.1 Antenna Requirement ...................................................................................................................... 12 6.1.1 Test Requirement: ....................................................................................................................... 12 6.1.2 Conclusion ................................................................................................................................... 12 7 Radio Spectrum Matter Test Results ........................................…

Text truncated - open the document above for the full version.

Test Report

EMC-TRF-01 Rev 1.0 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Report No.: GZCR220600084702 Page: 83 of 116 1M_LCH_2402MHz_Ant1_NTNV 1M_MCH_2440MHz_Ant1_NTNV EMC-TRF-01 Rev 1.0 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Report No.: GZCR220600084702 Page: 84 of 116 1M_HCH_2480MHz_Ant1_NTNV 1M_HCH_2480MHz_Ant1_NTNV EMC-TRF-01 Rev 1.0 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Report No.: GZCR220600084702 Page: 85 of 116 For Wi-Fi 1. Duty Cycle 1.1 Ant1 1.1.1 Test Result Ant1 Mode TX Type Frequency (MHz) T_on (ms) Period (ms) Duty Cycle (%) Duty Cycle Correction Factor (dB) Max. DC Variation (%) 802.11b SISO 2412 12.420 12.550 98.96 0.05 0.03 2437 12.417 12.547 98.96 0.05 0.03 2462 12.417 12.547 98.96 0.05 0.03 802.11g SISO 2412 2.064 2.194 94.07 0.27 0.03 2437 2.064 2.194 94.07 0.27 0.03 2462 2.064 2.195 94.03 0.27 0.04 802.11n (HT20) SISO 2412 1.920 2.050 93.66 0.28 0.04 2437 1.921 2.050 93.71 0.28 0.00 2462 1.920 2.050 93.66 0.28 0.04 1.1.2 Test Graph 802.11b_LCH_2412MHz_Ant1 (SISO)_NTNV EMC-TRF-01 Rev 1.0 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Report No.: GZCR220600084702 Page: 86 of 116 802.11b_MCH_2437MHz_Ant1 (SISO)_NTNV 802.11b_HCH_2462MHz_Ant1 (SISO)_NTNV EMC-TRF-01 Rev 1.0 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Report No.: GZCR220600084702 Page: 87 of 116 802.11g_LCH_2412MHz_Ant1 (SISO)_NTNV 802.11g_MCH_2437MHz_Ant1 (SISO)_NTNV EMC-TRF-01 Rev 1.0 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Report No.: GZCR220600084702 Page: 88 of 116 802.11g_HCH_2462MHz_Ant1 (SISO)_NTNV 802.11n(HT20)_LCH_2412MHz_Ant1 (SISO)_NTNV EMC-TRF-01 Rev 1.0 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Report No.: GZCR220600084702 Page: 89 of 116 802.11n(HT20)_MCH_2437MHz_Ant1 (SISO)_NTNV 802.11n(HT20)_HCH_2462MHz_Ant1 (SISO)_NTNV EMC-TRF-01 Rev 1.0 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Report No.: GZCR220600084702 Page: 90 of 116 2. Bandwidth 2.1 6dB BW 2.1.1 Test Result Mode TX Type Frequency (MHz) ANT 6dB Bandwidth (MHz) Verdict Result Limit 802.11b SISO 2412 1 9.091 >=0.5 Pass 2437 1 9.066 >=0.5 Pass 2462 1 9.112 >=0.5 Pass 802.11g SISO 2412 1 16.335 >=0.5 Pass 2437 1 16.346 >=0.5 Pass 2462 1 16.368 >=0.5 Pass 802.11n (HT20) SISO 2412 1 17.327 >=0.5 Pass 2437 1 17.545 >=0.5 Pass 2462 1 17.545 >=0.5 Pass EMC-TRF-01 Rev 1.0 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Report No.: GZCR220600084702 Page: 91 of 116 2.1.2 Test Graph 802.11b_LCH_2412MHz_Ant1 (SISO)_NTNV 802.11b_MCH_2437MHz_Ant1 (SISO)_NTNV EMC-TRF-01 Rev 1.0 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Report No.: GZCR220600084702 Page: 92 of 116 802.11b_HCH_2462MHz_Ant1 (SISO)_NTNV 802.11g_LCH_2412MHz_Ant1 (SISO)_NTNV EMC-TRF-01 Rev 1.0 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Report No.: GZCR220600084702 Page: 93 of 116 802.11g_MCH_2437MHz_Ant1 (SISO)_NTNV 802.11g_HCH_2462MHz_Ant1 (SISO)_NTNV EMC-TRF-01 Rev 1.0 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Report No.: GZCR220600084702 Page: 94 of 116 802.11n(HT20)_LCH_2412MHz_Ant1 (SISO)_NTNV 802.11n(HT20)_MCH_2437MHz_Ant1 (SISO)_NTNV EMC-TRF-01 Rev 1.0 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Report No.: GZCR220600084702 Page: 95 of 116 802.11n(HT20)_HCH_2462MHz_Ant1 (SISO)_NTNV EMC-TRF-01 Rev 1.0 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Report No.: GZCR220600084702 Page: 96 of 116 3. Maximum Conducted Output Power 3.1 Power 3.1.1 Test Result Mode TX Type Frequency (MHz) Maximum Peak Conducted Output Power (dBm) Verdict ANT1 Limit 802.11b SISO 2412 15.26 <=30 Pass 2437 15.59 <=30 Pass 2462 15.71 <=30 Pass 802.11g SISO 2412 17.09 <=30 Pass 2437 17.51 <=30 Pass 2462 17.62 <=30 Pass 802.11n (HT20) SISO 2412 17.05 <=30 Pass 2437 17.49 <=30 Pass 2462 17.60 <=30 Pass Note1: Antenna Gain: Ant1: 0.00dBi; 4. Maximum Power Spectral Density 4.1 PSD 4.1.1 Test Result Mode TX Type Frequency (MHz) Maximum PSD (dBm/3kHz) Verdict ANT1 Limit 802.11b SISO 2412 -9.09 <=8 Pass 2437 -10.25 <=8 Pass 2462 -9.17 <=8 Pass 802.11g SISO 2412 -16.25 <=8 Pass 2437 -15.21 <=8 Pass 2462 -16.40 <=8 Pass 802.11n (HT20) SISO 2412 -15.96 <=8 Pass 2437 -16.24 <=8 Pass 2462 -16.38 <=8 Pass Note1: Antenna Gain: Ant1: 0.00dBi; EMC-TRF-01 Rev 1.0 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Report No.: GZCR220600084702 Page: 97 of 116 4.1.2 Test Graph 802.11b_LCH_2412MHz_Ant1 (SISO)_NTNV 802.11b_MCH_2437MHz_Ant1 (SISO)_NTNV EMC-TRF-01 Rev 1.0 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Report No.: GZCR220600084702 Page: 98 of 116 802.11b_HCH_2462MHz_Ant1 (SISO)_NTNV 802.11g_LCH_2412MHz_Ant1 (SI…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Francois-Xavier C Rouxel(CEO)
[email protected]3013324462Fax: 2402197994

Technical Contact

SGS-CSTC Standards Technical Services Co., LtdKobe Jian
[email protected]+862082155314

No.198 Kezhu Road, Science City Economic& · Guangzhou, Guangdong · China

Non-Technical Contact

SGS-CSTC Standards Technical Services Co., LtdKobe Jian
[email protected]+862082155314

Test Firm

SGS-CSTC Standards Technical Services Co., Ltd.Bonnie Liao
[email protected]020-8215-5379

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.41 GHz - 2.46 GHz57.81 mW
Confidentiality
Long Term
Grant Notes
Power Output listed is conducted. Device is an 802.11b/g/n device and enabled for 2.4GHz band as described in this filing. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20 MHz bandwidth modes.