Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
FCCID:2AVEX-TH612 ExternalPhotosoftheEUT Fig.1 Fig.2 FCCID:2AVEX-TH612 Fig.3 Fig.4 FCCID:2AVEX-TH612 Fig.5 Fig.6
FCCID:2AVEX-TH612 labelandlocation Fig.1 FCCID:2AVEX-TH612 Eyemassager Mode:TH-612 Rating:DC5V1A ShenzhentianheertechnologyCo.,ltd Madeinchina
FCCID:2AVEX-TH612 InternalPhotosoftheEUT Fig.1 Fig.2 BT Antenna FCCID:2AVEX-TH612 Fig.3 Fig.4 FCCID:2AVEX-TH612 Fig.5 Fig.6
Page 1 of 2 RFExposureevaluation FCCID:2AVEX-TH612 1.1.ApplicableStandard Accordingto§1.1307(b)(1),systemsoperatingundertheprovisionsofthissectionshallbeoperatedina mannerthatensuresthatthepublicisnotexposedtoradiofrequencyenergylevelinexcessofthe Commission’sguidelines. Accordingto§1.1310and§2.1093RFexposurerequirement KDB447498v06:MobileandPortableDevicesRFExposureProceduresandEquipmentAuthorization Policies 1.2.Requirement AccordingtoKDB447498D01GeneralRFExposureGuidancev06Section4.3.1StandaloneSARtest exclusionconsiderations:“UnlessspecificallyrequiredbythepublishedRFexposureKDBprocedures, standalone1-gheadorbodyand10-gextremitySARevaluationforgeneralpopulationexposureconditions, bymeasurementornumericalsimulation,isnotrequiredwhenthecorrespondingSARTestExclusion Thresholdcondition,listedbelow,issatisfied.Thesetestexclusionconditionsarebasedonsource-based time-averagedmaximumconductedoutputpoweroftheRFchannelrequiringevaluation,adjustedfortune-up tolerance,andtheminimumtestseparationdistancerequiredfortheexposureconditions.22Theminimum testseparationdistanceisdeterminedbythesmallestdistancefromtheantennaandradiatingstructuresor outersurfaceofthedevice,accordingtothehostformfactor,exposureconditionsandplatformrequirements, toanypartofthebodyorextremityofauserorbystander(see5)ofsection4.1).ToqualifyforSARtest exclusion,thetestseparationdistancesappliedmustbefullyexplainedandjustifiedbytheoperating configurationsandexposureconditionsofthetransmitterandapplicablehostplatformrequirements,typically intheSARmeasurementorSARanalysisreport,accordingtotherequiredpublishedRFexposureKDB procedures.WhennootherRFexposuretestingorreportingisrequired,astatementofjustificationand compliancemustbeincludedintheequipmentapproval,inlieuoftheSARreport,toqualifyfortheSARtest exclusion.Whenrequired,thedevicespecificconditionsdescribedintheotherpublishedRFexposureKDB proceduresmustbesatisfiedbeforeapplyingtheseSARtestexclusionprovisions;forexample,handheldPTT two-wayradios,handsets,laptops&tabletsetc.23“ [(max.powerofchannel,includingtune-uptolerance,mW)/(min.testseparationdistance,mm)] · [√f(GHz)] ≤3.0for1-gSARand≤7.5for10-gextremitySAR,where: •f(GHz)istheRFchanneltransmitfrequencyinGHz •PoweranddistanceareroundedtothenearestmWandmmbeforecalculation •Theresultisroundedtoonedecimalplaceforcomparison • 3.0and7.5arereferredtoasthenumericthresholdsinthestep2below Thetestexclusionsareapplicableonlywhentheminimumtestseparationdistanceis ≤ 50mmandfor transmissionfrequenciesbetween100MHzand6GHz.Whentheminimumtestseparationdistanceis<5 mm,adistanceof5mmaccordingto5)insection4.1isappliedtodetermineSARtestexclusion. 1.3.Manufacturingtolerance BLE(Peak) GFSK ChannelChannel00Channel19Channel39 Target(dBm)0.00.00.0 Tolerance±(dB)1.01.01.0 BT(Peak) GFSK ChannelChannel00Channel39Channel78 Target(dBm)1.01.01.0 Tolerance±(dB)1.01.01.0 Π/4DQPSK ChannelChannel00Channel39Channel78 Target(dBm)1.01.01.0 Tolerance±(dB)1.01.01.0 8DPSK Page 2 of 2 ChannelChannel00Channel39Channel78 Target(dBm)1.01.01.0 Tolerance±(dB)1.01.01.0 2.EvaluationResult EvaluationResults Band/Modef(GHz) Antenna Distance (mm) RFoutputpower (includingtune-up tolerance) SARTest Exclusion Threshold SARTest Exclusion dBmmW BLE2.48051.0 1.2589 0.397<3.0Yes BT2.48052.0 1.5849 0.499<3.0Yes 3.Conclusion ThemeasurementresultscomplywiththeFCCLimitper47CFR2.1093fortheuncontrolledRFExposure andSARExclusionThresholdperKDB447498v06. .....................EndofReport.........................
Antennaspec 1.AntennaDescription: AntennatypePCBantenna Model2.4G-ANT Frequencyrange2400MHz~2500MHz ManufacturerZHUHAIJIELITECHNOLOGYCO.,LTD AddressRoom701-3,seventhfloor,ChengfengDaxia,833Renmin Road,XiangzhouDistrict,Zhuhai 2.AntennaPhoto(mm): 3.AntennaEfficiencyandGain: Frequency(MHz)240024402480 Efficiency(%)40.3543.1645.92 PEAKGain(dBi)-0.75-0.63-0.58 4.RadiationPattern:
ShenzhenGUORENCertificationTechnologyServiceCo.,Ltd. 101#,BuildingK&BuildingT,TheSecondIndustrialZone,JiazitangCommunity, FenghuangStreet,GuangmingDistrict,Shenzhen,China FCCPART15SUBPARTCTESTREPORT FCCPART15.247 ReportReferenceNo........................: FCCID.................................................: GRCTR241202042-01 2AVEX-TH612 Compiledby (position+printedname+signature) .. : TestingEngineerJimmyWang Supervisedby (position+printedname+signature)..: ProjectEngineerKelleyZhang Approvedby (position+printedname+signature)..: ManagerSamWang Dateofissue.........................................:Jan.06,2025 TestingLaboratoryName................: ShenzhenGUORENCertificationTechnologyServiceCo.,Ltd. Address ................................................. : 101#,BuildingK&BuildingT,TheSecondIndustrialZone,Jiazitang Community,FenghuangStreet,GuangmingDistrict,Shenzhen, China Applicant’sname...............................: ShenzhentianheertechnologyCo.,ltd Address ................................................. : ZhaoshanIndustrialZone,ChuangxinRd.,Tangxiayong,Songgang St.,BaoanDist.,shenzhen Testspecification..............................: Standard................................................:FCCPart15.247 ShenzhenGUORENCertificationTechnologyServiceCo.,Ltd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenGUORENCertificationTechnologyServiceCo.,Ltd.isacknowledgedascopyrightownerand sourceofthematerial.ShenzhenGUORENCertificationTechnologyServiceCo.,Ltd.takesno responsibilityforandwillnotassumeliabilityfordamagesresultingfromthereader'sinterpretationofthe reproducedmaterialduetoitsplacementandcontext. Testitemdescription ........................ : Eyemassager TradeMark ............................................ : / Manufacturer ......................................... : ShenzhentianheertechnologyCo.,ltd Model/Typereference.........................: TH-612 ListedModels......................................: TH-611,TH-301,TH-823,TH-811,TH-815,TH-816,TH-812,TH- 813,TH-203,JY-203,TH-205,TH-615,TH-616,JY-008 FirmwareVersion ................................. :V1.0 HardwareVersion................................:V1.0 Modulation...........................................: GFSK Frequency.............................................. From2402MHzto2480MHz Ratings ................................................... : 5.0V1.0A(chargedbyDC5VPowerAdapter)or 3.7V1200mAh(ByLi-ionrechargeablebattery) Result.....................................................: PASS ReportNo.:GRCTR241202042-01Page 2 of 33 TESTREPORT EquipmentunderTest:Eyemassager Model/Type:TH-612 ListedModels:TH-611,TH-301,TH-823,TH-811,TH-815,TH-816,TH-812,TH- 813,TH-203,JY-203,TH-205,TH-615,TH-616,JY-008 Applicant : ShenzhentianheertechnologyCo.,ltd Address: ZhaoshanIndustrialZone,ChuangxinRd.,Tangxiayong, SonggangSt.,BaoanDist.,shenzhen Manufacturer : ShenzhentianheertechnologyCo.,ltd Address: ZhaoshanIndustrialZone,ChuangxinRd.,Tangxiayong, SonggangSt.,BaoanDist.,shenzhen TestResult:PASS Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetest laboratory. ReportNo.:GRCTR241202042-01Page 3 of 33 Contents 1TESTSTANDARDS..............................................................................................................................4 2SUMMARY.................................................................................................................................................5 2.1GeneralRemarks..........................................................................................................................................5 2.2ProductDescription.....................................................................................................................................5 2.3EquipmentUnderTest.................................................................................................................................5 2.4ShortdescriptionoftheEquipmentunderTest(EUT).............................................................................5 2.5EUTconfiguration.........................................................................................................................................5 2.6EUToperationmode.....................................................................................................................................6 2.7BlockDiagramofTestSetup.......................................................................................................................6 2.8RelatedSubmittal(s)/Grant(s)...................................................................................................................6 2.9Modifications.................................................................................................................................................6 3TESTENVIRONMENT........................................................................................................................7 3.1Addressofthetestlaboratory....................................................................................................................7 3.2TestFacility...................................................................................................................................................7 3.3Environmentalconditions............................................................................................................................7 3.4Summaryofmeasurementresults..............................................................................................................8 3.5Statementofthemeasurementuncertainty..............................................................................................8 3.6EquipmentsUsedduringtheTest..............................................................................................................9 4TESTCONDITIONSANDRESULTS.........................................…
Text truncated - open the document above for the full version.
FCCID:2AVEX-TH612 TestSetupPhotosoftheEUT TestSetupPhoto(s)ofRadiatedEmissionsMeasurement Fig.1 Fig.2 FCCID:2AVEX-TH612 TestSetupPhoto(s)ofConductedEmissionsMeasurement Fig.3
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 900.00 µW |

Eye massager
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter